All PHASE ADDERS, PHASE SPLITTERS, and POWER INTERRUPTERS are
warranted to purchasers for resale or use in business for 1
year from the date of purchase from EYLANDER ELECTRIC. For users who
purchase equipment that takes a period of time for the installation,
a copy of the invoice, with date of purchase, together with the
returned warranty, dated and signed by the Electrical Inspector or a
representative of the serving utility as to their acceptance of the
installation, will be sufficient for an extension of warranty. The
maximum length of warranty shall be 18 months from date of
purchase.
LIMITATION OF WARRANTY
Any part that is determined by EYLANDER ELECTRIC to be defective in
material or workmanship and is returned to us, shipping costs
prepaid by the sender, will be repaired or replaced as the exclusive
remedy at our option. If the converter was purchased from an
electrical distributor or machinery dealer, then the end user must
apply for warranty at the source of purchase. The maximum amount of
the warranty is the amount paid for the converter.
Spikes are not uncommon when phase converters are used to
manufacture the 3rd leg for three phases; however, there are many
spikes coming from the utility power and no utility will claim to
have clean power.
Whenever electronic equipment, computers, process control equipment,
etc., are going to be used in the building, a power conditioner or
surge suppresser should be installed at the service, or else a
U.P.S. system should be ahead of any critical equipment.
ADDITIONAL PARTS WARRANTY
There is an additional 5-year warranty on all run capacitors and a
5-year warranty on the motors that we use for rotors. We use rotors
built by LINCOLN ELECTRIC because they provide the best phase
balance for our formula for building our PHASE ADDERS.
CONVERTERS MUST BE SIZED ACCORDING TO LOAD
The S and SB PHASE SPLITTER models are built for single-motor
operation only. They are not to be connected to a larger or smaller
motor than the nameplate rating. If they are hooked up to a smaller
motor, it will destroy the windings; if they are hooked up to a
larger motor, then the motor will lack power to start and pull the
load. No converter should have more than 20 starts per hour.
Eylander Electric disclaims any IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Also, the
PHASE ADDER rotary converters are to be sized according to load to
ensure proper performance of motors.
LIGHT START DUTY: Yields maximum 80% of HP load
REGULAR START DUTY: Yields maximum 90% of HP load
HEAVY START DUTY: Yields maximum 100% of HP load
MOTORS ABOVE CODE LETTER F: Use one size larger than heavy-duty
rating
CNC machines should have their own converters sized EXTRA HIGH
TORQUE.
Hydraulic presses, paper cutters, deep well pumps, heat pumps, or
any other load that may have a hard start on full load—in order to
get the service factor rating of the motor, you should use the heavy
start duty rating. For foreign-made equipment that uses DIRECT DRIVE
in the higher speed ranges, air compressors, or dead weight start
hoists, use the EXTRA HIGH TORQUE formula.
SPECIAL PARTS REPLACEMENT PROGRAM
All parts used in the Phase Converters should be available from a
local electrical supply company. We use all STANDARD NAME PARTS in
our converters. After the warranty period, if you are unable to
obtain the parts locally, then as a service we will ship the parts
UPS NEXT DAY AIR RED LABEL and you will have the parts within 24
hours.
|

|
|
|
News... |
|
Updated Web Site.
Catalogs are now available for download from our web
site. They are in a .pdf format.
|
 |
|