How much gas does it take to run a 50 MW Gas Fired Peaker?
50 MW
16 Peak Hours / Day
10,000 Btu / kWh (implied efficiency of 34%)
1,000 kWh / MWh
1,000 Btu/cf
8,000,000,000 Btu / Day
8,000 MMBtu / Day
8 MMcf / Day
250 Peak Days/Year (5 days, 50 weeks)
2,000,000,000,000 Btu / Year
2,000,000 MMBtu / Year
2,000 MMcf/year
[
Home ]
[
Links and News ]
[
Academic ]
[
Environmental ]
[
Reference ]
Btu = British Thermal Unit
1 Btu = energy required to raise 1 cubic foot of water (16 oz) 1 degree Fahrenheit
1 Btu = 1,055 joules
3412 Btu = 1 kWh
A wooden kitchen match produces approximately 1 Btu
1 MMBtu = 1 million Btu (a thousand, thousand Btu)
1 MMBtu = 1 decatherm
1 MMBtu = 1,000 cubic feet (cf)
1 MMcf = 1 million cf
Prices for gas are usually given in $/MMBtu