Hardware manuals can be found at:
POST ERROR CODES
Error Description Actions/Possible FRU's
-----------------------------------------------------------------------------
FIRMWARE ERROR CODES
00010000 CPU card test error CPU card
0001000A Machine Check Use minimum config MAP
0001500x Error while erasing system firmware CPU card
00016000 Use with Fxx Codes
00016010 System VPD access failure Sys. Bd., VPD module
00017001 CMOS error Battery
00017002 CMOS data gone/not initialized Battery
00017003 Power interruption during boot Update boot sequence
00017006 Tamper evident detected or battery
00017007 Maximum login tries Power on Reset
00017008 Maximum login tries Power on Reset
00017013 No power on password entered
00017015 Tamper evident is detected-security or Bad CMOS Battery
00018000 Bad flash image CPU card
00020000 Memory test error
000210y0 Bad memory in slot "y" (1-8) Bad/unsupported memory
00031100 Keyboard in the wrong port
00031300 Failed to register keyboard interrupt Keyboard, System Board
00070000 Service Processor POST failure Service Proc., Sys. Bd.
00070001 CPU card or power supply failure
00070006 Slow or stuck fan Fans, SP, System Board
00070007 System over temperature
00070008 Environmental condition Use with Fxx codes
00070009 Environmental condition Use with Fxx codes
00070010 Environmental condition Use with Fxx codes
00070011 Environmental condition Use with Fxx codes
00070012 Service processors fails self test Serv. Proc., Sys. Bd.
00070013 Bad NVRAM CRC error Battery, System Board
00070014 Bad service processor firmware Re-program firmware
00070015 Bad service processor VPD Serv. Proc., Sys. Bd.
00070016 Bad processor firmware failure Firmware update, Serv. Proc.
00070017 Bad or low battery Battery, SP, Sys. Bd.
00070018 EPOW test failure Serv. Proc., Sys. Bd.
00070019 Interrupt (IRQ13) test failure Sys. Bd., Serv. Proc
-----------------------------------------------------------------------------
0037cyyi SCSI controller interface error
0208cyyi SCSI device/adapter error
0210cyyi SCSI DASD error
0211cyyi SCSI tape error
0215cyyi SCSI CDDROM error
c=SCSI controller ID assigned in the following order:
1. PCI slot 1
2. PCI slot 2
3. Integrated controller
4. PCI slot 3
5. Continues until last slot...
Example: SCSI card slot 2 = ID 0
Integrated SCSI = ID 1
SCSI card slot 3 = ID 2
Example: Integrated SCSI = ID 0
SCSI card slot 3 = ID 1
yy=POST error status codes
08 Invalid device number
11 No SCSI card
13 Command failed
28 Reservation conflict
29 Device not available
43 Not enough memory
47 Waiting for completion
49 Sense needed
51 Reset needed
55 Not ready or no media
56 Invalid (unsupported) command
57 Write protected
59 Media error
60 Hardware error
61 Unit attention
62 Blank check
63 Command abort
64 Busy
65 Media
66 Script error
67 Invalid address
68 Media changed
69 Device reset
70 Format in progress
71 Format corrupted
72 Start required
73 Device ID conflict
74 Manual intervention
75 Media not found
76 In progress
77 Media eject failed
78 Write protect failed
80 SCSI controller interface error
81 SCSI controller interface error
82 SCSI bus access error
83 SCSI fuse bad or PTC tripped
84 SCSI device command failed
85 SCSI controller interface error
86 SCSI controller interface error
87 Short record length
88 SCSI bus parity error
89 SCSI device no reset
90 Time out error
99 SCSI controller interface error
i=SCSI ID (0-9 or A-F)
01291000 An error during L2 Cache test CPU card
0243025y Graphics controller, DAC failure Grpahics PCI card slot y
-----------------------------------------------------------------------------
20100xxx Power Supply
20A80xxx Remote IPL error
20A80000 Insufficient Information to boot Verify IP address
20A80001 Client IP address already used Change IP address
20A80002 Cannot get gateway IP address Refer to Fxx Boot Problems
20A80003 Cannot get server hardware address Refer to Fxx Boot Problems
20A80004 Bootp failed See Checkpoint F75
20A80005 File transmission (tftp) failed Check network connection
20D00xxx Unknown/Unrecognized device
20D0000F Device selftest failure, no SRN Locate device with SMS
20D00010 Device selftest failure
20E00000 Power on password entry error Wrong password entered
20E00001 Privileged-access password entry err. Wrong password entered
20E00002 Privileged-access password jumper is in wrong jumper position
20E00003 Power on password must be set for Unattended Mode
20E00004 Battery needs drained or replaced Battery, System Board
20E00005 EEPROM locked-Power on reset--or-> Bad System Board
20E00008 CMOS corrupted or tampering evident Battery, System Board
20E00009 Invalid password entered 3 times Power on reset, System Bd.
20E0000A EEPROM lock problem PAP jumper, System Board
20E0000B EEPROM write problem System Board
20E0000C EEPROM read problem System Board
20E00017 Cold boot needed for password entry Power on reset
20EE0xxx Informational
20EE0003 IP parameter requires 3 delimiters 000.000.000.000
20EE0004 Invalid IP parameter
20EE0005 Invalid IP parameter (>255) 255.000.000.000
20EE0006 No SCSI controllers Adapter, System Board
20EE0007 Keybaord not found Keyboard, System Board
20EE0008 No adapters found Adapter, Riser, System Bd.
21A00xxx SCSI disk drive Device, cable, controller
21A00001 Test Unit Ready Failed (hardware) Device, cable, controller
21A00002 Test Unit Ready Failed-sense data Media, device
21A00003 Send diagnostic failed Device
21A00004 Send diagnostic failed-DevOfl cmd Device
21E00xxx SCSI tape
21ED0xxx SCSI changer
21EE0xxx Other SCSI device
21F00xxx SCSI CDROM
21F20xxx SCSI Read/Write Optical
25010xxx Flash
25010000 No diskette in drive Looking for firmware image
25010001 Diskette seek error
25010002 Diskette doesn't contain *.IMG file Insert firmware update dskt
25010003 Can't open OPENPROM package System Board
25010004 Can't find OPENPROM node System Board
25010006 System id's don't match Use correct firmware dskt
25010007 Image has bad CRC Replace firmware dskt
25010008 Flash write protected-Power on reset System Board
25010009 Flash module not supported/recognized Use correct firmware dskt
2501000A Flash write protected-Power on reset System Board
25A0xxy0 L2 Cache - refer to 2B2xxyrr CPU, System Board
25A80xxx NVRAM Low Battery, Rebuild Config
25A80000 Initialization failed
25A80001 All NVRAM initialized
25A80002 GE area preserved
25A80011 Data corruption detected-NVRAM
25A80012 Data corruption detected
25A80100 NVRAM data validation check failed Power On Reset
25AA0xxx EEPROM Security jumper, System Bd.
25AA0000 Unable to unlock EEPROM
25AA0001 Read-Recv error
25AA0002 Read-Trans error
25AA0003 Write-enable error
25AA0004 Write-recv error
25AA0005 Write-disable error
25AA0006 Write-Trans error
25AA0007 Unable to lock EEPROM
-----------------------------------------------------------------------------
25Cyyxxx Memory Memory PD
25Cyy001 DIMMS fails memory test Memory DIMM
25Cyy002 DIMM not supported
yy=Memory DIMM PD bits
-----------------------------------------------------------------------------
PD Value Size Speed(nsecs) Parity/ECC Single/Dual
-----------------------------------------------------------------------------
64 8MB 60 ECC Single
69 16MB 60 ECC Single
6B 32MB 60 ECC Single
6D 64MB 60 ECC Single
6F 128MB 60 ECC Single
------------------------------------------------------------------------------
28030xxx RTC (Real Time Clock) Reset passwords/date/time
28030001 RTC not updating RTC needs initialized
28030002 Bad date/time Reset date/time
29000002 Keyboard/mouse controller failed System Board
29A00003 Keyboard missing Keyboard, System Board
29B00004 Mouse missing Mouse, System Board
-----------------------------------------------------------------------------
2B200042 Unknown processor type
2B2xxyrr xx=processor type/speed 21 166Mhz 604+
22 200Mhz 604+
y=Cache information 0 Integrated cache or N/A
5 512KB
6 1MB
7 256KB
D ICBM 1MB
2B2xxy22 Bad processor/CPU
2B2xxy31 Disabled due to Asymetrical MP
-----------------------------------------------------------------------------
2BA00xxx Service Processor (SP)
2BA00000 Service Processor POST failure
2BA00001 CPU Card or power supply failure
2BA00006 FAN error incorrectly reported Fans, Service Proc., Sys Bd.
2BA00007 SP reports over temperature Fans, System Board
2BA00008 SP reports over temperature Fans, System Board
2BA00009 CPU over temperature Fans, CPU, System Board
2BA00010 Fast shutdown pending Power supply, System Board
2BA00011 SP reports CPU failure Power supply, System Board
2BA00012 SP reports self-test failure Service Proc., System Board
2BA00013 SP reports bad NVRAM CRC Battery, System Board
2BA00014 SP reports bad processor firmware Rebuild firmware
2BA00015 SP reports bad SP VPD Service Proc., System Board
2BA00016 SP reports firmware failure Update firmware, Serv. Proc.
2BA00017 SP reports bad/low battery Battery, SP, System Board
2BA00018 EPOW test failure Serv. Proc., System Board
2BA00019 IRQ13 test failure System Board, Serv. Proc.
2BA00020 SP reports VPD access failure System Board, VPD module
2BA00022 SP reports bad CRC - CMOS/NVRAM System Board
2BA00023 CPU card test error CPU card
2BA00100 SP firmware recovery info can't be written to diskette
2BA00101 Service Processor not installed
2BA00102 No SP diskette in drive
2BA00103 SP firmware diskette corrupted
2BA00104 SP firmware diskette same level
2BA00200 SP firmware update error Unplug/Replug-try again
2BA00201 SP firmware update error
2BA00202 SP firmware update error
2BA00203 SP firmware update error
2BA00204 SP firmware update error
-----------------------------------------------------------------------------
40100005 Loss of system power detected Power Supply
40111002 Unknown power problem Power Supply, Sys Bd, SP
40111022 High 5.0 voltage Power Supply, CPU card
40111032 High 3.3 voltage CPU card, Power Supply
40111042 High 2.5 voltage CPU card, Power Supply
40111052 High +12 voltage Power Supply, Sys. Bd.
40111062 High -12 voltage Power Supply, Sys. Bd.
40111082 Low 5.0 voltage Power Supply, CPU card
40111092 Low 3.3 voltage CPU card, Power Supply
401110A2 Low 2.5 voltage CPU card, Power Supply
401110B2 Low +12 voltage Power Supply, Sys. Bd.
401110C2 Low -12 voltage Power Supply, Sys. Bd.
40200001 Unknown cooling problem Fans
40200021 CPU temperature warning
40200023 Critical CPU temperature warning
40200031 I/O planar temperature warning
40200033 Critical I/O planar temperature
40200041 Memory temperature warning
40200043 Critical memory temperature
40210011 Slow fan
40210014 Stopped fan
40A00000 IPL ROS surveillance interval exceeded-Firmware IPL failure
40B00000 Operating system surveillance interval exceeded
40D00003 Unknown slow shutdown commanded Critical cooling problem
40D00004 Unknown fast shutdown commanded Locked fan failure
-----------------------------------------------------------------------------
80001200 Bad firmware recovery diskette Diskette
80001300 Same firmware level already loaded
80001400 Firmware doesn't support system
80001500 Firmware update file corrupted
80001600 Firmware update file not on drive Verify drive/path/filename
80001700 Firmware file on disk corrupted Obtain a new file
80001800 Valid firmware file not located Verify drive/path/filename
80001900 Firmware doesn't support system
80002000 2 Flash images found
80002100 Firmware update couldn't be loaded Verify drive/path/filename
80002200 Firmware update module write-protect POR, Retry, CPU card
80002300 Utility version not supported POR, Retry, CPU card
80002400 Firmware module not supported Flash on CPU card bad
80002500 Firmware module not supported Flash on CPU card bad
80002600 Firmware module write-protected POR, Retry, CPU card
80002700 Backup recover diskette needed Insert diskette
80002800 Update firmware diskette not in drive Insert diskette
80072000 Service Processor not installed Install Serv. Processor
-----------------------------------------------------------------------------
91001100 Remote IPL error, insufficient memory Defective/insufficient mem.
91001200 Remote IPL error - incorrect IP format for client IP address
91001300 Remote IPL error - incorrect IP format for server IP address
91001400 Remote IPL error - incorrect IP format for gateway IP address
91001500 Remote IPL error - incorrect IP format for netmask
91001600 Remote IPL error - error writing to NVRAM
91001700 Remote IPL error - ethernet adapter not found
91001900 Remote IPL error - token-ring adapter not found
91002000 Remote IPL error - no network adapters recognized
91002200 Remote IPL error - ping failed
M0CON000 System hung during POST Go to minimum config
M0CPU000 CPU POST failed CPU Card, System Board
M0CPU001 Checkstop occurred CPU Card, System Board
M0FD0000 System hung during diskette POST System Board, Diskette Drv.
M0GA0000 Graphics Adapter POST failed Graphics Adapter
M0HD0000 System hung during POST Go to minimum config
M0KBD000 System hung during keyboard POST System board, Keyboard
M0KBD001 System didn't respond to key entry Type 101 Keyboard
M0KBD002 System didn't respond to key entry Type 102 Keyboard
M0KBD003 System didn't respond to key entry Type 106 Keyboard
M0MC0001 Machine Check Go to minimum config
M0MEM000 No good memory found Memory, System Board
M0MEM001 No good memory found Memory, System Board
M0MEM002 System hung during memory POST Go to minimum config
M0PS0000 Power failure Go to Power MAP
M0SCSI00 Unable to load diagnostics Go to minimum config
M0SCSI01 Unable to load diagnostics Go to minimum config
M0SPK000 Continuous beep is heard System Board
M0SPK001 The system doesn't beep Speaker, System Board
M0BT0000 Audio error--Use Fxx Code, if none-- Go to minimum config
M0NET000 Network error--Use Fxx Code, if none--Go to minimum config
Firmware Checkpoint Codes
F00 Manufacturing - Reserved for Parallel port download protocol
F01 Clear the EPOW register 1. Memory modules 2. system board
F02 Determine system bus speed, set ISA advisor
F04 Set memory refresh
F05 Transfer control to Operating System ( nornmal boot )
Action: Try to boot and run standalone diagnostics against the system.
particularly
against the intended boot device. If the diagnostics
are successful, it may
be necessary to perform an operating system
specific recovery process,
or reinstall the operating system.
F06 Jump to set environment or check flash
F08 Run recovery block base memory, test 2k, then set stack
F09 Copy CRC verification code to RAM
F0A Turn on cache
F0B Flush cache
F0C Jump to CRC verification code in RAM
F0D Compute composite image CRc
F0E Jump back to ROM
F0F Turn off cache
F10 Check if composite image CRC is valid
F11 Good CRC - jump to composite image
F12 Bad CRC - initialize base memory, stack
F13 Bad CRC - copy uncompressed recovery block code to RAM
F14 Bad CRC - jump to code in RAM
F15 Bad CRC - turn on cache
F16 Bad CRC - copy recovery block data section to RAM
F17 Bad CRC - invalidate and flush cache, set TOC
F18 Bad CRC - branch to high level recovery control routine
F19 Initialize base memory, stack
F1A Copy uncompressed recovery block code to RAM
F1B Jump to code in RAM
F1C Turn on cache
F1D Copy recovery block data section to RAM
F1E Invalidate and flush cache, set TOC
F1F Branch to high level control routine
F20 Initialize system I/O
F21 Run a console diagnostic routine
F22 No memory found
F23 No DIMM found in socket
F24 Remove bad DIMM found from DIMM information
F25 Unsupported DIMM detected
F26 Check valid image - start
F27 Check valid image - successful
F28 Wait for interrupt
F29 Transfers information to the business audio chip
F2B Wait until sound chip has been initialized
F2C Initialize the current input/pointer device
F2D Initialize the current output
F2E Register a console driver
F30 Set up early memory allocation heap, intialize Super I/O
F31 Determine system bus speed, set ISA driver
F32 Resync to SP (Console image)
F33 Set memory refresh
F35 Jump to set environment
F40 Initialize interrupt subsystem and 8259s
F41 SP command setup
F42 SP mailbox interface
F43 get_vpd entry
F44 init_sp entry
F45 sp_recovery -> resync SP & CPU
-----------------------------------------------------------------------------
00016000 Error and the following Checkpoint Code
F46 IRQ13 stuck high Bad System Board or Service Processor
F47 Entry to error checking routine-No system board VPD, bad CRC Bad System Board
F48 Power supply or system board problem Other 8-digit Codes possible: 00070010, 40100005
F49 Voltage problem, system board, power supply or CPU 5V high/low-bad power supply,
CPU card,
Other 8-digit Codes possible: 40111022, 40111082
F4A Voltage problem, system board or power supply 12V high/low - bad power supply,
CPU card,
System Board Other 8-digit Codes possible: 40111052, 401110B2,
401110C2, 40111062, 00070010
F4B CPU over temperature or bad system board Other 8-digit
Codes possible: 40200021, 00070009
F4C start bit-map display function
F4D Bit-map file read into memory, start processing
F4E End bit-map display function
F4F IO/MEM over termperature or bad system board 8-digit Codes
possible:
40200031, 40200041,00070008
F50 Initialize CMOS RTC periodic interrupt
F51 System board or system over temperature, CPU card Critical
Temp Other 8-digit Codes possible: 40200023, 40200033, 40200043, 00070008, 00070009
F52 Bad system board (fan fail reported) Other 8-digit Codes possible: 40210011, 40210014
F53 Bad system board or Fans Other 8-digit Codes possible: 40210011, 40210014
F54 Fan fail warning
F55 Bad system board (unsupported EPOW)
F56 Voltage problem, system board, power supply or CPU 3.3V/2.5V high/low
Other 8-digit Codes possible:
40111032, 40111092, 40111042, 401110A2
-----------------------------------------------------------------------------
F57 Bad or low battery
F58 IRQ13 test failure
F59 EPOW test failure
F5A Spurious IRQ6 interrupt (i.e. interrupt glitch)
F5B Fan failure warning
F5B Transfer control to Operating System ( service mode bootlist )
F5C Clear EPOW register failure
F5D Clear EPOW register failure
F60 Initialize keyboard/mouse controller, and password
F61 Extended memory initialization command
F62 Diskette initialization command
F64 Test of day routine
F6A SCSI initialization command
F70 Initialize debugger
F71 Start checking whether CMOS contents are valid
F72 End checking whether CMOS contents are valid
F73 Dumps contents of CMOS data area to a file
F74 Establishing Host conmnection
F75 BootP request
F77 Resync to SP (Recvoery image)
F79 Dupms contents of NVRAM data area to a file
F7A NVRAM initialization
F7B Check NVRAM validity CRC
F7C Loads contents of CMOS from file
F80 Initialize system call table
F82 Register a manager for use by the system
F88 Halt. System locked by error condition - power off
F90 Initialize VDISK file system
F91 Low-level initialize VDISK file systems
F94 Start SCSI initialization
F96 SCSI bus scan start
F97 SCSI polling interrupt
F98 SCSI device detected
F9E Real Time clock RTC initialization
F9F Exit SCSI initialization
FA0 Start resident monitor, run V:autoexec.6md-initializes various sub- systems-video,
keyboard/mouse, extended memory, diskette, SCSI, etc.
FA1 Enter resident monitor
FA2 Resident monitor process
FA3 Resident monitor process
FA4 Exit resident monitor
FA5 ASCII terminal initialization
FA6 ASCII terminal initialization exit
FA9 p9 driver initialization
FAA p9 driver exit
FAB Keyboard driver initialization
FAC Keyboard driver exit
FAD Mouse driver initialization
FAE Mouse driver exit
FB0 Initialize rest of file system
FB1 Diskette initialization
FB2 Diskette drive type determination
FB3 Diskette initialization complete
FC0 Check if flash ROM OK
FCA Build boot table - Networks
FCB Build boot table - DASD
FCC Build boot table - CDROM
FCD Build boot table - diskettes
FCE No operating system boot, exit normal boot sequence
FD0 Start of boot sequence
FD2 No operating system boot - ensure CMOS RTC periodic clock updates displayed
FD4 Initialize console for loading diagnostics
FD8 Exit from diagnostic - run resident monitor
FDA IRQ15
FDB Unexpected processor exception
FDC Dynamic console selection
FDD Early processor exception
FDE Alternating pattern of FDE and FDA indicates a processor exception has been detected.
FE1 Test timeout
FE2 Initialize system I/O
FE4 Initialize super I/O with default values
FE6 Set up early memory allocation heap
FE8 Initialize primary diskette drive in polled mode
FEA Try to load in recovery image from diskette
FEB F30 Verify recovery image is
The F40 action plan should also work
valid | on the F30 Use the F30 firmware.
F40 Firmware flash corrupted, | A C T I O N
load from diskette |
If the system will not boot up fully|and the checkpoint display reads "FEB",
|the firmware is partially corrupted, but
|should be recoverable.
Make a copy of |the firmware update diskette, rename the
|.img file to
PRECOVER.IMG and insert|this "recovery" diskette in the drive
|
when the FEB appears on the checkpoint
display.
FEC Get recovery image entry point
FED Invalidate instruction cache
FEE Jump to composite image
FF0 Manufacturing - Check fo parallel port hook
FF4 Manufacturing - Start flag not received
FF5 Manufacturing - Invalid start flag received
FF6 Manufacturing - Receive character timeout
FF7 Manufacturing - CRC value mismatch
FFA Error during flash update
FFC Operating system boot - no errors reported by IPL ROS
FFD Operating system boot - non-critical errors reported by IPL ROS
FFE No boot - critical error(s) reported by IPL ROS -or- F1 key pressed
Diagnostic Information for Multiple Bus Systems
Configuration Program Indicators
500 Querying Standard I/O slot.
501 Querying card in Slot 1.
502 Querying card in Slot 2.
503 Querying card in Slot 3.
504 Querying card in Slot 4.
505 Querying card in Slot 5.
506 Querying card in Slot 6.
507 Querying card in Slot 7.
508 Querying card in Slot 8.
510 Starting device configuration.
511 Device configuration completed.
512 Restoring device configuration files from media.
513 Restoring basic operating system installation files from media.
516 Contacting server during network boot.
517 Mounting client remote file system during network IPL.
518 Remote mount of the root and /usr file systems failed during network boot.
520 Bus configuration running.
521 /etc/init invoked cfgmgr with invalid options; /etc/init has been
corrupted or incorrectly modified(irrecoverable error).
522 The configuration manager has been invoked with conflicting options
(irrecoverable error).
523 The configuration manager unable to access the ODM database (irrecoverable error).
524 The configuration managers unable to access the config.rules in the
ODM database (irrecoverable
error).
525 The configuration manager unable to get data from customized device
in the ODM database (irrecoverable)
526 The configuration manager unable to get data from customized device
driver
in the ODM( irrecoverable error).
527 The configuration manager was invoked with phase 1 flag (irrecoverable error).
528 The configuration manager cannot find sequence rule, or no program name
specified in ODM(irrecoverable)
529 The configuration manager is unable to update ODM data (irrecoverable error).
530 The program savebase returned an error.
531 The configuration manager is unable to access the PdAt object class (irrecoverable error).
532 There is not enough memory to continue (malloc failure); irrecoverable error.
533 The configuration manager could not find a configure method for a device.
534 The configuration manager is unable to acquire database lock (irrecoverable error).
535 HIPPI diagnostics interface driver being configured.
536 The configuration manager encountered more than one sequence rule (irrecoverable error).
537 The configuration manager encountered an error when invoking
the program in the sequence rule.
538 The configuration manager is going to invoke a configuration method.
539 The configuration method has terminated, and control has returned
to the configuration manager.
551 IPL vary-on is running.
552 IPL vary-on failed.
553 IPL phase 1 is complete.
554 The boot device could not be opened or read, or unable to define NFS swap
device during network boot.
555 An ODM error when trying to vary-on rootvg, or unable to create an NFS swap device
556 Logical Volume Manager encountered error during IPL vary-on.
557 The root filesystem does not mount.
558 There is not enough memory to continue the system IPL.
559 Less than 2 M bytes of good memory are available to load the AIX kernel.
570 Virtual SCSI devices being configured.
571 HIPPI common function device driver being configured.
572 HIPPI IPI-3 master transport driver being configured.
573 HIPPI IPI-3 slave transport driver being configured.
574 HIPPI IPI-3 transport services user interface device driver being configured.
575 A 9570 disk-array driver is being configured.
576 Generic async device driver being configured.
577 Generic SCSI device driver being configured.
578 Generic commo device driver being configured.
579 Device driver being configured for a generic device.
580 HIPPI TCPIP network interface driver being configured.
581 Configuring TCP/IP.
582 Configuring Token-Ring data link control.
583 Configuring an Ethernet data link control.
584 Configuring an IEEE Ethernet data link control.
585 Configuring an SDLC MPQP data link control.
586 Configuring a QLLC X.25 data link control.
587 Configuring a NETBIOS.
588 Configuring a Bisync Read-Write (BSCRW).
589 SCSI target mode device being configured.
590 Diskless remote paging device being configured.
591 Configuring an LVM device driver.
592 Configuring an HFT device driver.
593 Configuring SNA device drivers.
594 Asynchronous I/O being defined or configured.
595 X.31 pseudo-device being configured.
596 SNA DLC/LAPE pseudo-device being configured.
597 OCS software being configured.
598 OCS hosts being configured during system reboot.
599 Configuring FDDI data link control.
5c0 Streams-based hardware drive being configured.
5c1 Streams-based X.25 protocol being configured.
5c2 Streams-based X.25 COMIO emulator driver being configured.
5c3 Streams-based X.25 TCP/IP interface driver being configured.
5c4 FCS adapter device driver being configured.
5c5 SCB network device driver for FCS is being configured.
5c6 AIX SNA channel being configured.
600 Starting network boot portion of /sbin/rc.boot
602 Configuring network parent devices.
603 /usr/lib/methods/defsys, /usr/lib/methods/cfgsys, or /usr/lib/methods/cfgbus failed.
604 Configuring physical network boot device.
605 Configuration of physical network boot device failed.
606 Running /usr/sbin/ifconfig on logical network boot device.
607 /usr/sbin/ifconfig failed.
608 Attempting retrieve client.info file with tftp. Note that a
flashing 608 indicates multiple attempt(s)
609 The client.info file does not exist or it is zero length.
610 Attempting remote mount of NFS file system.
611 Remote mount of the NFS file system failed.
612 Accessing remote files; unconfiguring network boot device.
614 Configuring local paging devices.
615 Configuration of a local paging device failed.
616 Converting from diskless to dataless configuration.
617 Diskless to dataless configuration failed.
618 Configuring remote (NFS) paging devices.
619 Configuration of a remote (NFS) paging device failed.
620 Updating special device files and ODM in permanent
filesystem with data from boot RAM filesystem.
622 Boot process configuring for operating system installation.
650 IBM SCSD disk drive being configured
658 PCI Fibre Channel Disk Subsystem Controller being identified or configured.
659 2102 Fibre Channel Disk Subsystem Controller Drawer being identified or configured.
660 2102 Fibre Channel Disk Array being identified or configured.
662 Ultra2 Intergrated SCSI controller.
663 IBM ARTIC960 RxD PCI Adapter is being configured
664 32x (MAX) SCSI-2 CD-ROM drive being configured
669 PCI Gigabit Ethernet Adapter
674 ESCON® Channel PCI Adapter
677 PCI Fiber Channel Arbitrated Loop Adapter
682 20x (MAX) SCSI-2 CD-ROM Drive being configured
638 4.5GB Ultra SCSI Single Ended Disk Drive being configured
689 4.5GB Ultra SCSI Single Ended Disk Drive being configured
690 9.1GB Ultra SCSI Single Ended Disk Drive being configured
700A 1.1 GB 8-bit SCSI disk drive being identified or configured.
701A 1.1 GB 16-bit SCSI disk drive is being identified or configured.
702A 1.1 GB 16-bit differential SCSI disk drive is being identified or configured.
703A 2.2 GB 8-bit SCSI disk drive is being identified or configured.
704A 2.2 GB 16-bit SCSI disk drive is being identified or configured.
705 Configuration method for the 2.2 GB 16-bit differential SCSI
disk drive
being run. If irrecoverable, halt.
706A 4.5 GB 16-bit SCSI disk drive is being identified or configured.
707A 4.5 GB 16-bit differential SCSI disk drive is being identified or configured.
708A L2 cache is being identified or configured.
710 POWER GXT150M graphics adapter being identified or configured.
711 Unknown adapter being identified or configured.
712 Graphics slot bus configuration is executing.
713 The IBM ARTIC960 device is being configured.
714 A video capture adapter is being configured.
715 The Ultramedia Services audio adapter is being configured.
This LED displays briefly on the panel.
717 TP Ethernet Adapter being configured.
718 GXT500 Graphics Adapter being configured.
720 Unknown read/write optical drive type being configured.
721 Unknown disk or SCSI device being identified or configured.
722 Unknown disk being identified or configured.
723 Unknown CD-ROM being identified or configured.
724 Unknown tape drive being identified or configured.
725 Unknown display adapter being identified or configured.
726 Unknown input device being identified or configured.
727 Unknown async device being identified or configured.
728 Parallel printer being identified or configured.
729 Unknown parallel device being identified or configured.
730 Unknown diskette drive being identified or configured.
731 PTY being identified or configured.
732 Unknown SCSI initiator type being configured.
733 7GB 8mm tape drive being configured.
734 4x SCSI-2 640MB CD-ROM Drive
736 Quiet Touch keyboard and speaker cable being configured.
741 1080MB SCSI Disk Drive
745 16GB 4mm Tape Auto Loader
746 SCSI-2 Fast/Wide PCI Adapter
747 SCSI-2 Differential Fast/Wide PCI Adapter
749 7331 Model 205 Tape Library
751 SCSI 32-bit SE F/W RAID Adapter
754 1.1GB 16-bit SCSI disk drive being configured.
755 2.2GB 16-bit SCSI disk drive being configured.
756 4.5GB 16-bit SCSI disk drive being configured.
757 External 13GB 1.5M/s 1/4 inch tape being configured.
763 SP Switch MX Adapter
764 SP System Attachment Adapter
772 4.5GB SCSI F/W Disk Drive
773 9.1GB SCSI F/W Disk Drive
774 9.1GB External SCSI Disk Drive
777 10/100Mbps PCI Ethernet Adapter being identified or configured.
778 POWER GXT3000P 3D PCI Graphics adapter being configured
77c A 1.0 GB 16-bit SCSI disk drive being identified or configured.
783 4mm DDS-2 Tape Autoloader
789 2.6GB External Optical Drive
78c PCI bus configuration executing
790 Multi-bus Integrated Ethernet Adapter being identified or configured.
797 TURBOWAYS® 155 UTP/STP ATM Adapter being identified or configured.
798 Video streamer adapter being identified or configured.
79c ISA bus configuration executing
7cc PCMCIA bus configuration executing
800 TURBOWAYS 155 MMF ATM Adapter being identified or configured.
803 7336 Tape Library robotics being configured
804 8x Speed SCSI-2 CD-ROM Drive being configured
806 POWER GXT800 PCI Graphics adapter being configured
807 SCSI Device Enclosure being configured
80c SSA 4-Port Adapter being identified or configured.
811 Processor complex being identified or configured.
812 Memory being identified or configured.
813 Battery for time-of-day, NVRAM, system I/O control logic being identified or configured.
814 NVRAM being identified or configured.
815 Floating-point processor test
816 Operator panel logic being identified or configured.
817 Time-of-day logic being identified or configured.
819 Graphics input device adapter being identified or configured.
821 Standard keyboard adapter being identified or configured.
823 Standard mouse adapter being identified or configured.
824 Standard tablet adapter being identified or configured.
825 Standard speaker adapter being identified or configured.
826 Serial Port 1 adapter being identified or configured.
827 Parallel port adapter being identified or configured.
828 Standard diskette adapter being identified or configured.
831 3151 adapter being identified or configured, or Serial Port 2 being identified or configured.
834 64-port async controller being identified or configured.
835 16-port async concentrator being identified or configured.
836 128-port async controller being identified or configured.
837 16-port remote async node being identified or configured.
838 Network Terminal Accelerator Adapter being identified or configured.
839 7318 Serial Communications Server being configured.
841 8-port async adapter (EIA-232) being identified or configured.
842 8-port async adapter (EIA-422A) being identified or configured.
843 8-port async adapter (MIL-STD 188) being identified or configured.
844 7135 RAIDiant Array disk drive subsystem controller being identified or configured.
845 7135 RAIDiant Array disk drive subsystem drawer being identified or configured.
846 RAIDiant Array SCSI 1.3GB Disk Drive
847 16-port serial adapter (EIA-232) being identified or configured.
848 16-port serial adapter (EIA-422) being identified or configured.
849 X.25 Interface Co-Processor/2 adapter being identified or configured.
850 Token-Ring network adapter being identified or configured.
851 T1/J1 Portmaster® adapter being identified or configured.
852 Ethernet adapter being identified or configured.
854 3270 Host Connection Program/6000 connection being identified or configured.
855 Portmaster Adapter/A being identified or configured.
857 FSLA adapter being identified or configured.
858 5085/5086/5088 adapter being identified or configured.
859 FDDI adapter being identified or configured.
85c Token-Ring High-Performance LAN adapter is being identified or configured.
861 Optical adapter being identified or configured.
862 Block Multiplexer Channel Adapter being identified or configured.
865 ESCON Channel Adapter or emulator being identified or configured.
866 SCSI adapter being identified or configured.
867 Async expansion adapter being identified or configured.
868 SCSI adapter being identified or configured.
869 SCSI adapter being identified or configured.
870 Serial disk drive adapter being identified or configured.
871 Graphics subsystem adapter being identified or configured.
872 Grayscale graphics adapter being identified or configured.
874 Color graphics adapter being identified or configured.
875 Vendor generic communication adapter being configured.
876 8-bit color graphics processor being identified or configured.
877 POWER Gt3(TM)/POWER Gt4(TM) being identified or configured.
878 POWER Gt4 graphics processor card being configured.
879 24-bit color graphics card, MEV2
880 POWER Gt1(TM) adapter being identified or configured.
887 Integrated Ethernet adapter being identified or configured.
889 SCSI adapter being identified or configured.
890 SCSI-2 Differential Fast/Wide and Single-Ended Fast/Wide Adapter/A.
891 Vendor SCSI adapter being identified or configured.
892 Vendor display adapter being identified or configured.
893 Vendor LAN adapter being identified or configured.
894 Vendor async/communications adapter being identified or configured.
895 Vendor IEEE 488 adapter being identified or configured.
896 Vendor VME bus adapter being identified or configured.
897 S /370(TM) Channel Emulator adapter being identified or configured.
898 POWER Gt1x(TM) graphics adapter being identified or configured.
899 3490 attached tape drive being identified or configured.
89c A multimedia SCSI CD-ROM is being identified or configured.
900 GXT110P Graphics Adapter being identified or configured.
901 Vendor SCSI device being identified or configured.
902 Vendor display device being identified or configured.
903 Vendor async device being identified or configured.
904 Vendor parallel device being identified or configured.
905 Vendor other device being identified or configured.
908 POWER GXT1000 Graphics subsystem being identified or configured.
910 1/4GB Fiber Channel/266 Standard Adapter being identified or configured.
911 Fiber Channel/1063 Adapter Short Wave
912 2.0GB SCSI-2 differential disk drive being identified or configured.
913 1.0GB differential disk drive being identified or configured.
914 5GB 8mm differential tape drive being identified or configured.
915 4GB 4mm tape drive being identified or configured.
916 Non-SCSI vendor tape adapter being identified or configured.
917 A 2.0GB 16-bit differential SCSI disk drive is being identified or configured.
918 A 2GB 16-bit single-ended SCSI disk drive is being identified or configured.
920 Bridge Box being identified or configured.
921 101 keyboard being identified or configured.
922 102 keyboard being identified or configured.
923 Kanji keyboard being identified or configured.
924 Two-button mouse being identified or configured.
925 Three-button mouse being identified or configured.
926 5083 tablet being identified or configured.
927 5083 tablet being identified or configured.
928 Standard speaker being identified or configured.
929 Dials being identified or configured.
930 Lighted program function keys (LPFK) being identified or configured.
931 IP router being identified or configured.
933 Async planar being identified or configured.
934 Async expansion drawer being identified or configured.
935 3.5-inch diskette drive being identified or configured.
936 5.25-inch diskette drive being identified or configured.
937 An HIPPI adapter is being configured.
942 POWER GXT 100 graphics adapter being identified or configured.
943 A 3480 or 3490 control unit attached to a System/370 Channel
Emulator/A adapter configured.
944 100MB ATM adapter being identified or configured
945 1.0GB SCSI differential disk drive being identified or configured.
946 Serial port 3 adapter is being identified or configured.
947 A 730MB SCSI disk drive is being configured.
948 Portable disk drive being identified or configured.
949 Unknown direct bus-attach device being identified or configured.
950 Missing SCSI device being identified or configured.
951 670MB SCSI disk drive being identified or configured.
952 355MB SCSI disk drive being identified or configured.
953 320MB SCSI disk drive being identified or configured.
954 400MB SCSI disk drive being identified or configured.
955 857MB SCSI disk drive being identified or configured.
956 670MB SCSI disk drive electronics card being identified or configured.
957 120MB DBA disk drive being identified or configured.
958 160MB DBA disk drive being identified or configured.
959 160MB SCSI disk drive being identified or configured.
960 1.37GB SCSI disk drive being identified or configured.
964 Internal 20GB 8mm tape drive identified or configured.
968 1.0GB SCSI disk drive being identified or configured.
970 Half-inch, 9-track tape drive being identified or configured.
971 150MB 1/4-inch tape drive being identified or configured.
972 2.3GB 8mm SCSI tape drive being identified or configured.
973 Other SCSI tape drive being identified or configured.
974 CD-ROM drive being identified or configured.
975 An optical disk drive is being identified or configured.
977 M-Audio Capture and Playback Adapter being identified or configured.
981 540MB SCSI-2 single-ended disk drive being identified or configured.
984 1GB 8-bit disk drive being identified or configured.
985 M-Video Capture Adapter being identified or configured.
986 2.4GB SCSI disk drive being identified or configured.
987 An Enhanced SCSI CD-ROM drive is being identified or configured.
989 200MB SCSI disk drive being identified or configured.
990 2.0GB SCSI-2 single-ended disk drive being identified or configured.
991 525MB 1/4-inch cartridge tape drive being identified or configured.
994 5GB 8mm tape drive being identified or configured.
995 1.2GB 1/4 inch cartridge tape drive being identified or configured.
996 A single-port, multi-protocol communications adapter is being identified or configured.
997 FDDI adapter being identified or configured.
998 2.0GB 4mm tape drive being identified or configured.
999 7137 or 3514 Disk Array Subsystem being configured.
D81 T2 Ethernet Adapter being configured.
Table 5-1. Service Processor Checkpoints.
E010 Starting Service Processor self-tests
E012 Begin to set up Service Processor heaps
E020 Configuring CMOS
E021 Configuring NVRAM
E040 Configuring Service Processor I/O
E042 Configuring modem on serial port 1
E043 Configuring modem on serial port 2
E04F Modem configuration successful Re-IPL.
E070 Service Processor is calling the Service Center
E071 Service Processor is calling System Administration
E072 Service Processor is calling the pager
E075 Entering Service Processor menus
Before replacing any parts, ensure the S1 and S2 ports either have no cables attached or the
cables are only attached to TTY or Modem devices.
E07A Waiting for keystroke from local console
E07B Waiting for keystroke from remote console
E07F Service Processor exiting from session with local or remote terminal.
E080 Service Processor flash update in progress
E081 Service Processor flash update completed
E082 Service Processor promoting flash from side B to side A.
E090 Changing the system processor configuration.
E0EF End of Service Processor reporting
Firmware Checkpoints
E100 Reserved
E101 Video enabled, extended memory test
E102 Firmware restart
E103 Set memory refresh (composite img)
E104 Set memory refresh (recovery block)
E105 Transfer control to Operating System (normal boot).
E108 Run recovery block base memory (test 2K),
E109 Copy CRC verification code to RAM
E10A Turn on cache
E10B Flush cache
E10C Jump to CRC verification code in RAM
E10D Compute composite image CRC
E10E Jump back to ROM
E10F Transfer control to Open Firmware
E110 Turn off cache, Check if composite image CRC is valid
E111 GOOD CRC - jump to composite image
E112 BAD CRC - initialize base memory, stack
E113 BAD CRC - copy uncompressed recovery block code to RAM
E114 BAD CRC - jump to code in RAM
E115 BAD CRC - turn on cache
E116 BAD CRC - copy recovery block data section to RAM
E117 BAD CRC - Invalidate and flush cache, set TOC
E118 BAD CRC - branch to high level recovery control routine.
E119 Initialize base memory, stack
E11A Copy uncompressed recovery block code to RAM
E11B Jump to code in RAM
E11C Turn on cache
E11D Copy recovery block data section to RAM
E11E Invalidate and flush cache, set TOC
E11F Branch to high level control routine.
E120 Initialize I/O and early memory block
E121 Initialize S.P.
E125 Clear PCI devices command reg, go forth
E126 Check valid image - start
E127 Check valid image - successful
E128 Disable interrupts, set int vectors for O.F.
E129 Validate target RAM address
E12A copy to RAM, flush cache
E12B Set MP operational parameters
E12C Set MP cpu node characteristics
E12D Park secondary processors in parking lot
E12E Primary processor sync
E12F Unexpected return from Open Firmware (system lockup)
E130 Build device tree
E131 Create ROOT node
E132 Create cpus node
E133 Create L2 Cache node
E134 Create memory node
E135 Create memory DIMM node
E136 Test memory
E137 Create openprom node
E138 Create options node
E139 Create aliases node and system aliases
E13A Create packages node
E140 PReP style load
E149 Create boot mgr node
E14C Create terminal-emulator node
E14D Loading boot image
E14E Create client interface node/directory
E14F NVRAM initialization
E150 Create host (primary) PCI controller node
E151 Probing primary PCI bus
E152 Probing for adapter FCODE, evaluate if present
E153 End adapter FCODE, probe/evaluate
E154 Create PCI bridge node
E155 Probing PCI bridge secondary bus
E156 Create PCI ethernet node
E15A Create 64 bit host (primary) PCI controller node
E15B Transferring control to Operating System (service mode boot)
E15C Probe primary 64 bit PCI bus
E15D Create host PCI controller node
E15E Create MPIC node
E15F Adapter VPD probe
E160 CPU node VPD creation
E161 Create memory VPD
E162 SP node VPD creation
E163 Create CPU VPD
E164 Create PCI graphic node (P9)
E165 Create planar-clock VPD
E166 Create CEC VPD
E167 Create 7 EIA-Unit I/O Drawer VPD
E168 Create PCI graphic node (S3)
E169 Create 10 EIA-Unit I/O Drawer VPD
E170 Start of PCI Bus Probe
E171 Executing PCI-Delay function
E174 Establishing host connection (incorrect IP parameter)
E175 BootP request Refer checkpoint E174.
E176 TFTP file transfer
E177 Transfer failure due to TFTP error condition
E178 Create PCI token ring node
E180 Service Processor Command setup
E181 Send drawer data to I/O planar
E182 Request 10 EIA-Unit I/O Drawer I/O planar VPD
E183 Service Processor Post
E184 Request 10 EIA-Unit I/O Drawer drawer interface panel VPD
E185 Add 10 EIA-Unit I/O Drawer drawer interface panel VPD to NVram and device tree
E186 Request PS1 VPD
E187 Add PS1 VPD to NVRAM and device tree
E188 Request PS2 VPD
E189 Add PS2 VPD to NVRAM and device tree
E18A Request fan monitoring card VPD
E18B Add fan monitoring card VPD to NVRAM and device tree
E18C VPD and data communications with I/O planar complete
E190 Create ISA node
E191 Create ISA reserved node
E193 Initialize Super I/O
E196 Probe ISA bus
E19B Create Service Processor node
E19C Create tablet node
E19D Create nvram node
E19E Real time clock (RTC) initialization Refer to error code
28030xxx in "Firmware/POST
Error Codes".
E1AD See description of checkpoint E1DE
E1B0 Create lpt node
E1B1 Create serial node
E1B2 Create audio node
E1B3 Create 8042 node
E1B6 Probe for (ISA) keyboard
E1BA Enable L2 cache
E1BB Set cache parms for burst
E1BC Set cache parms for 512KB
E1BD Probe for (ISA) mouse
E1BE Create op-panel node
E1BF Create pwr-mgmt node
E1C0 Create ISA ethernet node
E1C5 Create ISA interrupt controller (pic) node
E1C6 Create DMA node
E1D0 Create PCI SCSI node
E1D3 Create (* wildcard *) SCSI block device node (SD)
E1D4 Create (* wildcard *) SCSI byte device node (ST)
E1DB Create floppy controller (fdc) node
E1DC Dynamic console selection. (maybe cable or keyboard)
E1DD Early processor exception
E1DE Alternating pattern of E1DE and E1AD is used to
indicate a Default Catch condition
before the firmware "checkpoint"
word is available.
E1DF Create diskette drive (disk) node
E1E0 Program flash
E1E1 Flash update complete
E1E2 Initialize System I/O
E1E3 PReP boot image initialization.
E1E4 Initialize Super I/O with default values
E1E5 XCOFF boot image initialization
E1E6 Set up early memory allocation heap
E1E7 PE boot image initialization
E1E8 Initialize primary diskette drive (polled mode)
E1E9 ELF boot image initialization
E1F0 Start O.B.E.
E1F1 Begin self test sequence on boot device(s) Begin SMS.
E1F2 Power-On Password prompt.
E1F3 Privileged-Access Password prompt
E1F5 Build boot device list
E1F6 Determine boot device sequence
E1F7 No boot image located
E1FB Scan SCSI bus for attached devices
E1FD The operator panel will alternate between the code E1FD
and another Exxx code, where
Exxx is the point at which the error occurred.
E440 Validate nvram, initialize partitions as needed. Verify that
the system firmware levels are at the
current release levels, update
as necessary.
Replace Service Processor Card
E441 Generate /options node nvram configuration variable properties
E442 Validate nvram partitions
E443 Generate nvram configuration variable dictionary words.
Suspect a system firmware problem
E500 Configure Remote I/O subsystem
E5xy (E511 - E5FF)
Where x is not equal to 0, and y is not equal to 0. Configure Remote I/O subsystem
components
The E5xy (E511 to E5FF) codes are reserved for
activities relating to configuration or testing of the I/O subsystem, or remote I/O subsystem. A hang at one
of these codes implies that
a severe error occurred during the programming of I/O subsystem registers or
when interacting with adapters plugged into the system. The last two digits in the checkpoint can be
used to help isolate the location of the I/O activity that caused the problem.
"x" indicates the I/O drawer number. "y" indicates the
PCI bus occurance.
If x=_, then the I/O Drawer is:
X = I/O Drawer
1 = 0
2 = 1
3 = 2
4 = 3
If y=_, then the PCI Bus is:
Y = PCI Bus
1 = 0
2 = 1
3 = 2
4 = 3
Base Level Error Codes
________________________________________________________
Digit 1 ³ Digit 2 ³ Digit 3 | Type of Failure
blank ³ blank | blank | None
8 ³ | | Fan P49B
4 ³ | | Fan P49C.
u ³ | | = Digit 1 Codes 8 and 4.
³ 8 | | Fan at P47.
³ 4 | | Fan P46A or P46 or both.
³ 2 | | Fan P49A.
| 6 | | = Digit 2 Codes 4 and 2.
| c | | = Digit 2 codes 8 and 2.
| u | | = Digit 2 codes 8 and 4.
|Inverted F| | = Digit 2 codes 8, 4 and 2.
| | 8 | Excessive temperature in PS
| | 4 | Power failure in PS
| | 2 | Power failure outside PS
| | 1 | Loss of primary power.
Service Request Number List for Multiple Bus Systems
Replace FRU parts in the order by which the "Failing Function Codes" are listed.
Service Failing Description and Action
Request Function (Unless otherwise indicated use Chapter 12.
Number Codes "MAP 0210: General Problem Resolution".)
SRN
Src.
10112 Description: Format Degraded. A Format
operation has been ended before it has completed.
Action: Refer to the Service Guide for the
unit containing the disk drive.
1XXXX Description: Disk drive module error.
Action: Refer to the Service Guide for the
unit containing the disk drive.
Note: In this SRN, an X represents a digit
0 through F.
20PAA Description: An open SSA loop has been detected.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
21PAA Description: An SSA 'Threshold exceeded'
to link error has been detected.
29PAA Action: Go to the Intermittent Link Error
MAP in the SSA Adapters: User's Guide and
Maintenance Information.
2A002 Description: Async code 02 has been
received. Probably, a software error has occurred.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2A003 Description: Async code 03 has been
received. Probably, a software error has occurred.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2A004 Description: Async code 04 has been
received. Probably, a software error has occurred.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2A005 Description: Async code 05 has been
received. This code indicates that a disk
drive module has detected the loss of
redundant power or cooling.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2A006 Description: Async code 06 has been
received. This code indicates that a disk
drive module has detected the loss of
redundant power or cooling.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2A106 Description: Async code 06 has been
received. This code indicates that multiple
disk drive modules have detected the loss
of redundant power or cooling.
Action: Refer to the user's or service
guide for the unit containing the disk drives.
2A206 Description: A disk drive module has
detected that one of its SSA links has
failed the POST.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
2FFFF Description: An async code that is not
valid has been received.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
300C0 Description: A disk drive module has
detected the loss of redundant power or cooling.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
301C0 Description: Multiple disk drive modules
have detected the loss of redundant power or cooling.
Action: Refer to the user's or service
guide for the unit containing the disk drives.
303FF Description: An SCSI status that is not
valid has been received.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
31000 Description: The disk drive has been
reset by the adapter. The disk drive might
be going to fail.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
40000 Description: The SSA adapter card has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40004 Description: A 4MB DRAM module in adapter
card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40008 Description: An 8MB DRAM module in
adapter card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40016 Description: A 16MB DRAM module in
adapter card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40032 Description: A 32MB DRAM module in
adapter card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40064 Description: A 64MB DRAM module in
adapter card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
40128 Description: A 128MB DRAM module in
adapter card slot 0 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41004 Description: A 4MB DRAM module in adapter
card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41008 Description: An 8MB DRAM module in
adapter card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41016 Description: A 16MB DRAM module in
adapter card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41032 Description: A 32MB DRAM module in
adapter card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41064 Description: A 64MB DRAM module in
adapter card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
41128 Description: A 128MB DRAM module in
adapter card slot 1 has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42000 Description: The SSA adapter has detected
that both DRAM modules are failing.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42200 Description: Other adapters on the SSA
loop are using levels of microcode that are
not compatible.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42500 Description: An SSA adapter has detected
a failure in its fast-write cache.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42510 Description: Not enough DRAM available to
run an SSA fast-write cache.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42515 Description: An SSA adapter is attempting
to use its fast-write cache, but a
fast-write cache card is not installed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42520 Description: An SSA fast-write cache
failure has been detected.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42521 Description: An SSA fast-write cache
failure has been detected.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42522 Description: An SSA fast-write cache
failure has been detected.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42523 Description: A incorrect version number
has been detected in an SSA resource.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42524 Description: An SSA write-cache resource
is not available.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42525 Description: An incorrect SSA write-cache
resource has been identified.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42526 Description: This adapter does not
support the SSA Fast-Write Cache Option.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42527 Description: A dormant SSA fast-write
cache entry exists.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
42528 Description: A fast-write SSA disk drive
has been detected that was previously
unsynchronized, but has since been
configured on a different adapter.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
43PAA Description: An SSA device on the loop is
preventing the completion of the loop configuration.
Action: Refer to the user's or service
guide for the unit containing the device.
44PAA Description: A disk drive module has a
'Failed' status.
Action: Refer to the Service Guide for the
unit containing the disk drive.
45PAA Description: The SSA adapter has detected
an open SSA loop. This problem is caused
either by a disk drive module that is
failing, or by a disk drive module that has
been turned off from another using system
on the same SSA loop. (That using system
has itself been turned off.)
Action: Refer to the user's or service
guide for the unit containing the disk drive.
46000 Description: A RAID array is the Offline
state because more than one disk drive is
not available. At least one member disk
drive of the array is present, but more
than one member disk drive is missing.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
46500 Description: A member disk drive is
missing from a SSA array.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
47000 Description: An attempt has been made to
store in the SSA adapter the details of
more than 32 RAID arrays.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
47500 Description: Part of the RAID array data
might have been lost.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48000 Description: The SSA adapter has detected
a link configuration that is not valid.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48600 Description: Member disk drives of an SSA
array are not all on the same SSA loop, in
a multiple-host-system configuration.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48700 Description: Two or more member disk
drives of an SSA array are on different loops.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48800 Description: The SSA RAID strip table is not valid.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48900 Description: An SSA array is not
available; a multiple-device error has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
48950 Description: An SSA disk drive has failed
during a building operation.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
49000 Description: A RAID array is in the
Degraded state because a disk drive is not
available to the array, and a write command
has been sent to that array.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
49100 Description: A RAID array is in the
Exposed state because a disk drive is not
available to the array.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
49500 Description: No hot spare disk drives are
available for a RAID array that is
configured for hot spare disk drives.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
49700 Description: The parity for the RAID
array is not complete.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
4A100 Description: The adapter cannot
initialize an SSA disk drive.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
4BPAA Description: An SSA disk drive at PAA
cannot be configured, because its UID
cannot be read.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50000 Description: The SSA adapter failed to
respond to the device driver.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50001 Description: A data parity error has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50002 Description: An SSA adapter DMA error has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50004 Description: Channel check.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50005 Description: A software error has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50006 Description: A channel check has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50007 Description: The IOCC detected an
internal error.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50008 Description: Unable to read or write the
POS registers.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50010 Description: An SSA adapter or
device-driver protocol error has occurred.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50012 Description: The SSA adapter microcode has hung.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50013 Description: The SSA adapter card has failed.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50100 Description: An attempt was made to log
an error against a pdisk that is not
available to the using system.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50200 Description: Duplicate SSA cluster number detected.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50411 Description: SSA adapter has detected an
SS_SIC_CLASS1 error.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
50425 Description: SSA adapter has detected an
SS_LINK_CONFIG_FAILED error.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
504XX Description: The SSA adapter microcode has hung.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
60000 Description: The SSA adapter is missing
from the expected configuration.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
60200 Description: The SSA unit cannot be turned on.
Action: Refer to the Service Guide for the unit.
60210 Description: A disk drive module has its
Check light on.
Action: Refer to the Service Guide for the
unit containing the disk drive.
60220 Description: A fan-and-power-supply
assembly has its Check light on.
Action: Refer to the Service Guide for the
unit containing the device that the error
was reported against.
60230 Description: The SSA unit has an
unexpected Check light on.
Action: Refer to the Service Guide for the unit.
60240 Description: An SSA configuration problem
has occurred. An SSA device cannot be configured.
Action: Refer to the Service Guide for the
unit containing the device.
7XXXX Description: An SSA disk drive is missing
from the expected configuration of the SSA loop.
Action: Refer to the user's or service
guide for the unit containing the disk
drive.Note: In this SRN, an X represents a digit
0 through F.
D0000 Description: The using system cannot
configure the disk drive module.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0100 Description: Unable to clear a disk drive
module reservation.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0101 Description: The disk drive module has
been reserved since the diagnostics started.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0200 Description: The disk drive module timed
out while the diagnostics were running.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0300 Description: The disk drive module failed
the diagnostic test.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0400 Description: The disk drive module is not
ready while the diagnostics are running.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0450 Description: The Format operation that
was started on this disk drive module has
not yet finished.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D0460 Description: A Format operation has been degraded.
Action: Refer to the user's or service
guide for the unit containing the disk drive.
D4000 Description: The diagnostics cannot
configure the SSA adapter.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
D4100 Description: The diagnostics cannot open
the SSA adapter.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
D4300 Description: The diagnostics have
detected an SSA adapter POST failure.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
D44XX Description: The diagnostics have
detected that the SSA adapter has corrupted
the microcode, but cannot download a new
version of the microcode.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
Note: In this SRN, an X represents a digit
0 through F.
DFFFF Description: A command or parameter that
has been sent or received is not valid.
This problem is caused either by the SSA
adapter, or by an error in the microcode.
Action: Refer to the SSA Adapters: User's
Guide and Maintenance Information.
101-000 A Description: The system hung while
attempting to configure a device.
Action: Use MAP 1540.
101-185 A Description: A checkstop occurred.
Action: Use MAP 1540 in the system unit
service guide to isolate the cause.
101-517 A Description: The system unit failed to IPL.
Action: Use MAP 1540.
101-518 A Description: CD-ROM read problems after boot.
Note:The boot record was read from the
CD-ROM disk. However, errors occurred when
trying to mount the CD-ROM file system.
This problem can be caused by SCSI device
addressing, SCSI terminator, open PTC, SCSI
cable, etc.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure"
Description: The configuration manager
101-521 A detected an error.
to Action: If you are running the diagnostics
101-538 from a disk, try running the diagnostics
from a CD-ROM. If the diagnostics run
correctly from CD-ROM, the problem may be
damaged data on the disk. Contact your
software support facility. If a different
problem occurs when you run the diagnostics
from CD ROM, correct that problem. If you
were running from a CD ROM at first, or
have the same problem on CD ROM that you
had when running diagnostics from disk then
go to MAP 1540, in either the service guide
or the installation and service guide for
this system unit.
101-544 A Description: Disk read problems occurred after booting.
errors occurred when trying to open the
disk drive. This problem can be caused by
SCSI device addressing, SCSI terminator,
open PTC, SCSI cable, etc.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure"
101-551 A Description: The system hung while
loading the software. This can be caused by
to a hardware or software problem.
101-557 Action: Run the diagnostics from CD-ROM.
Start at Chapter 4. "MAP 0020: Problem
Determination Procedure", Step 14. If the
diagnostics run correctly from CD-ROM, the
problem may be damaged disk data. Consider
having the customer contact Software
Support before reinstalling the operating
system on the disk. If you still get the
same SRN, go to MAP 1540 in either the
service guide or the installation and
service guide for this system unit.
Description: There is not enough memory
101-558 A to execute diagnostics.
Action: There must be a minimum of 16MB of
installed memory. If the system has 16MB or
more of memory installed, suspect a problem
with a memory card.
101-559 A Description: The system halted while
software was loading. This problem may be
to attributed to either hardware or software.
Action: Use the CD ROM based diagnostics if
101-599 not yet used. If the same SRN is generated
from the CD ROM diagnostics, go to MAP 1540
in the system unit service guide for
problem isolation.
If the SRN is not generated when using the
CD ROM, suspect a problem with the system's software.
101-711 A xxx Description: The system hung while trying
to configure an unknown resource.
to Action: Run diagnostics from CD-ROM. Start
101-726 at Chapter 4. "MAP 0020: Problem
Determination Procedure", Step 14. If you
still get the same SRN, refer to "Failing
Function Code List" and find the FFC that
matches the last three digits of the SRN.
Suspect the device adapter or device
itself. If more than one adapter or device
is installed, isolate the failing resource
by removing the adapters or devices one at
a time and checking if the system stops
with the same value in the three-digit
display.Note: xxx corresponds to the last three
digits of the SRN.
101-727 A Description: The system hung while trying
to configure an asynchronous adapter.
Action: Use MAP 1540 in the installation
and service guide for this system unit.
Suspect a problem with one of the async adapters.
101-7C1 A 7C1 Description: The system unit halted while
configuring an audio subsystem.
101-888 A 210 Description: The system does not IPL.
Action: Use Chapter 16. "MAP 0260: System
227 Hangs During Resource Configuration".
101-c32 D E10 Description: The system hung while
indicating that a direct-attached display
was selected as the console.
Action: Go to MAP 1540 in either the
service guide or the installation and
service guide for this system unit. Suspect
the graphics adapter being used for the
display console first.
101-c33 D Description: The system hung while
indicating that a TTY terminal is the
system console.
Action: Go to MAP 1540 in either the
service guide or the installation and
service guide for this system unit. Suspect
the graphics adapter being used for the
display console first.
101-xxx A xxx Description: The system hung while
configuring a resource. The last three
227 digits identify the failing function code
for the resource being configured.
Action: Use Chapter 16. "MAP 0260: System
Hangs During Resource Configuration".
103-151 D 151 Description: The time-of-day battery failed.
103-202 H Description: Unexpected interrupt.
to Action: Go to MAP 1540 in either the
103-210 service guide or the installation and
service guide for this system unit.
109-200 B Description: The system crashed while
being run by the customer.
Action: Use Chapter 4. "MAP 0020: Problem
Determination Procedure", and get a new SRN.
110-101 C Description: The diagnostics did not
detect an installed resource.
Action: If this SRN appeared when running
concurrent diagnostics, then run concurrent
using the diag -a command, otherwise use
Chapter 18. "MAP 0290: Missing Resource
Problem Resolution".
110-908 D 908 Description: The system halted while
diagnostics were executing.
110-921 D Description: The system halted while
to xxx diagnostics were executing.
110-926 812 Note: xxx corresponds to the last three
digits of the SRN.
110-935 D 935 Description: The system halted while
diagnostics were executing.
110-946 D 946 Description: The system halted while
diagnostics were executing.
110-xxx D Description: The system halted while
xxx diagnostics were executing.
221 Note: xxx corresponds to the last three
digits of the SRN. If your 110 SRN is not
listed below, use the 110-xxx procedure.
111-259 B Description: Cannot display readable
information on the terminal.
Action: Use Chapter 17. "MAP 0280: Boot
Problem Resolution" Entry 3.
111-725 B 725 Description: Cannot display readable
information on the display.
Note: Suspect the display adapter attached
to the console display.
Action: Use Chapter 17. "MAP 0280: Boot
Problem Resolution"
111-736 B 736 Description: The keyboard does not respond.
821 Action: Use Chapter 17. "MAP 0280: Boot
Problem Resolution" Entry 1.
111-78C B PCI adapter Description: I/O bus problem.
Action: Use Chapter 12. "MAP 0210: General
Problem Resolution".
E10 Note: PCI adapter refers to the adapters
you made note of when using Chapter 11.
"MAP 0080 System Bus Problem Isolation".
111-82C B Description: Cannot display readable
information on the display.
Action: Go to Chapter 17. "MAP 0280: Boot
Problem Resolution" Entry 2.
111-922 B 922 Description: The keyboard does not respond.
111-923 B 923 Description: The keyboard does not respond.
111-947 B 221 Description: System beeper not functioning correctly.
111-999 D 210 Description: System does not perform a soft reset.
2E6-212 D 2E6 Description: FIFO empty bit set.
2E6-213 D 2E6 Description: FIFO empty bit clear.
2E6-214 D 2E6 Description: FIFO full bit set.
2E6-215 D 2E6 Description: FIFO full bit clear.
2E6-216 D 2E6 Description: FIFO data miscompare.
2E6-217 D 2E6 Description: SCSI FIFO data miscompare.
2E6-218 D 2E6 Description: SCSI FIFO underflow.
2E6-219 D 2E6 Description: SCSI parity error.
2E6-220 D 2E6 Description: SCSI FIFO flags error.
2E6-221 D 2E6 Description: Miss compare during the
write/read of the configuration register.
2E6-222 D 2E6 Description: Error during the write/read
of the memory register.
2E6-223 D 2E6 Description: Miss compare during the
write/read of the memory I/O register.
2E6-224 D 2E6 Description: Error reading the PCI
configuration register.
2E6-225 D 2E6 Description: Adapter POST failed.
2E6-230 D D50 Description: Arbitration test failed.
2E6-231 D D50 Description: Function could not complete.
2E6-232 D D50 Description: SCSI bus data miss compare.
2E6-240 D 2E6 Description: No terminal power.
2E6-301 D 2E6 Description: Configuration open failed for
parent bus. SOFTWARE
2E6-700 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-701 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-702 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-703 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-704 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-705 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter failure. Software
2E6-800 G 2E6 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
2E6-802 G 2E6 Description: Error log analysis indicates
a PCI SCSI bus failure.
2E7-212 D 2E7 Description: FIFO empty bit set.
2E7-213 D 2E7 Description: FIFO empty bit clear.
2E7-214 D 2E7 Description: FIFO full bit set.
2E7-215 D 2E7 Description: FIFO full bit clear.
2E7-216 D 2E7 Description: FIFO data miscompare
2E7-217 D 2E7 Description: SCSI FIFO data miscompare.
2E7-218 D 2E7 Description: SCSI FIFO underflow.
2E7-219 D 2E7 Description: SCSI parity error.
2E7-220 D 2E7 Description: SCSI FIFO flags error.
2E7-221 D 2E7 Description: Miscompare during the
write/read of the configuration register.
2E7-222 D 2E7 Description: Error during the write/read
of the memory register.
2E7-223 D 2E7 Description: Miscompare during the
write/read of the memory I/O register.
2E7-224 D 2E7 Description: Error reading the PCI
configuration register.
2E7-225 D 2E7 Description: Adapter POST failed.
2E7-230 D D50 Description: Arbitration test failed.
2E7-231 D D50 Description: Function could not complete.
2E7-232 D D50 Description: SCSI bus data miscompare.
2E7-240 D 2E7 Description: No terminal power.
2E7-301 D 2E7 Description: Configuration open failed for
parent bus. software
2E7-700 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-701 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-702 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-703 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-704 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-705 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
2E7-800 G 2E7 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
2E7-802 G 2E7 Description: Error log analysis indicates
a PCI SCSI bus failure.
2EF-101 E 751 Description: Post indicates an adapter failure.
650-xxx D 650 Description: Disk drive configuration failed.
651-140 D 165 Description: Operator panel display test failed
651-150 D 166 Description: Sensor indicates a fan has failed.
651-151 D 152 Description: Sensor indicates a voltage is
outside the normal range.
651-152 D 2E1 Description: Sensor indicates an
abnormally high internal temperature.
Action: Verify that:
1. The room ambient temperature is within
the system operating environment.
2. There is unrestricted air flow around
the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then
proceed with Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-153 D 152 Description: Sensor indicates a power
supply has failed.
651-159 D Description: Sensor indicates a FRU has
failed.to replace the FRU(s) that are identified
on the diagnostics problem report screen.
651-160 D 166 Description: Sensor indicates a fan is
turning too slowly.
651-161 D 152 Description: Sensor indicates a voltage is
outside the normal range.
651-162 D 2E1 Description: Sensor indicates an
abnormally high internal temperature.
Action: Verify that:
1. The room ambient temperature is within
the system operating environment.
2. There is unrestricted air flow around
the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then
proceed with Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-163 D 152 Description: Sensor indicates a power
supply has failed.
651-169 D Description: Sensor indicates a FRU has
failed the FRUs that are identified on the
diagnostics problem report screen.
651-170 D Description: Sensor status not available.
Action: Contact your support person.
651-171 D Description: Sensor status not available
Action: Contact your support person.
651-600 G Description: Uncorrectable memory or
unsupported memory.
Action: Examine the memory modules and
determine if they are supported types. If
the modules are supported, then replace the
appropriate memory module(s).
651-601 G Description: Missing or bad memory
Action: If the installed memory matches the
reported memory size, then replace the
memory: otherwise, add the missing memory.
651-602 G 2C5 Description: Bad or missing memory
651-603 G 2C6 Description: Bad or missing memory
651-608 G D01 Description: Bad L2 Cache
651-609 G D01 Description: Missing L2 Cache
651-610 G 210 Description: CPU internal error
651-611 G 210 Description: CPU internal cache error
651-612 G D01 Description: L2 Cache parity or multi-bit ECC error
651-613 G D01 Description: L2 cache ECC single-bit error
651-614 G 214 Description: Time-out error waiting for memory controller
651-615 G 292 Description: Time-out error waiting for I/O
651-619 G Description: Error log analysis indicates
an error detected by the CPU. The error log
indicates the following physical FRU
location(s) as the probable cause(s).
Action: Use the physical location codes to
replace the FRUs that are identified on the
diagnostics problem report screen.
651-620 G 2C5 Description: ECC correctable error
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
651-621 G 2C6 Description: ECC correctable error
651-622 G 2C5 Description: Correctable error threshold exceeded
651-623 G 2C6 Description: Correctable error threshold exceeded
651-624 G 214 Description: Memory controller internal error
651-625 G 214 Description: Memory Address (Bad address going to memory)
651-626 G 214 Description: Memory Data error (Bad data going to memory)
651-627 G 214 Description: Memory time-out error
651-628 G 210 Description: Processor time-out error
651-629 G Description: Error log analysis indicates
and error detected by the memory
controller. The error log indicates the
following physical FRU location(s) as the
probable cause(s).
Action: Use the physical location codes to
replace the FRUs that are identified on the
diagnostics problem report screen.
651-630 G 307 Description: I/O Expansion Bus Parity Error.
651-631 G 307 Description: I/O Expansion Bus Time-out Error.
651-632 G 306 Description: Internal Device Error.
651-633 G 307 Description: I/O Expansion Unit not in an
operating state.
651-634 G 307 Description: Internal Device Error.
651-639 G Description: Error log analysis indicates
an error detected by the I/O. The error log
indicates the following physical FRU
location(s) as the probable cause(s).
Action: Use the physical location codes to
replace the FRUs that are identified on the
diagnostics problem report screen.
651-640 G 2D5 Description: I/O general bus error.
651-641 G 2D6 Description: Secondary I/O general bus error
651-642 G 2D3 Description: Internal Service Processor memory error
651-643 G 2D3 Description: Internal Service Processor
firmware error
651-644 G 2D3 Description: Other internal Service
Processor hardware error
651-650 G E17 Description: ECC correctable error.
651-651 G E18 Description: ECC correctable error.
651-652 G 300 Description: ECC correctable error.
651-653 G 301 Description: ECC correctable error.
651-654 G 302 Description: ECC correctable error.
651-655 G 303 Description: ECC correctable error.
651-656 G 304 Description: ECC correctable error.
651-657 G 305 Description: ECC correctable error.
651-660 G E17 Description: Correctable error threshold exceeded.
651-661 G E18 Description: Correctable error threshold exceeded.
651-662 G 300 Description: Correctable error threshold exceeded.
651-663 G 301 Description: Correctable error threshold exceeded.
651-664 G 302 Description: Correctable error threshold exceeded.
651-665 G 303 Description: Correctable error threshold exceeded.
651-666 G 304 Description: Correctable error threshold exceeded.
651-667 G 305 Description: Correctable error threshold exceeded.
651-670 G E17 Description: Bad or missing memory.
651-671 G E18 Description: Bad or missing memory.
651-672 G 300 Description: Bad or missing memory.
651-673 G 301 Description: Bad or missing memory.
651-674 G 302 Description: Bad or missing memory.
651-675 G 303 Description: Bad or missing memory.
651-676 G 304 Description: Bad or missing memory.
651-677 G 305 Description: Bad or missing memory.
651-710 G 214 Description: Address/Data parity error on
Processor bus
651-711 G 214 Description: Address/Data parity error on
Processor bus
651-712 G 214 Description: Address/Data parity error on
Processor bus
651-713 G 214 Description: Transfer error on Processor bus
651-714 G 214 Description: Transfer error on Processor bus
651-715 G 214 Description: Transfer error on Processor bus
651-720 G 2C5 Description: Uncorrectable Memory Error
651-721 G 2C6 Description: Uncorrectable Memory Error
651-722 G 210 Description: Processor bus parity error
651-723 G 210 Description: Processor bus parity error
651-724 G 292 Description: I/O Host Bridge time-out error
651-725 G 292 Description: I/O Host Bridge address/data parity error
651-730 G Description: I/O error on the ISA bus.
651-731 G 2C8 Description: Intermediate or System Bus
Address Parity Error.
651-732 G 2C8 Description: Intermediate or System Bus
Data Parity Error.
651-733 G 214 Description: Intermediate or System Bus
Address Parity Error.
651-734 G 214 Description: Intermediate or System Bus
Data Parity Error.
651-735 G 2D2 Description: Intermediate or System Bus
Time-out Error.
651-736 G 2D2 Description: Intermediate or System Bus
Time-out Error.
651-740 G 2D3 Description: Time-out on communication
response from Service Processor
651-741 G 2D3 Description: Service Processor error
accessing special registers
651-742 G 2D3 Description: Service Processor reports
unknown communication error
651-743 G 2D7 Description: Service Processor error
accessing Vital Product Data EEPROM
651-744 G 165 Description: Service Processor error
accessing Operator Panel
651-745 G 2D9 Description: Service Processor error
accessing Power Controller
651-746 G 2E0 Description: Service Processor error
accessing Fan Sensor
651-747 G 2E1 Description: Service Processor error
accessing Thermal Sensor
651-748 G 2E2 Description: Service Processor error
accessing Voltage Sensor
651-749 G 2E3 Description: Service Processor error
accessing Serial Port 2D4
651-750 G 814 Description: Service Processor error
accessing NVRAM 2D4
651-751 G 817 Description: Service Processor error
accessing Real-Time Clock/Time-of-Day Clock
651-752 G 2E4 Description: Service Processor error
accessing JTAG/COP controller/hardware
651-753 G 151 Description: Service Processor detects
loss of voltage from the Time-of-Day Clock
2D4 backup battery
651-760 G software Description: Service Processor caused a
reboot of the system due to a surveillance
hardware time-out.
Action: A surveillance time-out is caused
by lack of response from the operating
system. The most likely cause is a software
or operating system failure. Verify that
the problem is not related to hardware by
running diagnostics, in Problem
Determination Mode, on all resources which
have not already been run. Also, the system
administrator should look for other
symptoms that would indicate a software or
operating system problem. Contact the
software support structure for assistance
in needed.
651-770 G 2C8 Description: Intermediate or System Bus
Address Parity Error. 292 306
651-771 G 2C8 Description: Intermediate or System Bus
Data Parity Error. 292 306
651-772 G 2D2 Description: Intermediate or System Bus
Time-out Error. 292 306
651-773 G 227 Description: Intermediate or System Bus
Data Parity Error.
651-780 G E17 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
2C7 Problem Resolution". 214
651-781 G E18 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
2C7 Problem Resolution". 214
651-782 G 300 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-783 G 301 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-784 G 302 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-785 G 303 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-786 G 304 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-787 G 305 Description: Uncorrectable Memory Error.
Action: Use Chapter 14. "MAP 0240: Memory
214 Problem Resolution".
651-800 G 166 Description: Fan is turning slower than
expected 2E0
651-801 G 166 Description: Over voltage condition was
detected 2E0
Action: Verify the following:
* nothing is obstructing the fan rotation
* the fan power connection is tight
* the fan speed sensing cable is tight
If the fan still is not turning replace the
fan. If the fan is turning, replace the fan
sensor FRU.
651-810 G 152 Description: Over voltage condition was detected
2E2 Action: Verify that all DC voltages are
within specifications. If all of the
voltages are within specifications, replace
the voltage sensor FRU, otherwise replace
the power supply FRU.
651-811 G 152 Description: Under voltage condition was detected
2E2 Action: Verify that all DC voltages are
within specifications. If all of the
voltages are within specifications, replace
the voltage sensor FRU, otherwise replace
the power supply FRU.
651-812 G 152 Description: System shutdown due to:
1. Loss of AC power
2. Power button was pushed without proper
system shutdown
3. Power supply failure
Action: If reasons 1 and 2 can be ruled out
than replace the power supply FRU.
651-813 G Description: System shutdown due to loss
of AC Power to the site.
Action: System resumed normal operation, no
action required.
651-814 G 152 Description: CEC Rack shutdown due to one
of the following:
1. Loss of AC power to the CEC Rack
2. Open or disconnected SPCN cable
between racks
3. AC module, Bulk power, regulator or
SPCN card failure.
Action: If 1 and 2 can be ruled out and the
problem can be recreated, try the power
supply related FRUs one at a time to
isolate the problem.
651-815 G 287 Description: I/O Rack shutdown due to one
of the following:
289 1. Loss of AC power to the I/O Rack
2. Open or disconnected SPCN cable
between racks
3. Power supply failure
Action: If 1 and 2 can be ruled out, then
replace the power supply FRU.
651-816 G 287 Description: Power fault due to internal
power supply failure.
651-817 G 289 Description: Power fault due to internal
power supply failure.
651-818 G Description: Power fault due to manual
activation of power-off request.
Action: Resume normal operation.
651-820 G 2E1 Description: An over temperature condition
was detected
Action: Verify the following:
* the room ambient temperature is within
the system operating environment
* there is unrestricted air flow around
the system
* all system covers are closed
If all conditions are met, then replace the
temperature sensor FRU.
651-821 G 2E1 Description: System shutdown due to an
over maximum temperature condition being reached.
Action: Verify the following:
* The room ambient temperature is within
the system operating environment.
* There is unrestricted air flow around
the system.
* All system covers are closed.
If all conditions are met, then replace the
temperature sensor FRU.
651-822 G 166 Description: System shutdown due to over
temperature condition and fan failure. Use
2E1 the physical FRU location(s) as the
probable cause(s).
Action: Use the physical location codes to
replace the FRUs that are identified on the
diagnostics problem report screen.
651-830 G 166 Description: Sensor detected a fan failure.
2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-831 G 152 Description: Sensor detected a voltage
outside of the normal range.
2E2 Action: Use MAP 1520.
651-832 G 2E1 Description: Sensor detected an abnormally
high internal temperature.
Action: Verify that:
1. The room ambient temperature is within
the system operating environment.
2. There is unrestricted air flow around
the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then
proceed with Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-833 G 152 Description: Sensor detected a power
supply failure.
E19 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-839 G Description: Sensor detected a FRU that
has failed.
Action: Use the physical location code(s)
to replace the FRU(s) that are identified
on the diagnostics problem report screen.
651-840 G 166 Description: Sensor detected a fan failure.
2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-841 G 152 Description: Sensor detected a voltage
outside of the normal range.
2E2 Action: Use MAP 1520.
651-842 G 2E1 Description: Sensor detected an abnormally
high internal temperature.
Action: Verify that:
1. The room ambient temperature is within
the system operating environment.
2. There is unrestricted air flow around
the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then
proceed with Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-843 G 152 Description: Sensor detected a power
supply failure.
E19 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
651-849 G Description: Sensor detected a FRU that
has failed.
Action: Use the physical location code(s)
to replace the FRU(s) that are identified
on the diagnostics problem report screen.
651-88x G Description: The CEC or SPCN reported an error.
Action: If reference and location codes
were reported with this SRN, refer to this
system unit's system service guide with the
reference and location codes for the
necessary repair action. If the reference
and location codes were NOT reported, then
run Diagnostics in Problem Determination
mode and record and report the reference
and location codes for this SRN.
651-89x G Description: The CEC or SPCN reported an error.
Action: Refer to the this system unit's
system service guide, with the reference
and location codes, for the necessary
repair action. If the reference and
location codes were NOT reported, then run
Advanced Diagnostics in Problem
Determination mode and record and report
the reference and location codes for this SRN
652-600 G Description: A non-critical error has been
detected and corrected: Uncorrectable
memory or unsupported memory.
Action: Schedule deferred maintenance.
Examine the memory modules and determine if
they are supported types. If the modules
are supported, then replace the appropriate
memory module(s).
652-610 G 210 Description: A non-critical error has been
detected and corrected: CPU internal error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-611 G 210 Description: A non-critical error has been
detected and corrected: CPU internal cache error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution"
652-612 G D01 Description: A non-critical error has been
detected and corrected: L2 cache parity or
multi-bit ECC error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-613 G D01 Description: A non-critical error has been
detected and corrected: L2 cache ECC
single-bit error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution"
652-622 G 2C5 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-623 G 2C6 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-630 G 307 Description: A non-critical error has been
detected and corrected: I/O Expansion Bus
Parity Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-631 G 307 Description: A non-critical error has been
detected and corrected: I/O Expansion Bus
Time-out Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-632 G 306 Description: A non-critical error has been
detected and corrected: I/O Expansion Bus
307 Connection Failure.
Action: Schedule deferred maintenance. Use
308 Chapter 12. "MAP 0210: General Problem
Resolution".
652-633 G 307 Description: A non-critical error has been
detected and corrected: I/O Expansion Unit
306 not in an operating state.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-634 G 307 Description: A non-critical error has been
detected and corrected: Internal Device Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-660 G E17 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-661 G E18 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-662 G 300 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-663 G 301 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-664 G 302 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-665 G 303 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-666 G 304 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-667 G 305 Description: A non-critical error has been
detected and corrected: Correctable error
threshold exceeded.
Action: Schedule deferred maintenance. Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
652-731 G 2C8 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Address Parity Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-732 G 2C8 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Data Parity Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-733 G 214 Description: A non-critical error has been
detected and corrected: Intermediate or
2C8 System Bus Address Parity Error.
Action: Schedule deferred maintenance. Use
292 Chapter 12. "MAP 0210: General Problem
Resolution".
652-734 G 214 Description: A non-critical error has been
detected and corrected: Intermediate or
2C8 System Bus Data Parity Error.
Action: Schedule deferred maintenance. Use
292 Chapter 12. "MAP 0210: General Problem
Resolution".
652-735 G 2D2 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Time-out Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-736 G 2D2 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Time-out Error.
Action: Schedule deferred maintenance. Use
214 Chapter 12. "MAP 0210: General Problem
Resolution".
652-770 G 2C8 Description: A non-critical error has been
detected and corrected: Intermediate System
292 Bus Address Parity Error.
Action: Schedule deferred maintenance. Use
306 Chapter 12. "MAP 0210: General Problem
Resolution".
652-771 G 2C8 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Data Parity Error.
Action: Schedule deferred maintenance. Use
306 Chapter 12. "MAP 0210: General Problem
Resolution".
652-772 G 2D2 Description: A non-critical error has been
detected and corrected: Intermediate or
292 System Bus Time-out Error.
Action: Schedule deferred maintenance. Use
306 Chapter 12. "MAP 0210: General Problem
Resolution".
652-773 G 227 Description: A non-critical error has been
detected and corrected. Intermediate or
System Bus Data Parity Error.
Action: Schedule deferred maintenance. Use
Chapter 12. "MAP 0210: General Problem
Resolution".
652-810 G 152 Description: Non-critical power problem,
loss of redundant supply. Use the physical
FRU location(s) as the probable cause(s).
Action: Schedule maintenance. Use the
physical location codes to replace the FRUs
that are identified on the diagnostics
problem report screen.
652-820 G 166 Description: Non-critical cooling problem,
loss of redundant fan. Use the physical FRU
location(s) as the probable cause(s).
Action: Schedule maintenance. Use the
physical location codes to replace the FRUs
that are identified on the diagnostics
problem report screen.
652-830 G 166 Description: Sensor detected a redundant
fan failure.
2E0 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
652-833 G 152 Description: Sensor detected a redundant
power supply failure.
E19 Action: Use Chapter 13. "MAP 0220 Hot Plug
FRU Problem Resolution".
652-839 G Description: Sensor detected a redundant
FRU failure.
Action: Use the physical location code(s)
to replace the FRU(s) that are identified
on the diagnostics problem report screen.
652-88x G Description: The CEC or SPCN reported a
non-critical error.
Action: Schedule deferred maintenance. If
reference and location codes were reported
with this SRN, refer to this system unit's
system service guide with the reference and
location codes for the necessary repair
action. If the reference and location codes
were NOT reported, then run Diagnostics in
Problem Determination mode and record and
report the reference and location codes for
this SRN.
652-89x G Description: The CEC or SPCN reported a
non-critical error.
Action: Schedule deferred maintenance.
Refer to the this system unit's system
service guide, with the reference and
location codes, for the necessary repair
action. If the reference and location codes
were NOT reported, then run Advanced
Diagnostics in Problem Determination mode
and record and report the reference and
location codes for this SRN.
664-098 J 664 Description: IPLROS detected a problem
with the CD-ROM drive B88
664-099 J 664 Description: IPLROS detected a problem
with the CD-ROM drive
664-111 D 664 Description: Unable to reserve device.
664-112 D 664 Description: Unable to do configuration.
664-113 D 664 Description: Unable to open the device driver.
664-121 D 664 Description: The CD-ROM drive indicates an error.
664-122 D 664 Description: The CD-ROM drive indicates an error.
664-123 D 664 Description: The CD-ROM drive indicates an error.
664-125 D 664 Description: The CD-ROM drive indicates an error.
664-126 D 664 Description: The CD-ROM drive indicates an error.
664-127 D 664 Description: The CD-ROM drive indicates an error.
664-128 D 664 Description: The CD-ROM drive indicates an error.
664-129 D 664 Description: The CD-ROM drive indicates an error.
664-150 D Media Description: A media error was detected.
664-151 D 664 Description: A command timeout was detected.
664-152 D 664 Description: A command reservation
conflict was detected.
664-162 D 664 Description: The CD-ROM drive indicates an error.
664-171 D 664 Description: Unable to reserve device.
664-172 D 664 Description: Unable to do configuration.
664-173 D 664 Description: Unable to open device driver.
664-175 D 664 Description: The CD-ROM drive indicates an error.
664-198 D 664 Description: Undefined error detected.
664-199 D 664 Description: Undefined error detected.
664-211 D 664 Description: The LED test failed.
664-281 D 664 Description: No tone during audio test.
664-301 G 664 Description: Errors found during ELA.
664-302 G 664 Description: Errors found during ELA.
669-201 D 669 Description: Configuration register test failure
669-202 D 669 Description: I/O register test failure
669-203 D 669 Description: Adapter memory test failure
669-204 D 669 Description: Adapter initialization test failure
669-205 D 669 Description: Internal loopback test failure
669-206 D 669 Description: External loopback test failure
669-701 G 669 Description: Error log analysis indicates
that this device failed to initialize
because it is not the IBM version of the
adapter. AIX cannot configure the non-IBM
version of this adapter
669-702 G 669 Description: Error Log Analysis indicates
that this device failed to initialize due
221 to a problem with the EEPROM on the adapter.
669-703 G 669 Description: Error Log Analysis indicates
that this device has failed to initialize
221 due to a self-test failure.
669-704 D 669 Description: Error Log Analysis indicates
that this device has failed to initialize
221 due to firmware download error. The
microcode seems to be properly installed.
674-101 D 674 Description: Artic960 PCI Adapter Central
Processing Unit (CPU) test failure.
C94 Action: Use MAP 0210.
674-102 D 674 Description: Artic960 PCI Adapter Timer test failure.
674-103 D 674 Description: Artic960 PCI Adapter Bus Interface test failure.
674-104 D C94 Description: Artic960 PCI Adapter Dynamic
Random Access Memory (DRAM) test failure.
674-105 D 674 Description: Artic960 PCI Adapter Memory
Protection test failure.
674-106 D 674 Description: Artic960 PCI Adapter Debug
Port test failure.
674-107 D C95 Description: Interface board wrap test failure.
674-110 D C94 Description: Artic960 PCI Adapter Download
Diagnostics test failure.
674-123 D C95 Description: Interface board non-wrap test failure.
674-150 D 674 Description: Device configuration failure.
software Action: Use MAP 0210.
674-151 D 674 Description: Device driver indicates a
hardware failure. software 227
674-152 D 674 Description: Failure and error in
determining which type of Artic960 PCI
Adapter. Action: Use MAP 0210.
674-153 D 674 Description: Error log analysis indicates
a Artic960 PCI Adapter failure.
227 Action: Use ERRPT command to check error
log. C94 software
674-154 D C94 Description: Artic960 PCI Adapter
initialization failure.
674-155 D 674 Description: Artic960 PCI Adapter
initialization failure.
674-156 D C95 Description: Artic960 PCI Adapter
initialization failure.
674-157 D C98 Description: Cable wrap test failure.
675-101 D 675 Description: Artic960Hx Adapter Central
Processing Unit (CPU) test failure.
675-102 D 675 Description: Artic960Hx Adapter Timer test failure.
675-103 D 675 Description: Artic960Hx Adapter Bus
Interface test failure.
675-104 D C94 Description: Artic960Hx Adapter Dynamic
Random Access Memory (DRAM) test failure.
675-105 D 675 Description: Artic960Hx Adapter Memory
Protection test failure.
675-106 D 675 Description: Artic960Hx Adapter Debug Port test failure.
675-107 D C95 Description: Interface board wrap test failure.
675-110 D C94 Description: Artic960Hx Adapter Download
Diagnostics test failure.
675-123 D C95 Description: Interface board non-wrap test failure.
675-150 D 675 Description: Device configuration failure.
software Action: Use MAP 0210. 227
675-151 D 675 Description: Device driver indicates a hardware failure.
software Action: Use MAP 0210. 227
675-152 D 675 Description: Failure and error in
determining which type of Artic960Hx
Adapter. Action: Use MAP 0210.
675-153 D 675 Description: Error log analysis indicates
a Artic960Hx Adapter failure.
227 Action: Use ERRPT command to check error log. C94software
675-154 D C94 Description: Artic960Hx Adapter
initialization failure.
675-155 D 675 Description: Artic960Hx Adapter
initialization failure.
675-156 D C95 Description: Artic960Hx Adapter
initialization failure.
675-157 D C98 Description: Cable wrap test failure.
677-201 D 677 Description: Configuration Register test failure
677-202 D 677 Description: Reset test failure
677-203 D 677 Description: Register test failure
677-204 D 677 Description: SRAM test failure
677-205 D 677 Description: Interrupt test failure
677-206 D 677 Description: PCI Loop Back test failure
677-207 D 677 Description: Internal Loop Back test failure 221
677-208 D 677 Description: External Loop Back test failure 221
677-209 D 677 Description: Hub Loop Back test failure xxx
677-301 D 677 Description: I/O Error on Read/Write Operation 221 Software
677-401 F C24 Description: Unisolated Loop Back test failure
xxx Action: Run diagnostics again utilizing the
wrap plug. 677 221
677-701 G 677 Description: Error log analysis indicates
that an error has occurred with the 221 adapter.
677-702 G Microcode Description: Error log analysis indicates
that an adapter microcode error has 677 occurred
678-098 J 678 Description: Tape drive indicates an error.
678-099 J 678 Description: Tape drive not found. B88
678-101 D 678 Description: Timeout while attempting to
communicate with SCSI device.
678-102 D 678 Description: The SCSI device indicates busy.
678-103 D 678 Description: The SCSI device indicates a
reservation conflict.
678-104 D 678 Description: The SCSI device indicates a
check condition.
678-105 D 678 Description: An error is detected in
request sense data.
678-107 D 678 Description: Sense data from the SCSI
drive has unexpected data.
678-110 D 678 Description: The Reserve command failed.
678-111 D 678 Description: Invalid condition from the
drive after a reserve.
678-112 D 678 Description: The write protect sensor test failed.
678-113 D 678 Description: Invalid condition from drive
after a request sense.
678-114 D 678 Description: Timeout while attempting to
communicate with the SCSI device.
678-120 D 678 Description: The Inquiry command failed.
678-130 D 678 Description: The Load command failed.media
678-134 D B88 Description: The adapter failed to configure. software
678-135 D 678 Description: The Unload command failed. media
678-140 D 678 Description: The Mode Select command failed.
678-150 D 678 Description: The Test Unit Ready command failed. media
678-160 D 678 Description: The Send Diagnostic command failed. media
678-161 D 678 Description: Invalid condition from the
drive after a reserve. B88
678-163 D 678 Description: Invalid condition from the
drive after a request sense. B88
678-164 D 678 Description: Timeout while attempting to
communicate with the SCSI device. B88
678-165 D 678 Description: Write, Read and Compare Test failed. B88
678-166 D 678 Description: Unable to configure the device. B88 software
678-167 D 678 Description: An unexpected SCSI error occurred. B88
678-168 D B88 Description: The adapter failed to configure. software
678-169 D 678 Description: The send diagnostic command failed. media
678-170 D 678 Description: The Read, Write and Compare test failed.B88 media
678-180 D 678 Description: The Load command failed. media
678-185 D 678 Description: The Unload command failed. media
678-190 D 678 Description: The Mode Select command failed.
678-200 D 678 Description: The Test Unit Ready command failed. media
678-201 G 678 Description: Error diagnosed from error log analysis. B88
678-210 D 678 Description: The device configuration failed. B88
678-211 D 678 Description: The device open failed.
678-220 D 678 Description: The Release command failed.
678-230 D 678 Description: The Request Sense command failed.
678-240 D 678 Description: The Openx command failed.
678-260 D 678 Description: The device configuration failed.
678-261 D 678 Description: The device open failed.
678-300 D 678 Description: The device configuration failed. software
678-310 D B88 Description: SCSI adapter configuration failed. software
678-320 G 678 Description: Error log analysis indicates a failure. media
678-411 D 678 Description: A reservation conflict
to D 678 occurred.
678-423 B88 software
678-511 D 678 Description: The drive returned bad or
to D 678 non-extended sense data.
678-523 B88
678-611 D 678 Description: An adapter or bus I/O error
to D 678 occurred.
678-623 B88 software
678-711 D 678 Description: A device timeout error
to D 678 occurred.
678-723 B88 software
679-098 J 679 Description: The disk drive indicates an error.
679-099 J 679 Description: The disk drive not found.
679-102 D 679 Description: An unrecoverable media error occurred.
679-104 D 679 Description: The motor failed to restart.
679-105 D 679 Description: The drive did not become ready.
679-106 D 679 Description: The electronics card test failed.
679-108 D 679 Description: The bus test failed.
679-110 D 679 Description: The media format is corrupted.
679-112 D 679 Description: The diagnostic test failed.
679-114 D 679 Description: An unrecoverable hardware error.
679-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
679-117 D 679 Description: A write protect error occurred.
679-118 D 679 Description: A SCSI command time-out occurred. B88
679-120 D 679 Description: A SCSI busy or command error.
679-122 D 679 Description: A SCSI reservation conflict error.
679-124 D 679 Description: A SCSI check condition error occurred.
679-126 D 679 Description: A software error was caused a hardware failure.
679-128 G 679 Description: The error log analysis
indicates a hardware failure.
679-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. B88 software
679-130 G 679 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
679-132 D 679 Description: A disk drive hardware error occurred.
679-134 D B88 Description: The adapter failed to configure. software
679-135 D 679 Description: The device failed to configure. software
679-136 D 679 Description: The certify operation failed to save
679-137 D 679 Description: Unit attention condition has
occurred on the Send Diagnostic command.
681-098 J 681 Description: The disk drive indicates an error.
681-099 J 681 Description: The disk drive not found. B88
681-102 D 681 Description: An unrecoverable media error occurred.
681-104 D 681 Description: The motor failed to restart.
681-105 D 681 Description: The drive did not become ready.
681-106 D 681 Description: The electronics card test failed.
681-108 D 681 Description: The bus test failed.
681-110 D 681 Description: The media format is corrupted.
681-112 D 681 Description: The diagnostic test failed.
681-114 D 681 Description: An unrecoverable hardware error.
681-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
681-117 D 681 Description: A write protect error occurred.
681-118 D 681 Description: A SCSI command time-out occurred. B88
681-120 D 681 Description: A SCSI busy or command error.
681-122 D 681 Description: A SCSI reservation conflict error.
681-124 D 681 Description: A SCSI check condition error occurred.
681-126 D 681 Description: A software error was caused
by a hardware failure. B88
681-128 G 681 Description: The error log analysis
indicates a hardware failure.
681-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. software
681-130 G 681 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
681-132 D 681 Description: A disk drive hardware error occurred.
681-134 D B88 Description: The adapter failed to configure.software
681-135 D 681 Description: The device failed to configure. software
681-136 D 681 Description: The certify operation failed.
681-137 D 681 Description: Unit attention condition has
occurred on the Send Diagnostic command.
682-098 J 682 Description: IPLROS detected a problem
with the CD-ROM drive B88 221
682-099 J 682 Description: IPLROS detected a problem
with the CD-ROM drive B88
682-111 D 682 Description: Unable to reserve device. B88
682-112 D 682 Description: Unable to do configuration. B88
682-113 D 682 Description: Unable to open the device driver. B88
682-121 D 682 Description: The CD-ROM drive indicates an error.
682-122 D 682 Description: The CD-ROM drive indicates an error.
682-123 D 682 Description: The CD-ROM drive indicates an error.
682-125 D 682 Description: The CD-ROM drive indicates an error. B88
682-126 D 682 Description: The CD-ROM drive indicates an error.
682-127 D 682 Description: The CD-ROM drive indicates an error.
682-128 D 682 Description: The CD-ROM drive indicates an error.
682-129 D 682 Description: The CD-ROM drive indicates an error.
682-150 D Media Description: A media error was detected. 682
682-151 D 682 Description: A command timeout was detected. D88
682-152 D 682 Description: A command reservation conflict was detected.
682-162 D 682 Description: The CD-ROM drive indicates an error.
682-171 D 682 Description: Unable to reserve device.
682-172 D 682 Description: Unable to do configuration.
682-173 D 682 Description: Unable to open device driver.
682-175 D 682 Description: The CD-ROM drive indicates an error.
682-198 D 682 Description: Undefined error detected. B88
682-199 D 682 Description: Undefined error detected.
682-211 D 682 Description: The LED test failed.
682-281 D 682 Description: No tone during audio test.
682-301 G 682 Description: Errors found during ELA.
682-302 G 682 Description: Errors found during ELA. B88
685-001 D 685 Description: RGB_SCREEN_USER_FAIL Monitor/cable
685-040 D 685 Description: STATUS_POLL_TIMEOUT_ERROR monitor/cable
685-041 D 685 Description: CRC_POLL_TIMEOUT_ERROR Monitor/cable
685-060 D software Description: SVC_AIDS_INPUT_ERROR 685
685-081 D software Description: LOOP_COUNT_WAS_ZERO 685
685-082 D software Description: INVALID_TU_NUMBER 685
685-0B0 D software Description: ROM test failed 685
685-0B1 D software Description: ROM test failed 685
685-0D0 D software Description: INTERNAL_ERROR_DATA_SIZE_0 685
685-0D1 D software Description: INTERNAL_ERROR_DATA_SIZE_1 685
685-0D2 D software Description: INTERNAL_ERROR_DATA_SIZE_2 685
685-0D3 D software Description: INTERNAL_ERROR_DATA_SIZE_3 685
685-0D5 D software Description: ODM INIT FAILED 685
685-0D6 D software Description: ODM_OBJECT_SEARCH_FAILED 685
685-0D8 D software Description: ODM_GET_OBJECT_FAILED 685
685-0D9 D software Description: ODM_TERM_FAILED 685
685-0DB D software Description: ILLEGAL_RESOLUTION_SPECIFIED
685-0E5 D software Description: AIXGSC_MGA_START_INTERRUPT_FAILED
685-0E6 D software Description: AIXGSC_MGA_STOP_INTERRUPT_FAILED
685-0E7 D software Description: MDD_OPEN_BUS_FAILED
685-0E8 D software Description: MDD_IOCTL_ERROR 685
685-0E9 D software Description: OPEN_RCM_ERROR 685
685-0EA D software Description: IOCTL_GSC_HANDLE_FAILED 685
685-0EB D software Description: AIXGSC_MAKE_GP_FAILED 685
685-0EC D software Description: AIXGSC_UNMAKE_GP_FAILED 685
685-0ED D software Description: DEVICE_BUSY_ERROR 685
685-0EE D software Description: AIXGSC_MGA_SET_DISPLAY_FAILED 685
685-100 D 685 Description: REG_32_BIT_PRTN_ERROR Monitor/cable
685-101 D 685 Description: REG_32_BIT_ADDR_UNIQ_ERROR Monitor/cable
685-102 D 685 Description: REG_8_BIT_PTRN_ERROR Monitor/cable
685-103 D 685 Description: REG_8_BIT_ADDR_UNIQ_ERROR Monitor/cable
685-104 D 685 Description: CRTC_REGS_PTRN_ERROR Monitor/cable
685-105 D 685 Description: CRTC_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-106 D 685 Description: CRTCEXT_REGS_PTRN_ERROR Monitor/cable
685-107 D 685 Description: CRTCEXT_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-108 D 685 Description: RAMDAC_REGS_PTRN_ERROR Monitor/cable
685-109 D 685 Description: RAMDAC_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-10A D 685 Description: PALETTE_REGS_PTRN_ERROR Monitor/cable
685-10B D 685 Description: PALETTE_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-200 D 685 Description: ROM test failed 227
685-201 D 685 Description: ROM test failed 227
685-202 D 685 Description: ROM test failed 227
685-203 D 685 Description: ROM test failed 227
685-204 D 685 Description: ROM test failed 227
685-205 D 685 Description: ROM test failed 227
685-206 D 685 Description: ROM test failed 227
685-207 D 685 Description: ROM test failed 227
685-208 D 685 Description: ROM test failed 227
685-209 D 685 Description: ROM test failed 227
685-20B D 685 Description: ROM test failed 227
685-400 D 685 Description: SGRAM_RED_SCREEN_ERROR Monitor/cable
685-401 D 685 Description: SGRAM_GREEN_SCREEN_ERROR Monitor/cable
685-402 D 685 Description: SGRAM_BLUE_SCREEN_ERROR Monitor/cable
685-403 D 685 Description: SGRAM_WHITE_SCREEN_ERROR Monitor/cable
685-404 D 685 Description: SGRAM_INCREMENTING_SCREEN_ERROR Monitor/cable
685-500 D 685 Description: BLIT_TEST_ERROR_640 x 480 Monitor/cable
685-501 D 685 Description: BLIT_TEST_ERROR_800 x 600 Monitor/cable
685-502 D 685 Description: BLIT_TEST_ERROR_1024 x 768 Monitor/cable
685-503 D 685 Description: BLIT_TEST_ERROR_1280 x 1024 Monitor/cable
685-504 D software Description: INTERNAL_ERROR_DATA_SIZE_4 685
685-600 D 685 Description: DRAW_TEST_ERROR_640 x 480_A Monitor/cable
685-601 D 685 Description: DRAW_TEST_ERROR_800 x 600_A Monitor/cable
685-602 D 685 Description: DRAW_TEST_ERROR_1024 x 768_A Monitor/cable
685-603 D 685 Description: DRAW_TEST_ERROR_1280 x 1024_A Monitor/cable
685-604 D software Description: INTERNAL_ERROR_DATA_SIZE_5 685
685-605 D 685 Description: DRAW_TEST_ERROR_640 x 480_B Monitor/ cable
685-606 D 685 Description: DRAW_TEST_ERROR_800 x 600_B Monitor/cable
685-607 D 685 Description: DRAW_TEST_ERROR_1024 x 768_B Monitor/cable
685-608 D 685 Description: DRAW_TEST_ERROR_1280 x 1024_B Monitor/cable
685-609 D software Description: INTERNAL_ERROR_DATA_SIZE_6 685
685-60A D 685 Description: DRAW_TEST_ERROR_640 x 480_C Monitor/cable
685-60B D 685 Description: DRAW_TEST_ERROR_800 x 600_C Monitor/cable
685-60C D 685 Description: DRAW_TEST_ERROR_1024 x 768_C Monitor/cable
685-60D D 685 Description: DRAW_TEST_ERROR_1280 x 1024_C Monitor/cable
685-60E D software Description: INTERNAL_ERROR_DATA_SIZE_7 685
686-114 D 686 Description: The register verification test failed.
686-124 D 686 Description: The adapter RAM verification test failed.
686-152 D 686 Description: The data wrap communication test failed.
Note: The cable could be defective. The
cable FRU part number is listed along with
the adapter under FFC 686.
686-153 D 686 Description: The modem control line test failed.
686-252 D 686 Description: The data wrap communication test failed.
686-253 D 686 Description: The modem control line test failed.
686-501 D 686 Description: Adapter Reset failed
686-511 D 686 Description: Adapter to host memory test failed(byte tag)
686-512 D 686 Description: Adapter to host memory test failed (word tag)
686-513 D 686 Description: Adapter to host memory test failed (byte pattern)
686-514 D 686 Description: Adapter to host memory test
failed (word pattern test)
686-521 D 686 Description: Adapter BIOS POST CPU failed
686-522 D 686 Description: Adapter BIOS POST Checksum failed
686-523 D 686 Description: Adapter BIOS POST Timer failed
686-524 D 686 Description: Adapter BIOS POST RAM failed
686-526 D 686 Description: Adapter BIOS POST Async Ports failed
686-527 D 686 Description: Adapter BIOS Misc. failed
686-528 D 686 Description: Adapter BIOS Reset failed
686-529 D 686 Description: Adapter BIOS Download failed
686-531 D 686 Description: Adapter BIOS Command failed
686-533 D 686 Description: Adapter BIOS Timer test failed
686-534 D 686 Description: Adapter BIOS RAM test failed
686-541 D 686 Description: Port async internal loopback test failed (general)
686-542 D 686 Description: Port async internal loopback
test failed (no response from the port)
686-551 D 686 Description: Port async external loopback
test failed (general)
686-552 D 686 Description: Port async external loopback
test failed (data signals)
686-553 D 686 Description: Port async external loopback
test failed (control signals)
686-554 D 686 Description: Port async external loopback
test failed (modem signals)
686-555 D 686 Description: Port async external loopback
test failed (no response from port)
686-901 D software Description: An unexpected error occurred
that can be attributed to software or hardware 686
to Action: Run diagnostics from a source other
686-920 than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 686; otherwise, suspect a software
problem.
686-921 D 686 Description: The adapter failed to
configure. software
686-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 686 hardware.
Action: Run diagnostics from a source other
686-924 than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 686; otherwise, suspect a software
problem.
686-925 D 686 Description: The adapter failed to
configure. software
686-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 686 hardware.
Action: Run diagnostics from a source other
686-950 than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 686; otherwise, suspect a software
problem.
687-114 D 687 Description: The register verification test failed.
687-124 D 687 Description: The adapter RAM verification test failed.
687-152 D 687 Description: The data wrap communication test failed.
687-153 D 687 Description: The modem control line test failed.
687-252 D 687 Description: The data wrap communication test failed.
687-253 D 687 Description: The modem control line test failed.
687-144 D 687 Description: The sync line test failed.
687-244 D 687 Description: The sync line test failed.
687-501 D 687 Description: Adapter Reset failed
687-502 D 687 Description: Adapter Fuse failed
687-511 D 687 Description: Adapter to host memory test failed (byte tag)
687-512 D 687 Description: Adapter to host memory test
failed (word tag test)
687-513 D 687 Description: Adapter to host memory test
failed (byte pattern test)
687-514 D 687 Description: Adapter to host memory test
failed (word pattern test)
687-521 D 687 Description: Adapter BIOS POST CPU failed
687-522 D 687 Description: Adapter BIOS POST Checksum failed
687-523 D 687 Description: Adapter BIOS POST Timer failed
687-524 D 687 Description: Adapter BIOS POST RAM failed
687-525 D 687 Description: Adapter BIOS POST Sync Line failed
687-527 D 687 Description: Adapter BIOS Misc. failed
687-528 D 687 Description: Adapter BIOS Reset failed
687-529 D 687 Description: Adapter BIOS Download failed
687-531 D 687 Description: Adapter BIOS Command failed
687-533 D 687 Description: Adapter BIOS Timer test failed
687-534 D 687 Description: Adapter BIOS RAM test failed
687-541 D 687 Description: Port sync internal loopback test failed
687-551 D 687 Description: Port sync external loopback test failed
687-600 D 837 Description: 232RAN status test failed
687-700 D 684 Description: 422RAN status test failed
687-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 687 hardware.
Action: Run diagnostics from a source other
687-920 than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 687; otherwise, suspect a software problem.
687-921 D software Description: The adapter failed to configure. 687
687-922 D software Description: An unexpected error occurred
to that can be attributed to software or
687-924 687 hardware.
Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 687; otherwise, suspect a software problem.
687-925 D 687 Description: The adapter failed to configure. software
687-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 687 hardware.
Action: Run diagnostics from a source other
687-950 than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 687; otherwise, suspect a software
problem.
689-098 j 689 Description: The disk drive indicates an error. B88
689-099 J 689 Description: The disk drive not found. B88
689-102 D 689 Description: An unrecoverable media error occurred.
689-104 D 689 Description: The motor failed to restart.
689-105 D 689 Description: The drive did not become ready.
689-106 D 689 Description: The electronics card test failed.
689-108 D 689 Description: The bus test failed.
689-110 D 689 Description: The media format is corrupted.
689-112 D 689 Description: The diagnostic test failed.
689-114 D 689 Description: An unrecoverable hardware error.
689-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
689-117 D 689 Description: A write protect error occurred.
689-118 D 689 Description: A SCSI command time-out occurred.B88
689-120 D 689 Description: A SCSI busy or command error.
689-122 D 689 Description: A SCSI reservation conflict error.
689-124 D 689 Description: A SCSI check condition error occurred.
689-126 D 689 Description: A software error was caused by a hardware failure.
689-128 G 689 Description: The error log analysis
indicates a hardware failure.
689-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 689 B88 software
689-130 G 689 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
689-132 D 689 Description: A disk drive hardware error occurred.
689-134 D B88 Description: The adapter failed to configure.software
689-135 D 689 Description: The device failed to configure. software
689-136 D 689 Description: The certify operation failed save
689-137 D 689 Description: Unit attention condition has
occurred on the Send Diagnostic command. B88 D50
690-098 J 689 Description: The disk drive indicates an error. B88
690-099 J 690 Description: The disk drive not found. B88
690-102 D 690 Description: An unrecoverable media error occurred.
690-104 D 690 Description: The motor failed to restart.
690-105 D 690 Description: The drive did not become ready.
690-106 D 690 Description: The electronics card test failed.
690-108 D 690 Description: The bus test failed.
690-110 D 690 Description: The media format is corrupted.
690-112 D 690 Description: The diagnostic test failed.
690-114 D 690 Description: An unrecoverable hardware error.
690-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
690-117 D 690 Description: A write protect error occurred.
690-118 D 690 Description: A SCSI command time-out occurred. B88
690-120 D 690 Description: A SCSI busy or command error.
690-122 D 690 Description: A SCSI reservation conflict error.
690-124 D 690 Description: A SCSI check condition error occurred.
690-126 D 690 Description: A software error was caused
by a hardware failure. B88
690-128 G 690 Description: The error log analysis
indicates a hardware failure.
690-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.690 B88 software
690-130 G 690 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
690-132 D 690 Description: A disk drive hardware error occurred.
690-134 D B88 Description: The adapter failed to configure.software
690-135 D 690 Description: The device failed to configure. software
690-136 D 690 Description: The certify operation failed.
690-137 D 690 Description: Unit attention condition has
occurred on the Send Diagnostic command.
691-200 D 691 Description: The ATM 25Mbps Adapter open
test failed.
691-202 D 691 Description: The ATM 25Mbps Adapter
register test failed.
691-203 D 691 Description: The ATM 25Mbps Adapter memory
test failed.
691-204 D 691 Description: The ATM 25Mbps Adapter NVRAM
test failed.
691-205 D 691 Description: The ATM 25Mbps Adapter
interrupt test failed.
691-206 D 691 Description: The ATM 25Mbps Adapter wrap
test failed.
691-210 D 691 Description: The ATM 25Mbps Adapter close
test failed.
691-220 D 691 Description: The ATM 25Mbps Adapter was
not found.
227 Action: Re-install the ATM 25Mbps Adapter
and re-run the test. If the error
continues, use Chapter 12. "MAP 0210:
General Problem Resolution".
691-300 D Wrap Plug Description: The ATM 25Mbps Adapter wrap
test failed.
691 Action: Re-install the wrap plug and re-run
the test. If the error continues, use
227 Chapter 12. "MAP 0210: General Problem
Resolution".
691-700 G 691 Description: Error log analysis reported a hardware error.
692-110 D 692 Description: The Reserve command failed.
692-120 D 692 Description: The Inquiry command failed.
692-130 D 692 Description: The Load command failed. media
692-135 D 692 Description: The Unload command failed.media
692-140 D 692 Description: The Mode Select command failed.
692-150 D 692 Description: The Test Unit Ready command failed. media
692-160 D 692 Description: The Send Diagnostic command failed.media
692-169 D 692 Description: The send diagnostic command failed.media
692-170 D 692 Description: The Read, Write and Compare test failed.media
692-180 D 692 Description: The Load command failed. media
692-185 D 692 Description: The Unload command failed. media
692-190 D 692 Description: The Mode Select command failed.
692-200 D 692 Description: The Test Unit Ready command failed.media
692-210 D 692 Description: The device configuration failed. B88
692-220 D 692 Description: The Release command failed.
692-230 D 692 Description: The Request Sense command failed.
692-240 D 692 Description: The Openx command failed.
692-300 D 692 Description: The device configuration failed.software
692-310 D B88 Description: SCSI adapter configuration failed.software
692-320 G 692 Description: Error log analysis indicates a failure. media
692-411 D 692 Description: A reservation conflict to occurred.
692-423 B88 software
692-511 D 692 Description: The drive returned bad or
to non-extended sense data.
692-523 B88
692-611 D 692 Description: An adapter or bus I/O error
to occurred.
692-623 B88 software
692-711 D 692 Description: A device timeout error
to occurred.
692-723 B88 software
693-100 D 693 Description: Adapter open failed. 227
693-101 D 693 Description: Adapter config register test failed.
693-102 D 693 Description: Adapter reset failed. 227
693-103 D 693 Description: Adapter I/O register test failed.
693-104 D 693 Description: Adapter microcode download test failed.
693-105 D 693 Description: Adapter internal wrap test failed.227
693-106 D 693 Description: Adapter close failed. 227
697-100 D 697 Description: Charm memory write failure software
697-101 D 697 Description: Charm memory read failure software
697-102 D 697 Description: PCI configuration register
write failure software 227
697-103 D 697 Description: Charm software reset failure software
697-104 D 697 Description: Packet memory error software
697-105 D 697 Description: Control memory failure software 227
697-106 D 697 Description: Link-R detected bad parity
697-107 D 697 Description: Suni detected bad parity
697-108 D 697 Description: Suni initialization failure
697-109 D Wrap Plug Description: Loss of light detected in Link test
697 Action: Check wrap plug installation.
697-10B D Wrap Plug Description: External Loopback failed
Action: Check wrap plug installation.
697-10C D 697 Description: Internal Loopback failed software 227
697-10D D 697 Description: DMS failed software
697-1FF D 697 Description: EPROM checksum failed software 227
697-200 D software Description: Klog error 697 227
697-201 D software Description: ASL error 697 227
697-202 D software Description: ODM Initialization error 697 227
697-203 D software Description: Diagnostic configuration failure 697 227
697-205 D software Description: Error in diag open 697 227
697-206 D software Description: Error in releasing adapter 697 227
698-100 D 698 Description: Charm memory write failure software227
698-101 D 698 Description: Charm memory read failure software
698-102 D 698 Description: PCI configuration register write failure software
698-103 D 698 Description: Charm software reset failure software
698-104 D 698 Description: Packet memory error software 227
698-105 D 698 Description: Control memory failure software 227
698-106 D 698 Description: Link-R detected bad parity
698-107 D 698 Description: Suni detected bad parity
698-108 D 698 Description: Suni initialization failure
698-109 D Wrap Plug Description: Loss of light detected inLink test
698 Action: Check wrap plug installation.
698-10B D Wrap Plug Description: External Loopback failed
Action: Check wrap plug installation. 698
698-10C D 698 Description: Internal Loopback failed software 227
698-10D D 698 Description: DMS failed 227 software
698-1FF D 698 Description: EPROM checksum failed software 227
698-200 D software Description: Klog error 698 227
698-201 D software Description: ASL error 698 227
698-202 D software Description: ODM Initialization error 698 227
698-203 D software Description: Diagnostic configuration failure 698 227
698-205 D software Description: Error in diag open 698 227
698-206 D software Description: Error in releasing adapter
699-100 D 699 Description: An error was found on the adapter
699-110 G 699 Description: Error Log analysis indicates
a hardware error.
699-120 D 699 Description: Adapter hardware has caused a
software failure.
700-102 D 700 Description: 1.1GB single-ended disk drive
to problem.
700-114
700-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
700-117 D 700 Description: A write protect error occurred.
700-118 D 700 Description: A SCSI command time-out. B88
700-120 D 700 Description: A SCSI error.
to
700-124
700-126 D 700 Description: A software error was caused by a hardware failure.
700-128 G 700 Description: The error log analysis
indicates a hardware failure.
700-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 700 B88 software
700-130 G 700 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
700-132 D 700 Description: A disk drive hardware error occurred.
700-134 D B88 Description: The adapter failed to configure. software
700-135 D 700 Description: The device failed to configure.software
700-136 D 700 Description: The certify operation failed.
700-137 D 700 Description: Unit attention condition has
occurred on the Send Diagnostic command.
701-102 D 701 Description: 1.1GB 16-bit single-ended
to disk drive problem.
701-114
701-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
701-117 D 701 Description: A write protect error occurred.
701-118 D 701 Description: A SCSI command time-out.
701-120 D 701 Description: A SCSI error.
to
701-124
701-126 D 701 Description: A software error was caused
by a hardware failure.
701-128 G 701 Description: The error log analysis
indicates a hardware failure.
701-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 701 B88 software
701-130 G 701 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
701-132 D 701 Description: A disk drive hardware error occurred.
701-134 D B88 Description: The adapter failed to configure. software
701-135 D 701 Description: The device failed to configure.software
701-136 D 701 Description: The certify operation failed.
701-137 D 701 Description: Unit attention condition has
occurred on the Send Diagnostic command.
702-102 D 702 Description: 1.1GB 16-bit differential
to disk drive problem.
702-114
702-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
702-117 D 702 Description: A write protect error occurred.
702-118 D 702 Description: A SCSI command time-out.
702-120 D 702 Description: A SCSI error.
to
702-124
702-126 D 702 Description: A software error was caused
by a hardware failure.
702-128 G 702 Description: The error log analysis
indicates a hardware failure.
702-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. software
702-130 G 702 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
702-132 D 702 Description: A disk drive hardware error occurred.
702-134 D B88 Description: The adapter failed to configure.software
702-135 D 702 Description: The device failed to configure. software
702-136 D 702 Description: The certify operation failed.
702-137 D 702 Description: Unit attention condition has
occurred on the Send Diagnostic command.
703-102 D 703 Description: 2.2GB single-ended disk drive
to problem.
703-114
703-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
703-117 D 703 Description: A write protect error occurred.
703-118 D 703 Description: A SCSI command time-out.
703-120 D 703 Description: A SCSI error.
to
703-124
703-126 D 703 Description: A software error was caused
by a hardware failure.
703-128 G 703 Description: The error log analysis
indicates a hardware failure.
703-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 703 B88 software
703-130 G 703 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
703-132 D 703 Description: A disk drive hardware error occurred.
703-134 D B88 Description: The adapter failed to configure.Software
703-135 D 703 Description: The device failed to configure. software
703-136 D 703 Description: The certify operation failed.
703-137 D 703 Description: Unit attention condition has
occurred on the Send Diagnostic command.
704-102 D 704 Description: 2.2GB 16-bit single-ended
to disk drive problem.
704-114
704-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
704-117 D 704 Description: A write protect error occurred.
704-118 D 704 Description: A SCSI command time-out.
704-120 D 704 Description: A SCSI error.
to
704-124
704-126 D 704 Description: A software error was caused
by a hardware failure.
704-128 G 704 Description: The error log analysis
indicates a hardware failure.
704-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 704 B88 software
704-130 G 704 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
704-132 D 704 Description: A disk drive hardware error occurred.
704-134 D B88 Description: The adapter failed to configure. software
704-135 D 704 Description: The device failed to configure. B88 software
704-136 D 704 Description: The certify operation failed.
704-137 D 704 Description: Unit attention condition has
occurred on the Send Diagnostic command.
705-102 D 705 Description: 2.2GB 16-bit differential
to disk drive problem.
705-114
705-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
705-117 D 705 Description: A write protect error occurred.
705-118 D 705 Description: A SCSI command time-out.
705-120 D 705 Description: A SCSI error.
to
705-124
705-126 D 705 Description: A software error was caused
by a hardware failure.
705-128 G 705 Description: The error log analysis
indicates a hardware failure.
705-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
705-130 G 705 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
705-132 D 705 Description: A disk drive hardware error occurred.
705-134 D B88 Description: The adapter failed to configure. software
705-135 D 705 Description: The device failed to configure.B88 software
705-136 D 705 Description: The certify operation failed.
705-137 D 705 Description: Unit attention condition has
occurred on the Send Diagnostic command.
706-102 D 706 Description: 4.5GB 16-bit single-ended
to disk drive problem
706-114
706-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
706-117 D 706 Description: A write protect error occurred.
706-118 D 706 Description: A SCSI command time-out.
706-120 D 706 Description: A SCSI error.
to
706-124
706-126 D 706 Description: A software error was caused
by a hardware failure.
706-128 G 706 Description: The error log analysis
indicates a hardware failure.
706-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 706 B88 software
706-130 G 706 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
706-132 D 706 Description: A disk drive hardware error occurred.
706-134 D B88 Description: The adapter failed to configure.software
706-135 D 706 Description: The device failed to configure.B88 software
706-136 D 706 Description: The certify operation failed.
706-137 D 706 Description: Unit attention condition has
occurred on the Send Diagnostic command.
707-102 D 707 Description: Any of the following may have
to occurred: an unrecoverable media error,
707-114 motor failed to restart, the drive did not
become ready, electronics card test failed,
bus test failed, media format failed, or
diagnostic test failed.
707-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
707-117 D 707 Description: A write protect error occurred.
707-118 D 707 Description: A SCSI command time-out.
707-120 D 707 Description: A SCSI error.
to
707-124
707-126 D 707 Description: A software error was caused
by a hardware failure.
707-128 G 707 Description: The error log analysis
indicates a hardware failure.
707-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
707-130 G 707 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
707-132 D 707 Description: A disk drive hardware error occurred.
707-134 D B88 Description: The adapter failed to configure.software
707-135 D 707 Description: The device failed to configure.B88software
707-136 D 707 Description: The certify operation failed.
707-137 D 707 Description: Unit attention condition has
occurred on the Send Diagnostic command.
709-101 D 709 Description: Cannot run the test because
the device driver detected a hardware error.
709-111 D 709 Description: Could not do the test because
the device driver detected a hardware error.
709-112 D 709 Description: Unable to determine the type
of adapter from the VPD.
709-113 D 709 Description: The VPD verification test failed.
709-114 D 709 Description: The register verification test failed.
709-115 D 709 Description: The VPD verification test failed.
709-116 D D57 Description: The 128-port controller line test failed.
709-117 D 684 Diagnostics: Remote Async Node test failed.
709-118 D 837 Description: Remote async node test failed.
709-119 F 709 Description: Sync line termination test failed.
709-151 D 837 Description: Could not perform because the
device driver detected a hardware error.
709-152 D 837 Description: The data wrap communication test failed.
709-153 D 837 Description: The modem control line test failed.
709-154 D 684 Diagnostics: Cannot run the test because
the device driver detected a hardware error.
709-155 D 684 Diagnostics: The data wrap communications test failed.
709-161 D 266 Description: Could not perform because the
device driver detected a hardware error.
709-162 D 266 Description: The data wrap communication test failed.
709-163 D 266 Description: The modem control line test failed.
709-164 D D06 Description: The data wrap communicationtest failed.
709-171 D 259 Description: Could not perform because the
device driver detected a hardware error.
709-172 D 259 Description: The data wrap communication test failed.
709-173 D 259 Description: The modem control line test failed.
709-174 D 263 Description: Cannot run the test because
the device driver detected a hardware error.
709-175 D 263 Description: The data wrap communications test failed.
709-181 D 261 Description: Could not perform because the
device driver detected a hardware error.
709-182 D 261 Description: The data wrap communication test failed.
709-183 D 261 Description: The modem control line test failed.
709-251 D 709 Description: Could not perform because the
device driver detected a hardware error.
709-252 D 709 Description: The data wrap communication test failed.
709-253 D 709 Description: The modem control line test failed.
709-254 D 709 Diagnostics: Cannot run the test because
the device driver detected a hardware error while
running the Remote Async Node wrap test.
709-255 D 709 Diagnostics: The data wrap communications
test failed while running the Remote Async
684 Node wrap test.
709-271 D 709 Description: Could not perform because the
device driver detected a hardware error.
709-272 D 709 Description: The data wrap communication test failed.
709-273 D 709 Description: The modem control line test failed.
709-274 D 709 Diagnostics: Cannot run the test because
the device driver detected a hardware error while
running the Printer/Terminal cable wrap test.
709-275 D 709 Diagnostics: The data wrap communications
test failed while running the
684 Printer/Terminal cable wrap test.
709-281 D 709 Description: Could not perform because the
device driver detected a hardware error.
709-282 D 709 Description: The data wrap communication test failed.
709-283 D 709 Description: The modem control line test failed.
709-481 D D56 Description: Could not do the test because
the device driver detected a hardware error.
709-482 D D56 Description: The data wrap communication test failed.
709-483 D D56 Description: The modem control line test failed.
709-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software
problem.
709-921 D 709 Description: The adapter failed to configure software
709-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software problem.
709-925 D 709 Description: The adapter failed to configure software
709-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 709 hardware.
709-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 709; otherwise, suspect a software problem.
721-102 D 721 Description: Unknown SCSI or device error.
to
721-114
721-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
721-117 D 721 Description: A write protect error occurred.
721-118 D 721 Description: A SCSI command time-out.
721-120 D 721 Description: Unknown SCSI or device error.
to
721-124
721-126 D 721 Description: A software error was caused
by a hardware failure.
721-128 G 721 Description: The error log analysis
indicates a hardware failure.
721-130 G 721 Description: The error log analysis
indicates a hardware failure.
721-132 D 721 Description: A disk drive hardware error occurred.
721-135 D 721 Description: The device failed to configure.B88software
722-xxx D 722 Description: Unknown disk drive type is failing.
723-xxx D 723 Description: Unknown CD-ROM type is failing.
724-xxx D 724 Description: Unknown tape drive failure.
733-110 D 733 Description: The Reserve command failed,
to or the Inquiry command failed.
733-120
733-130 D 733 Description: The Load command failed, or
to the Unload command failed. media
733-135
733-140 D 733 Description: The Mode Select command failed.
733-150 D 733 Description: The Test Unit Ready command
to failed, or the Send Diagnostic command
733-169 media failed.
733-170 D 733 Description: The Read, Write and Compare
test failed. media
733-180 D 733 Description: The Load command failed, or
to the Unload command failed. media
733-185
733-190 D 733 Description: The Mode Select command failed.
733-200 D 733 Description: The Test Unit Ready command media failed.
733-210 D 733 Description: The device configuration failed.
733-220 D 733 Description: 140GB 8mm tape drive failed.
to
733-240
733-300 D 733 Description: The device configuration failed.software
733-310 D B88 Description: SCSI adapter configuration failed.software
733-320 G 733 Description: Error log analysis indicates a failure.media
733-411 D 733 Description: A reservation conflict
to occurred.
733-423 B88 software
733-511 D 733 Description: The drive returned bad or
to non-extended sense data.
733-523 B88
733-611 D 733 Description: An adapter, device, or bus
to I/O error occurred.
733-723 B88 software
734-111 D 734 Description: Unable to reserve device.
734-112 D 734 Description: Unable to do configuration.
734-113 D 734 Description: Unable to open the device driver.
734-121 D 734 Description: The CD-ROM drive indicates an error.
734-122 D 734 Description: The CD-ROM drive indicates an error.
734-123 D 734 Description: The CD-ROM drive indicates an error.
734-125 D 734 Description: The CD-ROM drive indicates an error.
734-126 D 734 Description: The CD-ROM drive indicates an error.
734-127 D 734 Description: The CD-ROM drive indicates an error.
734-128 D 734 Description: The CD-ROM drive indicates an error.
734-129 D 734 Description: The CD-ROM drive indicates an error.
734-150 D Media Description: A media error was detected.
734-151 D 734 Description: A command timeout was detected.
734-152 D 734 Description: A command reservation conflict was detected.
734-162 D 734 Description: The CD-ROM drive indicates an error.
734-171 D 734 Description: Unable to reserve device.
734-172 D 734 Description: Unable to do configuration.
734-173 D 734 Description: Unable to open device driver.
734-175 D 734 Description: The CD-ROM drive indicates an error.
734-198 D 734 Description: Undefined error detected.
734-199 D 734 Description: Undefined error detected.
734-211 D 734 Description: The LED test failed.
734-281 D 734 Description: No tone during audio test.
734-301 G 734 Description: Errors found during ELA.
734-302 G 734 Description: Errors found during ELA.
736-101 D 821 Description: An unexpected adapter error occurred.
736-102 D 736 Description: An unexpected device or
adapter error occurred.
736-103 D 736 Description: The keyboard reset failed.
736-104 D 736 Description: Unknown keyboard.
736-105 D 736 Description: The keyboard light on test failed.
736-106 D 736 Description: The keyboard light off test failed.
736-201 D 821 Description: An unexpected adapter error occurred.
736-202 D 736 Description: An unexpected device or
adapter error occurred.
736-203 D 736 Description: The read keyboard ID test failed.
736-204 D 736 Description: The keyboard layout ID test failed.
736-205 D 736 Description: The keyboard echo test failed.
736-206 D 736 Description: The select scan code set test failed.
736-301 D 821 Description: An unexpected adapter error occurred.
736-302 D 736 Description: An unexpected device or
adapter error occurred.
736-303 D 736 Description: An error occurred in turning
on the lamps.
736-304 D 736 Description: An error occurred in turning
off the lamps.
736-401 D 821 Description: An unexpected adapter error occurred.
736-402 D 736 Description: An unexpected device or
adapter error occurred.
736-403 D 736 Description: Unable to recognize the keyboard.
736-404 D 736 Description: The keyboard is failing.
736-701 D 736 Description: Error configuring the device.
736-901 G 821 Description: The error log analysis
indicates an adapter failure.
736-902 G 736 Description: The error log analysis
indicates a device failure.
736-903 G 736 Description: The error log analysis
indicates an unknown failure.
741-102 D 741 Description: SCSI disk drive problems.
to
741-114
741-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
741-117 D 741 Description: A write protect error occurred.
741-118 D 741 Description: A SCSI command timeout.
741-120 D 741 Description: SCSI disk drive problems.
to
741-124
741-126 D 741 Description: A software error was caused
by a hardware failure.
741-128 G 741 Description: The error log analysis
indicates a hardware failure.
741-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. software
741-130 G 741 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
741-132 D 741 Description: A disk drive hardware error occurred.
741-134 D B88 Description: The adapter failed to configure.software
741-135 D 741 Description: The device failed to configure.B88software
741-137 D 741 Description: Unit attention condition has
occurred on the Send Diagnostic command.
742-101 D 742 Description: Configuration register test failed
742-102 D 742 Description: I/O register test failed
742-104 D 742 Description: Internal loopback test failed
742-105 D 742 Description: Internal loopback test failed
742-106 D 742 Description: External loopback test failed
742-121 D D59 Description: Configuration register test failed
742-122 D D59 Description: I/O register test failed
742-124 D D59 Description: Internal loopback test failed
742-125 D D59 Description: Internal loopback test failed
742-126 D D59 Description: External loopback test failed
742-141 D D60 Description: Configuration register test failed
742-142 D D60 Description: I/O register test failed
742-144 D D60 Description: Internal loopback test failed
742-145 D D60 Description: Internal loopback test failed
742-160 D B08 Description: 10Base-T transceiver test failed
742-161 D B09 Description: 10Base-2 transceiver test failed
742-203 D 742 Description: Device configuration failed software
742-223 D D59 Description: Device configuration failed software
742-224 D B08 Description: 10 Base-T transceiver test failed
742-225 D B09 Description: 10 Base-2 transceiver test failed
742-243 D D60 Description: Device configuration failed software
742-700 G 742 Description: Error log analysis indicates
a hardware problem software
742-720 G D59 Description: Error log analysis indicates
a hardware problem software
742-740 G D60 Description: Error log analysis indicates
a hardware problem software
745-100 D media Description: Recovered error.
Action: No action required.
745-200 D media Description: Drive Not Ready.
Action: Install media, refer to the tape
745 autoloader service guide.
745-300 D media Description: 4mm Tape Auto Loader problem.
to
745-350 745 Action: Replace media, clean drive, refer
to the tape autoloader service guide.
745-400 D 745 Description: General Hardware Failure.
Action: Replace media, clean drive, refer
magazine to the tape autoloader service guide. media
745-410 D 745 Description: Internal Hardware Failure
to Action: Replace drive, refer to the tape
745-435 media autoloader service guide.
745-440 D 745 Description: SCSI Hardware Failure.
Action: Replace drive, refer to the tape
SCSI autoloader service guide. Adapter
745-441 D 745 Description: 4mm Tape Auto Loader problem.
to
745-443 media Action: Replace drive, refer to the tape
autoloader service guide.
745-444 D 745 Description: Humidity too High
Action: Lower humidity, replace media,
environ- refer to the tape autoloader service guide. media
745-445 D clean Description: Drive Requires Cleaning
Action: Clean drive, replace media, refer
media to the tape autoloader service guide. drive
745-460 D 745 Description: Magazine Movement Failure
to Action: Check magazine and media, clean
745-465 magazine rollers, refer to the tape autoloader
service guide. media
745-470 D 745 Description: Media Insert/Eject Failure
to Action: Check clean magazine and media,
745-475 magazine clean rollers, refer to the tape autoloader
service guide. media
745-480 D 745 Description: Drawer Open/Close Failure
to Action: Check magazine and media, refer to
745-485 magazine the tape autoloader service guide. media
745-500 D 745 Description: Illegal request to drive
Action: Software conflict, refer to the
system tape autoloader service guide.
745-600 D 745 Description: Unit Attention
Action: Software conflict, media changed,
system refer to the tape autoloader service guide.
745-700 D 745 Description: Not Writeable
Action: Check media for write protect,
media refer to the tape autoloader service guide.
745-800 D 745 Description: Blank Media
Action: Check media, refer to the tape
media autoloader service guide.
745-B00 D 745 Description: SCSI Interface Failure
Action: Check SCSI interface, refer to the
SCSI tape autoloader service guide. Adapter
745-D00 D 745 Description: Tape Full
Action: Check replace media, refer to the
media tape autoloader service guide.
746-212 D 746 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-213 D 746 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-214 D 746 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-215 D 746 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-216 D 746 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-217 D 746 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-218 D 746 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-219 D 746 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-220 D 746 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-221 D 746 Description: Miscompare during the
write/read of the configuration register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-222 D 746 Description: Error during the write/read
of the memory register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-223 D 746 Description: Miscompare during the
write/read of the memory I/O register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-224 D 746 Description: Error reading the PCI
configuration register.
746-225 D 746 Description: Adapter POST failed.
746-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
746 Problems Isolation Procedure".
746-240 D 746 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
746-301 D 746 Description: Configuration open failed for
parent bus. D50 software
746-700 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-701 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-702 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-703 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-704 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-705 G 746 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
746-800 G 746 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
746-802 G 746 Description: Error log analysis indicates
a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-212 D 747 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-213 D 747 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-214 D 747 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-215 D 747 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-216 D 747 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-217 D 747 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-218 D 747 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-219 D 747 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-220 D 747 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-221 D 747 Description: Miscompare during the
write/read of the configuration register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-222 D 747 Description: Error during the write/read
of the memory register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-223 D 747 Description: Miscompare during the
write/read of the memory I/O register.
221 Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-224 D 747 Description: Error reading the PCI
configuration register.
747-225 D 747 Description: Adapter POST failed.
747-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
747 Problems Isolation Procedure".
747-240 D 747 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
747-301 D 747 Description: Configuration open failed
for parent bus.software
747-700 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-701 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-702 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-703 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-704 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-705 G 747 Description: Error log analysis indicates
a PCI SCSI adapter failure. software
747-800 G 747 Description: Error log analysis indicates
a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
747-802 G 747 Description: Error log analysis indicates
a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
749-xxx D 749 Description: 7331 Model 205 Tape Library.
Refer to service documentation for this device.
750-100 D 750 Description: The adapter open test failed.
750-200 D 750 Description: Config register test failed.
750-201 D 750 Description: I/O register test failed.
750-202 D 750 Description: Adapter self-test failed.
750-300 D 256 Description: The connect test failed.
750-301 D 256 Description: Token-ring internal wrap test failure.
750-302 D 256 Description: Token-ring external wrap failure
750-303 D 256 Description: Token-ring initialization test failure
750-400 D 240 Description: The connect test failed.
750-401 D 240 Token-ring internal wrap test failure
750-402 D 240 Token-ring external wrap test failure
750-403 D 240 Token-ring initialization test failure
750-700 G 750 Description: Error Log analysis indicateda hardware failure.
751-101 D 751 Description: The PCI wrap test failed
751-102 D 751 Description: The POST indicates an adapter failure.
751-103 D 751 Description: The POST indicates an adapter channel failure.
751-104 D Cable Description: The POST indicates a defective cable.
751-105 D Backplane/ Description: The POST indicates a
defective backplane or external enclosure.
Ext.Encl Action: If the disk devices are located in
an external enclosure, refer to the service
documentation for the external enclosure.
751-106 D Disk Description: The POST indicates a disk failure.
751-107 D 751 Description: The POST indicates a firmware failure.
751-108 D 751 Description: The NVRAM test indicates an
adapter firmware failure.
751-109 D 751 Description: The NVRAM test indicates an
adapter failure.
751-110 D Disk Description: The disk reported a
Predictive Failure Analysis error (PFA).
751-111 D Disk Description: The disk drive has been
failed by the adapter.
751-112 G Disk Description: ELA indicates that the disk
reported a irrecoverable equipment error.
751-113 G Disk Description: ELA indicates that the disk
reported a irrecoverable data error.
757-110 D 757 Description: The Reserve command failed.
757-120 D 757 Description: The Inquiry command failed.
757-130 D 757 Description: The Load command failed. media
757-135 D 757 Description: The Unload command failed. media
757-140 D 757 Description: The Mode Select command failed.
757-150 D 757 Description: The Test Unit Ready command failed. media
757-160 D 757 Description: The Send Diagnostic command failed. media
757-169 D 757 Description: The send diagnostic command failed. media
757-170 D 757 Description: The Read, Write and Compare test failed. media
757-180 D 757 Description: The Load command failed. media
757-185 D 757 Description: The Unload command failed. media
757-190 D 757 Description: The Mode Select command failed.
757-200 D 757 Description: The Test Unit Ready command failed.media
757-210 D 757 Description: The device configuration failed.
757-220 D 757 Description: The Release command failed.
757-230 D 757 Description: The Request Sense command failed.
757-240 D 757 Description: The Openx command failed.
757-300 D 757 Description: The device configuration failed.software
757-310 D B88 Description: SCSI adapter configuration failed.software
757-320 D 757 Description: Error log analysis indicates a failure. media
757-411 D 757 Description: A reservation conflict
to occurred.
757-423 B88 software
757-511 D 757 Description: The drive returned bad or
to non-extended sense data.
757-523 B88
757-611 D 757 Description: An adapter or bus I/O error
to occurred.
757-623 B88 software
757-711 D 757 Description: A device timeout error
to occurred.
757-723 B88 software
772-098 J 772 Description: Disk drive indicates an error. B88
772-099 J 772 Description: Disk drive not found.
772-102 D 772 Description: An unrecoverable media error.
772-104 D 772 Description: The motor failed to restart.
772-105 D 772 Description: The drive did not become ready.
772-106 D 772 Description: The electronics card test failed.
772-108 D 772 Description: The bus test failed.
772-110 D 772 Description: The media format is corrupted.
772-112 D 772 Description: The diagnostic test failed.
772-114 D 772 Description: An unrecoverable hardware error.
772-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
772-117 D 772 Description: A write protect error occurred.
772-118 D 772 Description: A SCSI command time-out.
772-120 D 772 Description: A SCSI busy or command error.
772-122 D 772 Description: A SCSI reservation conflict error.
772-124 D 772 Description: A SCSI check condition error.
772-126 D 772 Description: A software error was caused
by a hardware failure.
772-128 G 772 Description: The error log analysis
indicates a hardware failure.
772-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 772 B88 software
772-130 G 772 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
772-132 D 772 Description: A disk drive hardware error occurred.
772-134 D B88 Description: The adapter failed to configure.software
772-135 D 772 Description: The device failed to configure.software
772-136 D 772 Description: The certify operation failed.
772-137 D 772 Description: Unit attention condition has
occurred on the Send Diagnostic command.
773-098 J 773 Description: Disk drive indicates an error.
773-099 J 773 Description: Disk drive not found.
773-102 D 773 Description: An unrecoverable media error.
773-104 D 773 Description: The motor failed to restart.
773-105 D 773 Description: The drive did not become ready.
773-106 D 773 Description: The electronics card test failed.
773-108 D 773 Description: The bus test failed.
773-110 D 773 Description: The media format is corrupted.
773-112 D 773 Description: The diagnostic test failed.
773-114 D 773 Description: An unrecoverable hardware error.
773-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
773-117 D 773 Description: A write protect error occurred.
773-118 D 773 Description: A SCSI command time-out.
773-120 D 773 Description: A SCSI busy or command error.
773-122 D 773 Description: A SCSI reservation conflict error.
773-124 D 773 Description: A SCSI check condition error.
773-126 D 773 Description: A software error was caused
by a hardware failure.
773-128 G 773 Description: The error log analysis
indicates a hardware failure.
773-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
773-130 G 773 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
773-132 D 773 Description: A disk drive hardware error occurred.
773-134 D B88 Description: The adapter failed to configure. software
773-135 D 773 Description: The device failed to configure.software
773-136 D 773 Description: The certify operation failed.
773-137 D 773 Description: Unit attention condition has
occurred on the Send Diagnostic command.
774-098 J 774 Description: Disk drive indicates an error.
774-099 J 774 Description: Disk drive not found.
774-102 D 774 Description: An unrecoverable media error.
774-104 D 774 Description: The motor failed to restart.
774-105 D 774 Description: The drive did not become ready.
774-106 D 774 Description: The electronics card test failed.
774-108 D 774 Description: The bus test failed.
774-110 D 774 Description: The media format is corrupted.
774-112 D 774 Description: The diagnostic test failed.
774-114 D 774 Description: An unrecoverable hardware error.
774-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
774-117 D 774 Description: A write protect error occurred.
774-118 D 774 Description: A SCSI command time-out. B88
774-120 D 774 Description: A SCSI busy or command error.
774-122 D 774 Description: A SCSI reservation conflict error.
774-124 D 774 Description: A SCSI check condition error.
774-126 D 774 Description: A software error was caused
by a hardware failure.
774-128 G 774 Description: The error log analysis
indicates a hardware failure.
774-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.774 B88 software
774-130 G 774 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
774-132 D 774 Description: A disk drive hardware error occurred.
774-134 D B88 Description: The adapter failed to configure.software
774-135 D 774 Description: The device failed to configure.software
774-136 D 774 Description: The certify operation failed.
774-137 D 774 Description: Unit attention condition has
occurred on the Send Diagnostic command.
775-001 D 775 Description: "NO" to color panel Monitor
775-002 D 775 Description: "NO" to cursor panel Monitor
775-007 D Info code Description: The EMC_SCROLLING_17_H_TEST failed
775-009 D Info code Description: The EMC_SCROLLING_21_H_TEST failed
775-064 D 775 Description: TRIO64V+_TIMEOUT
775-101 D 775 Description: Color miscompare
775-102 D 775 Description: Clipping error
775-103 D 775 Description: Rectangle fill test failed
775-128 D software Description: MALLOC_ERROR
775-161 D software Description: Loop count value in rules file is zero
775-191 D 775 Description: Red screen error
775-193 D 775 Description: Green screen error
775-1FF D 775 Description: Rectangle fill test failed
775-201 D 775 Description: Color miscompare
775-202 D 775 Description: Clipping error
775-203 D 775 Description: Image transfer across Plane Test failed
775-211 D software Description: INTERNAL_ERROR_DATA_SIZE
775-212 D software Description: INTERNAL_ERROR_NO_ACCESS
775-215 D 775 Description: Black screen error
775-217 D 775 Description: 9 x 7 Cross hatch grid failed.
775-233 D software Description: OPEN_RCM_ERROR
775-234 D software Description: IOCTL_GSC_HANDLE_FAILED
775-235 D software Description: AIXGSC_MAKE_GP_FAILED
775-236 D software Description: AIXGSC_UNMAKE_GP_FAILED
775-237 D software Description: DEVICE_BUSY_ERROR
775-241 D Info code Description: The SCROLLING_17_H_TEST failed.
775-263 D Info code Description: The EMC_SCROLLING_21_H_TEST failed
775-2FF D 775 Description: Image transfer across Plane Test failed
775-301 D 775 Description: A write of "0x00" to the
palette register failed
775-302 D 775 Description: A write of "0x15" to the
palette register failed
775-303 D 775 Description: A write of "0x2A" to the
palette register failed
775-304 D 775 Description: A write of "0x3F" to the
palette register failed
775-305 D 775 Description: The test of the palette
registers failed
775-3FF D 775 Description: The test of the palette
registers failed
775-401 D 775 Description: Frame buffer base address inconsistent
775-402 D 775 Description: VRAM inaccessible
775-403 D 775 Description: Miscompare found in VRAM
775-404 D 775 Description: The test of the VRAM failed
775-447 D 775 Description: Green screen error
775-449 D 775 Description: Blue Screen error
775-471 D 775 Description: 9 x 7 Cross hatch grid failed.
775-473 D 775 Description: 11 x 9 Cross hatch grid failed.
775-495 D Info code Description: The SCROLLING_17_H_TEST failed.
775-497 D Info code Description: The SCROLLING_21_H_TEST failed.
775-4FF D 775 Description: The test of the VRAM failed
775-501 D 775 Description: Color miscompare
775-502 D 775 Description: Clipping error
775-503 D 775 Description: Direct Frame Buffer test failed
775-5FF D 775 Description: Direct Frame Buffer test failed
775-601 D 775 Description: Video Stream Register test failed
775-602 D 775 Description: Video Stream hardware test failed
775-6FF D 775 Description: Video Stream hardware test failed
775-701 D 775 Description: 0 Degree Short Stroke Draw failed
775-702 D 775 Description: 45 Degree Short Stroke Draw failed
775-703 D 775 Description: Blue Screen error, or 90
Degree Short Stroke Draw failed
775-704 D 775 Description: 135 Degree Short Stroke Draw failed
775-705 D 775 Description: White screen error, or 180
Degree Short Stroke Draw failed
775-706 D 775 Description: 225 Degree Short Stroke Draw failed
775-707 D 775 Description: 270 Degree Short Stroke Draw failed
775-708 D 775 Description: 315 Degree Short Stroke Draw failed
775-709 D 775 Description: Short Stroke Vector Function test failed
775-727 D 775 Description: 11 x 9 Cross hatch grid failed.
775-750 D Info code Description: The SCROLLING_21_H_TEST failed.
775-753 D Info code Description: The EMC_SCROLLING_17_H_TEST failed
775-7FE D 775 Description: Short Stroke Vector Function test failed
775-7FF D software Description: Bad vector detected
775-801 D 775 Description: Color for PatBlt thru screen failed
775-802 D 775 Description: Clipping for PatBlt thru screen failed
775-803 D 775 Description: Color for PatBlt Across screen failed
775-804 D 775 Description: Clipping for PatBlt Across screen failed
775-805 D 775 Description: Pattern Fill Across the Plane test failed
775-8FF D 775 Description: Pattern Fill Across the Plane test failed
775-901 D 775 Description: Color miscompare of white boxes detected
775-902 D 775 Description: Clipping error of white boxes detected
775-903 D 775 Description: Color miscompare of color bars detected
775-904 D 775 Description: Clipping error of white boxes detected
775-905 D 775 Description: Color miscompare of white boxes detected
775-906 D 775 Description: Clipping error of white boxes detected
775-907 D 775 Description: Color miscompare of white boxes detected
775-908 D 775 Description: Clipping miscompare of white boxes detected
775-909 D 775 Description: The Area fill test (color bars) failed
775-9FF D 775 Description: The Area fill test (color bars) failed
775-937 D 775 Description: Red screen error
775-959 D 775 Description: White screen error
775-961 D 775 Description: Black screen error
775-A01 D 775 Description: Color miscompare of horizontal top line
775-A02 D 775 Description: Clipping error of horizontal top line
775-A03 D 775 Description: Color miscompare of vertical right line
775-A04 D 775 Description: Clipping error of vertical right line
775-A05 D 775 Description: Color miscompare of horizontal bottom line
775-A06 D 775 Description: Clipping error of horizontal bottom line
775-A07 D 775 Description: Color miscompare of vertical left line
775-A08 D 775 Description: Clipping error of vertical left line
775-A09 D 775 Description: Color miscompare of horizontal center line
775-A0A D 775 Description: Clipping error of horizontal center line
775-A0B D 775 Description: Color miscompare of vertical center line
775-A0C D 775 Description: Clipping error of vertical center line
775-A0D D 775 Description: Reserved
775-A0F D 775 Description: Reserved
775-A10 D 775 Description: Color miscompare of textured top line
775-A11 D 775 Description: Clipping error of textured top line
775-A12 D 775 Description: Line Drawing Function test failed
775-AFF D 775 Description: Line Drawing Function test failed
775-B01 D 775 Description: Rectangle Area Color miscompare detected
775-B02 D 775 Description: Rectangle Area Clip error detected
775-B03 D 775 Description: Clipped Area Horizontal color
miscompare (background line color wrong)
775-B04 D 775 Description: Clipped Area Horizontal clip
miscompare (clip of background line wrong)
775-B05 D 775 Description: Clipped Area Vertical color
miscompare (background line color wrong)
775-B06 D 775 Description: Clipped Area Vertical clip
error (clip of background line wrong)
775-B07 D 775 Description: The clipping function test failed.
775-BFF D 775 Description: The clipping function test failed.
775-C01 D 775 Description: The BIOS read failed.
775-C02 D 775 Description: The BIOS function test failed.
775-CFF D 775 Description: The BIOS function test failed.
775-D01 D 775 Description: The HW cursor function test failed.
775-DFF D 775 Description: The HW cursor function test failed.
776-104 D D46 Description: Connect Test Failure
776-105 D D46 Description: Wrap Test Failure
776-106 D D46 Description: Wrap Test Failure
776-201 D 776 Description: Configuration Register Test Failure
776-202 D 776 Description: I/O Test Failure
776-203 D 776 Description: Adapter On-Card Test Failure
776-204 D 776 Description: Connect Test Failure
776-205 D 776 Description: Wrap Test Failure
776-206 D 776 Description: Wrap Test Failure
776-304 D D46 Description: Connect Wrap Test Failure
776-305 D D46 Description: Wrap Test Failure
776-306 D D46 Description: Wrap Test Failure
776-404 D 240 Description: Connect Test Failure
776-405 D 240 Description: Wrap Test Failure
776-406 D 240 Description: Wrap Test Failure.
776-414 F 240 Description: Connect Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
776-415 F 240 Description: Wrap Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
776-416 F 240 Description: Wrap Test Failure. This
failure occurs if not connected to a
D46 functional Token-Ring network.
Action: Run advanced diagnostics for this
776 resource to obtain correct problem
isolation.
776-702 G 776 Description: ELA indicates a Token-Ring
adapter check.
776-703 G 776 Description: ELA indicates that the
Token-Ring device driver has experienced a
221 DMA failure
776-704 G 776 Description: ELA indicates that the
Token-Ring device driver has experienced a
221 PCI bus failure
776-705 G 776 Description: ELA indicates that the
Token-Ring device driver has seen a
221 Programmed I/O (PIO) failure.
777-201 D 777 Description: Configuration Register Test Failure 221
777-202 D 777 Description: I/O Test Failure 221
777-203 D 777 Description: Adapter initialization test failure 221
777-204 D 777 Description: Internal wrap test failure 221
777-205 D 777 Description: Internal wrap test failure 221
777-206 D 777 Description: External wrap (10Mbps) testfailure 221
777-207 D 777 Description: Internal wrap test failure 221
777-208 D 777 Description: External wrap (100Mbps) test failure
777-701 G 777 Description: Error log analysis indicates
that the adapter is not responding to
221 initialization commands.
777-702 G 777 Description: Error Log Analysis indicates
that the device driver has detected a PIO
221 error which it was unable to correct.
777-703 G 777 Description: Error log analysis indicates
that the adapter has been shut down due to
221 an unrecoverable error.
777-704 G 777 Description: Error Log Analysis indicates
a problem with the EEPROM on the adapter 221
780-101 D 780 Description: Adapter logic test failure 227
780-102 D 780 Description: Adapter logic test failure.
780-109 D 780 Description: Adapter channel Input/Output test failure.
780-113 D 780 Description: Adapter Serial Communication
Controller (SCC) test failure.
780-114 D 780 Description: Adapter logic test failure. 227
780-120 D 780 Description: Adapter could not be detected
or configured. 227 software
780-140 D 271 Description: An error was found with the
X.21 interface adapter cable. 780
780-150 D 272 Description: An error was found with the
X.24 interface adapter cable. 780
780-160 D 273 Description: An error was found with the
X.35 interface adapter cable. 780
780-170 D 780 Description: The adapter hardware failed.
780-180 D 780 Description: The adapter hardware failed.
780-190 D 780 Description: The adapter hardware failed.
780-210 D 780 Description: An error was found on the adapter.185
780-211 D 780 Description: The adapter card POST test failed. 227
780-230 D 780 Description: The adapter card hardware failed.
780-232 D 849 Description: The adapter card hardware failed.227
780-240 D 780 Description: The adapter card hardware failed.
780-250 D 185 Description: An error was found on the adapter.780
780-260 D 780 Description: The adapter card hardware failed.
780-270 D 780 Description: The adapter card hardware failed.
780-280 D 780 Description: The adapter card hardware failed.
780-290 D 780 Description: The adapter card hardware failed.
780-300 G 780 Description: An adapter error was found
during error log analysis.
780-310 G 780 Description: An adapter error was found
during error log analysis. 185
780-320 G 780 Description: An adapter error was found
during error log analysis. 227
780-330 G 780 Description: Error log analysis indicates
a hardware problem. 227
780-400 D 780 Description: A software error was caused
by a hardware failure. 227
780-700 D 780 Description: The adapter failed to configure.227 software
780-720 D 780 Description: Cable wrap test failed.
780-721 D 780 Description: Port wrap test failed.
780-722 D 780 Description: Cable wrap test failed.
781-101 D 781 Description: ROS POST adapter software
initialization error. 227
781-102 D 781 Description: Extended DRAM SIP test failed.
781-103 D 781 Description: ROS checksum test failed.
781-104 D 781 Adapter download diagnostics failed 227
781-105 D 781 Description: Memory size test failed. 227
781-106 D 781 Description: Interface ID test failed. 227
781-107 D 781 Description: EIB ID test failed.227
781-108 D 781 Description: ROS version test failed. 227
781-109 D 781 Description: DUSCC register test failed.
781-111 D 781 Description: DMA register test failed.
781-112 D 781 Description: X.21 PAL test failed.
781-113 D 781 Description: External wrap test failed.
781-114 D 781 Description: Twin tail logic test failed. 227
781-116 D 254 Description: The RS-232 cable wrap test failed.
781-117 D 253 Description: The RS-422A cable wrap test failed.
781-118 D 257 Description: The V.35 cable wrap test failed.
781-119 D 260 Description: The X.21 cable wrap test failed.
781-120 D 781 Description: The adapter was not detected
or could not be configured. test failed.
227 software
781-121 D 781 Description: The 4-port jumper cable
assembly wrap test failed. 227 software
781-200 G 781 Description: The error log analysis
indicates the adapter failed.
781-221 G 781 Description: The error log analysis
indicates the adapter hardware failed. 227
781-231 D 855 Description: No interface card detected. 227
781-501 D B77 Description: The power-on self-test (POST)failed.B69 227
781-502 D B77 Description: The memory module failed.
781-503 D 781 Description: Adapter hardware failure. 227
781-504 D B69 Description: Adapter hardware failure.
781-505 D B71 Description: Adapter hardware failure. B69
781-506 D B72 Description: Adapter hardware failure. B69
781-507 D B73 Description: Adapter hardware failure. B69
781-508 D B74 Description: Adapter hardware failure. B69
781-516 D B77 Description: Adapter Test Failure B69
781-517 D B69 Description: Adapter Test Failure B77
781-720 D 258 4-port multiprotocol cable 781
783-110 D 783 Description: The Reserve command failed.
783-120 D 783 Description: The Inquiry command failed.
783-130 D 783 Description: The Load command failed. media
783-135 D 783 Description: The Unload command failed. media
783-140 D 783 Description: The Mode Select command failed.
783-150 D 783 Description: The Test Unit Ready command failed.media
783-160 D 783 Description: The Send Diagnostic command failed.media
783-169 D 783 Description: The send diagnostic command failed.media
783-170 D 783 Description: The Read, Write and Compare test failed.media
783-180 D 783 Description: The Load command failed. media
783-185 D 783 Description: The Unload command failed. media
783-190 D 783 Description: The Mode Select command failed.
783-200 D 783 Description: The Test Unit Ready command failed.media
783-210 D 783 Description: The device configuration failed. B88
783-220 D 783 Description: The Release command failed.
783-230 D 783 Description: The Request Sense command failed.
783-240 D 783 Description: The Openx command failed.
783-300 D 783 Description: The device configuration failed.software
783-310 D B88 Description: SCSI adapter configuration failed.783 software
783-320 G 783 Description: Error log analysis indicates a failure. media
783-411 D 783 Description: A reservation conflict
to occurred.
783-423 B88 software
783-511 D 783 Description: The drive returned bad or
to non-extended sense data.
783-523 B88
783-611 D 783 Description: An adapter or bus I/O error
to occurred.
783-623 B88 software
783-711 D 783 Description: A device timeout error
to occurred.
783-723 B88 software
784-102 D 784 Description: An unrecoverable media error.
784-104 D 784 Description: The motor failed to restart.
784-105 D 784 Description: The drive did not become ready.
784-106 D 784 Description: The electronics card test failed.
784-108 D 784 Description: The bus test failed.
784-110 D 784 Description: The media format is corrupted.
784-112 D 784 Description: The diagnostic test failed.
784-114 D 784 Description: An unrecoverable hardware error.
784-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
784-117 D 784 Description: A write protect error occurred.
784-118 D 784 Description: A SCSI command time-out. B88
784-120 D 784 Description: A SCSI busy or command error.
784-122 D 784 Description: A SCSI reservation conflict error.
784-124 D 784 Description: A SCSI check condition error.
784-126 D 784 Description: A software error was caused
by a hardware failure. B88
784-128 G 784 Description: The error log analysis
indicates a hardware failure.
784-129 G D50 Description: Error log analysis indicates
a SCSI bus problem. 784 B88 software
784-130 G 784 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
784-132 D 784 Description: A disk drive hardware error occurred.
784-134 D B88 Description: The adapter failed to configure.software
784-135 D 784 Description: The device failed to configure.software
784-136 D 784 Description: The certify operation failed.
784-137 D 784 Description: Unit attention condition has
occurred on the Send Diagnostic command.
785-111 D 785 Could not do the test because the device
driver detected a hardware error.
785-114 D 785 The register verification test failed.
785-121 D 785 Could not do the test because the device
driver detected a hardware error.
785-122 D 785 The data wrap communication test failed.
785-123 D 785 The modem control line test failed.
785-124 D 785 The memory test failed.
785-151 D 785 Could not do the test because the device
driver detected a hardware error.
785-152 D 785 The data wrap communication test failed.
785-153 D 785 The modem control line test failed.
785-171 D 259 Could not do the test because the device
driver detected a hardware error.
785-172 D 259 The data wrap communication test failed.
785-173 D 259 The modem control line test failed.
785-181 D 261 Could not do the test because the device
driver detected a hardware error.
785-182 D 261 The data wrap communication test failed.
785-183 D 261 The modem control line test failed.
785-251 D 785 Could not perform because the device
driver detected a hardware error.
785-252 D 785 The data wrap communication test failed.
785-253 D 785 The modem control line test failed.
785-271 D 785 Could not perform because the device
driver detected a hardware error.
785-272 D 785 The data wrap communication test failed.
785-273 D 785 The modem control line test failed.
785-281 D 785 Could not perform because the device
driver detected a hardware error.
785-282 D 785 The data wrap communication test failed.
785-283 D 785 The modem control line test failed.
785-481 D D57 Could not do the test because the device
driver detected a hardware error.
785-482 D D57 The data wrap communication test failed.
785-483 D D57 The modem control line test failed.
785-901 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
785-921 D 785 Description: The adapter failed to configure software
785-922 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
785-925 D 785 Description: The adapter failed to configure software
785-926 D software Description: An unexpected error occurred
that can be attributed to software or
to 785 hardware.
785-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 785; otherwise, suspect a software
problem.
786-200 D 786 Description: Initiation failed D96
Note: You must determine which of the first
two FFCs is installed in the system unit.
786-210 D 786 Description: The adapter test failed
786-211 D D96 Description: The adapter test failed
786-220 D 786 Description: The display test failed Cable Monitor
786-221 D D96 Description: The display test failed Cable Monitor
786-710 D 786 Description: The ELA indicates HW failure
786-711 D D96 The ELA indicates HW failure
787-100 D 787 GXT500P Graphics Adapter
787-101 D 787 Description: GXT500P Graphics Adapter
787-1AA D 787 Description: GXT500P Graphics Adapter RGB Cable Display
787-1xx D 787 Description: GXT500P Graphics Adapter
787-200 D D95 Description: GXT550P Graphics Adapter
787-201 D D95 Description: GXT550P Graphics Adapter
787-2AA D D95 Description: GXT550P Graphics AdapterRGB Cable Display
787-2xx D D95 Description: GXT550P Graphics Adapter
788-001 D 788 Description: Adapter Error
788-002 D software Description: System Error
788-003 D software Description: System Error
788-004 D 788 Description: System Error software
789-101 D 789 Description: Failed to release the device.
789-102 D 789 Description: Failed to reserve the device.
789-103 D 789 Description: The device motor failed to start.
789-104 D 789 Description: Failed to make the device ready.
789-105 D 789 Description: Failed to get the inquiry data.
789-106 D 789 Description: The Prevent Media Removal command failed.
789-107 D 789 Description: The Allow Media Removal command failed.
789-200 D 789 Description: The optical disk failed to load.
Optical Disk Action: Change the media.
Run diagnostics
on the changed media in System Verification
mode. If the error reoccurs use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-201 D 789 Description: Failed to unload the optical
disk. Optical Disk Action: Change the media.
Run diagnostics
on the changed media in System Verification
mode. If the errors reoccur use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-202 D 789 Description: The diagnostic test failed.
Action: Change the media. Run diagnostics
Optical Disk on the changed media in System Verification
mode. If errors do not reoccur, replace the
media; otherwise, run the drive cleaning
procedures if applicable and rerun the
diagnostics. If errors reoccur, or the
drive does not support the cleaning
procedures use Chapter 12. "MAP 0210:
General Problem Resolution".
789-204 D 789 Description: The device failed to configure.
789-205 D 789 Description: The Test Unit Ready command failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the error reoccurs, use Chapter
12. "MAP 0210: General Problem Resolution";
otherwise, replace the media.
789-206 D 789 Description: The random write, read and
compare test failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-207 D 789 Description: A hardware error occurred.
Action: Change the media. Run diagnostics
Optical Disk on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-208 D 789 Description: The Mode Sense command failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-209 D 789 Description: The Mode Select command failed.
Optical Disk Action: Change the media. Run diagnostics
on the changed media in System Verification
mode. If the errors do not reoccur, replace
the media; otherwise, run the drive
cleaning procedures if applicable, and
rerun diagnostics. If the errors reoccur,
or the drive does not support cleaning
procedures, use Chapter 12. "MAP 0210:
General Problem Resolution".
789-300 D 789 Description: A SCSI reservation conflict has occurred.software
789-400 D 789 Description: A SCSI command time out has occurred.Cables software
789-401 D Optical Disk Description: An unknown error has occurred.
789-402 D Optical Disk Description: Unit attention condition has occurred.software
789-600 G Optical Disk Description: ELA indicates that the spare
sectors on the disk are exhausted.
Action: Backup the media and replace it.
Note: Use the time when the error occurred
and the "Spare Sector Availability" service
aid to identify the disk that has the error.
789-700 G 789 Description: The ELA indicates an equipment error.
Optical Disk Action: Run diagnostics in System
Verification mode to isolate the problem.
If errors are reported, use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, the error is due to faulty
media. Backup the media and then replace it.
Note: Use the time when the error occurred
to identify the faulty media.
789-701 G Optical Disk Description: ELA indicates an
irrecoverable data error.
789 Action: Run diagnostics in System
Verification mode to isolate the problem.
If errors are reported, use Chapter 12.
"MAP 0210: General Problem Resolution";
otherwise, the error is due to faulty
media. Backup the media and then replace it.
Note: Use the time when the error occurred
to identify the faulty media.
789-702 G 789 Description: ELA indicates that the
adapter detected an error.
B88 Action: Use the 7209 Installation and
Service Guide. If the unit checks out to be
Cables good, use Chapter 12. "MAP 0210: General
Problem Resolution".
790-101 D 790 Description: Configuration Register Test failure
790-102 D 790 Description: I/O test failure
790-103 D 790 Description: Adapter initialization test failure
790-104 D 790 Description: Internal wrap test failure
790-105 D 790 Description: Internal wrap test failure
790-106 D 790 Description: External wrap (10Mbps) test failure
790-107 D 790 Description: Internal wrap test failure
790-108 D 790 Description: External wrap (100Mbps) test failure
790-109 D 790 Description: External wrap (10Mbps) test failure
790-121 D 790 Description: Configuration register test failure
790-122 D 790 Description: I/O register test failure
790-124 D 790 Description: Internal loopback test failure
790-125 D 790 Description: Internal loopback test failure
790-126 D 790 Description: External loopback test failure
790-150 D B08 Description: 10Base-T transceiver test failure
790-151 D B09 Description: 10Base-2 transceiver test failure
790-223 D 790 Description: Device configuration failure software
790-224 D B08 Description: 10 Base-T transceiver test failure
790-225 D B09 Description: 10 Base-2 transceiver test failure 790
790-250 D B08 Description: 10 Base-T transceiver test failure
790-251 D B09 Description: 10 Base-2 transceiver test failure
790-701 G 790 Description: Error Log Analysis indicates
that the adapter is not responding to
initialization commands.
790-702 G 790 Description: Error Log Analysis indicates
that the device driver has detected a PIO
error which it was unable to correct.
790-703 G 790 Description: Error Log Analysis indicates
that the adapter has been shutdown due to
an unrecoverable error.
790-704 G 790 Description: Error Log Analysis indicates
a problem with EEPROM on the adapter.
790-720 G 790 Description: Error log analysis indicates
a hardware problem software
791-098 J 791 Description: The disk drive indicates an error. B88
791-099 J 791 Description: The disk drive not found.
791-102 D 791 Description: An unrecoverable media error occurred.
791-104 D 791 Description: The motor failed to restart.
791-105 D 791 Description: The drive did not become ready.
791-106 D 791 Description: The electronics card test failed.
791-108 D 791 Description: The bus test failed.
791-110 D 791 Description: The media format is corrupted.
791-112 D 791 Description: The diagnostic test failed.
791-114 D 791 Description: An unrecoverable hardware error.
791-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
791-117 D 791 Description: A write protect error occurred.
791-118 D 791 Description: A SCSI command time-out occurred.
791-120 D 791 Description: A SCSI busy or command error.
791-122 D 791 Description: A SCSI reservation conflict error.
791-124 D 791 Description: A SCSI check condition error occurred.
791-126 D 791 Description: A software error was caused
by a hardware failure.
791-128 G 791 Description: The error log analysis
indicates a hardware failure.
791-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
791-130 G 791 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
791-132 D 791 Description: A disk drive hardware error occurred.
791-134 D B88 Description: The adapter failed to configure. software
791-135 D 791 Description: The device failed to configure. software
791-136 D 791 Description: The certify operation failed.
791-137 D 791 Description: Unit attention condition has
occurred on the Send Diagnostic command.
792-098 J 792 Description: The disk drive indicates an error.
792-099 J 792 Description: The disk drive not found.
792-102 D 792 Description: An unrecoverable media error occurred.
792-104 D 792 Description: The motor failed to restart.
792-105 D 792 Description: The drive did not become ready.
792-106 D 792 Description: The electronics card test failed.
792-108 D 792 Description: The bus test failed.
792-110 D 792 Description: The media format is corrupted.
792-112 D 792 Description: The diagnostic test failed.
792-114 D 792 Description: An unrecoverable hardware error.
792-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
792-117 D 792 Description: A write protect error occurred.
792-118 D 792 Description: A SCSI command time-out occurred.
792-120 D 792 Description: A SCSI busy or command error.
792-122 D 792 Description: A SCSI reservation conflict error.
792-124 D 792 Description: A SCSI check condition error occurred.
792-126 D 792 Description: A software error was caused
by a hardware failure.
792-128 G 792 Description: The error log analysis
indicates a hardware failure.
792-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
792-130 G 792 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
792-132 D 792 Description: A disk drive hardware error occurred.
792-134 D B88 Description: The adapter failed to configure.software
792-135 D 792 Description: The device failed to configure. software
792-136 D 792 Description: The certify operation failed.
792-137 D 792 Description: Unit attention condition has
occurred on the Send Diagnostic command.
793-098 J 793 Description: The disk drive indicates an error.
793-099 J 793 Description: The disk drive not found.
793-102 D 793 Description: An unrecoverable media error occurred.
793-104 D 793 Description: The motor failed to restart.
793-105 D 793 Description: The drive did not become ready.
793-106 D 793 Description: The electronics card test failed.
793-108 D 793 Description: The bus test failed.
793-110 D 793 Description: The media format is corrupted.
793-112 D 793 Description: The diagnostic test failed.
793-114 D 793 Description: An unrecoverable hardware error.
793-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
793-117 D 793 Description: A write protect error occurred.
793-118 D 793 Description: A SCSI command time-out occurred.
793-120 D 793 Description: A SCSI busy or command error.
793-122 D 793 Description: A SCSI reservation conflict error.
793-124 D 793 Description: A SCSI check condition error occurred.
793-126 D 793 Description: A software error was caused by hardware failure.
793-128 G 793 Description: The error log analysis
indicates a hardware failure.
793-129 G D50 Description: Error log analysis indicates
a SCSI bus problem.
793-130 G 793 Description: Error log analysis indicates
a problem reported by the disk drive's self
monitoring function.
793-132 D 793 Description: A disk drive hardware error occurred.
793-134 D B88 Description: The adapter failed to configure.software
793-135 D 793 Description: The device failed to configure.software
793-136 D 793 Description: The certify operation failed.
793-137 D 793 Description: Unit attention condition has
occurred on the Send Diagnostic command.
795-201 D 795 Description: Config register test failure
795-202 D 795 Description: PROM check test failure
795-203 D 795 Description: Timer and IRQ test failure
795-204 D 795 Description: Adapter RAM check failure
795-205 D 795 Description: ASIC test failure
795-206 D 795 Description: High memory (ISA) test failure
795-207 D 795 Description: RAM check via DMA test failure
795-208 D 795 Description: FORMAC register test failure
795-209 D 795 Description: PLC1 test failure
795-210 D 795 Description: PLC2 test failure
795-211 D 795 Description: FORMAC Ring_Op test failure
795-212 D 795 Description: Send long frame test failure
795-213 D 795 Description: Restricted Token Monitor test failure
795-214 D 795 Description: Receive queue handling test failure
795-215 D 795 Description: FORMAC loopback test failure
795-216 D 795 Description: FORMAC loopback with master
access test failure
795-217 D 795 Description: DMA measurement test failure
795-218 D 795 Description: Special test failure
795-219 D 795 Description: Bypass test failure
795-301 D 795 Description: PLC1 FDDI external wrap failure
795-302 D 795 Description: PLC2 FDDI external wrap failure
795-303 D 795 Description: Send long frame FDDI external wrap failure
795-304 D 795 Description: FORMAC loopback external wrap failure
795-700 D 795 Description: Error log analysis indicates
hardware failure
799-101 D 2C3 Description: External wrap test failed on port 0
799-102 D 2C3 Description: External wrap test failed on port 1
799-201 D 799 Description: Internal adapter test failed
799-202 D 799 Description: External wrap test failed on port 0
799-203 D 799 Description: External wrap test failed on port 1
799-204 D 2C3 Description: External wrap test failed on port 0
799-205 D 2C3 Description: External wrap test failed on port 1
799-206 D 2C3 Description: External wrap test failed on port 0
799-207 D 2C3 Description: External wrap test failed on port 1
799-301 D 799 Description: Internal adapter test failed
799-302 D 799 Description: External wrap test failed on port 0
799-303 D 799 Description: External wrap test failed on port 1
799-304 D 2C3 Description: External wrap test failed on port 0
799-305 D 2C3 Description: External wrap test failed on port 1
799-700 D 799 Description: Error log analysis indicates
a hardware problem software
7C1-101 D 7C1 Description: Audio Subsystem failed software
7C1-102 D 7C1 Description: CS4232 Failed
7C1-103 D 7C1 Description: Clock control failed
7C1-107 D 7C1 Description: SoundBlaster interface failed
7C1-108 D 7C1 Description: Loop back failed
7C1-109 D 7C1 Description: CODEC ID invalid
7C1-117 D D97 Description: Internal speaker failed
801-101 C Description: The diagnostics did not
detect an installed resource.
to Action: Ensure supplemental diskettes have
been read, if applicable, then use Chapter
801-102 18. "MAP 0290: Missing Resource Problem
Resolution".
802-787 C 787 Description: The diagnostics did not
detect an installed resource.
802-78C C Description: A system bus problem exists.
Action: Use Chapter 11. "MAP 0080 System
Bus Problem Isolation".
802-xxx C xxx Description: The diagnostics did not
detect an installed resource.
Note: To obtain the FFC substitute the last
three digits of the SRN for xxx. (The
substituted xxx is the FFC.)
803-xxx D Use the xxx Description: An error occurred while
running the diagnostics.(See note number
Action: Run nondisk-based diagnostics where
possible. If this SRN was generated from in Action
the nondisk-based diagnostic package, or it
is not possible to use the nondisk-based column.)
package, go to Chapter 15. "MAP 0250:
Unexpected System Halts During
Diagnostics". If the problem occurs only
from disk-or server-based diagnostics,
suspect a software problem.
Notes:
1. If your 803-xxx SRN is listed in
this section, use the procedure
for that SRN instead of this one.
2. If the xxx FFC is not listed in
the FFC list, Use MAP 1540 to
determine the failing FRU.
804-111 D 804 Description: Unable to reserve device.
804-112 D 804 Description: Unable to do configuration.
804-113 D 804 Description: Unable to open the device driver.
804-121 D 804 Description: The CD-ROM drive indicates an error.
804-122 D 804 Description: The CD-ROM drive indicates an error.
804-123 D 804 Description: The CD-ROM drive indicates an error.
804-125 D 804 Description: The CD-ROM drive indicates an error.
804-126 D 804 Description: The CD-ROM drive indicates an error.
804-127 D 804 Description: The CD-ROM drive indicates an error.
804-128 D 804 Description: The CD-ROM drive indicates an error.
804-129 D 804 Description: The CD-ROM drive indicates an error.
804-150 D Media Description: A media error was detected.
804-151 D 804 Description: A command timeout was detected.
804-152 D 804 Description: A command reservation conflict was detected.
804-162 D 804 Description: The CD-ROM drive indicates an error.
804-171 D 804 Description: Unable to reserve device.
804-172 D 804 Description: Unable to do configuration.
804-173 D 804 Description: Unable to open device driver.
804-175 D 804 Description: The CD-ROM drive indicates an error.
804-198 D 804 Description: Undefined error detected.
804-199 D 804 Description: Undefined error detected.
804-211 D 804 Description: The LED test failed.
804-281 D 804 Description: No tone during audio test.
804-301 G 804 Description: Errors found during ELA.
804-302 G 804 Description: Errors found during ELA.
804-xxx H Use the Description: An unexpected halt occurred
while running the diagnostics.
xxx Note: If your 804-xxx SRN is listed in this number
section, use the procedure for that SRN
instead of this one.
Action: Use Chapter 15. "MAP 0250:
Unexpected System Halts During
Diagnostics".
805-110 G D67 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-111 G D83 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-120 G D68 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-121 G D84 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-130 G D69 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-131 G D85 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-140 G D70 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-141 G D86 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-150 G E11 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-151 G E14 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-210 G D71 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-211 G D87 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-220 G D72 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-221 G D88 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-230 G D73 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-231 G D89 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-240 G D74 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-241 G D90 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-250 G E12 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-251 G E15 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-310 G D75 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-311 G D91 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-320 G D76 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-321 G D92 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-331 G D93 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-340 G D78 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-341 G D94 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-350 G E13 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-351 G E16 Description: Error log analysis indicates
a machine check due to uncorrectable memory error.
Action: Use Chapter 14. "MAP 0240: Memory
Problem Resolution".
805-600 G Description: Error log analysis indicates
a machine check due to uncorrectable memory
error or unsupported memory.
Action: Examine the memory modules and
determine if they are supported types. If
the modules are supported, then replace the
appropriate memory module(s). Use Chapter
14. "MAP 0240: Memory Problem Resolution".
805-601 G 210 Description: Error log analysis indicates
a machine check due to CPU internal cache error.
805-602 G 214 Description: Error log analysis indicates
a machine check due to CPU address/data bus
D01 parity error.
805-603 G 210 Description: Error log analysis indicates
a machine check due to CPU bus transfer error.
805-604 G 210 Description: Error log analysis indicates
a machine check due to CPU address/data bus parity error.
805-605 G 210 Description: Error log analysis indicates
a machine check due to CPU bus transfererror.
805-606 G 214 Description: Error log analysis indicates
a machine check due to memory controller internal error.
805-607 G 210 Description: Error log analysis indicates
a machine check due to memory address error.
805-608 G 214 Description: Error log analysis indicates
a machine check due to a Flash ROM error.
805-609 G D01 Description: Error log analysis indicates
a machine check due to a L2 parity error.
805-610 G Description: Error log analysis indicates
a machine check due to ISA device error,
but the device could not be identified.
Action: Run diagnostics on the ISA devices.
805-611 G Description: Error log analysis indicates
a machine check due to EISA/ISA bus time
out error, but the device could not be identified.
Action: Run diagnostics on the ISA devices.
If multiple devices fail, use FFC 295.
805-612 G 214 Description: Error log analysis indicates
a machine check due to an Illegal L2 copyback operation.
805-616 G software Description: Error log analysis indicates
a machine check due to software.
805-617 G Description: Error log analysis indicates
a machine check of unknown origin.
Action: If the problem is persistent, use
MAP 1540.
805-618 G Description: Error log analysis indicates
multiple instances of machine check of
unknown origin.
Action: If the problem is persistent, use
MAP 1540.
805-619 G 221 Description: Error log analysis indicates
a machine check due to an unidentified
source on the I/O subsystem. Action: Use
Chapter 12. "MAP 0210: General Problem
Resolution".
805-621 G 292 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-622 G 293 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-623 G 294 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-624 G 295 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-625 G 868 Description: Error log analysis indicates
a machine check due to Integrated PCI
device does not respond.
805-631 G 292 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-632 G 293 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-633 G 294 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-634 G 295 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-635 G 868 Description: Error log analysis indicates
a machine check due to Internal error from
PCI device.
805-640 G 2E8 Description: Error log analysis indicates
a machine check due to a system bus error.
805-641 G 2E8 Description: Error log analysis indicates
a machine check due to a processor bus error.
805-642 G 2E8 Description: Error log analysis indicates
a machine check due to a directory parity error.
805-643 G 2E8 Description: Error log analysis indicates
a machine check due to a cache paradox.
805-644 G 2E8 Description: Error log analysis indicates
a machine check due to an internal error.
805-645 G 2E8 Description: Error log analysis indicates
a machine check due to a detected L2 hit signal.
805-646 G 2E8 Description: Error log analysis indicates
a machine check due to an address/data bus parity error.
805-649 G software Description: Error log analysis indicates
a machine check due to a disabled I/O address space.
Action: Run Standalone Diagnostics on all
devices. Use any SRN reported. If no other
SRN is reported, suspect a software problem.
805-801 G 166 Description: Slow fan or defective thermal sensor.
221 Action: 1) Check spacing around system
enclosure, 2) check for obstructions to
cooling air flow, 3) check that all fans
can rotate freely, and spin with power
applied. If reasons 1, 2 and 3 can be ruled
out, then replace the listed FRUs.
805-802 G 152 Description: Over/Under voltage condition.
210 Action: Check AC line voltage per the Power
MAP in your service guide. If the AC line
voltage is correct replace the listed FRUs.
805-803 G 2E1 Description: System shutdown due to
non-critical over temperature condition.
210 Action: 1) check for obstructions to
cooling air flow, 2) check for accumulated
dust on the CPU and planar. If reasons 1
and 2 can be ruled out, then replace the listed FRUs.
805-804 G 166 Description: System shutdown due to
critical over temperature condition.
2E1 Action: Check to ensure fans are connected.
If fans are connected, then replace the listed FRUs.
805-805 G 152 Description: System shutdown due to loss of AC power.
Action: Check the voltage range switch, if
present, on the power supply and ensure
that it is set to match the AC input
voltage. If the range switch is set
correctly or is not present refer to "MAP
1520: Power" in the Service Guide for your system.
805-807 G 166 Description: System shutdown due to an inoperative fan.
Action: Check to ensure fans are connected.
If fans are connected replace the listed FRU.
805-811 D 166 Description: Slow fan or defective thermal sensor.
Action:
1. Check spacing around system enclosure
2. Check for obstructions to cooling air flow
3. Check that all fans rotate freely, and
spin when power is applied.
If reasons 1, 2, and 3 can be ruled out,
then replace the listed FRUs.
805-812 D 152 Description: Over/Under voltage condition.
210 Action: Check the AC line voltage per the
Power MAP in your service guide. If the AC
line voltage is correct replace the listed FRUs.
805-813 D 2E1 Description: System shutdown due to
non-critical over temperature condition.
210 Action:
1. Check for obstructions to cooling air flow.
2. Check for accumulated dust on the CPU and planar.
If reasons 1 and 2 can be ruled out, then
replace the listed FRUs.
806-001 D 806 GXT800P Graphics Adapter
thru
806-017
806-018 D 806 GXT800P Graphics Adapter Monitor/Display Cable
806-100 D 806 Description: GXT800P Graphics Adapter
806-505 D 806 Description: GXT800P Graphics Adapter
GXT800P Base Memory in slot 0, 1, 2, 3, or 4
806-515 D 806 Description: GXT800P Graphics Adapter
GXT800P Base and Texture Memory in slot 0,
1, 2, 3, or 4
806-619 G 221 Description: Error log analysis indicates
a machine check due to an unidentified
source on the I/O subsystem.
806-700 D 298 GXT800P Base Memory in slot 0
806-701 D 298 GXT800P Base Memory in slot 1
806-702 D 298 GXT800P Base Memory in slot 2
806-703 D 298 GXT800P Base Memory in slot 3
806-704 D 298 GXT800P Base Memory in slot 4
806-710 D 297 GXT800P Base and Texture Memory in slot 0
806-711 D 297 GXT800P Base and Texture Memory in slot 1
806-712 D 297 GXT800P Base and Texture Memory in slot 2
806-713 D 297 GXT800P Base and Texture Memory in slot 3
806-714 D 297 GXT800P Base and Texture Memory in slot 4
806-e00 D 298 GXT800P Base Memory in slot 0
806-e01 D 298 GXT800P Base Memory in slot 1
806-e02 D 298 GXT800P Base Memory in slot 2
806-e03 D 298 GXT800P Base Memory in slot 3
806-e04 D 298 GXT800P Base Memory in slot 4
806-e10 D 297 GXT800P Base and Texture Memory in slot 0
806-e11 D 297 GXT800P Base and Texture Memory in slot 1
806-e12 D 297 GXT800P Base and Texture Memory in slot 2
806-e13 D 297 GXT800P Base and Texture Memory in slot 3
806-e14 D 297 GXT800P Base and Texture Memory in slot 4
807-201 D 199 Description: Device configuration error
807-202 D 199 Description: Enclosure failed to open
807-203 D 199 Description: Enclosure failed to return inquiry data
807-204 D 152 Description: Redundant power supply or fan failure
807-205 D 152 Description: Redundant power supply or fan failure
814-112 D 814 Description: The NVRAM test failed.
814-113 D 221 Description: The VPD test failed.
814-114 D 814 Description: I/O Card NVRAM test failed.
815-100 D 815 Description: The floating-point processor test failed.
815-101 D 815 Description: Floating point processor failed.
815-102 D 815 Description: Floating point processor failed.
815-200 D 815 Description: Floating point processor failed.
816-140 D 165 Description: The four-digit display test failed.
817-123 D 817 Description: The I/O planar time-of-day clock test failed.
817-124 D 817 Description: Time of day RAM test failed.
817-210 D 817 Description: The time-of-day clock is at POR.
817-211 D 817 Description: Time of day POR test failed.
817-212 D 151 Description: The battery is low.
817-213 D 817 Description: The real-time clock is not running.
817-215 D 817 Description: Time of day clock not running test failed.
817-217 D 817 Description: Time of day clock not running.
821-111 D 821 Description: Unexpected results from the test.
821-220 D B10 Description: Keyboard adapter fuse failed.
821-221 D 821 Description: The keyboard adapter test failed.
821-230 D 221 Description: Software error caused by hardware failure.
821-240 G 821 Description: The error log analysis
indicates hardware failure.
821-241 G 221 Description: The error log analysis
indicates hardware failure.
821-242 G 921 Description: The error log analysis
indicates hardware failure.
821-243 G 922 Description: The error log analysis
indicates hardware failure.
821-244 G 923 Description: The error log analysis
indicates hardware failure.
821-310 D 821 Description: Standard Keyboard Adapter
to failed.
821-331
821-332 D 821 Description: Cannot open device.software
821-333 D 821 Description: Keyboard/tablet adapter failed.
to
821-334
821-921 D 921 Description: The keyboard adapter control logic failed.
821-922 D 922 Description: The keyboard adapter control logic failed.
821-923 D 923 Description: The keyboard adapter control logic failed.
823-111 D 823 Description: Standard Mouse adapter failed.
to 925
823-112
823-113 D B10 Description: The mouse adapter fuse failed.
823-121 D 823 Description: Built-In mouse adapter problems.
to
823-122
823-130 D 221 Description: Software error caused by
hardware failure.
823-131 D 823 Description: Unable to put mouse adapter
into nonblock mode.
823-132 D 823 Description: Built-In mouse adapter problem.
to
823-133
823-134 D 823 Description: Cannot open device. software
823-140 G 823 Description: The error log analysis
indicates hardware failure.
823-141 D 823 Description: Unable to place mouse adapter
in block mode.
823-142 D 823 Description: Unable to place mouse adapter
in block mode.
823-220 D B10 Description: The mouse adapter fuse failed.
824-220 D 824 Description: The tablet adapter fuse failed.
824-331 D 824 Description: An unexpected error occurred.
824-332 D 824 Description: The enable/disable device test failed.
227 Note:Ensure that the wrap plug was not
attached when the test was run. If the wrap
plug was attached, remove it, and rerun the test.
824-333 D 824 Description: The internal wrap test failed.
824-334 D B10 Description: The tablet adapter fuse failed.824
824-441 D 824 Description: An unexpected error occurred.
824-442 D 824 Description: The wrap test failed.
824-450 D 227 Description: Software error caused by hardware failure.
824-461 G 227 Description: The error log analysis
indicates a hardware failure.
824-511 D 824 Description: An unexpected error occurred.
824-512 D 824 Description: Tablet adapter reset test failed.
824-522 D B10 Description: Adapter fuse failure.
824-523 D 824 Description: Device cannot be configured.
824-524 D 824 Description: Cannot open device. software
826-111 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
826-112 D 221 Description: Unable to determine the type
of adapter from the VPD.
826-113 D 826 Description: The VPD verification test failed.
826-114 D 826 Description: The register verification test failed.
826-121 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
826-122 D 221 Description: The data-wrap communications test failed.
826-123 D 221 Description: The modem control line test failed.
826-131 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
826-132 D 221 Description: The data wrap communications test failed.
826-133 D 221 Description: The modem control line test failed.
826-161 D 252 Description: Cannot run the test because
the device driver detected a hardware error.
826-162 D 252 Description: The data wrap communications test failed.
826-163 D 252 Description: The modem control line test failed.
826-171 D 259 Description: Cannot run the test because
the device driver detected a hardware error.
826-172 D 259 Description: The data wrap communications
test failed.
826-173 D 259 Description: The modem control line test failed.
826-181 D 261 Description: Cannot run the test because
the device driver detected a hardware error.
826-182 D 261 Description: The data wrap communications test failed.
826-183 D 261 Description: The modem control line test failed.
826-271 D 826 Description: Cannot run the test because
the device driver detected a hardware error.
826-272 D 826 Description: The data wrap communications test failed.
826-273 D 826 Description: The modem control line test failed.
826-281 D 826 Description: Cannot run the test because
the device driver detected a hardware error.
826-282 D 826 Description: The data wrap communications test failed.
826-283 D 826 Description: The modem control line test failed.
826-321 D 826 Description: Cannot run the test because
the device driver detected a hardware error.
826-322 D 826 Description: The data wrap communications test failed.
826-323 D 826 Description: The modem control line test failed.
826-331 D 826 Description: Cannot run the test because
the device driver detected a hardware error.
826-332 D 826 Description: The data wrap communications test failed.
826-333 D 826 Description: The modem control line test failed.
826-371 D 826 Description: Cannot run the test because
the device driver detected a hardware error.
826-372 D 826 Description: The data wrap communications test failed.
826-373 D 826 Description: The modem control line test failed.
826-381 D 826 Description: Could not do the test because
the device driver detected a hardware error.
826-382 D 826 Description: The data wrap communication test failed.
826-383 D 826 Description: The modem control line test failed.
826-481 D D56 Description: Could not do the test because
the device driver detected a hardware error.
826-482 D D56 Description: The data wrap communication test failed.
826-483 D D56 Description: The modem control line test failed.
826-581 D 826 Description: Could not do the test because
the device driver detected a hardware error.
826-582 D 826 Description: The data wrap communication test failed.
826-583 D 826 Description: The modem control line test failed.
826-901 D software Description: An unexpected error occurred
to that can be attributed to software or hardware.
826-920 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software problem.
826-921 D 826 Description: The adapter failed to configure software
826-922 D software Description: An unexpected error occurred
to that can be attributed to software or hardware.
826-924 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software problem.
826-925 D 826 Description: The adapter failed to configure software
826-926 D software Description: An unexpected error occurred
to that can be attributed to software or hardware.
826-943 Action: Run diagnostics from a source other
than from the disk or a network. If the
same error occurs or if the original SRN
was not obtained from disk or a network
based diagnostics, use Chapter 12. "MAP
0210: General Problem Resolution" with a
FFC of 826; otherwise, suspect a software problem.
827-112 D 221 Description: The parallel port data
register write/read test failed.
827-121 D 827 Description: Cannot run the test because
the device driver detected a hardware error.
827-122 D 827 Description: The parallel port data
register write/read test failed.
827-123 D 827 Description: The parallel port control
register write/read test failed.
827-124 D 827 Description: The parallel port data
register read test failed.
827-125 D 827 Description: The parallel port control
register read test failed.
827-126 D 827 Description: The parallel port control
register read test failed.
827-131 D 827 Description: Cannot run the test because
the device driver detected a hardware error.
827-132 D 827 Description: The control port register
direction bit (write) test with BIDI
enabled failed.
827-133 D 827 Description: The control port register
direction bit (read) test with BIDI enabled failed.
827-141 D 827 Description: Cannot run the test because
the device driver detected a hardware error.
827-142 D 827 Description: The parallel port control
register write/read test with BIDI
enabled failed.
827-151 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
827-152 D 827 Description: The parallel port status
register read test failed.
827-161 D 827 Description: Cannot run the test because
the device driver detected a hardware error.
827-162 D 221 Description: The parallel port interrupt
test failed.
827-163 D 221 Description: The parallel port interrupt
test failed.
827-201 D 827 Description: The extend control register
of the parallel port failed a read/write test.
827-202 D 827 Description: Input/output to the FIFO
(without interrupts) failed.
827-203 D 827 Description: Input/output to the FIFO
(with interrupts) failed.
827-204 D 827 Description: Direct memory access to the
FIFO failed.
828-501 D 828 Description: The diskette adapter test failed.
82C-102 D 82C Description: Adapter test failed.
82C-104 D 82C Description: Display test failed.
830-111 D 830 Description: Could not do the test
because the device driver detected a hardware error.
830-114 D 830 Description: The register verification test failed.
830-121 D 830 Description: Could not do the test
because the device driver detected a
227 hardware problem.
830-122 D 830 Description: The data wrap communication test failed.
830-123 D 830 Description: The modem control line test failed.
830-124 D 830 Description: The memory test failed.
830-151 D B54 Description: Could not do the test
because the device driver detected a
830 hardware error.
830-152 D B54 Description: The data wrap communication test failed.
830-153 D D54 Description: The modem control line test failed.
830-171 D 259 Description: Could not run the test
because the device driver detected a hardware error.
830-172 D 259 The data wrap communication test failed.
830-173 D 259 Description: The modem control line test failed.
830-181 D 261 Description: Could not do the test
because the device driver detected a
hardware error.
830-182 D 261 Description: The data wrap communication
test failed.
830-183 D 261 Description: Interposer Wrap test failed.
830-251 D 830 Description: Could not perform because
the device driver detected a hardware error.
830-252 D 830 Description: The data wrap communication test failed.
830-253 D 830 Description: The modem control line test failed.
830-271 D 830 Description: Could not perform because
the device driver detected a hardware error.
830-272 D 830 Description: The data wrap communication test failed.
830-273 D 830 Description: The modem control line test failed
830-281 D 830 Could not perform the test because the
device driver detected a hardware error.
830-282 D 830 Description: The data wrap communication test failed.
830-283 D 830 Description: The modem control line test failed.
830-481 D B54 Description: Could not do the test
because the device driver detected a
hardware error.
830-482 D B54 Description: The data wrap communication test failed.
830-483 D B54 Description: Async Cable Wrap Test failed.
830-901 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-9 20 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
830-921 D 830 Description: The adapter failed to
configure software
830-922 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
830-925 D 830 Description: The adapter failed to
configure software
830-926 D software Description: An unexpected error
occurred that can be attributed to
to 830 software or hardware.
830-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 830; otherwise,
suspect a software problem.
831-111 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
831-112 D 221 Description: Unable to determine the
type of adapter from the VPD.
831-113 D 831 Description: The VPD verification test failed.
831-114 D 831 Description: The register verification test failed.
831-121 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
831-122 D 221 Description: The data wrap
communications test failed.
831-123 D 221 Description: The modem control line test failed.
831-131 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
831-132 D 221 Description: The data wrap
communications test failed.
831-133 D 221 Description: The modem control line test failed.
831-161 D 252 Description: Cannot run the test because
the device driver detected a hardware error.
831-162 D 252 Description: The data wrap
communications test failed.
831-163 D 252 Description: The modem control line test failed.
831-164 D 221 Description: Cannot run the test because
the device driver detected a hardware error.
831-165 D 221 Description: The data wrap
communications test failed.
831-166 D 221 Description: The modem control line test failed.
831-171 D 259 Description: Cannot run the test because
the device driver detected a hardware error.
831-172 D 259 Description: The data wrap
communications test failed.
831-173 D 259 Description: The modem control line test failed.
831-181 D 261 Description: Cannot run the test because
the device driver detected a hardware error.
831-182 D 261 Description: The data wrap
communications test failed.
831-183 D 261 Description: The modem control line test failed.
831-271 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-272 D 831 Description: The data wrap communication test failed.
831-273 D 831 Description: The modem control line test failed.
831-281 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-282 D 831 Description: The data wrap communications test failed.
831-283 D 831 Description: The modem control line test failed.
831-321 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-322 D 831 Description: The data wrap
communications test failed.
831-323 D 831 Description: The modem control line test failed.
831-331 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-332 D 831 Description: The data wrap
communications test failed.
831-333 D 831 Description: The modem control line test failed.
831-371 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-372 D 831 Description: The data wrap
communications test failed.
831-373 D 831 Description: The modem control line test failed.
831-381 D 831 Description: Cannot run the test because
the device driver detected a hardware error.
831-382 D 831 Description: The data wrap
communications test failed.
831-383 D 831 Description: The modem control line test failed.
831-481 D D56 Description: Could not do the test
because the device driver detected a
hardware error.
831-482 D D56 Description: The data wrap communication test failed.
831-483 D D56 Description: The modem control line test failed.
831-581 D 831 Description: Could not do the test
because the device driver detected a
hardware error.
831-582 D 831 Description: The data wrap communication
test failed.
831-583 D 831 Description: The modem control line test failed.
831-901 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-920 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
831-921 D 831 Description: The adapter failed to configure software
831-922 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
831-925 D 831 Description: The adapter failed to configure software
831-926 D software Description: An unexpected error
occurred that can be attributed to
to 831 software or hardware.
831-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 831; otherwise,
suspect a software problem.
832-xxx G xxx I/O Device Internal Error
Note: xxx represents the last 3 digits of
the SRN.
833-xxx G xxx Description: PCI device address parity
error, PCI device data parity error, or
296 PCI device abort error. The diagnostics
screen indicates the actual error.
Note: xxx represents the last 3 digits of
the SRN.
836-101 D 836 Description: Cannot run the test
because the device driver detected a
hardware error.
836-111 D 836 Description: Cannot run test because
the device driver detected a hardware error.
836-112 D 836 Description: Unable to determine the
type of adapter from the VPD.
836-113 D 836 Description: The VPD verification test failed.
836-114 D 836 Description: The register verification test failed.
836-115 D 836 Description: The VPD verification test failed.
836-116 D B54 Description: The 128-port controller line test failed.
836-117 D 684 Description: Remote Async Node test failed.
836-118 D 837 Description: Remote async node test failed.
836-119 F 836 Description: Sync line termination test failed.
836-151 D 837 Description: Cannot run the test
because the device driver detected a hardware error.
836-152 D 837 Description: The data wrap communications test failed.
836-153 D 837 Description: The modem control line test failed.
836-154 D 684 Desciption: Cannot run the test because
the device driver detected a hardware error.
836-155 D 684 Description: The data wrap communications test failed.
836-161 D C22 Description: Cannot run the test
because the device driver detected a hardware error.
836-162 D C22 Description: The data wrap
communications test failed.
836-163 D C22 Description: The modem control line test failed.
836-164 D D06 Description: The data wrap
communication test failed.
836-171 D 259 Description: Cannot run the test
because the device driver detected a hardware error.
836-172 D 259 Description: The data wrap
communications test failed.
836-173 D 259 Description: The modem control line test failed.
836-174 D 263 Description: Cannot run the test because
the device driver detected a hardware
error while running the Printer/Terminal
cable wrap test.
836-175 D 263 Description: The data wrap
communications test failed while running
the Printer/Terminal cable wrap test.
836-181 D 261 Description: Cannot run the test
because the device driver detected a
hardware error.
836-182 D 261 Description: The data wrap
communications test failed.
836-183 D 261 Description: The modem control line test failed.
836-251 D 836 Description: Cannot run the test
because the device driver detected a
hardware error.
836-252 D 836 Description: The data wrap
communications test failed.
836-253 D 836 Description: The modem control line test failed.
836-254 D 836 Description: Cannot run the test because
the device driver detected a hardware
error while running the Remote Async Node
wrap test.
836-255 D 836 Description: The data wrap
communications test failed while running
the Remote Async Node wrap test.
836-271 D 836 Description: Cannot run the test
because the device driver detected a
hardware error.
836-272 D 836 Description: The data wrap
communications test failed.
836-273 D 836 Description: The modem control line test failed.
836-274 D 836 Description: Cannot run the test because
the device driver detected a hardware
error while running the Printer/Terminal
cable wrap test.
836-275 D 836 Description: The data wrap
communications test failed while running
the Printer/Terminal cable wrap test.
836-281 D 836 Description: Cannot run the test
because the device driver detected a
hardware error.
836-282 D 836 Description: The data wrap communication test failed.
836-283 D 836 Description: The modem control line test failed.
836-481 D D56 Description: Could not do the test
because the device driver detected a
hardware error.
836-482 D D56 Description: The data wrap communication test failed.
836-483 D D56 Description: The modem control line test failed.
836-901 D software Description: An unexpected error
to occurred that can be attributed to
836-920 836 software or hardware.
Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
836-921 D 836 Description: The adapter failed to configure software
836-922 D software Description: An unexpected error
to occurred that can be attributed to
836-924 836 software or hardware.
Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
836-925 D 836 Description: The adapter failed to configure software
836-926 D software Description: An unexpected error
to occurred that can be attributed to
836-943 software or hardware.
Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 836; otherwise,
suspect a software problem.
840-212 D 840 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-213 D 840 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
221 Problems Isolation Procedure".
840-214 D 840 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-215 D 840 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-216 D 840 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-217 D 840 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure"
840-218 D 840 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-219 D 840 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-220 D 840 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-221 D 840 Description: Miscompare during the
write/read of the configuration register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-222 D 840 Description: Error during the write/read
of the memory register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-223 D 840 Description: Miscompare during the
write/read of the memory I/O register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-224 D 840 Description: Error reading the PCI configuration register.
840-225 D 840 Description: Adapter POST failed.
840-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure"..
840-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-240 D 840 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-301 D 840 Description: Configuration open failed
for parent bus. D50 software
840-700 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.software
840-701 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
840-702 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.software
840-703 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
840-704 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
840-705 G 840 Description: Error log analysis
indicates a PCI SCSI adapter failure.software
840-800 G 746 Description: Error log analysis
indicates a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
840-802 G 840 Description: Error log analysis
indicates a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
844-XXX D 844 Description: A 7135 controller problem series is indicated.
Action: Use 7135 documentation.
845-XXX D 845 Description: A 7135 DASD drawer problem series
is indicated.
Action: Use 7135 documentation.
846-XXX D 846 Description: A 7135 DASD drawer problem series
is indicated.
Action: Use 7135 documentation.
868-110 D 221 Description: The adapter diagnostic
subcommand test failed.
868-130 D 279 Description: The adapter fuse test failed.
868-140 D 868 Description: The wrap test failed.
868-150 D 868 Description: The BCR registers write/read test failed.
868-160 D 868 Description: The POS registers write/read test failed.
868-170 D 868 Description: The internal/external reset test failed.
868-180 D 279 Description: The adapter command timed out. 868
Note: Check the fuse before replacing.
868-190 D 221 Description: A software error was caused
by a hardware failure.
868-191 G 868 Description: Analysis of the error log
indicates a problem with the hardware.
868-192 G 221 Description: Analysis of the error log
indicates a problem with the hardware.
868-193 G 279 Description: Analysis of the error log
indicates a problem with the hardware.
868-194 G 868 Description: Analysis of the error log
indicates a problem with the hardware.
868-200 D 868 Description: ROM CRC error.
868-201 D 868 Description: Adapter RAM error.
868-202 D 868 Description: The control logic failed.
868-203 D 868 Description: The control logic failed.
868-204 D 868 Description: The control logic failed.
868-205 D 868 Description: The control logic failed.
868-206 D 868 Description: Diagnostics completed with a previous error.
868-211 D 279 Description: The device failed to
configure. 868 software
868-212 D 221 Description: FIFO empty bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-213 D 221 Description: FIFO empty bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-214 D 221 Description: FIFO full bit set.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-215 D 221 Description: FIFO full bit clear.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-216 D 221 Description: FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-217 D 221 Description: SCSI FIFO data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-218 D 221 Description: SCSI FIFO underflow.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-219 D 221 Description: SCSI parity error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-220 D 221 Description: SCSI FIFO flags error.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-221 D 221 Description: Miscompare during the
write/read of the configuration register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-222 D 221 Description: Error during the write/read
of the memory register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-223 D 221 Description: Miscompare during the
write/read of the memory I/O register.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-224 D 221 Description: Error reading the PCI
configuration register.
Action: Use Chapter 12. "MAP 0210:
General Problem Resolution".
868-225 D 221 Description: POST failed.
868-230 D D50 Description: Arbitration test failed.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-231 D D50 Description: Function could not complete.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-232 D D50 Description: SCSI bus data miscompare.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-240 D 221 Description: No terminal power.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-301 D 868 Description: Configuration open failed
for parent bus. D50 software
868-700 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
868-701 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
868-702 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
868-703 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
868-704 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure. software
868-705 G 868 Description: Error log analysis
indicates a PCI SCSI adapter failure.software
868-800 G 868 Description: Error log analysis
indicates a PCI SCSI adapter PTC failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
868-802 G 868 Description: Error log analysis
indicates a PCI SCSI bus failure.
Action: Go to Chapter 7. "MAP 0050: SCSI
Problems Isolation Procedure".
887-101 D 887 Description: POS register test failed.
887-102 D 887 Description: I/O register test failed.
887-103 D 887 Description: Local RAM test failed.
887-104 D 887 Description: Vital Product Data (VPD)failed.
887-105 D 887 Description: LAN coprocessor internal tests failed.
887-106 D 887 Description: Internal loopback test failed.
887-107 D 887 Description: External loopback test failed.
887-108 D 887 Description: External loopback test failed.
887-109 D 887 Description: External loopback parity tests failed.
887-110 D 887 Description: External loopback fairness test failed.
887-111 D 887 Description: External loopback fairness and parity tests failed.
887-112 D 887 Description: External loopback (twisted pair) test failed.
887-113 D 887 Description: External loopback (twisted pair) parity test failed.
887-114 D 887 Description: Ethernet loopback (twisted pair) fairness test failed.
887-115 D 887 Description: External loopback (twisted pair) fairness and parity tests failed.
887-116 D 887 Description: Twisted pair wrap data failed ).
887-117 D 887 Description: Device configuration fails.software
887-118 D 887 Description: Device driver indicates a hardware problem.
887-120 D 887 Description: Device driver indicates a hardware problem.
887-121 D B08 Description: Ethernet transceiver test failed.
887-122 B09 Description: Ethernet 10 Base-2 transceiver test failed.
887-123 D 887 Description: Internal loopback test failed.
887-124 G 887 Description: Error log indicates a hardware problem.software
887-125 G 887 Description: Fuse test failed.
887-202 D 887 Description: Vital product data test failed.
887-203 D 887 Description: Vital product data test failed.
887-209 D 887 Description: RJ-45 converter test failed.
887-304 D 887 Description: Coprocessor internal test failed.
887-305 D 887 Description: Internal loopback test failed.
887-306 D 887 Description: Internal loopback test failed.
887-307 D 887 Description: External loopback test failed.
887-319 D 887 Description: Device driver indicates a
hardware failure. software
887-400 D 887 Description: Fuse test failed.
887-401 D 887 Description: Circuit breaker for Ethernet test failed.
887-402 D B09 Description: Ethernet 10 Base-2 transceiver test failed.
887-403 D B08 Description: Ethernet 10 Base-T transceiver test failed.
887-404 D C29 Description: RJ-45 converter test failed.
887-405 F Ethernet Description: Rerun diagnostics in
advanced mode for accurate problem
network determination. 887
89c-111 D 89c Description: Unable to reserve device.
89c-112 D 89c Description: Unable to do configuration.
89c-113 D 89c Description: Unable to open the device driver.
89c-121 D 89c Description: The CD-ROM drive indicates an error.
89c-122 D 89c Description: The CD-ROM drive indicates an error.
89c-123 D 89c Description: The CD-ROM drive indicates an error.
89c-125 D 89c Description: The CD-ROM drive indicates an error.
89c-126 D 89c Description: The CD-ROM drive indicates an error.
89c-127 D 89c Description: The CD-ROM drive indicates an error.
89c-128 D 89c Description: The CD-ROM drive indicates an error.
89c-129 D 89c Description: The CD-ROM drive indicates an error.
89c-150 D Media Description: A media error was detected.
89c-151 D 89c Description: A command timeout was detected.
89c-152 D 89c Description: A command reservation conflict was detected.
89c-162 D 89c Description: The CD-ROM drive indicates an error.
89c-171 D 89c Description: Unable to reserve device.
89c-172 D 89c Description: Unable to do configuration.
89c-173 D 89c Description: Unable to open device driver.
89c-175 D 89c Description: The CD-ROM drive indicates an error.
89c-198 D 89c Description: Undefined error detected.
89c-199 D 89c Description: Undefined error detected.
89c-211 D 89c Description: The LED test failed.
89c-281 D 89c Description: No tone during audio test.
89c-301 G 89c Description: Errors found during ELA.
89c-302 G 89c Description: Errors found during ELA.
900-001 D 900 Description: "NO" to color panel
900-002 D 900 Description: "NO" to cursor panel
900-007 D Info code Description: The EMC_SCROLLING_17_H_TEST failed
900-009 D Info code Description: The EMC_SCROLLING_21_H_TEST failed
900-064 D 900 Description: TRIO64V+_TIMEOUT
900-101 D 900 Description: Color miscompare
900-102 D 900 Description: Clipping error
900-103 D 900 Description: Rectangle fill test failed
900-128 D software Description: MALLOC_ERROR
900-161 D software Description: Loop count value in rules file is zero
900-191 D 900 Description: Red screen error
900-193 D 900 Description: Green screen error
900-1FF D 900 Description: Rectangle fill test failed
900-201 D 900 Description: Color miscompare
900-202 D 900 Description: Clipping error
900-203 D 900 Description: Image transfer across Plane Test failed
900-211 D software Description: INTERNAL_ERROR_DATA_SIZE
900-212 D software Description: INTERNAL_ERROR_NO_ACCESS
900-215 D 900 Description: Black screen error
900-217 D 900 Description: 9 x 7 Cross hatch grid failed.
900-233 D software Description: OPEN_RCM_ERROR
900-234 D software Description: IOCTL_GSC_HANDLE_FAILED
900-235 D software Description: AIXGSC_MAKE_GP_FAILED
900-236 D software Description: AIXGSC_UNMAKE_GP_FAILED
900-237 D software Description: DEVICE_BUSY_ERROR
900-241 D Info code Description: The SCROLLING_17_H_TEST failed.
900-263 D Info code Description: The EMC_SCROLLING_21_H_TEST failed
900-2FF D 900 Description: Image transfer across Plane Test failed
900-301 D 900 Description: A write of "0x00" to the
palette register failed
900-302 D 900 Description: A write of "0x15" to the
palette register failed
900-303 D 900 Description: A write of "0x2A" to the
palette register failed
900-304 D 900 Description: A write of "0x3F" to the
palette register failed
900-305 D 900 Description: The test of the palette
registers failed
900-3FF D 900 Description: The test of the palette
registers failed
900-401 D 900 Description: Frame buffer base address inconsistent
900-402 D 900 Description: VRAM inaccessible
900-403 D 900 Description: Miscompare found in VRAM
900-404 D 900 Description: The test of the VRAM failed
900-447 D 900 Description: Green screen error
900-449 D 900 Description: Blue Screen error
900-471 D 900 Description: 9 x 7 Cross hatch grid failed.
900-473 D 900 Description: 11 x 9 Cross hatch grid failed.
900-495 D Info code Description: The SCROLLING_17_H_TEST failed.
900-497 D Info code Description: The SCROLLING_21_H_TEST failed.
900-4FF D 900 Description: The test of the VRAM failed
900-501 D 900 Description: Color miscompare
900-502 D 900 Description: Clipping error
900-503 D 900 Description: Direct Frame Buffer test failed
900-5FF D 900 Description: Direct Frame Buffer test failed
900-601 D 900 Description: Video Stream Register test failed
900-602 D 900 Description: Video Stream hardware test failed
900-6FF D 900 Description: Video Stream hardware test failed
900-701 D 900 Description: 0 Degree Short Stroke Draw failed
900-702 D 900 Description: 45 Degree Short Stroke Draw failed
900-703 D 900 Description: Blue Screen error, or 90
Degree Short Stroke Draw failed
900-704 D 900 Description: 135 Degree Short Stroke
Draw failed
900-705 D 900 Description: White screen error, or 180
Degree Short Stroke Draw failed
900-706 D 900 Description: 225 Degree Short Stroke
Draw failed
900-707 D 900 Description: 270 Degree Short Stroke
Draw failed
900-708 D 900 Description: 315 Degree Short Stroke
Draw failed
900-709 D 900 Description: Short Stroke Vector
Function test failed
900-727 D 900 Description: 11 x 9 Cross hatch grid failed.
900-750 D Info code Description: The SCROLLING_21_H_TEST failed.
900-753 D Info code Description: The EMC_SCROLLING_17_H_TEST failed
900-7FE D 900 Description: Short Stroke Vector Function test failed
900-7FF D software Description: Bad vector detected 900 227
900-801 D 900 Description: Color for PatBlt thru screen failed
900-802 D 900 Description: Clipping for PatBlt thru screen failed
900-803 D 900 Description: Color for PatBlt Across screen failed
900-804 D 900 Description: Clipping for PatBlt Across screen failed
900-805 D 900 Description: Pattern Fill Across the
Plane test failed
900-8FF D 900 Description: Pattern Fill Across the
Plane test failed
900-901 D 900 Description: Color miscompare of white boxes detected
900-902 D 900 Description: Clipping error of white boxes detected
900-903 D 900 Description: Color miscompare of color bars detected
900-904 D 900 Description: Clipping error of white boxes detected
900-905 D 900 Description: Color miscompare of white boxes detected
900-906 D 900 Description: Clipping error of white boxes detected
900-907 D 900 Description: Color miscompare of white boxes detected
900-908 D 900 Description: Clipping miscompare of white boxes detected
900-909 D 900 Description: The Area fill test (color bars) failed
900-9FF D 900 Description: The Area fill test (color bars) failed
900-937 D 900 Description: Red screen error
900-959 D 900 Description: White screen error
900-961 D 900 Description: Black screen error 227
900-A01 D 900 Description: Color miscompare of
horizontal top line 227
900-A02 D 900 Description: Clipping error of
horizontal top line
900-A03 D 900 Description: Color miscompare of
vertical right line
900-A04 D 900 Description: Clipping error of vertical
right line
900-A05 D 900 Description: Color miscompare of
horizontal bottom line
900-A06 D 900 Description: Clipping error of
horizontal bottom line
900-A07 D 900 Description: Color miscompare of
vertical left line
900-A08 D 900 Description: Clipping error of vertical
left line
900-A09 D 900 Description: Color miscompare of
horizontal center line
900-A0A D 900 Description: Clipping error of
horizontal center line
900-A0B D 900 Description: Color miscompare of
vertical center line
900-A0C D 900 Description: Clipping error of vertical center line
900-A0D D 900 Description: Reserved
900-A0F D 900 Description: Reserved
900-A10 D 900 Description: Color miscompare of textured top line
900-A11 D 900 Description: Clipping error of textured top line
900-A12 D 900 Description: Line Drawing Function test failed
900-AFF D 900 Description: Line Drawing Function test failed
900-B01 D 900 Description: Rectangle Area Color miscompare detected
900-B02 D 900 Description: Rectangle Area Clip error detected
900-B03 D 900 Description: Clipped Area Horizontal
color miscompare (background line color wrong)
900-B04 D 900 Description: Clipped Area Horizontal
clip miscompare (clip of background line wrong)
900-B05 D 900 Description: Clipped Area Vertical color
miscompare (background line color wrong) 227
900-B06 D 900 Description: Clipped Area Vertical clip
error (clip of background line wrong) 227
900-B07 D 900 Description: The clipping function test failed.
900-BFF D 900 Description: The clipping function test failed.
900-C01 D 900 Description: The BIOS read failed. 227
900-C02 D 900 Description: The BIOS function test failed.
900-CFF D 900 Description: The BIOS function test failed.
900-D01 D 900 Description: The HW cursor function test failed.
900-DFF D 900 Description: The HW cursor function test failed.
901-xxx Description: Vendor SCSI device problem.
Refer to the service documentation for
this device.
902-xxx Description: Vendor display problem.
Refer to the service documentation for
this display.
903-xxx Description: Vendor Async device
problem. Refer to the service
documentation for this device.
904-xxx Description: Vendor Parallel device
problem. Refer to the service
documentation for this device.
905-xxx Description: Vendor device problem.
Refer to the service documentation for
this device.
908-001 D 908 Description: Invalid function request or
to C33 bad parameters passed.
908-010 C48
908-016 D 908 Description: MCIC failed reading header.
to
908-019
908-020 D C33 Description: Error closing 7250 DD.
908-111 D 908 Description: Loader check sum error.
908-112 D C33 Description: DMA failed to complete a transfer.
908-113 D 908 Description: Errors in loading ASCII registers.
908-114 D C33 Description: Errors in loading ASCII
to 908 registers.
908-118 C36
908-120 D 908 Description: DMA transfer or PFCA data
to C33 error.
908-150 C36
908-151 D 908 Description: SPAN board error.
to
908-158
908-160 D 908 Description: 7250 is not available. C33 System C36
908-200 D C33 Description: GPSS board failure.
to 908
908-254 C36
908-255 D C33 Description: CP NMI bus timeout
C34 interrupt error. 908 C48
908-256 D C33 Description: GPSS board failure.
to 908
908-454 C36
908-455 D C33 Description: CP NMI bus timeout
908 interrupt error. C34 C48
908-456 D C33 Description: GPSS board failure.
to 908
908-699 C36
908-700 D C34 Description: BLT or RATTLER error.
to C33
908-766 C48
908-767 D C35 Description: VOO feature error.
to C34
908-769 C44
908-770 D C34 Description: RSS BIST failure.
to C33
908-799 C48
908-800 D C46 Description: Base 16M CHAP0 SIMM bad.
908-801 D C45 Description: RSS base 12M CHAP0 SIMM bad
908-802 D C46 Description: RSS AG 16M CHAP0 SIMM bad
908-803 D C45 Description: RSS AG 12M CHAP0 SIMM bad
908-804 D C47 Description: RSS TX 16M CHAP0 SIMM bad
908-805 D C46 Description: Base 16M CHAP 1 SIMM bad
908-806 D C45 Description: RSS base 12M CHAP1 SIMM bad
908-807 D C46 Description: RSS AG 16M CHAP1 SIMM bad
908-808 D C45 Description: RSS AG 12M CHAP1 SIMM bad
908-809 D C47 Description: RSS TX 16M CHAP1 SIMM bad
908-810 D C46 Description: RSS base 16M CHAP2 SIMM bad
908-811 D C45 Description: RSS base 12M CHAP2 SIMM bad
908-812 D C46 Description: RSS AG 16M CHAP2 SIMM bad
908-813 D C45 Description: RSS AG 12M CHAP2 SIMM bad
908-814 D C47 Description: RSS TX 16M CHAP2 SIMM bad
908-815 D C46 Description: RSS base 16M CHAP3 SIMM bad
908-816 D C45 Description: RSS base 12M CHAP3 SIMM bad
908-817 D C46 Description: RSS AG 16M CHAP3 SIMM bad
908-818 D C45 Description: RSS AG 12M CHAP3 SIMM bad
908-819 D C47 Description: RSS TX 16M CHAP3 SIMM bad
908-820 D C46 Description: RSS base 16M CHAP4 SIMM bad
908-821 D C45 Description: RSS base 12M CHAP4 SIMM bad
908-822 D C46 Description: RSS AG 16M CHAP4 SIMM bad
908-823 D C45 Description: RSS AG 12M CHAP4 SIMM bad
908-824 D C47 Description: RSS TX 16M CHAP4 SIMM bad
908-825 D C34 Description: RSS error.
908-830 D C34 Description: Multiple SIMMs failed.
to
908-870
908-871 D D66 Description: RSS error.
to
908-899
908-900 D D66 Description: RSS error.
to C33
908-966 C48
908-967 D C35 Description: VOO error.
to D66
908-969 C48
908-970 D D66 Description: RSS error.
to C33
908-999 C48
912-102 D 912 Description: An unrecoverable media error.
912-104 D 912 Description: The motor failed to restart.
912-105 D 912 Description: The drive did not become ready.
912-106 D 912 Description: The electronics card test failed.
912-108 D 912 Description: The bus test failed.
912-110 D 912 Description: The media format is corrupted.
912-112 D 912 Description: The diagnostic test failed.
912-114 D 912 Description: An unrecoverable hardware error.
912-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
912-117 D 912 Description: A write protect error occurred.
912-118 D 912 Description: A SCSI command time-out. B88
912-120 D 912 Description: A SCSI busy or command error.
912-122 D 912 Description: A SCSI reservation conflict error.
912-124 D 912 Description: A SCSI check condition error.
912-126 D 912 Description: A software error was caused
by a hardware failure.
912-128 G 912 Description: The error log analysis
indicates a hardware failure.
912-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.912 B88 software
912-130 G 912 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
912-132 D 912 Description: A disk drive hardware error occurred.
912-134 D B88 Description: The adapter failed to configure.software
912-137 D 912 Description: Unit attention condition
has occurred on the Send Diagnostic command.
913-102 D 913 Description: An unrecoverable media error.
913-104 D 913 Description: The motor failed to restart.
913-105 D 913 Description: The drive did not become ready.
913-106 D 913 Description: The electronics card test failed.
913-108 D 913 Description: The bus test failed.
913-110 D 913 Description: The media format is corrupted.
913-112 D 913 Description: The diagnostic test failed.
913-114 D 913 Description: An unrecoverable hardware error.
913-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
913-117 D 913 Description: A write protect error occurred.
913-118 D 913 Description: A SCSI command time-out. B88
913-120 D 913 Description: A SCSI busy or command error.
913-122 D 913 Description: A SCSI reservation conflict error.
913-124 D 913 Description: A SCSI check condition error.
913-126 D 913 Description: A software error was caused
by a hardware failure. B88
913-128 G 913 Description: The error log analysis
indicates a hardware failure.
913-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 913
913-130 G 913 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
913-132 D 913 Description: A disk drive hardware error occurred.
913-134 D B88 Description: The adapter failed to configure.software
913-137 D 913 Description: Unit attention condition
has occurred on the Send Diagnostic command. D50
914-110 D 914 Description: The Reserve command failed.
914-120 D 914 Description: The Inquiry command failed.
914-130 D 914 Description: The Load command failed. media
914-135 D 914 Description: The Unload command failed.media
914-140 D 914 Description: The Mode Select command failed.
914-150 D 914 Description: The Test Unit Ready command failed.media
914-160 D 914 Description: The Send Diagnostic command failed.media
914-170 D 914 Description: The Read, Write and Compare test failed.media
914-180 D 914 Description: The Load command failed. media
914-185 D 914 Description: The Unload command failed. media
914-190 D 914 Description: The Mode Select command failed.
914-200 D 914 Description: The Test Unit Ready command failed.media
914-210 D 914 Description: The device configuration failed.B88
914-220 D 914 Description: The Release command failed.
914-230 D 914 Description: The Request Sense command failed.
914-240 D 914 Description: The Openx command failed.
914-300 D 914 Description: The device configuration failed.software
914-310 D B88 Description: SCSI adapter configuration failed.
914-320 G 914 Description: Error log analysis
indicates a failure. media
914-411 D 914 Description: A reservation conflict
to occurred.
914-423 B88 software
914-511 D 914 Description: The drive returned bad or
to non-extended sense data.
914-523 B88
914-611 D 914 Description: An adapter or bus I/O error
to occurred.
914-623 B88 software
914-711 D 914 Description: A device timeout error
to occurred.
914-723 B88 software
915-110 D 915 Description: The Reserve command is corrupted.
915-120 D 915 Description: The Inquiry command failed.
915-130 D 915 Description: The Load command failed. media
915-135 D 915 Description: The Unload command failed. media
915-140 D 915 Description: The Mode Select command failed.
915-150 D 915 Description: The Test Unit Ready command failed.media
915-160 D 915 Description: The Send Diagnostic command failed.
915-169 D 915 Description: The send diagnostic command failed. media
915-170 D 915 Description: The Read, Write and Compare
test failed. B88 media
915-180 D 915 Description: The Load command failed. media
915-185 D 915 Description: The Unload command failed.media
915-190 D 915 Description: The Mode Select command failed.
915-200 D 915 Description: The Test Unit Ready command failed. media
915-210 D 915 Description: The device configuration failed.
915-220 D 915 Description: The Replace command failed.
915-230 D 915 Description: The Request Sense command failed.
915-240 D 915 Description: The Openx command failed.
915-300 D 915 Description: The device configuration failed. software
915-310 D B88 Description: SCSI adapter configuration failed.
915-320 G 915 Description: Error log analysis indicates a failure.
915-411 D 915 Description: A reservation conflict
to occurred.
915-423 B88 software
915-511 D 915 Description: The drive returned bad or
to non-extended sense data.
915-523 B88
915-611 D 915 Description: An adapter or bus I/O error
to occurred.
915-623 B88 software
915-711 D 915 Description: A device timeout error
to occurred.
915-723 B88 software
917-102 D 917 Description: An unrecoverable media error.
917-104 D 917 Description: The motor failed to restart.
917-105 D 917 Description: The drive did not become ready.
917-106 D 917 Description: The electronics card test failed.
917-108 D 917 Description: The bus test failed.
917-110 D 917 Description: The media format is corrupted.
917-112 D 917 Description: The diagnostic test failed.
917-114 D 917 Description: An unrecoverable hardware error.
917-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
917-117 D 917 Description: A write protect error occurred.
917-118 D 917 Description: A SCSI command time-out. B88
917-120 D 917 Description: A SCSI busy or command error.
917-122 D 917 Description: A SCSI reservation conflict error.
917-124 D 917 Description: A SCSI check condition error.
917-126 D 917 Description: A software error was caused
by a hardware failure. B88
917-128 G 917 Description: The error log analysis
indicates a hardware failure.
917-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. software
917-130 G 917 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
917-132 D 917 Description: A disk drive hardware error occurred.
917-134 D B88 Description: The adapter failed to configure.software
917-135 D 917 Description: The device failed to configure.B88 software
917-136 D 917 Description: The certify operation failed.
917-137 D 917 Description: Unit attention condition
has occurred on the Send Diagnostic command.
918-102 D 918 Description: An unrecoverable media error.
918-104 D 918 Description: The motor failed to restart.
918-105 D 918 Description: The drive did not become ready.
918-106 D 918 Description: The electronics card test failed.
918-108 D 918 Description: The bus test failed.
918-110 D 918 Description: The media format is corrupted.
918-112 D 918 Description: The diagnostic test failed.
918-114 D 918 Description: An unrecoverable hardware error.
918-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
918-117 D 918 Description: A write protect error occurred.
918-118 D 918 Description: A SCSI command time-out.B88
918-120 D 918 Description: A SCSI busy or command error.
918-122 D 918 Description: A SCSI reservation conflict error.
918-124 D 918 Description: A SCSI check condition error.
918-126 D 918 Description: A software error was caused
by a hardware failure. B88
918-128 G 918 Description: The error log analysis
indicates a hardware failure.
918-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 918 software
918-130 G 918 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
918-132 D 918 Description: A disk drive hardware error occurred.
918-134 D B88 Description: The adapter failed to configure.software
918-135 D 918 Description: The device failed to configure.
918-136 D 918 Description: The certify operation failed.
918-137 D 918 Description: Unit attention condition
has occurred on the Send Diagnostic command.
921-101 D 821 Description: An unexpected adapter error occurred.
921-102 D 921 Description: An unexpected device or
adapter error occurred. 821
921-103 D 921 Description: The keyboard reset failed.
921-104 D 921 Description: Unknown keyboard.
921-105 D 921 Description: The keyboard light on test failed.
921-106 D 921 Description: The keyboard light off test failed.
921-201 D 821 Description: An unexpected adapter error occurred.
921-202 D 921 Description: An unexpected device or
adapter error occurred. 821
921-203 D 921 Description: The read keyboard ID test failed.
921-204 D 921 Description: The keyboard layout ID test failed.
921-205 D 921 Description: The keyboard echo test failed.
921-206 D 921 Description: The select scan code set test failed.
921-301 D 821 Description: An unexpected adapter error occurred.
921-302 D 921 Description: An unexpected device or
adapter error occurred.
921-303 D 921 Description: An error occurred in
turning on the lamps.
921-304 D 921 Description: An error occurred in
turning off the lamps.
921-401 D 821 Description: An unexpected adapter error occurred.
921-402 D 921 Description: An unexpected device or
adapter error occurred. 821
921-403 D 921 Description: Unable to recognize the keyboard.
921-404 D 921 Description: The keyboard is failing. 821
921-501 D 821 Description: An unexpected adapter error occurred.
921-502 D 921 Description: An unexpected device or
adapter error occurred. 821
921-503 D 921 Description: The auto-click cannot be disabled.
921-504 D 921 Description: The auto-click cannot be enabled.
921-505 D 921 Description: Unable to recognize the keyboard.
921-601 D 821 Description: An unexpected adapter error occurred.
921-602 D 921 Description: An unexpected device or adapter error occurred.
921-603 D 921 Description: The speaker test failed.
921-701 D 921 Description: Error configuring the device. 821
921-901 G 821 Description: The error log analysis
indicates an adapter failure.
921-902 G 921 Description: The error log analysis
indicates a device failure. 821
921-903 G 921 Description: The error log analysis
indicates an unknown failure. 821
922-101 D 821 Description: An unexpected adapter error occurred.
922-102 D 922 Description: An unexpected device
or adapter error occurred. 821
922-103 D 922 Description: The keyboard reset failed.821
922-104 D 922 Description: Unknown keyboard.
922-105 D 922 Description: The keyboard light on test failed.
922-106 D 922 Description: The keyboard light off test failed.
922-201 D 821 Description: An unexpected adapter error occurred.
922-202 D 922 Description: An unexpected device or adapter error occurred.
922-203 D 922 Description: The read keyboard id test failed.
922-204 D 922 Description: The keyboard layout id test failed.
922-205 D 922 Description: The keyboard echo test failed.
922-206 D 922 Description: The select scan code set test failed.
922-301 D 821 Description: An unexpected adapter error occurred.
922-302 D 922 Description: An unexpected device or
adapter error occurred. 821
922-303 D 922 Description: An error occurred in
turning on the lamps.
922-304 D 922 Description: An error occurred in
turning off the lamps.
922-401 D 821 Description: An unexpected adapter error occurred.
922-402 D 922 Description: An unexpected device or
adapter error occurred. 821
922-403 D 922 Description: The keyboard is failing.
922-404 D 922 Description: Unable to recognize the keyboard.
922-501 D 821 Description: An unexpected adapter error occurred.
922-502 D 922 Description: An unexpected device or
adapter error occurred.
922-503 D 921 Description: The auto-click cannot be disabled.
922-504 D 922 Description: The auto-click cannot be enabled.
922-505 D 922 Description: Unable to recognize the keyboard.
922-601 D 821 Description: An unexpected adapter error occurred.
922-602 D 922 Description: An unexpected device or
adapter error occurred. 821
922-603 D 922 Description: The speaker test failed.
922-701 D 922 Description: Error configuring the device.
922-901 G 821 Description: The error log indicates an adapter failed.
922-902 G 922 Description: The error log indicates a device failed.
922-903 G 922 Description: The error log analysis
indicates an unknown failure. 821
923-101 D 821 Description: An unexpected adapter error occurred.
923-102 D 923 Description: An unexpected device or
adapter error occurred. 821
923-103 D 923 Description: The keyboard reset failed. 821
923-104 D 923 Description: Unknown keyboard.
923-105 D 923 Description: The keyboard light on test failed.
923-106 D 923 Description: The keyboard light off test failed.
923-201 D 821 Description: An unexpected adapter error occurred.
923-202 D 923 Description: An unexpected device or
adapter error occurred. 821
923-203 D 923 Description: The read keyboard id test failed.
923-204 D 923 Description: The keyboard layout id test failed.
923-205 D 923 Description: The keyboard echo test failed. 821
923-206 D 923 Description: The select scan code set test failed.
923-301 D 821 Description: An unexpected adapter error occurred.
923-302 D 923 Description: An unexpected device or
adapter error occurred. 821
923-303 D 923 Description: An error occurred in
turning on the lamps.
923-304 D 923 Description: An error occurred in
turning off the lamps.
923-401 D 821 Description: An unexpected adapter error occurred.
923-402 D 923 Description: An unexpected device or
adapter error occurred.
923-403 D 923 Description: The keyboard is failing.
923-404 D 923 Description: Unable to recognize the keyboard.
923-501 D 821 Description: An unexpected adapter error occurred.
923-502 D 923 Description: An unexpected device or
adapter error occurred. 821
923-503 D 923 Description: The auto-click cannot be disabled.
923-504 D 923 Description: The auto-click cannot be enabled.
923-505 D 923 Description: Unable to recognize the keyboard.
923-601 D 821 Description: An unexpected adapter error occurred.
923-602 D 923 Description: An unexpected device or
adapter error occurred. 821
923-603 D 923 Description: The speaker test failed.
922-701 D 923 Description: Error configuring the device.
923-901 G 821 Description: The error log indicates an adapter failed.
923-902 G 923 Description: The error log analysis
indicates a device failure. 821
923-903 G 923 Description: The error log analysis
indicates an unknown failure. 821
925-111 D 925 Description: An unexpected device error occurred.
925-112 D 925 Description: The device disable test failed.
925-113 D 925 Description: Could not reset the device.
925-114 D 925 Description: The read status command failed.
925-115 D 925 Description: The device test failed.
925-116 D 925 Description: Unknown Mouse type.
925-117 D 925 Description: Mouse wrap mode failed. 823
925-118 D 925 Description: Error setting mouse parameters.
925-121 D 925 Description: The device test failed.
to
925-171
925-200 D 925 Description: A software error was caused
by a hardware failure.
925-300 G 925 Description: The error log analysis
indicates a hardware failure.
925-301 G 925 Description: The error log analysis
indicates a hardware failure. 823
926-104 D 926 Description: Input device cable is not
attached. 159
926-111 D 824 Description: Adapter error.
926-112 D 926 Description: Device, adapter or tablet
to reset failed. 824
926-115
926-116 D 159 Description: The input device cable is not attached.
926-119 D 188 Description: The input device cable is not attached.
926-121 D 824 Description: Adapter error.
926-131 D 824 Description: Adapter error.926
926-132 D 926 Description: Device or adapter error.
to
926-135
926-141 D 824 Description: Adapter error. 926
926-142 D 926 Description: Device or adapter error.
to
926-161
926-162 D 159 Description: Device or adapter error.926
926-163 D 159 Description: Error in turning off input device LED.
926-164 D 159 Description: Error in turning off input device LED.
926-165 D 159 Description: The input device cable is not attached.
926-166 D 188 Description: Device or adapter error. 926
926-167 D 188 Description: Error in turning off input device LED.
926-168 D 188 Description: Error in turning on input device LED.
926-169 D 188 Description: The input device cable is not attached.
926-172 D 159 Description: Device or adapter error. 926
926-173 D 159 Description: Error in turning off input device switch.
926-174 D 159 Description: Error in turning on input device switch.
926-175 D 159 Description: The input device cable is not attached.
926-176 D 188 Description: Device or adapter error. 926
926-177 D 188 Description: Error in turning off input device switch.
926-178 D 188 Description: Error in turning on input device switch.
926-179 D 188 Description: The input device cable is not attached.
926-181 D 824 Description: Adapter error. 926
926-182 D 159 Description: Device or adapter error. 926
926-183 D 159 Description: Error in incremental data mode test.
926-184 D 159 Description: The input device cable is not attached.
926-186 D 188 Description: Device or adapter error. 926
926-187 D 188 Description: The incremental data mode test failed.
926-188 D 188 Description: The input device cable is not attached.
926-203 D 926 Description: Error in disabling tablet. 824
926-204 D 926 Description: Error in enabling tablet. 824>
926-207 D 926 Description: Enabled/disabled test failed.
926-208 D 926 Description: Enabled/disabled test failed.
926-221 D 824 Description: Adapter error.
926-222 D 926 Description: Device or adapter error.824
926-225 D 159 Description: The input device cable is not attached.
926-229 D 188 Description: The input device cable is not attached.
926-271 D 926 Description: Adapter error.
926-272 D 159 Description: Device or adapter error.
926-273 D 159 Description: Error in input device switch test.
926-274 D 159 Description: The input device cable is not attached.
926-276 D 188 Description: Device or adapter error. 926
926-277 D 188 Description: Error in input device switch test.
926-278 D 188 Description: Input device cable is not attached.
926-281 D 824 Description: Adapter error. 926
926-282 D 159 Description: Device or adapter error. 926
926-283 D 159 Description: Error in incremental data mode test.
926-284 D 159 Description: The input device cable is not attached.
926-286 D 188 Description: Device or adapter error. 926
926-287 D 188 Description: Error in incremental data mode test.
926-288 D 188 Description: The input device cable is not attached.
927-104 D 927 Description: The input device cable is not attached.
927-111 D 824 Description: Adapter error.
927-112 D 927 Description: Device or adapter error.824
927-113 D 927 Description: Tablet reset failed. 824
927-114 D 927 Description: The read configuration test failed.824
927-115 D 927 Description: The read status test failed. 824
927-116 D 159 Description: The input device cable is not attached.
927-119 D 188 Description: The input device cable is not attached.
927-121 D 824 Description: Adapter error.
927-122 D 927 Description: Device or adapter error. 824
927-125 D 927 Description: The input device cable is not attached.
927-131 D 824 Description: Adapter error. 927
927-132 D 927 Description: Device or adapter error.
927-133 D 927 Description: The set conversion mode test failed.
927-134 D 927 Description: The set resolution test failed.
927-135 D 927 Description: The read status test failed.
927-141 D 824 Description: Adapter error. 927
927-142 D 927 Description: Device or adapter error.
927-143 D 927 Description: Error in tablet indicator.
927-161 D 927 Description: Adapter error.
927-162 D 159 Description: Device or adapter error. 927
927-163 D 159 Description: Error in turning off input device LED.927
927-164 D 159 Description: Error in turning on input device LED. 927
927-165 D 159 Description: The input device cable is not attached.
927-166 D 188 Description: Device or adapter error. 927
927-167 D 188 Description: Error in turning off input device LED.
927-168 D 188 Description: Error in turning on input device LED.
927-169 D 188 Description: The input device cable is not attached.
927-171 D 927 Description: Adapter error.
927-172 D 159 Description: Device or adapter error. 927
927-173 D 159 Description: Error in turning off input device switch.
927-174 D 159 Description: Error in turning on input device switch.
927-175 D 159 Description: The input device cable is not attached.
927-176 D 188 Description: Device or adapter error. 927
927-177 D 188 Description: Error in turning off input device switch.
927-178 D 188 Description: Error in turning on input device switch.
927-179 D 188 Description: The input device cable is not attached.
927-181 D 824 Description: Adapter error. 927
927-182 D 159 Description: Device or adapter error. 927
927-183 D 159 Description: Error in incremental data mode test.
927-184 D 159 Description: The input device cable is not attached.
927-186 D 188 Description: Device or adapter error. 927
927-187 D 188 Description: Error in incremental data mode test.
927-188 D 188 Description: The input device cable is not attached.
927-203 D 927 Description: Error in disabling tablet. 824
927-204 D 927 Description: Error in enabling tablet. 824
927-221 D 824 Description: Adapter error.
927-222 D 927 Description: Device or adapter error. 824
927-225 D 159 Description: The input device cable is not attached.
927-229 D 188 Description: The input device cable is not attached.
927-271 D 927 Description: Adapter error.
927-272 D 159 Description: Device or adapter error. 927
927-273 D 159 Description: Error in input device switch test.
927-274 D 159 Description: The input device cable is not attached.
927-276 D 188 Description: Device or adapter error. 927
927-277 D 188 Description: Error in input device switch test.
927-278 D 188 Description: The input device cable is not attached.
927-281 D 824 Description: Adapter error. 927
927-282 D 159 Description: Device or adapter error.
927-283 D 159 Description: Error in incremental data mode test.
927-284 D 159 Description: The input device cable is not attached.
927-286 D 188 Description: Device or adapter error. 927
927-287 D 188 Description: Error in incremental data mode test.
927-288 D 188 Description: The input device cable is not attached.
929-201 D 929 Description: Failed to register input ring
929-202 D 929 Description: Unable to read event from the device
929-203 D 929 Description: Unable to communicate with the device.
929-204 D 929 Description: Cannot set the device granularity
929-210 D 929 Description: Device or adapter failure
929-212 D 929 Description: Cannot set the device to HIGH granularity
929-213 D 929 Description: Cannot set the device to LOW granularity
929-299 D software Description: Error unconfiguring the device 929
929-301 D software Description: Error configuring the device 929
930-201 D 930 Description: Device or adapter failure
930-210 G 930 Description: Unable to turn the lights on
930-220 G 930 Description: Unable to turn the lights off hardware failure.
930-230 D 930 Description: Unable to turn the lights off
930-241 D 930 Description: Unable to turn a single light on
930-242 D 930 Description: Device or adapter failure
930-243 D 930 Description: Device or adapter failure
930-261 D 930 Description: Cable test failed
930-262 D 930 Description: Cable test failed
930-299 D software Description: Error unconfiguring the device
930-301 D software Description: Error configuring the device0
935-101 D 935 Description: The diskette-drive select
to or deselect test failed.
935-102
935-103 D 935 Description: The diskette failed.
to
935-107
935-108 D 935 Description: The diskette read test failed.
935-109 D 935 Description: The read/write on the
to diskette drive failed.
935-110
935-111 D 935 Description: A diskette drive test
to failed.
935-114
935-115 D 935 Description: The diskette drive test
to failed.
935-121
935-122 G 935 Description: The error log analysis
indicates a hardware failure. 828
935-123 G 935 Description: The error log analysis
indicates a hardware failure.
935-124 D 935 Description: Unable to configure the
device. software
945-102 D 990 Description: 1GB 16-bit SCSI
to differential disk drive problem.
945-114
945-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
945-117 D 990 Description: A write protect error occurred.
945-118 D 990 Description: A SCSI command time-out.B88
945-120 D 990 Description: 1GB 16-bit SCSI
to differential disk drive problem.
945-124
945-126 D 990 Description: A software error was caused
by a hardware failure. B88
945-128 G 990 Description: The error log analysis
indicates a hardware failure.
945-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.945 B88 software
945-130 G 945 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
945-132 D 990 Description: A disk drive hardware error occurred.
945-134 D B88 Description: The adapter failed to configure. software
945-136 D 990 Description: The certify operation failed.
945-137 D 945 Description: Unit attention condition
has occurred on the Send Diagnostic
command.D50
946-111 D 946 Description: Cannot run the test
because the device driver detected a
hardware error.
946-114 D 946 Description: The register verification test failed.
946-121 D 946 Description: Cannot run the test
because the device driver detected a
hardware error.
946-122 D 946 Description: The data wrap communications test failed.
946-123 D 946 Description: The modem control line test failed.
946-131 D 946 Description: Cannot run the test
because the device driver detected a
hardware error.
946-132 D 946 Description: The data wrap communications test failed.
946-133 D 946 Description: The modem control line test failed.
946-161 D 252 Description: Could not do the test
because the device driver detected a
hardware error.
946-162 D 252 Description: The data wrap communication test failed.
946-163 D 252 Description: The modem control line test failed.
946-171 D 259 Description: Cannot run the test
because the device driver detected a
hardware error.
946-172 D 259 Description: The data wrap communications test failed.
946-173 D 259 Description: The modem control line test failed.
946-181 D 261 Description: Cannot run the test
because the device driver detected a
hardware error.
946-182 D 261 Description: The data wrap communications test failed.
946-183 D 261 Description: The modem control line test failed.
946-271 D 946 Description: Cannot run the test because the device
driver detected a hardware error.
946-272 D 946 Description: The data wrap communication test failed.
946-273 D 946 Description: The modem control line test failed.
946-281 D 946 Description: Cannot run the test
because the device driver detected a hardware error.
946-282 D 946 Description: The data wrap communications test failed.
946-283 D 946 Description: The modem control line test failed.
946-321 D 946 Description: Cannot run the test
because the device driver detected a hardware error.
946-322 D 946 Description: The data wrap communications test failed.
946-323 D 946 Description: The modem control line test failed.
946-331 D 946 Description: Cannot run the test because the
device driver detected a hardware error.
946-332 D 946 Description: The data wrap communications test failed.
946-333 D 946 Description: The modem control line test failed.
946-371 D 946 Description: Cannot run the test
because the device driver detected a hardware error.
946-372 D 946 Description: The data wrap communications test failed.
946-373 D 946 Description: The modem control line test failed.
946-381 D 946 Description: Cannot run the test
because the device driver detected a hardware error.
946-382 D 946 Description: The data wrap communications test failed.
946-383 D 946 Description: The modem control line test failed.
946-481 D D56 Description: Could not do the test
because the device driver detected a hardware error.
946-482 D D56 Description: The data wrap communication test failed.
946-483 D D56 Description: The modem control line test failed.
946-581 D 946 Description: Could not do the test
because the device driver detected a hardware error.
946-582 D 946 Description: The data wrap communication test failed.
946-583 D 946 Description: The modem control line test failed.
946-901 D software Description: An unexpected error
to occurred that can be attributed to software or hardware.
946-920 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 946; otherwise,
suspect a software problem.
946-921 D 946 Description: The adapter failed to configure software
946-922 D software Description: An unexpected error
to occurred that can be attributed to software or hardware.
946-924 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 946; otherwise,
suspect a software problem.
946-925 D 946 Description: The adapter failed to configure software
946-926 D software Description: An unexpected error
to occurred that can be attributed to software or hardware.
946-943 Action: Run diagnostics from a source
other than from the disk or a network. If
the same error occurs or if the original
SRN was not obtained from disk or a
network based diagnostics, use Chapter
12. "MAP 0210: General Problem
Resolution" with a FFC of 946; otherwise,
suspect a software problem.
950-100 C 192 Description: Power supply problem.
Action: Use the service documentation for
the portable disk.
950-101 F 2C9 Description: PCI bus was not found.
Action: Rerun diagnostics in Advanced
Mode for additional problem isolation.
950-102 C 2C9 Description: PCI bus was not found.
950-103 C 2C9 Description: Multiple adapters on bus were not found.
950-105 C 2C9 Description: PCI bus was not found. 221
950-106 C 2C9 Description: PCI bus was not found.
950-107 C 153 Description: The device is not responding
165 Action: For devices located in
drawer/deskside units, use the service
documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-108 C 201 Description: The device is not
responding. Action: For devices located
199 in drawer/deskside units, use the service
documentation for the drawer/deskside
153 unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
165 Resolution".
950-200 C 203 Description: Power supply problem.
Action: Use the service documentation for
the external device.
950-201 C SCSI Bus Description: SCSI bus problem.
Action: Refer to MAP 2010 in the 7134
High Density SCSI Disk Subsystem
Installation and Service Guide.
950-400 C 153 Description: Power supply problem.
Action: Use the service documentation for
the drawer/tower containing the failing
power supply. If the drawer/deskside unit
service documentation does not isolate
the problem, go to MAP 1520 in the system
unit installation and service guide.
950-500 C 152 Description: Power supply problem.
Action: Use the service documentation for
either the system unit, rack or
drawer/deskside unit the missing device
is located in.
950-679 C 679 Description: The SCSI Disk Drive is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
190 documentation for the drawer/deskside
unit. For all other locations, use
199 Chapter 12. "MAP 0210: General Problem
Resolution". 152
950-700 C 700 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-701 C 701 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-702 C 702 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-703 C 703 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-704 C 704 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-705 C 705 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-706 C 706 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-707 C 707 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-721 C 721 Description: An unknown drive type is not responding.
950-722 C 722 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-723 C 723 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-724 C 724 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-734 C 734 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-741 C 741 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-772 C 772 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
199 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
152 Resolution".
950-773 C 773 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-789 C 789 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-792 C 792 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-793 C 793 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-804 C 804 Description: The device is not responding.
B88 Action: For devices located in
drawer/deskside units, use the service
152 documentation for the drawer/deskside
unit. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-912 C 912 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-914 C 914 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-915 C 915 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-917 C 917 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-918 C 918 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-935 C 935 Description: Device does not respond.828 52 199
950-936 C 936 Description: Device does not respond. 828 152
950-951 C 951 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-952 C 952 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-953 C 953 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-954 C 954 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-955 C 955 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
141 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
152 Resolution". If the drawer/deskside unit
service documentation does not isolate
the problem, go to Chapter 12. "MAP 0210:
General Problem Resolution".
950-956 C 956 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-959 C 959 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-960 C 960 Description: Device does not respond. B88 152
950-968 C 968 Description: Device does not respond. B88 152
950-970 C 970 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-971 C 971 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-972 C 972 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-974 C 974 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-981 C 981 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. Refer to "Drawer/Deskside Unit
Documentation" under Service Hints in
Chapter 1. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-984 C 984 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-986 C 986 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-987 C 974 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-989 C 989 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-990 C 990 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-991 C 991 Description: Device does not respond.
950-994 C 994 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-995 C 995 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-998 C 998 Description: Device does not respond.
Action: For devices located in
B88 drawer/deskside units, use the service
documentation for the drawer/deskside
152 units. For all other locations, use
Chapter 12. "MAP 0210: General Problem
Resolution".
950-xxx C xxx Description: The device does not respond.
(See note B88 Action: For devices located in
in the drawer/deskside units, use the service
152 documentation for the drawer/deskside
Action units. Refer to "Drawer/Deskside Unit
col.) Documentation" under Service Hints in
Chapter 1. For all other locations use
Chapter 12. "MAP 0210: General Problem
Resolution".
Note: If your 950-xxx SRN is listed in
this section, use the procedure for that
SRN instead of this one. Otherwise, to
obtain the FFC substitute the last three
digits of the SRN for xxx. (The
substituted three digit number is the FFC.)
951-098 J 951 Description: Disk drive indicates an error
951-099 J 951 Description: Disk drive not found.
951-102 D 951 Description: An unrecoverable media error.
951-104 D 951 Description: The motor failed to restart.
951-105 D 951 Description: The drive did not become ready.
951-106 D 951 Description: The electronics card test failed.
951-108 D 951 Description: The bus test failed.
951-110 D 951 Description: The media format is corrupted.
951-112 D 951 Description: The diagnostic test failed.
951-114 D 951 Description: An unrecoverable hardware error.
951-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to ensure they are
all compatible. If you do not find a
problem, call your support person.
951-117 D 951 Description: A write protect error occurred.
951-118 D 951 Description: A SCSI command timeout.
951-120 D 951 Description: A SCSI busy or command error.
951-122 D 951 Description: A SCSI reservation conflict error.
951-124 D 951 Description: A SCSI check condition error.
951-126 D 951 Description: A software error was caused by a hardware failure.
951-128 G 951 Description: The error log analysis indicates a hardware failure.
951-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.951 B88 software
951-130 G 951 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
951-132 D 951 Description: A disk drive hardware error occurred.
951-134 D B88 Description: The adapter failed to configure. software
951-135 D 951 Description: The device failed to configure.software
951-136 D 951 Description: The certify operation failed.
951-137 D 951 Description: Unit attention condition
has occurred on the Send Diagnostic command.
952-098 J 952 Description: Disk drive indicates an error.
952-099 J 952 Description: Disk drive not found.
952-102 D 952 Description: An unrecoverable media error.
952-104 D 952 Description: The motor failed to restart.
952-105 D 952 Description: The drive did not become ready.
952-106 D 952 Description: The electronics card test failed.
952-108 D 952 Description: The bus test failed.
952-110 D 952 Description: The media format is corrupted.
952-112 D 952 Description: The diagnostic test failed.
952-114 D 952 Description: An unrecoverable hardware error.
952-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
952-117 D 952 Description: A write protect error occurred.
952-118 D 952 Description: A SCSI command timeout.
952-120 D 952 Description: A SCSI busy or command error.
952-122 D 952 Description: A SCSI reservation conflict error.
952-124 D 952 Description: A SCSI check condition error.
952-126 D 952 Description: A software error was
caused by a hardware failure.
952-128 G 952 Description: The error log analysis
indicates a hardware failure.
952-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 952 b88 software
952-130 G 952 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
952-132 D 952 Description: A disk drive hardware error occurred.
952-134 D B88 Description: The adapter failed to configure.software
952-135 D 952 Description: The device failed to configure.Software
952-136 D 952 Description: The certify operation failed.
952-137 D 952 Description: Unit attention condition
has occurred on the Send Diagnostic command. D50
953-098 J 953 Description: Disk drive indicates an error.
953-099 J 953 Description: Disk drive not found.
953-102 D 953 Description: An unrecoverable media error.
953-104 D 953 Description: The motor failed to restart.
953-105 D 953 Description: The disk drive did not become ready.
953-106 D 953 Description: The electronics card test failed.
953-108 D 953 Description: The bus test failed.
953-110 D 953 Description: The media format is corrupted.
953-112 D 953 Description: The diagnostic test failed.
953-114 D 953 Description: An unrecoverable hardware error.
953-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
953-117 D 953 Description: A write protect error.
953-118 D 953 Description: A SCSI command timeout.
953-120 D 953 Description: A SCSI busy or command error.
953-122 D 953 Description: A SCSI reservation conflict error.
953-124 D 953 Description: A SCSI check condition error.
953-126 D 953 Description: A software error was
caused by a hardware failure. B88
953-128 G 953 Description: The error log analysis
indicates a hardware failure.
953-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 953 B88 software
953-130 G 953 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
953-132 D 953 Description: A disk drive hardware error occurred.
953-134 D B88 Description: The adapter failed to configure. software
953-135 D 953 Description: The device failed to configure.B88 software
953-136 D 953 Description: The certify operation failed.
953-137 D 953 Description: Unit attention condition
has occurred on the Send Diagnostic command.
954-098 J 954 Description: Disk drive indicates an error.
954-099 J 954 Description: Disk drive not found.
954-102 D 954 Description: An unrecoverable media error.
954-104 D 954 Description: Motor failed to restart.
954-105 D 954 Description: The disk drive did not become ready.
954-106 D 954 Description: Electronics card failure.
954-108 D 954 Description: Bus failure.
954-110 D 954 Description: The media format is corrupted.
954-112 D 954 Description: Diagnostic failure.
954-114 D 954 Description: An unrecoverable hardware error.
954-116 D Description: A protocol error was detected.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software, ensure that they
are all compatible. If you do not find a
problem, call your support person.
954-117 D 954 Description: Write protect error.
954-118 D 954 Description: SCSI command timeout.
954-120 D 954 Description: SCSI busy/command error.
954-122 D 954 Description: SCSI reservation conflict error.
954-124 D 954 Description: SCSI check condition error.
954-126 D 954 Description: Software error caused by hardware failure.
954-128 G 954 Description: Error log analysis indicates hardware failure.
954-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.954 B88 software
954-130 G 954 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
954-132 D 954 Description: A disk drive hardware error occurred.
954-134 D B88 Description: The adapter failed to configure.software
954-135 D 954 Description: The device failed to configure. software
954-136 D 954 Description: The certify operation failed.
954-137 D 954 Description: Unit attention condition
has occurred on the Send Diagnostic command. D50
955-098 J 955 Description: Disk drive indicates an error.
955-099 J 955 Description: Disk drive not found.
955-102 D 955 Description: A media error was encountered.141
955-104 D 955 Description: The motor failed to restart.
141 Action: For devices installed in a
drawer/deskside unit, use the
drawer/deskside unit documentation. Refer
to "Drawer/Deskside Unit Documentation"
under Hints in Chapter 1. For other
locations, go to MAP 0210. If the
electronics card has been exchanged,
exchange the adapter first. If the
drawer/deskside unit documentation does
not isolate the problem, go to MAP 0210.
955-105 D 955 Description: The disk drive did not become ready.
955-106 D 955 Description: The electronics card failed. 141
955-108 D 955 Description: The bus test failed.
955-110 D 955 Description: The media format is corrupted.141
955-112 D 955 Description: The diagnostic test failed. 141
955-114 D 955 Description: An unrecoverable hardware error. 141
955-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
955-118 D 955 Description: A SCSI command timeout. B88
955-120 D 955 Description: A SCSI busy or command error. B88
955-122 D 955 Description: A SCSI reservation conflict error.
955-124 D 955 Description: A SCSI check condition error. B88
955-126 D 955 Description: A software error was
caused by a hardware failure. B88
955-128 G 955 Description: The error log analysis
indicates a hardware failure. 141
955-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 955 B88 software
955-130 G 955 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
955-132 D 955 Description: A disk drive hardware error occurred.
955-134 D B88 Description: The adapter failed to
configure. software
955-135 D 955 Description: The device failed to
configure. software
955-136 D 955 Description: The certify operation failed. 141
955-137 D 955 Description: Unit attention condition
has occurred on the Send Diagnostic command. D50
956-102 D 956 Description: An unrecoverable media error.
956-104 D 956 Description: The motor failed to restart.
956-105 D 956 Description: The drive did not become ready.
956-106 D 956 Description: The electronics card test failed.
956-108 D 956 Description: The bus test failed.
956-110 D 956 Description: The media format is corrupted.
956-112 D 956 Description: The diagnostic test failed.
956-114 D 956 Description: An unrecoverable hardware error.
956-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
956-117 D 956 Description: A write protect error occurred.
956-118 D 956 Description: A SCSI command time-out.
956-120 D 956 Description: A SCSI busy or command error.
956-122 D 956 Description: A SCSI reservation conflict error.
956-124 D 956 Description: A SCSI check condition error.
956-126 D 956 Description: A software error was caused
by a hardware failure.
956-128 G 956 Description: The error log analysis
indicates a hardware failure.
956-130 G 956 Description: The error log analysis
indicates a hardware failure.
956-132 D 956 Description: A disk drive hardware error occurred.
956-134 D B88 Description: The adapter failed to configure.software
956-136 D 956 Description: The certify operation failed.
959-098 J 959 Description: Disk drive indicates an error.
959-099 j 959 Description: Disk drive not found.
959-102 D 959 Description: Non-recoverable medium error.
959-104 D 959 Description: Motor failed to restart.
959-105 D 959 Description: The drive did not become ready.
959-106 D 959 Description: Electronics card failure.
959-108 D 959 Description: Bus failure.
959-110 D 959 Description: The media format is corrupted.
959-112 D 959 Description: Diagnostic failure.
959-114 D 959 Description: Non-recoverable hardware error.
959-116 D Description: A protocol error was
detected.
Action: Check the levels of the device,
adapter, diagnostic and application
software, and ensure they are all
compatible. If you do not find a problem,
call your support person.
959-117 D 959 Description: Write protect error.
959-118 D 959 Description: SCSI command timeout.
959-120 D 959 Description: SCSI busy/command error.
959-122 D 959 Description: SCSI reservation conflict error.
959-124 D 959 Description: SCSI check condition error.
959-126 D 959 Description: Software error caused by
hardware failure.
959-128 G 959 Description: Error log analysis
indicates hardware failure.
959-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 959 B88 software
959-130 G 959 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
959-134 D B88 Description: The adapter failed to configure.software
959-135 D 959 Description: The device failed to configure.B88 software
959-136 D 959 Description: The certify operation failed.
959-137 D 959 Description: Unit attention condition
has occurred on the Send Diagnostic command.
960-102 D 960 Description: An unrecoverable media error.
960-104 D 960 Description: The motor failed to restart.
960-105 D 960 Description: The drive did not become ready.
960-106 D 960 Description: The electronics card test failed.
960-108 D 960 Description: The bus test failed.
960-110 D 960 Description: The media format is corrupted.
960-112 D 960 Description: The diagnostic test failed.
960-114 D 960 Description: An unrecoverable hardware error.
960-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
960-117 D 960 Description: A write protect error occurred.
960-118 D 960 Description: A SCSI command time-out.
960-120 D 960 Description: A SCSI busy or command error.
960-122 D 960 Description: A SCSI reservation conflict error.
960-124 D 960 Description: A SCSI check condition error.
960-126 D 960 Description: A software error was caused
by a hardware failure.
960-128 G 960 Description: The error log analysis
indicates a hardware failure.
960-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.960 B88 software
960-130 G 960 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
960-132 D 960 Description: A disk drive hardware error occurred.
960-134 D B88 Description: The adapter failed to configure. software
960-135 D 960 Description: The device failed to configure.software
960-136 D 960 Description: The certify operation failed.
960-137 D 960 Description: Unit attention condition
has occurred on the Send Diagnostic command.
964-098 J 964 Description: Tape drive indicates an error.
964-099 J 964 Description: Tape drive not found.
964-101 D 964 Description: Timeout while attempting
to communicate with SCSI device.
964-102 D 964 Description: The SCSI device indicates busy.
964-103 D 964 Description: The SCSI device indicates
a reservation conflict.
964-104 D 964 Description: The SCSI device indicates
a check condition.
964-105 D 964 Description: An error is detected in
request sense data.
964-107 D 964 Description: Sense data from the SCSI
drive has unexpected data.
964-110 D 964 Description: The Reserve command failed.
964-111 D 964 Description: Invalid condition from the
drive after a reserve.
964-112 D 964 Description: The write protect sensor test failed.
964-113 D 964 Description: Invalid condition from
drive after a request sense.
964-114 D 964 Description: Timeout while attempting to
communicate with the SCSI device.
964-120 D 964 Description: The Inquiry command failed.
964-130 D 964 Description: The Load command failed. media
964-134 D B88 Description: The adapter failed to configure.software
964-135 D 964 Description: The Unload command failed. media
964-140 D 964 Description: The Mode Select command failed.
964-150 D 964 Description: The Test Unit Ready
command failed. media
964-160 D 964 Description: The Send Diagnostic
command failed. media
964-161 D 964 Description: Invalid condition from the
drive after a reserve. B88
964-163 D 964 Description: Invalid condition from the
drive after a request sense. B88
964-164 D 964 Description: Timeout while attempting
to communicate with the SCSI device. B88
964-165 D 964 Description: Write, Read and Compare Test failed.
964-166 D 964 Description: Unable to configure the device.software
964-167 D 964 Description: An unexpected SCSI error occurred.
964-168 D 964 Description: The adapter failed to configure. software
964-169 D 964 Description: The send diagnostic command failed.media
964-170 D 964 Description: The Read, Write and Compare test failed.media
964-180 D 964 Description: The Load command failed. media
964-185 D 964 Description: The Unload command failed. media
964-190 D 964 Description: The Mode Select command failed.
964-200 D 964 Description: The Test Unit Ready command failed. media
964-201 G 964 Description: Error diagnosed from error log analysis.
964-210 D 964 Description: The device configuration failed. B88
964-211 D 964 Description: The device open failed. B88
964-220 D 964 Description: The Release command failed.
964-230 D 964 Description: The Request Sense command failed.
964-240 D 964 Description: The Openx command failed.
964-260 D 964 Description: The device configuration
964-261 D 964 Description: The device open failed.
964-300 D 964 Description: The device configuration failed. software
964-310 D B88 Description: SCSI adapter configuration failed.software
964-320 G 964 Description: Error log analysis
indicates a failure. media
964-411 D 964 Description: A reservation conflict
to occurred. software
964-423
964-511 D 964 Description: The drive returned bad or
to non-extended sense data.
964-523
964-611 D 964 Description: An adapter or bus I/O
to error occurred. software
964-623
964-711 D 964 Description: A device timeout error
to occurred. software
964-723
966-101 D 966 Error in non-interactive tests.
966-103 D 966 The test pattern failed.
966-201 D 966 Description: Error in non-interactive tests on card
966-203 D 996 Description: The test pattern failed.
966-205 D 966 Description: Test pattern failed
966-207 D 966 Description: Test pattern failed
966-208 D 190 Description: Error in non-interactive test on card
966-209 D Description: Test pattern failed
966-211 D Test pattern failed
966-213 D Test pattern failed
966-304 D E22 Video error in interactive test
966-306 D E23 Audio error in interactive test
966-310 D E22 Video error in interactive test
966-312 D E23 Audio error in interactive test
966-400 D 152 Error in non-interactive tests
966-402 D 190 Test pattern failed
968-102 D 968 Description: An unrecoverable media error.
968-104 D 968 Description: The motor failed to restart.
968-105 D 968 Description: The drive did not become ready.
968-106 D 968 Description: The electronics card test failed.
968-108 D 968 Description: The bus test failed.
968-110 D 968 Description: The media format is corrupted.
968-112 D 968 Description: The diagnostic test failed.
968-114 D 968 Description: An unrecoverable hardware error.
968-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
968-117 D 968 Description: A write protect error occurred.
968-118 D 968 Description: A SCSI command time-out.
968-120 D 968 Description: A SCSI busy or command error.
968-122 D 968 Description: A SCSI reservation conflict error.
968-124 D 968 Description: A SCSI check condition error.
968-126 D 968 Description: A software error was caused
by a hardware failure.
968-128 G 968 Description: The error log analysis
indicates a hardware failure.
968-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 968 B88 software
968-130 G 968 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
968-132 D 968 Description: A disk drive hardware error occurred.
968-134 D B88 Description: The adapter failed to configure.software
968-135 D 968 Description: The device failed to configure.software
968-136 D 968 Description: The certify operation failed.
968-137 D 968 Description: Unit attention condition
has occurred on the Send Diagnostic command
969-110 G D67 Description: Residual Data Analysis
indicates memory error.
969-111 G D83 Description: Residual Data Analysis
indicates memory error.
969-120 G D68 Description: Residual Data Analysis
indicates memory error.
969-121 G D84 Description: Residual Data Analysis
indicates memory error.
.
969-130 G D69 Description: Residual Data Analysis
indicates memory error.
969-131 G D85 Description: Residual Data Analysis
indicates memory error.
969-140 G D70 Description: Residual Data Analysis
indicates memory error.
969-141 G D86 Description: Residual Data Analysis
indicates memory error.
969-150 G E11 Description: Residual Data Analysis
indicates memory error.
969-151 G E14 Description: Residual Data Analysis
indicates memory error.
969-206 G D72 Description: Residual Data Analysis
indicates memory error.
969-208 G D73 Description: Residual Data Analysis
indicates memory error.
969-210 G D71 Description: Residual Data Analysis
indicates memory error.
969-211 G D87 Description: Residual Data Analysis
indicates memory error.
969-212 G E12 Description: Residual Data Analysis
indicates memory error.
969-220 G D72 Description: Residual Data Analysis
indicates memory error.
969-221 G D88 Description: Residual Data Analysis
indicates memory error.
969-230 G D73 Description: Residual Data Analysis
indicates memory error.
969-231 G D89 Description: Residual Data Analysis
indicates memory error.
969-240 G D74 Description: Residual Data Analysis
indicates memory error.
969-241 G D90 Description: Residual Data Analysis
indicates memory error.
969-250 G E12 Description: Residual Data Analysis
indicates memory error.
969-251 G E15 Description: Residual Data Analysis
indicates memory error.
969-310 G D75 Description: Residual Data Analysis
indicates memory error.
969-311 G D91 Description: Residual Data Analysis
indicates memory error.
969-320 G D76 Description: Residual Data Analysis
indicates memory error.
969-321 G D92 Description: Residual Data Analysis
indicates memory error.
969-330 G D77 Description: Residual Data Analysis
indicates memory error.
969-331 G D93 Description: Residual Data Analysis
indicates memory error.
969-340 G D78 Description: Residual Data Analysis
indicates memory error.
969-341 G D94 Description: Residual Data Analysis
indicates memory error.
969-350 G E13 Description: Residual Data Analysis
indicates memory error.
969-351 G E16 Description: Residual Data Analysis
indicates memory error.
969-600 G Description: Residual Data Analysis
indicates memory error or unsupported memory.
Action: Examine the memory modules and
determine if they are supported types. If
the modules are supported, then replace
the appropriate memory module(s). Use
Chapter 14. "MAP 0240: Memory Problem
Resolution".
969-701 D 814 Description: NVRAM test failed
969-702 D 151 Description: Time of Day Battery test failed
969-703 D 817 Description: Time of Day Chip test failed
969-800 G 221 Description: Memory problems indicate
System Planar failure
969-900 G D01 Description: L2 cache test failed
970-098 J 970 Description: Tape drive indicates an error.
970-099 J 970 Description: Tape drive not found.
970-101 D 970 Description: Timeout while attempting to
communicate with SCSI device.
970-102 D 970 Description: The SCSI device indicates busy.
970-103 D 970 Description: The SCSI device indicates a
reservation conflict.
970-104 D 970 Description: The SCSI device indicates a
check condition.
970-105 D 970 Description: An error is detected in
request sense data.
970-107 D 970 Description: Sense data from the SCSI
drive has unexpected data.
970-110 D 970 Description: The Reserve command failed.
970-111 D 970 Description: Invalid condition from the
drive after a reserve.
970-112 D 970 Description: The write protect sensor test failed.
970-113 D 970 Description: Invalid condition from
drive after a request sense.
970-114 D 970 Description: Timeout while attempting to
communicate with the SCSI device.
970-120 D 970 Description: The Inquiry command failed.
970-130 D 970 Description: The Load command failed. media
970-134 D B88 Description: The adapter failed to configure.software
970-135 D 970 Description: The Unload command failed. media
970-140 D 970 Description: The Mode Select command failed.
970-150 D 970 Description: The Test Unit Ready command failed.media
970-160 D 970 Description: The Send Diagnostic command failed.media
970-161 D 970 Description: Invalid condition from the
drive after a reserve.
970-163 D 970 Description: Invalid condition from the
drive after a request sense.
970-164 D 970 Description: Timeout while attempting to
communicate with the SCSI device.
970-165 D 970 Description: Write, Read and Compare Test failed.
970-166 D 970 Description: Unable to configure the device.software
970-167 D 970 Description: An unexpected SCSI error occurred.
970-168 D B88 Description: The adapter failed to configure. software
970-169 D 970 Description: The send diagnostic command failed. media
970-170 D 970 Description: The Read, Write and Compare test failed.
970-180 D 970 Description: The Load command failed. media
970-185 D 970 Description: The Unload command failed. media
970-190 D 970 Description: The Mode Select command failed.
970-200 D 970 Description: The Test Unit Ready command failed. media
970-201 G 970 Description: Error diagnosed from error log analysis.
970-210 D 970 Description: The device configuration failed.
970-211 D 970 Description: The device open failed.
970-220 D 970 Description: The Release command failed.
970-230 D 970 Description: The Request Sense command failed.
970-240 D 970 Description: The Openx command failed.
970-260 D 970 Description: The device configuration failed.
970-261 D 970 Description: The device open failed.
970-300 D 970 Description: The device configuration failed.software
970-310 D B88 Description: SCSI adapter configuration failed.software
970-320 G 970 Description: Error log analysis indicates a failure. media
970-411 D 970 Description: A reservation conflict occurred.
to B88
970-423 software
970-511 D 970 Description: The drive returned bad or
to non-extended sense data.
970-523
970-611 D 970 Description: An adapter or bus I/O error occurred.
to B88
970-623 software
970-711 D 970 Description: A device timeout error occurred.
to B88
970-723 software
971-098 J 971 Description: Tape drive indicates an error.
971-099 J 971 Description: Tape drive not found. B88
971-101 D 971 Description: Timeout while attempting to
communicate with SCSI device.
971-102 D 971 Description: The SCSI device indicates busy.
971-103 D 971 Description: The SCSI device is
indicating a reservation conflict.
971-104 D 971 Description: The SCSI device indicates a
check condition.
971-105 D 971 Description: Sense data from the SCSI
device shows an error.
971-107 D 971 Description: The SCSI drive returned
unexpected sense data.
971-110 D 971 Description: The Reserve command failed.
971-111 D 971 Description: Invalid condition from the
drive after a reserve.
971-112 D 971 Description: The write protect sensor test failed.
971-113 D 971 Description: Invalid condition from the
drive after a request sense.
971-114 D 971 Description: Timeout while attempting to
communicate with the SCSI device.
971-120 D 971 Description: The Inquiry command failed.
971-130 D 971 Description: The Load command failed. media
971-135 D 971 Description: The Unload command failed. media
971-140 D 971 Description: The Mode Select command failed.
971-150 D 971 Description: The Test Unit Ready command failed.media
971-160 D 971 Description: The Send Diagnostic command failed.media
971-161 D 971 Description: Invalid condition from the
drive after a reserve.
971-163 D 971 Description: Invalid condition from the
drive after a request sense. B88
971-164 D 971 Description: Timeout while attempting to
communicate with the SCSI device. B88
971-165 D 971 Description: Write, Read and Compare Test failed.
971-166 D 971 Description: Unable to configure the device.software
971-167 D 971 Description: An unexpected SCSI error occurred.
971-168 D B88 Description: The adapter failed to configure.software
971-169 D 971 Description: The Send Diagnostic command failed.media
971-170 D 971 Description: The Read, Write and Compare test failed.media
971-180 D 971 Description: The Load command failed. media
971-185 D 971 Description: The Unload command failed. media
971-190 D 971 Description: The Mode Select command failed.
971-200 D 971 Description: The Test Unit Ready command failed.
971-201 G 971 Description: An error is diagnosed from the error log analysis.
971-210 D 971 Description: The device configuration failed.
971-211 D 971 Description: The device open test failed.
971-220 D 971 Description: The Release command failed.
971-230 D 971 Description: The Request Sense command failed.
971-240 D 971 Description: The Openx command failed.
971-260 D 971 Description: The device configuration failed.
971-261 D 971 Description: The device open test failed.
971-300 D 971 Description: The device configuration failed. software
971-310 D B88 Description: SCSI adapter configuration failed.software
971-320 G 971 Description: Error log analysis
indicates a failure.media
971-411 D 971 Description: A reservation conflict occurred.
to B88 software
971-423
971-511 D 971 Description: The drive returned bad or
to non-extended sense data.
971-523
971-611 D 971 Description: An adapter or bus I/O error
to occurred.
971-623 software
971-711 D 971 Description: A device timeout error
to occurred. B88
971-723 software
972-101 D 972 Description: Timeout while attempting to
communicate with SCSI device.
972-102 D 972 Description: The SCSI device indicates busy.
972-103 D 972 Description: The SCSI device indicates a
reservation conflict.
972-104 D 972 Description: The SCSI device indicates a
check condition.
972-105 D 972 Description: An error is detected in
request sense data.
972-107 D 972 Description: The drive has returned
unexpected sense data.
972-110 D 972 Description: The Reserve command failed.
972-111 D 972 Description: Invalid condition from the
drive after a reserve.
972-112 D 972 Description: The write protect sensor
test failed.
972-113 D 972 Description: Invalid condition from the
drive after a request sense.
972-114 D 972 Description: Timeout while attempting to
communicate with the SCSI device.
972-120 D 972 Description: The Inquiry command failed.
972-130 D 972 Description: The Load command failed. media
972-135 D 972 Description: The Unload command failed. media
972-140 D 972 Description: The Mode Select command failed.
972-150 D 972 Description: The Test Unit Ready command failed.media
972-160 D 972 Description: The Send Diagnostic command failed.media
972-161 D 972 Description: Invalid condition from the
drive after a reserve. B88
972-163 D 972 Description: Invalid condition from the
drive after a request sense. B88
972-164 D 972 Description: Timeout while attempting
communication with SCSI device. B88 276
972-165 D 972 Description: Write, Read and Compare Test failed.
972-166 D 972 Description: Unable to configure the device.software
972-167 D 972 Description: An unexpected SCSI error occurred.
972-168 D B88 Description: The adapter failed to configure.software
972-169 D 972 Description: The send diagnostic command failed.media
972-170 D 972 Description: The Read, Write and Compare test failed.media
972-180 D 972 Description: The Load command failed. media
972-185 D 972 Description: The Unload command failed. media
972-190 D 972 Description: The Mode Select command failed.
972-200 D 972 Description: The Test Unit Ready command failed.media
972-201 G 972 Description: An error is diagnosed from the error log analysis.
972-210 D 972 Description: The device configuration failed.
972-211 D 972 Description: The device open test failed.
972-220 D 972 Description: The Release command failed.
972-230 D 972 Description: The Request Sense command failed.
972-240 D 972 Description: The Openx command failed.
972-260 D 972 Description: The device configuration test failed.
972-261 D 972 Description: The device open test failed.
972-300 D 972 Description: The device configuration failed.software
972-310 D B88 Description: SCSI adapter configuration failed.software
972-320 G 972 Description: Error log analysis indicates a failure. media
972-411 D 972 Description: A reservation conflict
to occurred.
972-423 B88 software
972-511 D 972 Description: The drive returned bad or
to non-extended sense data.
972-523 B88
972-611 D 972 Description: An adapter or bus I/O error
to occurred.
972-623 B88 software
972-711 D 972 Description: A device timeout error
to occurred.
972-723 B88 software
973-110 D 973 Description: The Reserve command failed.
973-120 D 973 Description: The Inquiry command failed.
973-130 D 973 Description: The Load command failed. media
973-135 D 973 Description: The Unload command failed. media
973-140 D 973 Description: The Mode Select command failed.
973-150 D 973 Description: The Test Unit Ready command failed. media
973-160 D 973 Description: The Send Diagnostic command failed.media
973-169 D 973 Description: The send diagnostic command failed. media
973-170 D 973 Description: The Read, Write and Compare test failed.
973-180 D 973 Description: The Load command failed. media
973-185 D 973 Description: The Unload command failed. media
973-190 D 973 Description: The Mode Select command failed.
973-200 D 973 Description: The Test Unit Ready command failed.media
973-210 D 973 Description: The device configuration failed.
973-220 D 973 Description: The Release command failed.
973-230 D 973 Description: The Request Sense command failed.
973-240 D 973 Description: The Openx command failed.
973-300 D 973 Description: The device configuration failed.software
973-310 D B88 Description: SCSI adapter configuration failed.software
973-320 G 973 Description: Error log analysis
indicates a failure. media
973-411 D 973 Description: A reservation conflict
to occurred.
973-423 B88 software
973-511 D 973 Description: The drive returned bad or
to non-extended sense data.
973-523 B88
973-611 D 973 Description: An adapter or bus I/O error
to occurred.
973-623 B88 software
973-711 D 973 Description: A device timeout error
to occurred.
973-723 B88 software
974-111 D 974 Description: Unable to reserve device. B88
974-112 D 974 Description: Unable to do configuration.
974-113 D 974 Description: Unable to open the device driver. B88
974-121 D 974 Description: The CD-ROM drive indicates an error.
974-122 D 974 Description: The CD-ROM drive indicates an error.
974-123 D 974 Description: The CD-ROM drive indicates an error.
974-125 D 974 Description: The CD-ROM drive indicates an error.
974-126 D 974 Description: The CD-ROM drive indicates an error.
974-127 D 974 Description: The CD-ROM drive indicates an error.
974-128 D 974 Description: The CD-ROM drive indicates an error.
974-129 D 974 Description: The CD-ROM drive indicates an error.
974-150 D Media Description: A media error was detected.
974-151 D 974 Description: A command timeout was detected.
974-152 D 974 Description: A command reservation
conflict was detected.
974-162 D 974 Description: The CD-ROM drive indicates an error.
974-171 D 974 Description: Unable to reserve device.
974-172 D 974 Description: Unable to do configuration.
974-173 D 974 Description: Unable to open device driver.
974-175 D 974 Description: The CD-ROM drive indicates an error.
974-198 D 974 Description: Undefined error detected. B88
974-199 D 974 Description: Undefined error detected.
974-211 D 974 Description: The LED test failed.
974-281 D 974 Description: No tone during audio test.
974-301 G 974 Description: Errors found during ELA.
974-302 G 974 Description: Errors log analysis
indicates hardware failure. B88
981-102 D 981 Description: An unrecoverable media error.
981-104 D 981 Description: The motor failed to restart.
981-105 D 981 Description: The drive did not become ready.
981-106 D 981 Description: The electronics card test failed.
981-108 D 981 Description: The bus test failed.
981-110 D 981 Description: The media format is corrupted.
981-112 D 981 Description: The diagnostic test failed.
981-114 D 981 Description: An unrecoverable hardware error.
981-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
981-117 D 981 Description: A write protect error occurred.
981-118 D 981 Description: A SCSI command time-out.
981-120 D 981 Description: A SCSI busy or command error.
981-122 D 981 Description: A SCSI reservation conflict error.
981-124 D 981 Description: A SCSI check condition error.
981-126 D 981 Description: A software error was
caused by a hardware failure.
981-128 G 981 Description: The error log analysis
indicates a hardware failure.
981-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 981 B88 software
981-130 G 981 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
981-132 D 981 Description: A disk drive hardware error occurred.
981-134 D B88 Description: The adapter failed to configure.software
981-136 D 981 Description: The certify operation failed.
981-137 D 981 Description: Unit attention condition
has occurred on the Send Diagnostic command
984-102 D 984 Description: An unrecoverable media error.
984-104 D 984 Description: The motor failed to restart.
984-105 D 984 Description: The drive did not become ready.
984-106 D 984 Description: The electronics card test failed.
984-108 D 984 Description: The bus test failed.
984-110 D 984 Description: The media format is corrupted.
984-112 D 984 Description: The diagnostic test failed.
984-114 D 984 Description: An unrecoverable hardware error.
984-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
984-117 D 984 Description: A write protect error occurred.
984-118 D 984 Description: A SCSI command time-out. B88
984-120 D 984 Description: A SCSI busy or command error.
984-122 D 984 Description: A SCSI reservation conflict error.
984-124 D 984 Description: A SCSI check condition error.
984-126 D 984 Description: A software error was caused
by a hardware failure. B88
984-128 G 984 Description: The error log analysis
indicates a hardware failure.
984-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.
984-130 G 984 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
984-132 D 984 Description: A disk drive hardware error occurred.
984-134 D B88 Description: The adapter failed to configure. software
984-137 D 984 Description: Unit attention condition
has occurred on the Send Diagnostic command.
986-102 D 986 Description: An unrecoverable media error.
986-104 D 986 Description: The motor failed to restart.
986-105 D 986 Description: The drive did not become ready.
986-106 D 986 Description: The electronics card test failed.
986-108 D 986 Description: The bus test failed.
986-110 D 986 Description: The media format is corrupted.
986-112 D 986 Description: The diagnostic test failed.
986-114 D 986 Description: An unrecoverable hardware error.
986-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
986-117 D 986 Description: A write protect error occurred.
986-118 D 986 Description: A SCSI command time-out.
986-120 D 986 Description: A SCSI busy or command error.
986-122 D 986 Description: A SCSI reservation conflict error.
986-124 D 986 Description: A SCSI check condition error.
986-126 D 986 Description: A software error was caused
by a hardware failure.
986-128 G 986 Description: The error log analysis
indicates a hardware failure.
986-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. 986 B88 software
986-130 G 986 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
986-132 D 986 Description: A disk drive hardware error occurred.
986-134 D B88 Description: The adapter failed to configure. software
986-136 D 986 Description: The certify operation failed.
986-137 D 986 Description: Unit attention condition
has occurred on the Send Diagnostic command.
987-111 D 987 Description: Unable to reserve device.
987-112 D 987 Description: Unable to do configuration.
987-113 D 987 Description: Unable to open the device driver.
987-121 D 987 Description: The CD-ROM drive indicates an error.
987-122 D 987 Description: The CD-ROM drive indicates an error.
987-123 D 987 Description: The CD-ROM drive indicates an error.
987-125 D 987 Description: The CD-ROM drive indicates an error.
987-126 D 987 Description: The CD-ROM drive indicates an error.
987-127 D 987 Description: The CD-ROM drive indicates an error.
987-128 D 987 Description: The CD-ROM drive indicates an error.
987-129 D 987 Description: The CD-ROM drive indicates an error.
987-150 D Media Description: A media error was detected.
987-151 D 987 Description: A command timeout was detected.
987-152 D 987 Description: A command reservation conflict was detected.
987-162 D 987 Description: The CD-ROM drive indicates an error.
987-171 D 987 Description: Unable to reserve device.
987-172 D 987 Description: Unable to do configuration.
987-173 D 987 Description: Unable to open device driver.
987-175 D 987 Description: The CD-ROM drive indicates an error.
987-198 D 987 Description: Undefined error detected.
987-199 D 987 Description: Undefined error detected.
987-211 D 987 Description: The LED test failed.
987-281 D 987 Description: No tone during audio test.
987-301 G 987 Description: Errors found during ELA.
987-302 G 987 Description: Errors found during ELA.
989-102 D 989 Description: An unrecoverable media error
989-104 D 989 Description: The motor failed to restart.
989-105 D 989 Description: The drive did not become ready.
989-106 D 989 Description: The electronics card test failed.
989-108 D 989 Description: The bus test failed.
989-110 D 989 Description: The media format is corrupted.
989-112 D 989 Description: The diagnostic test failed.
989-114 D 989 Description: A non-recoverable hardware error
989-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
989-117 D 989 Description: A write protect error occurred.
989-118 D 989 Description: A SCSI command time-out.
989-120 D 989 Description: A SCSI busy or command error.
989-122 D 989 Description: A SCSI reservation conflict error
989-124 D 989 Description: A SCSI check condition error
989-126 D 989 Description: A software error was caused
by a hardware failure.
989-128 G 989 Description: The error log analysis
indicates a hardware failure.
989-129 G D50 Description: Error log analysis
indicates a SCSI bus problem.software
989-130 G 989 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
989-132 D 989 Description: A disk drive hardware error occurred.
989-134 D B88 Description: The adapter failed to configure.software
989-135 D 989 Description: The device failed to configure.software
989-136 D 989 Description: The certify operation failed.
989-137 D 989 Description: Unit attention condition
has occurred on the Send Diagnostic command.
990-102 D 990 Description: An unrecoverable media error.
990-104 D 990 Description: The motor failed to restart.
990-105 D 990 Description: The drive did not become ready.
990-106 D 990 Description: The electronics card test failed.
990-108 D 990 Description: The bus test failed.
990-110 D 990 Description: The media format is corrupted.
990-112 D 990 Description: The diagnostic test failed.
990-114 D 990 Description: An unrecoverable hardware error.
990-116 D Description: A protocol error.
Action: Check the levels of the device,
adapter, diagnostic software, and
application software to be sure they are
all compatible. If you do not find a
problem, call your support person.
990-117 D 990 Description: A write protect error occurred.
990-118 D 990 Description: A SCSI command time-out.
990-120 D 990 Description: A SCSI busy or command error.
990-122 D 990 Description: A SCSI reservation conflict error.
990-124 D 990 Description: A SCSI check condition error.
990-126 D 990 Description: A software error was caused
by a hardware failure.
990-128 G 990 Description: The error log analysis
indicates a hardware failure.
990-129 G D50 Description: Error log analysis
indicates a SCSI bus problem. software
990-130 G 990 Description: Error log analysis
indicates a problem reported by the disk
drive's self monitoring function.
990-132 D 990 Description: A disk drive hardware error occurred.
990-134 D B88 Description: The adapter failed to configure.software
990-136 D 990 Description: The certify operation failed.
990-137 D 990 Description: Unit attention condition
has occurred on the Send Diagnostic
B88 command. D50
991-101 D 991 Description: Timeout while attempting to
communicate with SCSI device.
991-102 D 991 Description: The SCSI device indicates busy.
991-103 D 991 Description: The SCSI device is
indicating a reservation conflict.
991-104 D 991 Description: The SCSI device indicates a
check condition.
991-105 D 991 Description: Sense data from the SCSI
device shows an error.
991-107 D 991 Description: The SCSI drive returned
unexpected sense data.
991-110 D 991 Description: The Reserve command failed.
991-111 D 991 Description: Invalid condition from the
drive after a reserve.
991-112 D 991 Description: The write protect sensor
test failed.
991-113 D 991 Description: Invalid condition from the
drive after a request sense.
991-114 D 991 Description: Timeout while attempting to
communicate with the SCSI device.
991-120 D 991 Description: The Inquiry command failed.
991-130 D 991 Description: The Load command failed. media
991-135 D 991 Description: The Unload command failed. media
991-140 D 991 Description: The Mode Select command failed.
991-150 D 991 Description: The Test Unit Ready command failed. media
991-160 D 991 Description: The Send Diagnostic command failed.media
991-161 D 991 Description: Invalid condition from the
drive after a reserve. B88
991-163 D 991 Description: Invalid condition from the
drive after a request sense. B88
991-164 D 991 Description: Timeout while attempting to
communicate with the SCSI device. B88
991-165 D 991 Description: Write, Read and Compare Test failed.
991-166 D 991 Description: The device failed to configure.software
991-167 D 991 Description: An unexpected SCSI error occurred.
991-168 D B88 Description: The adapter failed to configure.software
991-169 D 991 Description: The send diagnostic command failed.
991-170 D 991 Description: The Read, Write and Compare test failed.media
991-180 D 991 Description: The Load command failed. media
991-185 D 991 Description: The Unload command failed. media
991-190 D 991 Description: The Mode Select command failed.
991-200 D 991 Description: The Test Unit Ready command failed. media
991-201 G 991 Description: An error is diagnosed from
the error log analysis. B88
991-210 D 991 Description: The device configuration failed.
991-211 D 991 Description: The device open test failed.
991-220 D 991 Description: The Release command failed.
991-230 D 991 Description: The Request Sense command failed.
991-240 D 991 Description: The Openx command failed.
991-260 D 991 Description: The device configuration failed.
991-261 D 991 Description: The device open test failed.
991-300 D 991 Description: The device configuration failed.software
991-310 D B88 Description: SCSI adapter configuration failed.software
991-320 G 991 Description: Error log analysis
indicates a failure.media
991-411 D 991 Description: A reservation conflict
to occurred.
991-423 B88 software
991-511 D 991 Description: The drive returned bad or
to non-extended sense data.
991-523 B88
991-611 D 991 Description: An adapter or bus I/O error
to occurred.
991-623 B88 software
991-711 D 991 Description: A device timeout error
to occurred.
991-723 B88 software
994-110 D 994 Description: The Reserve command failed.
994-120 D 994 Description: The Inquiry command failed.
994-130 D 994 Description: The Load command failed. media
994-135 D 994 Description: The Unload command failed. media
994-140 D 994 Description: The Mode Select command failed.
994-150 D 994 Description: The Test Unit Ready command failed.media
994-160 D 994 Description: The Send Diagnostic command failed.media
994-169 D 994 Description: The send diagnostic command failed.media
994-170 D 994 Description: The Read, Write and Compare test failed.
994-180 D 994 Description: The Load command failed. media
994-185 D 994 Description: The Unload command failed. media
994-190 D 994 Description: The Mode Select command failed.
994-200 D 994 Description: The Test Unit Ready command failed.media
994-210 D 994 Description: The device configuration failed.
994-220 D 994 Description: The Release command failed.
994-230 D 994 Description: The Request Sense command failed.
994-240 D 994 Description: The Openx command failed.
994-300 D 994 Description: The device configuration failed.software
994-310 D B88 Description: SCSI adapter configuration failed.software
994-320 G 994 Description: Error log analysis indicates a failure.media
994-411 D 994 Description: A reservation conflict
to occurred.
994-423 B88 software
994-511 D 994 Description: The drive returned bad or
to non-extended sense data.
994-523 B88
994-611 D 994 Description: An adapter or bus I/O error
to occurred.
994-623 B88 software
994-711 D 994 Description: A device timeout error
to B88 occurred.
994-723 software
995-110 D 995 Description: The Reserve command failed.
995-120 D 995 Description: The Inquiry command failed.
995-130 D 995 Description: The Load command failed. media
995-135 D 995 Description: The Unload command failed. media
995-140 D 995 Description: The Mode Select command failed.
995-150 D 995 Description: The Test Unit Ready command failed.media
995-160 D 995 Description: The Send Diagnostic command failed.media
995-169 D 995 Description: The send diagnostic command failed.media
995-170 D 995 Description: The Read, Write and Compare test failed.media
995-180 D 995 Description: The Load command failed. media
995-185 D 995 Description: The Unload command failed. media
995-190 D 995 Description: The Mode Select command failed.
995-200 D 995 Description: The Test Unit Ready command failed. media
995-210 D 995 Description: The device configuration failed. B88
995-220 D 995 Description: The Release command failed.
995-230 D 995 Description: The Request Sense command failed.
995-240 D 995 Description: The Openx command failed.
995-300 D 995 Description: The device configuration failed.software
995-310 D B88 Description: SCSI adapter configuration failed.software
995-320 G 995 Description: Error log analysis indicates a failure.media
995-411 D 995 Description: A reservation conflict
to occurred.
995-423 B88 software
995-511 D 995 Description: The drive returned bad or
to non-extended sense data.
995-523 B88
995-611 D 995 Description: An adapter or bus I/O error
to occurred.
995-623 B88 software
995-711 D 995 Description: A device timeout error
to occurred.
995-723 B88 software
998-110 D 998 Description: The Reserve command failed.
998-120 D 998 Description: The Inquiry command failed.
998-130 D 998 Description: The Load command failed. media
998-135 D 998 Description: The Unload command failed. media
998-140 D 998 Description: The Mode Select command failed.
998-150 D 998 Description: The Test Unit Ready command failed.media
998-160 D 998 Description: The Send Diagnostic command failed.media
998-169 D 998 Description: The send diagnostic command failed.media
998-170 D 998 Description: The Read, Write and Compare test failed.media
998-180 D 998 Description: The Load command failed. media
998-185 D 998 Description: The Unload command failed. media
998-190 D 998 Description: The Mode Select command failed.
998-200 D 998 Description: The Test Unit Ready command failed.media
998-210 D 998 Description: The device configuration failed.
998-220 D 998 Description: The Release command failed.
998-230 D 998 Description: The Request Sense command failed.
998-240 D 995 Description: The Openx command failed.
998-300 D 995 Description: The device configuration failed.software
998-310 D B88 Description: SCSI adapter configuration failed.software
998-320 G 995 Description: Error log analysis indicates a failure.media
998-411 D 998 Description: A reservation conflict
to occurred.
998-423 B88 software
998-511 D 998 Description: The drive returned bad or
to non-extended sense data.
998-523 B88
998-611 D 998 Description: An adapter or bus I/O error
to occurred.
998-623 B88 software
998-711 D 998 Description: A device timeout error
to occurred.
998-723 B88 software
999-xxx D 999 Description: A 7137 or 3514 disk array series
subsystem problem is indicated.
Action: Use 7137 or 3514 documentation.
9CC-1xx G Description: I/O Error on PCI bus.
Note: xx represents the last 2 digits of
the SRN.
9CC-xxx G xxx Description: I/O Bus Data, Address
Parity Error, or Time-out error.
Note: xxx represents the last 3 digits of
the SRN.
xxxxxxxx G none Description: Refer to the Error Code to
FRU Index in the system unit's service
guide.
Action: Use the "Error Code to FRU Index"
in the service guide.
Common Error Codes
E1F1 on LED front of the box
Likely that there was one of three things that could be causing he problem...
1) There is media loaded that contains a faulty BLV
2) The bootlist does contain the device that contains a BLV
3) The BLV is corrupt and will have to be rebuilt
4) Hardware failure on the correct boot device
Machine boots up with a 4b2b2405
This error code is a service processor error code dictating that there
is a problem with the wire test that occurs at IPL with the
500Mhz 2-way proc. Call IBM SERV.
f1e
Additional Information on where to check first.
The PowerPC 604e processor has 32KB of instruction and data cache plus an additional
1MB of L2 cache to provide even greater power.
The cache is on the 604e proc
I would try the instruction and data cache
The proc or the removable cache that is on the proc There is a fixed 32kb cache
and then a removable (1mb old) 2mb cache chip