                                      DEBUG


This tutorial is made to present an overview of the DEBUG.COM program for the
IBM PC. This utility can be extremely useful, when used correctly. It is
almost a must for Assembler Language programmers, and can also provide an
insight into the operation of the machine at the bit level. It has several
nice features, including the ability to display and change any of the
registers in the IBMPC, start and stop program execution at any time, change
the program, and look at diskettes, sector by sector. DEBUG works at the
machine code level, but it does also have the ability to disassemble machine
code, and (at dos 2.0), assemble instructions directly into machine code.

The procedure for starting DEBUG and command syntax will not be covered
here, as they are well documented in the DOS manual. What we will do is show
some examples of the various commands and the response which is expected. Note
that the segment registers will probably not be exactly what is shown. This is
normal, and should be expected.

For the examples, I will be using the demo program CLOCK.COM in the XA4
database. For those of you with the IBM assembler (MASM), the source can be
down loaded. If you do not have the assembler, or have another assembler, the
file CLOCK.HEX has been up loaded. It can be converted to a .COM file  using
any of the existing HEX conversion programs on the SIG. See the file CLOCK.DOC
for more information.



                                STARTING DEBUG

There are two ways to start DEBUG with a file.  Both ways produce the same
results, and either can be used.

     In the Command Line:  A>debug clock.com <ENTER>

     Separate from the command line:  A>debug <ENTER>
                                      -n clock.com
                                      -l

With either method, you will get the DEBUG prompt of a hyphen (-). DEBUG
has loaded your program and is ready to run. The description of each
instruction will assume this as a starting point, unless otherwise mentioned.
If at any time you get different results, check your procedure carefully. If
it is correct, please leave me a message. I have tried to check everything,
but I have been known to make a mistake or two (anyway).

If you do have problems, you can enter the command Q (Quit) any time you have
the DEBUG prompt (-). This should return you to the DOS prompt.
                                
                                
                                RUNNING DEBUG

                               DISPLAY COMMANDS


                               Register command

The first thing we should look at are the registers, using the R command. If 
you type in an R with no parameters, the registers should be displayed as so:

AX=0000  BX=0000  CX=0446  DX=0000  SP=FFFE  BP=0000  SI=0000  DI=0000
DS=6897  ES=6897  SS=6897  CS=6897  IP=0100   NV UP DI PL NZ NA PE NC
6897:0100 E96B01        JMP     026E

CX contains the length of the file (0446h or 1094d). If the file were larger
than 64K, BX would contain the high order of the size. This is very important
to remember when using the Write command, as this is the size of the file to
be written. Remember, once the file is in memory, DEBUG has no idea how large
the file is, or if you may have added to it. The amount of data to be written
will be taken from the BX and CX registers.

If we want to change one of the registers, we enter R and the register name.
Let's place 1234 (hexadecimal) in the AX register:
     
     -R AX          R and AX register
     AX 0000        Debug responds with register and contents
     : 1234         : is the prompt for entering new contents. We respond 1234
     -              Debug is waiting for the next command.

     Now if we display the registers, we see the following:

AX=1234  BX=0000  CX=0446  DX=0000  SP=FFFE  BP=0000  SI=0000  DI=0000
DS=6897  ES=6897  SS=6897  CS=6897  IP=0100   NV UP DI PL NZ NA PE NC
6897:0100 E96B01        JMP     026E

Note that nothing has changed, with the exception of the AX register.The new
value has been placed in it, as we requested. One note. The Register command
can only be used for 16 bit registers (AX, BX, etc.). It cannot change the 8
bit registers (AH, AL, BH, etc.). To change just AH, for instance, you must
enter the the data in the AX register, with your new AH and the old AL values.


                                 Dump command

One of the other main features of DEBUG is the ability to display areas of
storage. Unless you are real good at reading 8088 machine language, the Dump
command is mostly used to display data (text, flags, etc.). To display code,
the Unassemble command below is a better choice. If we enter the Dump command
at this time, DEBUG will default to the start of the program. It uses the DS
register as it's default, and, since this is a .COM file, begins at DS:0100.
It will by default display 80h (128d) bytes of data, or the length you specify.
The next execution of the Dump command will display the following 80h  bytes,
and so on. For example, the first execution of D will display DS:0100 for 80h
bytes, the next one DS:0180 for 80h bytes, etc. Of course, absolute segment
and segment register overrides can be used, but only hex numbers can be used
for the offset. That is, D DS:BX is invalid.

With our program loaded, if we enter the Dump command, we will see this:

6897:0100  E9 6B 01 43 4C 4F 43 4B-2E 41 53 4D 43 6F 70 79   ik.CLOCK.ASMCopy
6897:0110  72 69 67 68 74 20 28 43-29 20 31 39 38 33 4A 65   right (C) 1983Je
6897:0120  72 72 79 20 44 2E 20 53-74 75 63 6B 6C 65 50 75   rry D. StucklePu
6897:0130  62 6C 69 63 20 64 6F 6D-61 69 6E 20 73 6F 66 74   blic domain soft
6897:0140  77 61 72 65 00 00 00 00-00 00 00 00 00 00 00 00   ware............
6897:0150  00 00 00 00 00 00 00 00-00 24 00 00 00 00 00 00   .........$......
6897:0160  00 00 00 00 00 00 00 00-00 00 00 00 00 00 00 00   ................
6897:0170  00 00 00 00 00 00 00 00-00 00 00 00 44 4F 53 20   ............DOS

Notice that the output from the Dump command is divided into three parts. On
the left, we have the address of the first byte on the line. This is in the
format Segment:Offset.

Next comes the hex data at that location. Debug will always start the second
line at a 16 byte boundary; that is, if you entered D 109, you would get 7
bytes of information on the first line (109-10F), and the second line would
start at 110. The last line of data would have the remaining 9 bytes of data,
so 80h bytes are still displayed.

The third area is the ASCII representation of the data. Only the standard
ASCII character set is displayed. Special characters for the IBMPC are not
displayed; rather periods (.) are shown in their place. This makes searching
for plain text much easier to do.

Dump can be used to display up to 64K bytes of data, with one restriction:
It cannot cross a segment boundary. That is, D 0100 l f000 is valid (display
DS:0100 to DS:F0FF), but D 9000 l 8000 is not (8000h +9000h = 11000h and
crosses a segment boundary).

Since 64K is 10000h and cannot fit into four hex characters, Dump uses 0000 to
indicate 64K. To display a complete segment, enter D 0 l 0. This will display
the total 64K segment.

If, at any time you want to suspend the display of data, Cntl-NumLock works
as usual. If you want to terminate the display, Cntl-Break will stop it and
return you to the DEBUG prompt.



                                    Search

Search is used to find the occurrence of a specific byte or series of bytes
within a segment. The address parameters are the same as for the Dump command,
so we will not duplicate them here. However, we also need the data to be
searched for. This data can be entered as either hexadecimal or character
data. Hexadecimal data is entered as bytes, with a space or a comma as the
separator. Character data is enclosed by single or double quotes. Hex and
character data can be mixed in the same request,  i.e. S 0 l 100 12 34 'abc'
56 is valid, and requests a search from DS:0000 through DS:00FF for the
sequence of 12h 34h a b c 56h, in that order. Upper case characters are
different than lower case characters, and a match will not be found if the
case does not match. For instance,'ABC' is not the same as 'abc' or 'Abc' or
any  other combination of upper and lower case characters.  However, 'ABC' is
identical to "ABC", since the single and double quotes are separators only.

An example is looking for the string 'Sat'. Here's what would happen:

     -S 0 l 0 'Sat'
     6897:0235
     -
Again, the actual segment would be different in your system, but the offset
should be the same. If we then displayed the data, we would find the string
'Saturday' at this location. We could also search on 'turda', or any other
combination of characters in the string. If we wanted to find every place we
did an Int 21h (machine code for Int is CD), we would do the following:

     -S 0 l 0 cd 21
     6897:0050
     6897:0274
     6897:027F
     6897:028B
     6897:02AD
     6897:02B4
     6897:0332
     6897:0345
     6897:034C
     6897:043A
     6897:0467
     6897:047A
     6897:0513
     6897:0526
     6897:0537
     6897:0544
     -

DEBUG found the hex data CD 21 at the above locations. This does not mean that
all these addresses are INT 21's, only that that data was there. It could (and
most likely is) an instruction, but it could also be an address, the last part
of a JMP instruction, etc. You will have to manually inspect the code at that
area to make sure it is an INT 21. (You don't expect the machine to do
everything, do you?).


                                Compare command

Along the same lines of Dump and Search commands, we have the Compare command.
Compare will take two blocks of memory and compare them, byte for byte. If the
two addresses do not contain the same information, both addresses are
displayed, with their respective data bytes. As an example, we will compare
DS:0100 with DS:0200 for a length of 8.

     -d 0100 l 8 0200
     6897:0100  E9  65  6897:0200
     6897:0101  6B  70  6897:0201
     6897:0102  01  74  6897:0202
     6897:0103  43  65  6897:0203
     6897:0104  4C  6D  6897:0204
     6897:0105  4F  62  6897:0205
     6897:0106  43  65  6897:0206
     6897:0107  4B  72  6897:0207

None of the eight bytes compared, so we got output for each byte. If we had
gotten a match on any of the bytes, DEBUG would have skipped that byte. If all
of the locations requested matched, DEBUG would have simply responded with
another prompt. No other message is displayed. This is useful for comparing
two blocks of data from a file, or a program with the BIOS ROM. Otherwise, I
have not found a great amount of use for it.



                              Unassemble command

For debugging, one of the main commands you will use is the Unassemble
command. This command will take machine code and convert it to instructions.
Addressing is the same as for previous commands with one exception: Since we
are now working with code (the previous commands are mainly for data), the
default register is the CS register. In a .COM program, this makes very little
difference, unless  you reset the DS register yourself. However, in a  .EXE
file, it can make a lot of difference, as the CS and DS registers are set to
different values.

Unassemble data can lead to some interesting results. For instance, in our
example, CS:IP is set to 6897:0100. If we look at the program, we see a JMP as
the first instruction, followed by data. If we just enter U, we will start at
CS:IP (6897:0100) and start unassembling data. What we will get is a good
instruction, followed by more or less nonsense. For instance:

     -U
     6897:0100 E96B01        JMP     026E
     6897:0103 43            INC     BX
     6897:0104 4C            DEC     SP
     6897:0105 4F            DEC     DI
     6897:0106 43            INC     BX
     6897:0107 4B            DEC     BX

And so on, through 6897:011D. We know the INC BX, DEC SP, etc. are not valid
instructions, but DEBUG doesn't, so we do have to look at the code. After
working with DEBUG a little, you will be able to spot code versus data with
the Unassemble  command. For now, suffice to say that the first instruction
will take us to CS:026E and we can start from there.

If we Unassemble CS:026E, we will find something which looks a little more
like what we expect.  We get:

     -U 26E
     6897:026E 8D167802      LEA     DX,[0278]
     6897:0272 B409          MOV     AH,09
     6897:0274 CD21          INT     21
     6897:0276 EB05          JMP     027D
     6897:0278 1B5B32        SBB     BX,[BP+DI+32]
     6897:027B 4A            DEC     DX
     6897:027C 24B4          AND     AL,B4
     6897:027E 30CD          XOR     CH,CL
     6897:0280 213C          AND     [SI],DI
     6897:0282 027D0A        ADD     BH,[DI+0A]
     6897:0285 8D167C01      LEA     DX,[017C]
     6897:0289 B409          MOV     AH,09
     6897:028B CD21          INT     21
     6897:028D CD20          INT     20

The first few instructions look fine. But, after the JMP 027D, things start to
look a little funny. Also, note that there is no instruction starting at 027D.  
We have instructions at 027C and 027E, but not 027D.  This is again because
DEBUG doesn't know data from instructions. At 027C, we should (and do) have
the end of our data. But, this also translates into a valid AND instruction,
so DEBUG will treat it as such. If we wanted the actual instruction at 027D,
we could enter U 027D and get it,  but from here,  we don't know what it is.
What I'm trying to say is, DEBUG will do what ever you tell it. If you tell it
to Unassemble data, it will do so to the best of its ability. So, you have to
make sure you have instructions where you think you do.


                              DATA ENTRY COMMANDS

                                     Enter

The Enter command is used to place bytes of data in memory. It has two modes:
Display/Modify and Replace. The difference is in where the data is specified
- in the Enter command itself, or after the prompt.

If you enter E address alone, you are in display/modify mode. DEBUG will
prompt you one byte at a time, displaying the current byte followed by a
period. At this time, you have the option of entering one or two hexadecimal
characters. If you hit the space bar, DEBUG will not modify the current byte,
but go on to the next byte of data. If you go too far, the hyphen (-) will
back up one byte each time it is pressed.

     E 103
     6897:0103  43.41   4C.42   4F.43   43.     4B.45
     6897:0108  2E.46   41.40   53.-
     6897:0109  40.47   53.

In this example, we entered E 103. DEBUG responded with the address and the
information at that byte (43). We entered the 41 and DEBUG automatically
showed the next byte of data (4C). Again, we entered 42, debug came back. The
next byte was 4F, we changed it to 43. At 106, 43 was fine with us, so we just
hit the space bar. DEBUG did not change the data, and went on to the following
bytes. After entering 40 at location 109, we found we had entered a bad value.
The hyphen key was pressed, and DEBUG backed up one byte, displaying the
address and current contents. Note that it has changed from the original
value (41) to the value we typed in (40). We then type in the correct value
and terminate by pressing the ENTER key.

As you can see, this can be very awkward, especially where large amounts of
data are concerned. Also, if you need ASCII data, you have to look up each
character and enter its hex value. Not easy, to be sure. That's where the
Replace mode of operation comes in handy. Where the Display/Modify mode is
handy for changing a few bytes at various offsets, the Replace mode is for
changing several bytes of information at one time. Data can be entered in
hexadecimal or character format, and multiple bytes can be entered at one
time without waiting for the prompt. If you wanted to store the characters
'My name' followed by a hexadecimal 00 starting at location 103, you would
enter:

     E 103 'My name' 0

As in the Search command, data can be entered in character (in  quotes) or
hexadecimal forms and can be mixed in the same command. This is the most
useful way of entering large amounts of data into memory.


                                     Fill

The Fill command is useful for storing a lot of data of the same data. It
differs from the Enter command in that the list will be repeated until the
requested amount of memory is filled. If the list is longer than the amount of
memory to be filled, the extra items are ignored. Like the Enter command, it
will take hexadecimal or character data. Unlike the Enter command, though,
large amounts of data can be stored without specifying every character. As an
example, to clear 32K (8000h) of memory to 00h, you only need to enter:

     F 0 L 8000 0

Which translates into Fill, starting at DS:0000 for a Length of 32K (8000)
with 00h. If the data were entered as '1234', the memory would be filled with
the repeating string '123412341234', etc. Usually, it is better to enter small
amounts of data with the Enter command, because an error in the length
parameter of the Fill command can destroy a lot of work. The Enter command,
however, will only change the number of bytes actually entered, minimizing the
effects of a parameter error.


                                     Move

The Move command does just what it says - it moves data around inside the
machine. It takes bytes from with the starting address and moves it to the
ending address. If you need to add an instruction into a program, it can be
used to make room for the instruction. Beware, though. Any data or labels
referenced after the move will not be in the same place. Move can be used to
save a part of the program in free memory while you play with the program, and
restore it at any time. It can also be used to copy ROM BIOS into memory,
where it can be written to a file or played with to your heart's content. You
can then change things around in BIOS without having to worry about
programming a ROM.

     M 100 L 200 ES:100

This will move the data from DS:0100 to DS:02FF (Length 200) to the address
pointed to by ES:0100. Later, if we want to restore the data, we can say:

     M ES:100 L 200 100

which will move the data back to its starting point. Unless the data has been
changed while at the temporary location (ES:0100), we will restore the data to
its original state.

                                   Assemble

I purposely left the Assemble command to the end, as it is the most complex of
the data entry commands. It will take the instructions in the assembler
language and convert them to machine code directly. Some of the things it
can't do, however, are: reference labels, set equates, use macros, or anything
else which cannot be translated to a value. Data locations have to be
referenced by the physical memory address, segment registers, if different
from the defaults, must be specified, and RET instructions must specify the
type (NEAR or FAR) of return to be used. Also, if an instruction references
data but not registers (i.e. Mov [278],5), the Byte ptr or Word ptr overrides
must be specified. One other restriction: To tell DEBUG the difference between
moving 1234h into AX and moving the data from location 1234 into AX, the
latter is coded as MovAX,[1234], where the brackets indicate the reference is
an addressed location. The differences between MASM and DEBUG are as follows:

     MASM                DEBUG                    Comments

     Mov  AX,1234        Mov  AX,1234             Place 1234 into AX
     Mov  AX,L1234       Mov  AX,[1234]           Contents of add. 1234 to AX
     Mov  AX,CS:1234     CS:Mov AX,[1234]         Move from offset of CS.
     Movs Byte ptr ...   Movesb                   Move byte string
     Movs Word ptr ...   Movsw                    Move word string
     Ret                 Ret                      Near return
     Ret                 Retf                     Far return

Also, Jmp instructions will be assembled automatically to Short, Near, or Far
Jmps. However, the Near and Far operands can be used to override the
displace ment if you do need them. Let's try a very simple routine to clear
the screen.

     -A 100
     6897:0100 mov ax,600
     6897:0103 mov cx,0
     6897:0106 mov dx,184f
     6897:0109 mov bh,07
     6897:010B int 10
     6897:010D int 20
     6897:010F
     -

We are using BIOS interrupt 10h, which is the video interrupt. (If you would
like more information on the interrupt, there is a very good description in
the Technical Reference Manual.) We need to call BIOS with AX=600, BH=7, CX=0,
and DX=184Fh. First we had to load the registers, which we did at in the first
four instructions. The statement at offset 6897:010B actually called BIOS. The
INT 20 at offset 010D is for safety only. We really don't need it, but with it
in, the program will stop automatically. Without the INT 20, and if we did not
stop, DEBUG would try and execute whatever occurs at 010F. If this happens to
be a valid program (unlikely), we would just execute the program. Usually,
though, we will find it to be invalid, and will probably hang the system,
requiring a cntl-alt-del (maybe) or a power-off and on again (usually). So, be
careful and double check your work!

Now, we need to execute the program. To do this, enter the G command, a G
followed by the enter key. If you have entered the program correctly, the
screen will clear and you will get a message "Program terminated normally".
(More on the Go command later).

Again, I cannot stress the importance of checking your work when using the
Assemble command. The commands may assemble correctly, but cause a lot of
problems. This is especially important for the Jmp and Call commands; since
they cause an interruption in the flow of the program, they can cause the
program to jump into the middle of an instruction, causing VERY unpredictable
results.


                                 I/O commands

                                     Name

The Name command has just one purpose - specifying the name of a file which
DEBUG is going to Load or Write. It does nothing to change memory or execute a
program, but does prepare a file control block for DEBUG to work with. If you
are going to load a program, you can specify any parameters on the same line,
just like in DOS. One difference is, the extension MUST be specified. The
default is no extension. DEBUG will load or write any file, but the full file
name must be entered.

     -n chkdsk.com /f

This statement prepares DEBUG for loading the program CHKDSK.COM passing the
/f switch to the program.  When the Load (see below) command is  executed,
DEBUG will load CHKDSK.COM and set up the parameter list (/f) in the program's
input area.


                                     Load

The Load command has two formats. The first one will load a program which has
been specified by the Name command into storage, set the various registers,
and prepare for execution. Any program parameters in the Name command will be
set into the Program Segment Prefix, and the program will be ready to run. If
the file is a .HEX file, it is assumed to have valid  hexadecimal characters
representing memory values, two hexadecimal characters per byte. Files are
loaded starting at CS:0100 or at the address specified in the command. For
.COM, .HEX and .EXE files, the program will be loaded, the registers set, and
CS:IP set to the first instruction in the  program. For other files, the
registers are undetermined, but basically, the segment registers are set to
the segment of the PSP (100h bytes before the code is actually loaded), and
BX and CX are set to the file length. Other registers are undetermined.

     -n clock.com
     -l

This sequence will load clock.com into memory, set IP to the entry point of
0100, and CX will contain 0446, the hexadecimal size of the file. The program
is now ready to run.

The second form of the Load command does not use the Name command. It is used
to load absolute sectors from the disk (hard or soft) into memory. The sector
count starts with the first sector of track 0 and continuing to the end of the
track. The next sector is track 0, second side (if double sided), and
continues to the end of that sector. Then, back to the first side, track 1,
and so on, until the end of the disk.  Up to 80h (128d) sectors can be loaded
at one time. To use, you must specify starting address, drive (0=A, 1=B,
etc.), starting sector, and number of sectors to load.

     -l 100 0 10 20

This instruction tells DEBUG to load, starting at DS:0100, from drive A,
sector 10h for 20h sectors. DEBUG can sometimes be used this way to recover
part of the information on a damaged sector. If you get an error, check the
memory location for that data. Often times, part of the data has been
transferred before the error occurs and the remainder (especially for text
files) can be manually entered. Also, repetitive retrys will sometimes get the
information into memory. This can then be rewritten on the same diskette (see
the Write command below), or copied to the same sector on another diskette.
In this way, the data on a damaged disk can sometimes be recovered.


                                     Write

The write command is very similar to the Load command. Both have two modes of
operation, and both will operate on files or absolute sectors. As you have
probably guessed, the Write command is the opposite of the Load command. Since
all the parameters are the same, we will not cover the syntax in detail.
However, one thing worth mentioning: When using the file mode of the Write
command, the amount of data to be written is specified in BX and CX, with BX
containing the high-order file size. The start address can be specified or is
defaulted to CS:0100. Also, files with an extension of .EXE or .HEX cannot be
written out, and error message to that effect will be displayed. If you  do
need to change a .EXE or .HEX file, simply rename and load  it, make your
changes, save it and name it back to its original filename.


                                   Input

The Input command can be used to read a byte of data from any of the I/O ports
in the PC. The port address can be either a one or two byte  address. DEBUG
will read the port, and display the contents.

     -i 3fd
     7D
     -

This is the Line input port for the first Asynchronous adapter. Your data may
be different, as it depends on the current status of the port. It indicates
the data in the register at the time it was read was 7Dh. Depending on the
port, this data may change, as the ports are not controlled by the PC.


                                    Output

As you can probably guess, the Output command is the reverse of the Input
command. You can use the Output command to send a single byte of data to a
port. Note that certain ports can cause the system to hang (especially those
dealing with system interrupts and the keyboard), so be careful with what you
send where!

     -o 3fc 1
     -

Port 3FCh is the modem control register for the first asynchronous port.
Sending a 01h to this port turns on the DTR (Data Terminal Ready) bit. A 00h
will turn all the bits off. If you have a modem which indicates this bit, you
can watch the light flash as you turn the bit on and off.


                              EXECUTION COMMANDS

                                      Go

The Go command is used to start program execution. A very versatile command,
it can be used to start the execution at any point in the program, and
optionally, stop at any of ten points (breakpoints) in the program. If no
breakpoints are set (or the breakpoints are not executed), program execution
continues until termination, in which case the message "Program  terminated
normally" is sent. If a breakpoint is executed, program execution stops, the
current registers are displayed, and the DEBUG prompt is displayed. Any of the
DEBUG commands can be executed, including the Go command to continue
execution. Note that the Go command CANNOT be terminated by Cntl-break.This is
one  of the few commands which cannot be interrupted while executing.

     -g =100

The Go command without breakpoints starts program execution at the address
(in this case CS:0100) in the command. The equal sign before the address is
required. (Without the equal sign, the address is taken as a breakpoint.) If
no starting address is specified, program execution starts at CS:IP. In this
case, since no breakpoints are specified, CLOCK.COM will continue execution
until the cntl-break key is pressed and the program terminates. At this time,
you will get the message "Program terminated normally".  Note that, after the
termination message, the program should be reloaded before being executed.
Also, any memory alterations (storing data, etc.) will not be restored unless
the program is reloaded.

     -g 276 47c 528 347

This version of the control command will start the program and set breakpoints
at CS:276, CS:47C, CS:528 and CS:347. These correspond to locations in
CLOCK.COM after the screen is cleared, and the day, date and time are
displayed, respectively. The program will stop at whichever breakpoint it hits
first. Note that the second and third breakpoints will only be displayed two
times - when the program is started and at midnight. If you care to stay up
(or just change the time in the computer), and set a breakpoint at 47C, t will
stop when the program is started, and again at midnight.

Some notes about breakpoints. The execution stops just before the instruction
is executed. Setting a breakpoint at the current instruction address will not
execute any instructions. DEBUG will set the breakpoint first, then try to
execute the instruction, causing another breakpoint. Also, the breakpoints use
Interrupt 3 to stop execution. DEBUG intercepts interrupt 3 to stop the
program execution and display the registers. Finally, breakpoints are not
saved between Go commands. Any breakpoints you want will be have to be set
with each Go command.


                                     Trace

Along the same lines as Go is the Trace command. The difference is that, while
Go executes a whole block of code at one time, the Trace command executes
instructions one at a time, displaying the registers after each instruction.
Like the Go instruction, execution can be started at any address. The start
address again must be preceeded by an equal sign. However, the Trace command
also has a parameter to indicate how many instructions are to be executed.

     -t =100 5

This Trace command will start at CS:100 and execute five instructions. Without
the address, execution will start at the current CS:IP value and continue for
five instructions. T alone will execute one instruction.

When using Trace to follow a program, it is best to go around calls to DOS and
interrupts, as some of the routines involved can be lengthy. Also, DOS cannot
be Traced, and doing so has a tendency to hang the system. Therefore, Trace 
to the call or interrupt and Go to the next address after the call or
interrupt.


                              ARITHMETIC COMMANDS

                                 Hexarithmetic

The Hexarithmetic command is handy for adding and subtracting hexadecimal
numbers. It has just two parameters - the two numbers to be added and
subtracted. DEBUG's response is the sum and difference of the numbers.
The numbers can be one to four hexadecimal digits long. The addition and
subtraction are unsigned, and no carry or borrow is shown beyond the fourth
(high order) digit.

     -h 5 6
     000B FFFF
     -h 5678 1234
     68AC 4444
     -

In the first example, we are adding 0005 and 0006.   The sum  is  000B,  the
difference is -1. However, since there is no carry,  we get FFFF.   In  the
second example, the sum of 5678 and 1234 is 68AC, and the difference is 4444.


                                    WRAPUP

If you give it a chance, DEBUG can be a very useful tool for the IBMPC. It
is almost a requirement for debugging assembler language programs, as no nice
error messages are produced at run time. DEBUG does work at the base machine
level, so you need some experience to use it effectively, but with practice,
it will be your most useful assembler language debugging tool.