Site hosted by Angelfire.com: Build your free website today!


Training Island
My HomePage | Multitest Important Points | Beach Pix | Puppy Pix | Links

It is not fiction...

I'm sure you've heard of this place. It has figured prominently in numerous cinematic features by Toho studios. But in those films it is always portrayed as a desolate island, overrun by monsters. I must admit, when my pal Shu told me that Monster Island was more than just a fictional land populated by men in ill-fitting rubber costumes, I was in disbelief. He sent me some literature on the accommodations there and I was convinced.

Safety

Although Monster Island is a real place, the proprietors do not want the location to become too well known, fearing that twould then be overrun by the greatest monster of all: man. So my trip there was planned in secret and I had to remain blindfolded during my flight. But it was all worth it, Monster Island was the best vacation I've ever had. Being able to walk up to a 20 foot high bug was just about the coolest thing in the world. I thought the giant ape and other "Monsters" on the island would be in cages, or inaccessible, but tare quite friendly and accessible.

TRAINING INSTITUTE(TI)

My Training Institute

This homepage is the refined gained knowledge at Texas Instruments for 9 years
Thanks for dropping by.!!!!!
  • Flex Contactor Pusher Why-why
    MULTITEST CONTROL PROGRAMS

  • EPC HEAT INITIALIZATION..........CP20, RB00, ST00, TM+100
  • TM VALUE FOR PLCC................CP36, ST08, TM5...10
  • TM VALUE FOR PDIP................CP36, ST08, TM20
  • TM VALUE FOR ALL PACKAGES........CP36, ST12, TM1
  • TM VALUE FOR ALL PACKAGES........CP36, ST40, TM1
  • SAVE RTP TO BPM..................CP37, RB00
  • DELETE RTP IN BPM................CP37, RB>00
  • RUN HANDLER COMPONENTS...........CP38
  • SAVE RTP TO CSRAM................CP39, RB00
  • DELETE RTP IN CSRAM..............CP39, RB>00
  • NOT ON HSM TESTERS...............CP42(1-OF-16-SIGNAL)
  • ON HSM TESTERS...................CP42(BINARY/BCD MODE)
  • ENTER HANDLER ID.................CP44, RB(WX), ST(YZ) (NOTE:WXZ=HANDLER NO, EX. 014 FOR MT14...Y=0 FOR NO AUTO I/O, Y=5 WITH AUTO I/O
  • SERVICE POSITION.................CP48
  • DEFINE SERVICE TRACK.............CP49
  • SELECT DISPLAY LANGUAGE..........CP50
  • HANDLER CONVERSION POSITION......CP51
  • NO. OF INPUT MAG TRACKS..........CP52, RB00, TMXX
  • NO. OF OUTPUT MAG TRACKS.........CP52, RB>00, TMYY
  • DISABLE LOADING COUNT............CP53, ST00
  • SINGLE CONTACT MODE..............CP60
  • ENABLE/DISABLE SOAKTIME..........CP61
  • DEVICES STATS SINCE V3.29........CP62, RB00
  • PERFORMANCE STATS COUNTER........CP62, RB>00
  • ERROR STATS AT COLD..............CP64, RB00
  • ERROR STATS AT AMBIENT...........CP64, RB01
  • ERROR STATS AT HOT...............CP64, RB02
  • ERASE ERROR STATISTICS...........CP64, TM+100 AND START-STOP SEQUENCE
  • BIN CLASS FOR SORTED IC..........CP67, ST 0 TO 15
  • NO. OF IC'S SORTED AS "-"........CP67, ST 16 TO 19
  • TEMP AT INPUT MAG PLATE..........CP70
  • TEMP AT CONTACT SITE.............CP76
  • TEMPERATURE COMPENSATION VALUE...CP 70 TO 76, ST01
  • POWER OF HEATING/DUTY CYCLE......CP 70 TO 76, ST02
  • TEST LED BIN DISPLAY.............CP80
  • TEST SOUND GENERATOR.............CP81
  • TEST MOTOR POSITION, CP82


  • TEST TURN SHUTTLE(T/S) EJECT POSITION..... RB06, ST01
  • T/S RECEIVING POSITION.................... RB06, ST04
  • T/S REFERENCE POSITION.................... RB06, ST06
  • FEED SHUTTLE(F/S) RECEIVING POSITION...... RB07, ST01
  • F/S EJECT POSITION........................ RB07, ST04
  • F/S REFERENCE POSTION..................... RB07, ST06