3COM CORPORATION ETHERLINK 16 TP (3C507-TP) NIC Type Ethernet Transfer Rate 10Mbps Data Bus 16-bit ISA Topology Star Wiring Type Unshielded twisted pair Boot ROM Available [Image] 10BASE-T STANDARD COMPATIBILITY CONFIGURATION Setting Jumper Setting » DC signal disabled 2 J1 Pins 2 & 3 closed DC signal enabled (On receive J1 Pins 1 & 2 wires) 3 closed » Link beat enabled J2 Pins 1 & 2 closed Link beat disabled J2 Pins 2 & 3 closed » Receive threshold select normal J3 Pins 1 & 2 closed Receive threshold select low 1 J3 Pins 2 & 3 closed » Equalization disabled 2 J4 Pins 2 & 3 closed Equalization enabled 3 J4 Pins 1 & 2 closed » Transmit level select normal (± J6 Pins 1 & 2 5V) closed Transmit level select low (± J6 Pins 2 & 3 2V) closed » Cable Impedance select 100ohms J7 Pins 2 & 3 closed Cable Impedance select 150ohms J7 Pins 3 & 4 closed Cable Impedance select 75ohms J7 Pins 1 & 2 closed Note 1: Use this setting with the 3Com MultiConnect TP Module. Do not use this setting with the 3Com LinkBuilder, or the SynOptics LattisNet Model 3308. Note 2: This is the 10BASE-T standard and should be used with all 10BASE-T standard hubs. Note 3: This setting is required when using any Pre-10BASE-T SynOptics hub. DIAGNOSTIC LED(S) LED Color Status Condition L1 Yellow Blinking Data is being transmitted or received L1 Yellow Off Data is not being transmitted or received L2 Green On Twisted pair network connection is good L2 Green Blinking Twisted pair wire polarity reversed L2 Green Off Twisted pair network connection is broken Note: Reversed polarity is automatically corrected for but this may impede performance. It is suggested that reversed polarity wires be corrected to attain maximum performance.