DANPEX CORPORATION EN-2200T NIC Type Ethernet Transfer Rate 10Mbps Data Bus 16-bit ISA Topology Star Wiring Type Shielded/Unshielded twisted pair AUI transceiver via DB-15 port Boot ROM Available [Image] ACTIVITY LED Setting JP1 Enabled Closed Disabled Open Note:If the network hub has an activity LED for each line, setting this option to enabled will allow the hub LED to LINK INTEGRITY TEST Setting JP2 » Enabled Pins 1 & 2 closed Disabled Pins 2 & 3 closed Note:The link integrity test is valid only when the cable type is shielded/unshielded twisted pair. CABLE TYPE Type JP3 » Shielded/Unshielded twisted pair Pins 1 & 2 closed AUI transceiver via DB-15 port Pins 2 & 3 closed WAIT STATE Setting JP4 JP5 » 0 wait states Open Open 1 wait state Open Closed 2 wait states Closed Open INTERRUPT REQUEST IRQ JP6A JP6B JP6C JP6D JP6E JP6F JP6G 2/9 Closed Open Open Open Open Open Open » 3 Open Closed Open Open Open Open Open 4 Open Open Closed Open Open Open Open 5 Open Open Open Closed Open Open Open 10 Open Open Open Open Closed Open Open 12 Open Open Open Open Open Closed Open 15 Open Open Open Open Open Open Closed BOOT ROM Setting JP7A » Disabled Open Enabled Closed BOOT ROM ADDRESS Boot ROM Address JP7B JP7C JP7D C8000h Closed Open Closed CC000h Open Open Closed D0000h Closed Closed Open D4000h Open Closed Open I/O BASE ADDRESS I/O Address JP7E JP7F » 300h Closed Closed 320h Open Closed 340h Closed Open 360h Open Open DIAGNOSTIC LED(S) LED Status Condition LED1 Blinking Data is being transmitted LED1 Off Data is not being transmitted LED2 On Twisted pair connection is good LED2 Off Twisted pair connection is broken LED3 Blinking Data is being received LED3 Off Data is not being received LED4 On Collision detected on network LED4 Off No collisions detected on network Note:LED2 will only funtion when the cable type is twisted pair, otherwise LED2 will remain off.