POST ERROR CODES
 Error      Description                           Actions/Possible FRU's
 -----------------------------------------------------------------------------
 FIRMWARE ERROR CODES

 00010000   CPU card test error                   CPU card
 0001000A   Machine Check                         Use minimum config MAP
 0001500x   Error while erasing system firmware   CPU card
 00016000   Use with Fxx Codes
 00016010   System VPD access failure             Sys. Bd., VPD module
 00017001   CMOS error                            Battery
 00017002   CMOS data gone/not initialized        Battery
 00017003   Power interruption during boot        Update boot sequence
 00017006   Tamper evident detected or battery
 00017007   Maximum login tries                   Power on Reset
 00017008   Maximum login tries                   Power on Reset
 00017013   No power on password entered
 00017015   Tamper evident is detected-security   or Bad CMOS Battery
 00018000   Bad flash image                       CPU card
 00020000   Memory test error
 000210y0   Bad memory in slot "y" (1-8)          Bad/unsupported memory
 00031100   Keyboard in the wrong port
 00031300   Failed to register keyboard interrupt Keyboard, System Board
 00070000   Service Processor POST failure        Service Proc., Sys. Bd.
 00070001   CPU card or power supply failure
 00070006   Slow or stuck fan                     Fans, SP, System Board
 00070007   System over temperature
 00070008   Environmental condition               Use with Fxx codes
 00070009   Environmental condition               Use with Fxx codes
 00070010   Environmental condition               Use with Fxx codes
 00070011   Environmental condition               Use with Fxx codes
 00070012   Service processors fails self test    Serv. Proc., Sys. Bd.
 00070013   Bad NVRAM CRC error                   Battery, System Board
 00070014   Bad service processor firmware        Re-program firmware
 00070015   Bad service processor VPD             Serv. Proc., Sys. Bd.
 00070016   Bad processor firmware failure        Firmware update, Serv. Proc.
 00070017   Bad or low battery                    Battery, SP, Sys. Bd.
 00070018   EPOW test failure                     Serv. Proc., Sys. Bd.
 00070019   Interrupt (IRQ13) test failure        Sys. Bd., Serv. Proc
 -----------------------------------------------------------------------------
 0037cyyi   SCSI controller interface error
 0208cyyi   SCSI device/adapter error
 0210cyyi   SCSI DASD error
 0211cyyi   SCSI tape error
 0215cyyi   SCSI CDDROM error

               c=SCSI controller ID assigned in the following order:
                    1.  PCI slot 1
                    2.  PCI slot 2
                    3.  Integrated controller
                    4.  PCI slot 3
                    5.  Continues until last slot...

               Example:  SCSI card slot 2   = ID 0
                         Integrated SCSI    = ID 1
                         SCSI card slot 3   = ID 2

               Example:  Integrated SCSI    = ID 0
                         SCSI card slot 3   = ID 1

               yy=POST error status codes

               08  Invalid device number
               11  No SCSI card
               13  Command failed
               28  Reservation conflict
               29  Device not available
               43  Not enough memory
               47  Waiting for completion
               49  Sense needed
               51  Reset needed
               55  Not ready or no media
               56  Invalid (unsupported) command
               57  Write protected
               59  Media error
               60  Hardware error
               61  Unit attention
               62  Blank check
               63  Command abort
               64  Busy
               65  Media
               66  Script error
               67  Invalid address
               68  Media changed
               69  Device reset
               70  Format in progress
               71  Format corrupted
               72  Start required
               73  Device ID conflict
               74  Manual intervention
               75  Media not found
               76  In progress
               77  Media eject failed
               78  Write protect failed
               80  SCSI controller interface error
               81  SCSI controller interface error
               82  SCSI bus access error
               83  SCSI fuse bad or PTC tripped
               84  SCSI device command failed
               85  SCSI controller interface error
               86  SCSI controller interface error
               87  Short record length
               88  SCSI bus parity error
               89  SCSI device no reset
               90  Time out error
               99  SCSI controller interface error

               i=SCSI ID (0-9 or A-F)



 01291000   An error during L2 Cache test         CPU card
 0243025y   Graphics controller, DAC failure      Grpahics PCI card slot y
 -----------------------------------------------------------------------------

 20100xxx   Power Supply
 20A80xxx   Remote IPL error
 20A80000   Insufficient Information to boot      Verify IP address
 20A80001   Client IP address already used        Change IP address
 20A80002   Cannot get gateway IP address         Refer to Fxx Boot Problems
 20A80003   Cannot get server hardware address    Refer to Fxx Boot Problems
 20A80004   Bootp failed                          See Checkpoint F75
 20A80005   File transmission (tftp) failed       Check network connection
 20D00xxx   Unknown/Unrecognized device
 20D0000F   Device selftest failure, no SRN       Locate device with SMS
 20D00010   Device selftest failure
 20E00000   Power on password entry error         Wrong password entered
 20E00001   Privileged-access password entry err. Wrong password entered
 20E00002   Privileged-access password jumper is in wrong jumper position
 20E00003   Power on password must be set for Unattended Mode
 20E00004   Battery needs drained or replaced     Battery, System Board
 20E00005   EEPROM locked-Power on reset--or->    Bad System Board
 20E00008   CMOS corrupted or tampering evident   Battery, System Board
 20E00009   Invalid password entered 3 times      Power on reset, System Bd.
 20E0000A   EEPROM lock problem                   PAP jumper, System Board
 20E0000B   EEPROM write problem                  System Board
 20E0000C   EEPROM read problem                   System Board
 20E00017   Cold boot needed for password entry   Power on reset
 20EE0xxx   Informational
 20EE0003   IP parameter requires 3 delimiters    000.000.000.000
 20EE0004   Invalid IP parameter
 20EE0005   Invalid IP parameter (>255)           255.000.000.000
 20EE0006   No SCSI controllers                   Adapter, System Board
 20EE0007   Keybaord not found                    Keyboard, System Board
 20EE0008   No adapters found                     Adapter, Riser, System Bd.

 21A00xxx   SCSI disk drive                       Device, cable, controller
 21A00001   Test Unit Ready Failed (hardware)     Device, cable, controller
 21A00002   Test Unit Ready Failed-sense data     Media, device
 21A00003   Send diagnostic failed                Device
 21A00004   Send diagnostic failed-DevOfl cmd     Device
 21E00xxx   SCSI tape
 21ED0xxx   SCSI changer
 21EE0xxx   Other SCSI device
 21F00xxx   SCSI CDROM
 21F20xxx   SCSI Read/Write Optical

 25010xxx   Flash
 25010000   No diskette in drive                  Looking for firmware image
 25010001   Diskette seek error
 25010002   Diskette doesn't contain *.IMG file   Insert firmware update dskt
 25010003   Can't open OPENPROM package           System Board
 25010004   Can't find OPENPROM node              System Board
 25010006   System id's don't match               Use correct firmware dskt
 25010007   Image has bad CRC                     Replace firmware dskt
 25010008   Flash write protected-Power on reset  System Board
 25010009   Flash module not supported/recognized Use correct firmware dskt
 2501000A   Flash write protected-Power on reset  System Board
 25A0xxy0   L2 Cache - refer to 2B2xxyrr          CPU, System Board
 25A80xxx   NVRAM                                 Low Battery, Rebuild Config
 25A80000   Initialization failed
 25A80001   All NVRAM initialized
 25A80002   GE area preserved
 25A80011   Data corruption detected-NVRAM
 25A80012   Data corruption detected
 25A80100   NVRAM data validation check failed    Power On Reset
 25AA0xxx   EEPROM                                Security jumper, System Bd.
 25AA0000   Unable to unlock EEPROM
 25AA0001   Read-Recv error
 25AA0002   Read-Trans error
 25AA0003   Write-enable error
 25AA0004   Write-recv error
 25AA0005   Write-disable error
 25AA0006   Write-Trans error
 25AA0007   Unable to lock EEPROM

 -----------------------------------------------------------------------------
 25Cyyxxx   Memory                                Memory PD
 25Cyy001   DIMMS fails memory test               Memory DIMM
 25Cyy002   DIMM not supported

 yy=Memory DIMM PD bits
 -----------------------------------------------------------------------------
 PD Value    Size       Speed(nsecs)     Parity/ECC      Single/Dual
 -----------------------------------------------------------------------------
    64        8MB            60              ECC            Single
    69       16MB            60              ECC            Single
    6B       32MB            60              ECC            Single
    6D       64MB            60              ECC            Single
    6F      128MB            60              ECC            Single
------------------------------------------------------------------------------

 28030xxx   RTC (Real Time Clock)                 Reset passwords/date/time
 28030001   RTC not updating                      RTC needs initialized
 28030002   Bad date/time                         Reset date/time

 29000002   Keyboard/mouse controller failed      System Board
 29A00003   Keyboard missing                      Keyboard, System Board
 29B00004   Mouse missing                         Mouse, System Board
 -----------------------------------------------------------------------------
 2B200042   Unknown processor type
 2B2xxyrr   xx=processor type/speed          21   166Mhz 604+
                                             22   200Mhz 604+
            y=Cache information               0   Integrated cache or N/A
                                              5   512KB
                                              6   1MB
                                              7   256KB
                                              D   ICBM 1MB
 2B2xxy22   Bad processor/CPU
 2B2xxy31   Disabled due to Asymetrical MP
 -----------------------------------------------------------------------------
 2BA00xxx   Service Processor (SP)
 2BA00000   Service Processor POST failure
 2BA00001   CPU Card or power supply failure
 2BA00006   FAN error incorrectly reported        Fans, Service Proc., Sys Bd.
 2BA00007   SP reports over temperature           Fans, System Board
 2BA00008   SP reports over temperature           Fans, System Board
 2BA00009   CPU over temperature                  Fans, CPU, System Board
 2BA00010   Fast shutdown pending                 Power supply, System Board
 2BA00011   SP reports CPU failure                Power supply, System Board
 2BA00012   SP reports self-test failure          Service Proc., System Board
 2BA00013   SP reports bad NVRAM CRC              Battery, System Board
 2BA00014   SP reports bad processor firmware     Rebuild firmware
 2BA00015   SP reports bad SP VPD                 Service Proc., System Board
 2BA00016   SP reports firmware failure           Update firmware, Serv. Proc.
 2BA00017   SP reports bad/low battery            Battery, SP, System Board
 2BA00018   EPOW test failure                     Serv. Proc., System Board
 2BA00019   IRQ13 test failure                    System Board, Serv. Proc.
 2BA00020   SP reports VPD access failure         System Board, VPD module
 2BA00022   SP reports bad CRC - CMOS/NVRAM       System Board
 2BA00023   CPU card test error                   CPU card
 2BA00100   SP firmware recovery info can't be written to diskette
 2BA00101   Service Processor not installed
 2BA00102   No SP diskette in drive
 2BA00103   SP firmware diskette corrupted
 2BA00104   SP firmware diskette same level
 2BA00200   SP firmware update error              Unplug/Replug-try again
 2BA00201   SP firmware update error
 2BA00202   SP firmware update error
 2BA00203   SP firmware update error
 2BA00204   SP firmware update error
 -----------------------------------------------------------------------------
 40100005   Loss of system power detected         Power Supply
 40111002   Unknown power problem                 Power Supply, Sys Bd, SP
 40111022   High 5.0 voltage                      Power Supply, CPU card
 40111032   High 3.3 voltage                      CPU card, Power Supply
 40111042   High 2.5 voltage                      CPU card, Power Supply
 40111052   High +12 voltage                      Power Supply, Sys. Bd.
 40111062   High -12 voltage                      Power Supply, Sys. Bd.
 40111082   Low 5.0 voltage                       Power Supply, CPU card
 40111092   Low 3.3 voltage                       CPU card, Power Supply
 401110A2   Low 2.5 voltage                       CPU card, Power Supply
 401110B2   Low +12 voltage                       Power Supply, Sys. Bd.
 401110C2   Low -12 voltage                       Power Supply, Sys. Bd.

 40200001   Unknown cooling problem               Fans
 40200021   CPU temperature warning
 40200023   Critical CPU temperature warning
 40200031   I/O planar temperature warning
 40200033   Critical I/O planar temperature
 40200041   Memory temperature warning
 40200043   Critical memory temperature
 40210011   Slow fan
 40210014   Stopped fan

 40A00000   IPL ROS surveillance interval exceeded-Firmware IPL failure
 40B00000   Operating system surveillance interval exceeded
 40D00003   Unknown slow shutdown commanded       Critical cooling problem
 40D00004   Unknown fast shutdown commanded       Locked fan failure
 -----------------------------------------------------------------------------
 80001200   Bad firmware recovery diskette        Diskette
 80001300   Same firmware level already loaded
 80001400   Firmware doesn't support system
 80001500   Firmware update file corrupted
 80001600   Firmware update file not on drive     Verify drive/path/filename
 80001700   Firmware file on disk corrupted       Obtain a new file
 80001800   Valid firmware file not located       Verify drive/path/filename
 80001900   Firmware doesn't support system
 80002000   2 Flash images found
 80002100   Firmware update couldn't be loaded    Verify drive/path/filename
 80002200   Firmware update module write-protect  POR, Retry, CPU card
 80002300   Utility version not supported         POR, Retry, CPU card
 80002400   Firmware module not supported         Flash on CPU card bad
 80002500   Firmware module not supported         Flash on CPU card bad
 80002600   Firmware module write-protected       POR, Retry, CPU card
 80002700   Backup recover diskette needed        Insert diskette
 80002800   Update firmware diskette not in drive Insert diskette
 80072000   Service Processor not installed       Install Serv. Processor
 -----------------------------------------------------------------------------
 91001100   Remote IPL error, insufficient memory Defective/insufficient mem.
 91001200   Remote IPL error - incorrect IP format for client IP address
 91001300   Remote IPL error - incorrect IP format for server IP address
 91001400   Remote IPL error - incorrect IP format for gateway IP address
 91001500   Remote IPL error - incorrect IP format for netmask
 91001600   Remote IPL error - error writing to NVRAM
 91001700   Remote IPL error - ethernet adapter not found
 91001900   Remote IPL error - token-ring adapter not found
 91002000   Remote IPL error - no network adapters recognized
 91002200   Remote IPL error - ping failed

 M0CON000   System hung during POST               Go to minimum config
 M0CPU000   CPU POST failed                       CPU Card, System Board
 M0CPU001   Checkstop occurred                    CPU Card, System Board
 M0FD0000   System hung during diskette POST      System Board, Diskette Drv.
 M0GA0000   Graphics Adapter POST failed          Graphics Adapter
 M0HD0000   System hung during POST               Go to minimum config
 M0KBD000   System hung during keyboard POST      System board, Keyboard
 M0KBD001   System didn't respond to key entry    Type 101 Keyboard
 M0KBD002   System didn't respond to key entry    Type 102 Keyboard
 M0KBD003   System didn't respond to key entry    Type 106 Keyboard
 M0MC0001   Machine Check                         Go to minimum config
 M0MEM000   No good memory found                  Memory, System Board
 M0MEM001   No good memory found                  Memory, System Board
 M0MEM002   System hung during memory POST        Go to minimum config
 M0PS0000   Power failure                         Go to Power MAP
 M0SCSI00   Unable to load diagnostics            Go to minimum config
 M0SCSI01   Unable to load diagnostics            Go to minimum config
 M0SPK000   Continuous beep is heard              System Board
 M0SPK001   The system doesn't beep               Speaker, System Board
 M0BT0000   Audio error--Use Fxx Code, if none--  Go to minimum config
 M0NET000   Network error--Use Fxx Code, if none--Go to minimum config

Firmware Checkpoint Codes

F00 Manufacturing - Reserved for Parallel    port download protocol
F01 Clear the EPOW register 1. Memory modules 2. system board
F02 Determine system bus speed, set ISA advisor
F04 Set memory refresh
F05 Transfer control to Operating System ( nornmal boot )
            Action: Try to boot and run standalone diagnostics against the system. particularly 
            against the  intended boot device. If the diagnostics are successful, it may 
            be necessary to perform an  operating system specific recovery process, 
            or reinstall the operating system.
F06 Jump to set environment or check flash
F08 Run recovery block base memory, test 2k, then set stack
F09 Copy CRC verification code to RAM
F0A Turn on cache
F0B Flush cache
F0C Jump to CRC verification code in RAM
F0D Compute composite image CRc
F0E Jump back to ROM
F0F Turn off cache
F10 Check if composite image CRC is valid
F11 Good CRC - jump to composite image
F12 Bad CRC - initialize base memory, stack
F13 Bad CRC - copy uncompressed recovery block code to RAM
F14 Bad CRC - jump to code in RAM
F15 Bad CRC - turn on cache
F16 Bad CRC - copy recovery block data section to RAM
F17 Bad CRC - invalidate and flush cache, set TOC
F18 Bad CRC - branch to high level recovery control routine
F19 Initialize base memory, stack
F1A Copy uncompressed recovery block code to RAM
F1B Jump to code in RAM
F1C Turn on cache
F1D Copy recovery block data section to RAM
F1E Invalidate and flush cache, set TOC
F1F Branch to high level control routine
F20 Initialize system I/O
F21 Run a console diagnostic routine
F22 No memory found
F23 No DIMM found in socket
F24 Remove bad DIMM found from DIMM information
F25 Unsupported DIMM detected
F26 Check valid image - start
F27 Check valid image - successful
F28 Wait for interrupt
F29 Transfers information to the business audio chip
F2B Wait until sound chip has been initialized
F2C Initialize the current input/pointer device
F2D Initialize the current output
F2E Register a console driver
F30 Set up early memory allocation heap, intialize Super I/O
F31 Determine system bus speed, set ISA driver
F32 Resync to SP (Console image)
F33 Set memory refresh
F35 Jump to set environment
F40 Initialize interrupt subsystem and 8259s
F41 SP command setup
F42 SP mailbox interface
F43 get_vpd entry
F44 init_sp entry
F45 sp_recovery -> resync SP & CPU
-----------------------------------------------------------------------------
00016000 Error and the following Checkpoint Code

F46 IRQ13 stuck high  Bad System Board or Service Processor
F47 Entry to error checking routine-No system board VPD, bad CRC Bad System Board
F48 Power supply or system board problem Other 8-digit Codes possible: 00070010, 40100005
F49 Voltage problem, system board, power supply or CPU 5V high/low-bad power supply, 
        CPU card,  Other 8-digit Codes possible: 40111022, 40111082
F4A Voltage problem, system board or power supply 12V high/low - bad power supply, 
        CPU card, System Board Other 8-digit Codes possible: 40111052, 401110B2, 
        401110C2, 40111062, 00070010
F4B CPU over temperature or bad system board Other 8-digit 
        Codes possible: 40200021, 00070009
F4C start bit-map display function
F4D Bit-map file read into memory, start processing
F4E End bit-map display function
F4F IO/MEM over termperature or bad system board  8-digit Codes 
        possible: 40200031, 40200041,00070008
F50 Initialize CMOS RTC periodic interrupt
F51 System board or system over temperature, CPU card Critical 
       Temp Other 8-digit Codes possible: 40200023, 40200033, 40200043, 00070008, 00070009
F52 Bad system board (fan fail reported) Other 8-digit Codes possible: 40210011, 40210014
F53 Bad system board or Fans Other 8-digit Codes possible: 40210011, 40210014
F54 Fan fail warning
F55 Bad system board (unsupported EPOW)
F56 Voltage problem, system board, power supply or CPU 3.3V/2.5V high/low
              Other 8-digit Codes possible: 40111032, 40111092, 40111042, 401110A2
-----------------------------------------------------------------------------
F57 Bad or low battery
F58 IRQ13 test failure
F59 EPOW test failure
F5A Spurious IRQ6 interrupt (i.e. interrupt glitch)
F5B Fan failure warning
F5B Transfer control to Operating System ( service mode bootlist )
F5C Clear EPOW register failure
F5D Clear EPOW register failure
F60 Initialize keyboard/mouse controller, and password
F61 Extended memory initialization command
F62 Diskette initialization command
F64 Test of day routine
F6A SCSI initialization command
F70 Initialize debugger
F71 Start checking whether CMOS contents are valid
F72 End checking whether CMOS contents are valid
F73 Dumps contents of CMOS data area to a file
F74 Establishing Host conmnection
F75 BootP request
F77 Resync to SP (Recvoery image)
F79 Dupms contents of NVRAM data area to a file
F7A NVRAM initialization
F7B Check NVRAM validity CRC
F7C Loads contents of CMOS from file
F80 Initialize system call table
F82 Register a manager for use by the system
F88 Halt. System locked by error condition - power off
F90 Initialize VDISK file system
F91 Low-level initialize VDISK file systems
F94 Start SCSI initialization
F96 SCSI bus scan start
F97 SCSI polling interrupt
F98 SCSI device detected
F9E Real Time clock RTC initialization
F9F Exit SCSI initialization
FA0 Start resident monitor, run V:autoexec.6md-initializes various sub- systems-video, 
        keyboard/mouse, extended memory, diskette, SCSI, etc.
FA1 Enter resident monitor
FA2 Resident monitor process
FA3 Resident monitor process
FA4 Exit resident monitor
FA5 ASCII terminal initialization
FA6 ASCII terminal initialization exit
FA9 p9 driver initialization
FAA p9 driver exit
FAB Keyboard driver initialization
FAC Keyboard driver exit
FAD Mouse driver initialization
FAE Mouse driver exit
FB0 Initialize rest of file system
FB1 Diskette initialization
FB2 Diskette drive type determination
FB3 Diskette initialization complete
FC0 Check if flash ROM OK
FCA Build boot table - Networks
FCB Build boot table - DASD
FCC Build boot table - CDROM
FCD Build boot table - diskettes
FCE No operating system boot, exit normal boot sequence
FD0 Start of boot sequence
FD2 No operating system boot - ensure CMOS RTC periodic clock updates displayed
FD4 Initialize console for loading diagnostics
FD8 Exit from diagnostic - run resident monitor
FDA IRQ15
FDB Unexpected processor exception
FDC Dynamic console selection
FDD Early processor exception
FDE Alternating pattern of FDE and FDA indicates a processor exception has been detected.
FE1 Test timeout
FE2 Initialize system I/O
FE4 Initialize super I/O with default values
FE6 Set up early memory allocation heap
FE8 Initialize primary diskette drive in polled mode
FEA Try to load in recovery image from diskette
FEB F30 Verify recovery image is 
         The F40 action plan should also work valid | on the F30 Use the F30 firmware.
         F40 Firmware flash corrupted, | A C T I O N load from diskette |
         If the system will not boot up fully|and the checkpoint display reads "FEB", 
         |the firmware is partially corrupted, but |should be recoverable. 
         Make a copy of |the firmware update diskette, rename the |.img file to 
        PRECOVER.IMG and insert|this "recovery" diskette in the drive |
         when the FEB appears on the checkpoint display.
FEC Get recovery image entry point
FED Invalidate instruction cache
FEE Jump to composite image
FF0 Manufacturing - Check fo parallel port hook
FF4 Manufacturing - Start flag not received
FF5 Manufacturing - Invalid start flag received
FF6 Manufacturing - Receive character timeout
FF7 Manufacturing - CRC value mismatch
FFA Error during flash update
FFC Operating system boot - no errors reported by IPL ROS
FFD Operating system boot - non-critical errors reported by IPL ROS
FFE No boot - critical error(s) reported by IPL ROS -or- F1 key pressed


Diagnostic Information for Multiple Bus Systems
Configuration Program Indicators


500  Querying Standard I/O slot. 
501  Querying card in Slot 1. 
502  Querying card in Slot 2. 
503  Querying card in Slot 3. 
504  Querying card in Slot 4. 
505  Querying card in Slot 5. 
506  Querying card in Slot 6. 
507  Querying card in Slot 7. 
508  Querying card in Slot 8. 
510  Starting device configuration. 
511  Device configuration completed. 
512  Restoring device configuration files from media. 
513  Restoring basic operating system installation files from media. 
516  Contacting server during network boot. 
517  Mounting client remote file system during network IPL. 
518  Remote mount of the root and /usr file systems failed during network boot. 
520  Bus configuration running. 
521  /etc/init invoked cfgmgr with invalid options; /etc/init has been 
        corrupted or incorrectly modified(irrecoverable error). 
522  The configuration manager has been invoked with conflicting options 
         (irrecoverable error). 
523  The configuration manager unable to access the ODM database (irrecoverable error). 
524  The configuration managers unable to access the config.rules in the 
        ODM database (irrecoverable error). 
525  The configuration manager unable to get data from customized device  
        in the ODM database (irrecoverable) 
526  The configuration manager unable to get data from customized device 
        driver in the ODM( irrecoverable error). 
527  The configuration manager was invoked with  phase 1 flag (irrecoverable error). 
528  The configuration manager cannot find sequence rule, or no program name 
         specified in  ODM(irrecoverable) 
529  The configuration manager is unable to update ODM data (irrecoverable error). 
530  The program savebase returned an error. 
531  The configuration manager is unable to access the PdAt object class (irrecoverable error). 
532  There is not enough memory to continue (malloc failure); irrecoverable error. 
533  The configuration manager could not find a configure method for a device. 
534  The configuration manager is unable to acquire database lock (irrecoverable error). 
535  HIPPI diagnostics interface driver being configured. 
536  The configuration manager encountered more than one sequence rule (irrecoverable error). 
537  The configuration manager encountered an error when invoking 
        the program in the sequence rule. 
538  The configuration manager is going to invoke a configuration method. 
539  The configuration method has terminated, and control has returned 
         to the configuration manager. 
551  IPL vary-on is running. 
552  IPL vary-on failed. 
553  IPL phase 1 is complete. 
554  The boot device could not be opened or read, or unable to define NFS swap 
        device during network boot. 
555  An ODM error when trying to vary-on  rootvg, or unable to create an NFS swap device  
556  Logical Volume Manager encountered error during IPL vary-on. 
557  The root filesystem does not mount. 
558  There is not enough memory to continue the system IPL. 
559  Less than 2 M bytes of good memory are available to load the AIX kernel. 
570  Virtual SCSI devices being configured. 
571  HIPPI common function device driver being configured. 
572  HIPPI IPI-3 master transport driver being configured. 
573  HIPPI IPI-3 slave transport driver being configured. 
574  HIPPI IPI-3 transport services user interface device driver being configured. 
575  A 9570 disk-array driver is being configured. 
576  Generic async device driver being configured. 
577  Generic SCSI device driver being configured. 
578  Generic commo device driver being configured. 
579  Device driver being configured for a generic device. 
580  HIPPI TCPIP network interface driver being configured. 
581  Configuring TCP/IP. 
582  Configuring Token-Ring data link control. 
583  Configuring an Ethernet data link control. 
584  Configuring an IEEE Ethernet data link control. 
585  Configuring an SDLC MPQP data link control. 
586  Configuring a QLLC X.25 data link control. 
587  Configuring a NETBIOS. 
588  Configuring a Bisync Read-Write (BSCRW). 
589  SCSI target mode device being configured. 
590  Diskless remote paging device being configured. 
591  Configuring an LVM device driver. 
592  Configuring an HFT device driver. 
593  Configuring SNA device drivers. 
594  Asynchronous I/O being defined or configured. 
595  X.31 pseudo-device being configured. 
596  SNA DLC/LAPE pseudo-device being configured. 
597  OCS software being configured. 
598  OCS hosts being configured during system reboot. 
599  Configuring FDDI data link control. 
5c0  Streams-based hardware drive being configured. 
5c1  Streams-based X.25 protocol being configured. 
5c2  Streams-based X.25 COMIO emulator driver being configured. 
5c3  Streams-based X.25 TCP/IP interface driver being configured. 
5c4  FCS adapter device driver being configured. 
5c5  SCB network device driver for FCS is being configured. 
5c6  AIX SNA channel being configured. 
600  Starting network boot portion of /sbin/rc.boot 
602  Configuring network parent devices. 
603  /usr/lib/methods/defsys, /usr/lib/methods/cfgsys, or /usr/lib/methods/cfgbus failed. 
604  Configuring physical network boot device. 
605  Configuration of physical network boot device failed. 
606  Running /usr/sbin/ifconfig on logical network boot device. 
607  /usr/sbin/ifconfig failed. 
608  Attempting retrieve client.info file with tftp. Note that a 
        flashing 608 indicates multiple attempt(s) 
609  The client.info file does not exist or it is zero length. 
610  Attempting remote mount of NFS file system. 
611  Remote mount of the NFS file system failed. 
612  Accessing remote files; unconfiguring network boot device. 
614  Configuring local paging devices. 
615  Configuration of a local paging device failed. 
616  Converting from diskless to dataless configuration. 
617  Diskless to dataless configuration failed. 
618  Configuring remote (NFS) paging devices. 
619  Configuration of a remote (NFS) paging device failed. 
620  Updating special device files and ODM in permanent 
        filesystem with data from boot RAM filesystem. 
622  Boot process configuring for operating system installation. 
650  IBM SCSD disk drive being configured 
658  PCI Fibre Channel Disk Subsystem Controller being identified or configured. 
659  2102 Fibre Channel Disk Subsystem Controller Drawer being identified or configured. 
660  2102 Fibre Channel Disk Array being identified or configured. 
662  Ultra2 Intergrated SCSI controller. 
663  IBM ARTIC960 RxD PCI Adapter is being configured 
664  32x (MAX) SCSI-2 CD-ROM drive being configured 
669  PCI Gigabit Ethernet Adapter 
674  ESCON® Channel PCI Adapter 
677  PCI Fiber Channel Arbitrated Loop Adapter 
682  20x (MAX) SCSI-2 CD-ROM Drive being configured 
638  4.5GB Ultra SCSI Single Ended Disk Drive being configured 
689  4.5GB Ultra SCSI Single Ended Disk Drive being configured 
690  9.1GB Ultra SCSI Single Ended Disk Drive being configured 
700A  1.1 GB 8-bit SCSI disk drive being identified or configured. 
701A  1.1 GB 16-bit SCSI disk drive is being identified or configured. 
702A  1.1 GB 16-bit differential SCSI disk drive is being identified or configured. 
703A  2.2 GB 8-bit SCSI disk drive is being identified or configured. 
704A  2.2 GB 16-bit SCSI disk drive is being identified or configured. 
705    Configuration method for the 2.2 GB 16-bit differential SCSI 
          disk drive being run. If irrecoverable, halt.
706A  4.5 GB 16-bit SCSI disk drive is being identified or configured. 
707A  4.5 GB 16-bit differential SCSI disk drive is being identified or configured. 
708A  L2 cache is being identified or configured. 
710   POWER GXT150M graphics adapter being identified or configured. 
711  Unknown adapter being identified or configured. 
712  Graphics slot bus configuration is executing. 
713  The IBM ARTIC960 device is being configured. 
714  A video capture adapter is being configured. 
715  The Ultramedia Services audio adapter is being configured. 
        This LED displays briefly on the panel. 
717  TP Ethernet Adapter being configured. 
718  GXT500 Graphics Adapter being configured. 
720  Unknown read/write optical drive type being configured. 
721  Unknown disk or SCSI device being identified or configured. 
722  Unknown disk being identified or configured. 
723  Unknown CD-ROM being identified or configured. 
724  Unknown tape drive being identified or configured. 
725  Unknown display adapter being identified or configured. 
726  Unknown input device being identified or configured. 
727  Unknown async device being identified or configured. 
728  Parallel printer being identified or configured. 
729  Unknown parallel device being identified or configured. 
730  Unknown diskette drive being identified or configured. 
731  PTY being identified or configured. 
732  Unknown SCSI initiator type being configured. 
733  7GB 8mm tape drive being configured. 
734  4x SCSI-2 640MB CD-ROM Drive 
736  Quiet Touch keyboard and speaker cable being configured. 
741  1080MB SCSI Disk Drive 
745  16GB 4mm Tape Auto Loader 
746  SCSI-2 Fast/Wide PCI Adapter 
747  SCSI-2 Differential Fast/Wide PCI Adapter 
749  7331 Model 205 Tape Library 
751  SCSI 32-bit SE F/W RAID Adapter 
754  1.1GB 16-bit SCSI disk drive being configured. 
755  2.2GB 16-bit SCSI disk drive being configured. 
756  4.5GB 16-bit SCSI disk drive being configured. 
757  External 13GB 1.5M/s 1/4 inch tape being configured. 
763  SP Switch MX Adapter 
764  SP System Attachment Adapter 
772  4.5GB SCSI F/W Disk Drive 
773  9.1GB SCSI F/W Disk Drive 
774  9.1GB External SCSI Disk Drive 
777  10/100Mbps PCI Ethernet Adapter being identified or configured. 
778  POWER GXT3000P 3D PCI Graphics adapter being configured 
77c  A 1.0 GB 16-bit SCSI disk drive being identified or configured. 
783  4mm DDS-2 Tape Autoloader 
789  2.6GB External Optical Drive 
78c  PCI bus configuration executing 
790  Multi-bus Integrated Ethernet Adapter being identified or configured. 
797  TURBOWAYS® 155 UTP/STP ATM Adapter being identified or configured. 
798  Video streamer adapter being identified or configured. 
79c  ISA bus configuration executing 
7cc  PCMCIA bus configuration executing 
800  TURBOWAYS 155 MMF ATM Adapter being identified or configured. 
803  7336 Tape Library robotics being configured 
804  8x Speed SCSI-2 CD-ROM Drive being configured 
806  POWER GXT800 PCI Graphics adapter being configured 
807  SCSI Device Enclosure being configured 
80c  SSA 4-Port Adapter being identified or configured. 
811  Processor complex being identified or configured. 
812  Memory being identified or configured. 
813  Battery for time-of-day, NVRAM,  system I/O control logic being identified or configured. 
814  NVRAM being identified or configured. 
815  Floating-point processor test 
816  Operator panel logic being identified or configured. 
817  Time-of-day logic being identified or configured. 
819  Graphics input device adapter being identified or configured. 
821  Standard keyboard adapter being identified or configured. 
823  Standard mouse adapter being identified or configured. 
824  Standard tablet adapter being identified or configured. 
825  Standard speaker adapter being identified or configured. 
826  Serial Port 1 adapter being identified or configured. 
827  Parallel port adapter being identified or configured. 
828  Standard diskette adapter being identified or configured. 
831  3151 adapter being identified or configured, or Serial Port 2 being identified or configured. 
834  64-port async controller being identified or configured. 
835  16-port async concentrator being identified or configured. 
836  128-port async controller being identified or configured. 
837  16-port remote async node being identified or configured. 
838  Network Terminal Accelerator Adapter being identified or configured. 
839  7318 Serial Communications Server being configured. 
841  8-port async adapter (EIA-232) being identified or configured. 
842  8-port async adapter (EIA-422A) being identified or configured. 
843  8-port async adapter (MIL-STD 188) being identified or configured. 
844  7135 RAIDiant Array disk drive subsystem controller being identified or configured. 
845  7135 RAIDiant Array disk drive subsystem drawer being identified or configured. 
846  RAIDiant Array SCSI 1.3GB Disk Drive 
847  16-port serial adapter (EIA-232) being identified or configured. 
848  16-port serial adapter (EIA-422) being identified or configured. 
849  X.25 Interface Co-Processor/2 adapter being identified or configured. 
850  Token-Ring network adapter being identified or configured. 
851  T1/J1 Portmaster® adapter being identified or configured. 
852  Ethernet adapter being identified or configured. 
854  3270 Host Connection Program/6000 connection being identified or configured. 
855  Portmaster Adapter/A being identified or configured. 
857  FSLA adapter being identified or configured. 
858  5085/5086/5088 adapter being identified or configured. 
859  FDDI adapter being identified or configured. 
85c  Token-Ring High-Performance LAN adapter is being identified or configured. 
861  Optical adapter being identified or configured. 
862  Block Multiplexer Channel Adapter being identified or configured. 
865  ESCON Channel Adapter or emulator being identified or configured. 
866  SCSI adapter being identified or configured. 
867  Async expansion adapter being identified or configured. 
868  SCSI adapter being identified or configured. 
869  SCSI adapter being identified or configured. 
870  Serial disk drive adapter being identified or configured. 
871  Graphics subsystem adapter being identified or configured. 
872  Grayscale graphics adapter being identified or configured. 
874  Color graphics adapter being identified or configured. 
875  Vendor generic communication adapter being configured. 
876  8-bit color graphics processor being identified or configured. 
877  POWER Gt3(TM)/POWER Gt4(TM) being identified or configured. 
878  POWER Gt4 graphics processor card being configured. 
879  24-bit color graphics card, MEV2 
880  POWER Gt1(TM) adapter being identified or configured. 
887  Integrated Ethernet adapter being identified or configured. 
889  SCSI adapter being identified or configured. 
890  SCSI-2 Differential Fast/Wide and Single-Ended Fast/Wide Adapter/A. 
891  Vendor SCSI adapter being identified or configured. 
892  Vendor display adapter being identified or configured. 
893  Vendor LAN adapter being identified or configured. 
894  Vendor async/communications adapter being identified or configured. 
895  Vendor IEEE 488 adapter being identified or configured. 
896  Vendor VME bus adapter being identified or configured. 
897  S /370(TM) Channel Emulator adapter being identified or configured. 
898  POWER Gt1x(TM) graphics adapter being identified or configured. 
899  3490 attached tape drive being identified or configured. 
89c  A multimedia SCSI CD-ROM is being identified or configured. 
900  GXT110P Graphics Adapter being identified or configured. 
901  Vendor SCSI device being identified or configured. 
902  Vendor display device being identified or configured. 
903  Vendor async device being identified or configured. 
904  Vendor parallel device being identified or configured. 
905  Vendor other device being identified or configured. 
908  POWER GXT1000 Graphics subsystem being identified or configured. 
910  1/4GB Fiber Channel/266 Standard Adapter being identified or configured. 
911  Fiber Channel/1063 Adapter Short Wave 
912  2.0GB SCSI-2 differential disk drive being identified or configured. 
913  1.0GB differential disk drive being identified or configured. 
914  5GB 8mm differential tape drive being identified or configured. 
915  4GB 4mm tape drive being identified or configured. 
916  Non-SCSI vendor tape adapter being identified or configured. 
917  A 2.0GB 16-bit differential SCSI disk drive is being identified or configured. 
918  A 2GB 16-bit single-ended SCSI disk drive is being identified or configured. 
920  Bridge Box being identified or configured. 
921  101 keyboard being identified or configured. 
922  102 keyboard being identified or configured. 
923  Kanji keyboard being identified or configured. 
924  Two-button mouse being identified or configured. 
925  Three-button mouse being identified or configured. 
926  5083 tablet being identified or configured. 
927  5083 tablet being identified or configured. 
928  Standard speaker being identified or configured. 
929  Dials being identified or configured. 
930  Lighted program function keys (LPFK) being identified or configured. 
931  IP router being identified or configured. 
933  Async planar being identified or configured. 
934  Async expansion drawer being identified or configured. 
935  3.5-inch diskette drive being identified or configured. 
936  5.25-inch diskette drive being identified or configured. 
937  An HIPPI adapter is being configured. 
942  POWER GXT 100 graphics adapter being identified or configured. 
943  A 3480 or 3490 control unit attached to a System/370 Channel 
        Emulator/A adapter configured. 
944  100MB ATM adapter being identified or configured 
945  1.0GB SCSI differential disk drive being identified or configured. 
946  Serial port 3 adapter is being identified or configured. 
947  A 730MB SCSI disk drive is being configured. 
948  Portable disk drive being identified or configured. 
949  Unknown direct bus-attach device being identified or configured. 
950  Missing SCSI device being identified or configured. 
951  670MB SCSI disk drive being identified or configured. 
952  355MB SCSI disk drive being identified or configured. 
953  320MB SCSI disk drive being identified or configured. 
954  400MB SCSI disk drive being identified or configured. 
955  857MB SCSI disk drive being identified or configured. 
956  670MB SCSI disk drive electronics card being identified or configured. 
957  120MB DBA disk drive being identified or configured. 
958  160MB DBA disk drive being identified or configured. 
959  160MB SCSI disk drive being identified or configured. 
960  1.37GB SCSI disk drive being identified or configured. 
964  Internal 20GB 8mm tape drive identified or configured. 
968  1.0GB SCSI disk drive being identified or configured. 
970  Half-inch, 9-track tape drive being identified or configured. 
971  150MB 1/4-inch tape drive being identified or configured. 
972  2.3GB 8mm SCSI tape drive being identified or configured. 
973  Other SCSI tape drive being identified or configured. 
974  CD-ROM drive being identified or configured. 
975 An optical disk drive is being identified or configured. 
977 M-Audio Capture and Playback Adapter being identified or configured. 
981 540MB SCSI-2 single-ended disk drive being identified or configured. 
984 1GB 8-bit disk drive being identified or configured. 
985 M-Video Capture Adapter being identified or configured. 
986 2.4GB SCSI disk drive being identified or configured. 
987 An Enhanced SCSI CD-ROM drive is being identified or configured. 
989 200MB SCSI disk drive being identified or configured. 
990 2.0GB SCSI-2 single-ended disk drive being identified or configured. 
991 525MB 1/4-inch cartridge tape drive being identified or configured. 
994 5GB 8mm tape drive being identified or configured. 
995 1.2GB 1/4 inch cartridge tape drive being identified or configured. 
996 A single-port, multi-protocol communications adapter is being identified or configured. 
997 FDDI adapter being identified or configured. 
998 2.0GB 4mm tape drive being identified or configured. 
999 7137 or 3514 Disk Array Subsystem being configured. 
D81 T2 Ethernet Adapter being configured. 


Table 5-1. Service Processor Checkpoints.

E010   Starting Service Processor self-tests 
E012   Begin to set up Service Processor heaps 
E020   Configuring CMOS 
E021   Configuring NVRAM 
E040   Configuring Service Processor I/O 
E042   Configuring modem on serial port 1 
E043   Configuring modem on serial port 2 
E04F   Modem configuration successful Re-IPL. 
E070   Service Processor is calling the Service Center 
E071   Service Processor is calling System Administration 
E072   Service Processor is calling the pager 
E075   Entering Service Processor menus 

Before replacing any parts, ensure the S1 and S2 ports either have no cables attached or the
cables are only attached to TTY or Modem devices. 

E07A  Waiting for keystroke from local console 
E07B  Waiting for keystroke from remote console 
E07F   Service Processor exiting from session with local or remote terminal. 
E080   Service Processor flash update in progress 
E081   Service Processor flash update completed 
E082   Service Processor promoting flash from side B to side A. 
E090   Changing the system processor configuration. 
E0EF   End of Service Processor reporting 


Firmware Checkpoints 
E100   Reserved 
E101   Video enabled, extended memory test 
E102   Firmware restart 
E103   Set memory refresh (composite img) 
E104   Set memory refresh (recovery block) 
E105   Transfer control to Operating System (normal boot). 
E108   Run recovery block base memory (test 2K),
E109   Copy CRC verification code to RAM 
E10A   Turn on cache 
E10B   Flush cache 
E10C   Jump to CRC verification code in RAM 
E10D   Compute composite image CRC 
E10E   Jump back to ROM 
E10F   Transfer control to Open Firmware 
E110   Turn off cache, Check if composite image CRC is valid 
E111   GOOD CRC - jump to composite image 
E112   BAD CRC - initialize base memory, stack 
E113   BAD CRC - copy uncompressed recovery block code to RAM 
E114   BAD CRC - jump to code in RAM 
E115   BAD CRC - turn on cache 
E116   BAD CRC - copy recovery block data section to RAM 
E117   BAD CRC - Invalidate and flush cache, set TOC 
E118   BAD CRC - branch to high level recovery control routine. 
E119   Initialize base memory, stack 
E11A   Copy uncompressed recovery block code to RAM 
E11B   Jump to code in RAM 
E11C   Turn on cache 
E11D   Copy recovery block data section to RAM 
E11E   Invalidate and flush cache, set TOC 
E11F   Branch to high level control routine. 
E120   Initialize I/O and early memory block 
E121   Initialize S.P. 
E125   Clear PCI devices command reg, go forth 
E126   Check valid image - start 
E127   Check valid image - successful 
E128   Disable interrupts, set int vectors for O.F. 
E129   Validate target RAM address 
E12A   copy to RAM, flush cache 
E12B   Set MP operational parameters 
E12C   Set MP cpu node characteristics 
E12D   Park secondary processors in parking lot 
E12E   Primary processor sync 
E12F   Unexpected return from Open Firmware (system lockup) 
E130   Build device tree 
E131   Create ROOT node 
E132   Create cpus node 
E133   Create L2 Cache node 
E134   Create memory node 
E135   Create memory DIMM node 
E136   Test memory 
E137   Create openprom node 
E138   Create options node 
E139   Create aliases node and system aliases 
E13A   Create packages node 
E140   PReP style load 
E149   Create boot mgr node 
E14C   Create terminal-emulator node 
E14D   Loading boot image 
E14E   Create client interface node/directory 
E14F   NVRAM initialization 
E150   Create host (primary) PCI controller node 
E151   Probing primary PCI bus 
E152   Probing for adapter FCODE, evaluate if present 
E153   End adapter FCODE, probe/evaluate 
E154   Create PCI bridge node 
E155   Probing PCI bridge secondary bus 
E156   Create PCI ethernet node 
E15A  Create 64 bit host (primary) PCI controller node 
E15B  Transferring control to Operating System (service mode boot) 
E15C  Probe primary 64 bit PCI bus 
E15D  Create host PCI controller node 
E15E   Create MPIC node 
E15F   Adapter VPD probe 
E160   CPU node VPD creation 
E161   Create memory VPD 
E162   SP node VPD creation 
E163   Create CPU VPD 
E164   Create PCI graphic node (P9) 
E165   Create planar-clock VPD 
E166   Create CEC VPD 
E167   Create 7 EIA-Unit I/O Drawer VPD 
E168   Create PCI graphic node (S3) 
E169   Create 10 EIA-Unit I/O Drawer VPD 
E170   Start of PCI Bus Probe 
E171   Executing PCI-Delay function 
E174   Establishing host connection  (incorrect IP parameter)
E175   BootP request Refer checkpoint E174. 
E176   TFTP file transfer 
E177   Transfer failure due to TFTP error condition 
E178   Create PCI token ring node 
E180   Service Processor Command setup 
E181   Send drawer data to I/O planar 
E182   Request 10 EIA-Unit I/O Drawer I/O planar VPD 
E183   Service Processor Post 
E184   Request 10 EIA-Unit I/O Drawer drawer interface panel VPD 
E185   Add 10 EIA-Unit I/O Drawer drawer interface panel VPD to NVram and device tree 
E186   Request PS1 VPD 
E187   Add PS1 VPD to NVRAM and device tree 
E188   Request PS2 VPD 
E189   Add PS2 VPD to NVRAM and device tree 
E18A   Request fan monitoring card VPD 
E18B   Add fan monitoring card VPD to NVRAM and device tree 
E18C   VPD and data communications with I/O planar complete 
E190   Create ISA node 
E191   Create ISA reserved node 
E193   Initialize Super I/O 
E196   Probe ISA bus 
E19B   Create Service Processor node 
E19C   Create tablet node 
E19D   Create nvram node 
E19E   Real time clock (RTC) initialization Refer to error code 
            28030xxx in "Firmware/POST Error Codes". 
E1AD  See description of checkpoint E1DE 
E1B0   Create lpt node 
E1B1   Create serial node 
E1B2   Create audio node 
E1B3   Create 8042 node 
E1B6   Probe for (ISA) keyboard 
E1BA  Enable L2 cache 
E1BB  Set cache parms for burst 
E1BC  Set cache parms for 512KB 
E1BD  Probe for (ISA) mouse 
E1BE  Create op-panel node 
E1BF  Create pwr-mgmt node 
E1C0  Create ISA ethernet node 
E1C5  Create ISA interrupt controller (pic) node 
E1C6  Create DMA node 
E1D0  Create PCI SCSI node 
E1D3  Create (* wildcard *) SCSI block device node (SD) 
E1D4  Create (* wildcard *) SCSI byte device node (ST) 
E1DB  Create floppy controller (fdc) node 
E1DC  Dynamic console selection. (maybe cable or keyboard)
E1DD  Early processor exception 
E1DE  Alternating pattern of E1DE and E1AD is used to 
            indicate a Default Catch condition before the firmware "checkpoint" 
            word is available. 
E1DF  Create diskette drive (disk) node 
E1E0  Program flash 
E1E1  Flash update complete 
E1E2  Initialize System I/O 
E1E3  PReP boot image initialization. 
E1E4  Initialize Super I/O with default values 
E1E5  XCOFF boot image initialization 
E1E6  Set up early memory allocation heap 
E1E7  PE boot image initialization 
E1E8  Initialize primary diskette drive (polled mode)
E1E9  ELF boot image initialization 
E1F0  Start O.B.E. 
E1F1  Begin self test sequence on boot device(s) Begin SMS. 
E1F2  Power-On Password prompt. 
E1F3  Privileged-Access Password prompt 
E1F5  Build boot device list 
E1F6  Determine boot device sequence 
E1F7  No boot image located 
E1FB  Scan SCSI bus for attached devices 
E1FD  The operator panel will alternate between the code E1FD 
             and another Exxx code, where
Exxx is the point at which the error occurred. 
E440  Validate nvram, initialize partitions as needed. Verify that 
            the system firmware levels are at the current release levels, update 
            as necessary. Replace Service Processor Card
E441 Generate /options node nvram configuration variable properties 
E442 Validate nvram partitions 
E443 Generate nvram configuration variable dictionary words.
          Suspect a system firmware problem 
E500  Configure Remote I/O subsystem 
E5xy (E511 - E5FF)
Where x is not equal to 0, and y is not equal to 0. Configure Remote I/O subsystem components 
The E5xy (E511 to E5FF) codes are reserved for activities relating to configuration or testing of the I/O subsystem, or remote I/O subsystem. A hang at one of these codes implies that 
a severe error occurred during the programming of I/O subsystem registers or when interacting with adapters plugged into the system. The last two digits in the checkpoint can be used to help isolate the location of the I/O activity that caused the problem. 

"x" indicates the I/O drawer number. "y" indicates the
PCI bus occurance. 
If x=_, then the I/O Drawer is: 
X = I/O Drawer
1 = 0
2 = 1
3 = 2
4 = 3

If y=_, then the PCI Bus is: 
Y = PCI Bus
1 = 0
2 = 1
3 = 2
4 = 3


Base Level Error Codes 
                    ________________________________________________________
                    Digit 1 ³ Digit 2  ³ Digit 3 | Type of Failure
                     blank  ³  blank   |  blank  | None
                       8    ³          |         | Fan P49B
                       4    ³          |         | Fan P49C.
                       u    ³          |         | = Digit 1 Codes 8 and 4.
                            ³    8     |         | Fan at P47.
                            ³    4     |         | Fan P46A or P46 or both.
                            ³    2     |         | Fan P49A.
                            |    6     |         | = Digit 2 Codes 4 and 2.
                            |    c     |         | = Digit 2 codes 8 and 2.
                            |    u     |         | = Digit 2 codes 8 and 4.
                            |Inverted F|         | = Digit 2 codes 8, 4 and 2.
                            |          |    8    | Excessive temperature in PS
                            |          |    4    | Power failure in PS
                            |          |    2    | Power failure outside PS
                            |          |    1    | Loss of primary power.    

      Service Request Number List for Multiple Bus Systems
Replace FRU parts in the order by which the "Failing Function Codes" are
listed.
  Service            Failing    Description and Action
  Request            Function   (Unless otherwise indicated use Chapter 12.
  Number             Codes     "MAP 0210: General Problem Resolution".)
             SRN
            Src.
  

10112                         Description: Format Degraded. A Format
                              operation has been ended before it has completed.
                              Action: Refer to the Service Guide for the
                              unit containing the disk drive.
1XXXX                         Description: Disk drive module error.
                              Action: Refer to the Service Guide for the
                              unit containing the disk drive.
                              Note: In this SRN, an X represents a digit
                              0 through F.
   
20PAA                         Description: An open SSA loop has been detected.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.
   
21PAA                         Description: An SSA 'Threshold exceeded'
     to                       link error has been detected.
29PAA                         Action: Go to the Intermittent Link Error
                              MAP in the SSA Adapters: User's Guide and
                              Maintenance Information.

2A002                         Description: Async code 02 has been
                              received. Probably, a software error has occurred.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2A003                         Description: Async code 03 has been
                              received. Probably, a software error has occurred.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2A004                         Description: Async code 04 has been
                              received. Probably, a software error has occurred.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2A005                         Description: Async code 05 has been
                              received. This code indicates that a disk
                              drive module has detected the loss of
                              redundant power or cooling.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2A006                         Description: Async code 06 has been
                              received. This code indicates that a disk
                              drive module has detected the loss of
                              redundant power or cooling.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2A106                         Description: Async code 06 has been
                              received. This code indicates that multiple
                              disk drive modules have detected the loss
                              of redundant power or cooling.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drives.

2A206                         Description: A disk drive module has
                              detected that one of its SSA links has
                              failed the POST.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

2FFFF                         Description: An async code that is not
                              valid has been received.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

300C0                         Description: A disk drive module has
                              detected the loss of redundant power or cooling.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

301C0                         Description: Multiple disk drive modules
                              have detected the loss of redundant power or cooling.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drives.


303FF                         Description: An SCSI status that is not
                              valid has been received.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

31000                         Description: The disk drive has been
                              reset by the adapter. The disk drive might
                              be going to fail.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

40000                         Description: The SSA adapter card has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40004                         Description: A 4MB DRAM module in adapter
                              card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40008                         Description: An 8MB DRAM module in
                              adapter card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40016                         Description: A 16MB DRAM module in
                              adapter card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40032                         Description: A 32MB DRAM module in
                              adapter card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40064                         Description: A 64MB DRAM module in
                              adapter card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

40128                         Description: A 128MB DRAM module in
                              adapter card slot 0 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41004                         Description: A 4MB DRAM module in adapter
                              card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41008                         Description: An 8MB DRAM module in
                              adapter card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41016                         Description: A 16MB DRAM module in
                              adapter card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41032                         Description: A 32MB DRAM module in
                              adapter card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41064                         Description: A 64MB DRAM module in
                              adapter card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

41128                         Description: A 128MB DRAM module in
                              adapter card slot 1 has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42000                         Description: The SSA adapter has detected
                              that both DRAM modules are failing.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42200                         Description: Other adapters on the SSA
                              loop are using levels of microcode that are
                              not compatible.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42500                         Description: An SSA adapter has detected
                              a failure in its fast-write cache.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42510                         Description: Not enough DRAM available to
                              run an SSA fast-write cache.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42515                         Description: An SSA adapter is attempting
                              to use its fast-write cache, but a
                              fast-write cache card is not installed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42520                         Description: An SSA fast-write cache
                              failure has been detected.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42521                         Description: An SSA fast-write cache
                              failure has been detected.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42522                         Description: An SSA fast-write cache
                              failure has been detected.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42523                         Description: A incorrect version number
                              has been detected in an SSA resource.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42524                         Description: An SSA write-cache resource
                              is not available.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42525                         Description: An incorrect SSA write-cache
                              resource has been identified.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42526                         Description: This adapter does not
                              support the SSA Fast-Write Cache Option.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42527                         Description: A dormant SSA fast-write
                              cache entry exists.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

42528                         Description: A fast-write SSA disk drive
                              has been detected that was previously
                              unsynchronized, but has since been
                              configured on a different adapter.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

43PAA                         Description: An SSA device on the loop is
                              preventing the completion of the loop configuration.
                              Action: Refer to the user's or service
                              guide for the unit containing the device.

44PAA                         Description: A disk drive module has a
                              'Failed' status.
                              Action: Refer to the Service Guide for the
                              unit containing the disk drive.

45PAA                         Description: The SSA adapter has detected
                              an open SSA loop. This problem is caused
                              either by a disk drive module that is
                              failing, or by a disk drive module that has
                              been turned off from another using system
                              on the same SSA loop. (That using system
                              has itself been turned off.)
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

46000                         Description: A RAID array is the Offline
                              state because more than one disk drive is
                              not available. At least one member disk
                              drive of the array is present, but more
                              than one member disk drive is missing.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

46500                         Description: A member disk drive is
                              missing from a SSA array.                              
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

47000                         Description: An attempt has been made to
                              store in the SSA adapter the details of
                              more than 32 RAID arrays.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

47500                         Description: Part of the RAID array data
                              might have been lost.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.
  
48000                         Description: The SSA adapter has detected
                              a link configuration that is not valid.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

48600                         Description: Member disk drives of an SSA
                              array are not all on the same SSA loop, in
                              a multiple-host-system configuration.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

48700                         Description: Two or more member disk
                              drives of an SSA array are on different loops.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

48800                         Description: The SSA RAID strip table is not valid.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

48900                         Description: An SSA array is not
                              available; a multiple-device error has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

48950                         Description: An SSA disk drive has failed
                              during a building operation.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

49000                         Description: A RAID array is in the
                              Degraded state because a disk drive is not
                              available to the array, and a write command
                              has been sent to that array.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

49100                         Description: A RAID array is in the
                              Exposed state because a disk drive is not
                              available to the array.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

49500                         Description: No hot spare disk drives are
                              available for a RAID array that is
                              configured for hot spare disk drives.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

49700                         Description: The parity for the RAID
                              array is not complete.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

4A100                         Description: The adapter cannot
                              initialize an SSA disk drive.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

4BPAA                         Description: An SSA disk drive at PAA
                              cannot be configured, because its UID
                              cannot be read.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50000                         Description: The SSA adapter failed to
                              respond to the device driver.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50001                         Description: A data parity error has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50002                         Description: An SSA adapter DMA error has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50004                         Description: Channel check.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50005                         Description: A software error has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50006                         Description: A channel check has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50007                         Description: The IOCC detected an
                              internal error.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50008                         Description: Unable to read or write the
                              POS registers.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50010                         Description: An SSA adapter or
                              device-driver protocol error has occurred.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50012                         Description: The SSA adapter microcode has hung.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50013                         Description: The SSA adapter card has failed.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50100                         Description: An attempt was made to log
                              an error against a pdisk that is not
                              available to the using system.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50200                         Description: Duplicate SSA cluster number detected.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50411                         Description: SSA adapter has detected an
                              SS_SIC_CLASS1 error.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

50425                         Description: SSA adapter has detected an
                              SS_LINK_CONFIG_FAILED error.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

504XX                         Description: The SSA adapter microcode has hung.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

60000                         Description: The SSA adapter is missing
                              from the expected configuration.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

60200                         Description: The SSA unit cannot be turned on.
                              Action: Refer to the Service Guide for the unit.

60210                         Description: A disk drive module has its
                              Check light on.
                              Action: Refer to the Service Guide for the
                              unit containing the disk drive.
  
60220                         Description: A fan-and-power-supply
                              assembly has its Check light on.
                              Action: Refer to the Service Guide for the
                              unit containing the device that the error
                              was reported against.
 
60230                         Description: The SSA unit has an
                              unexpected Check light on.
                              Action: Refer to the Service Guide for the unit.
   
60240                         Description: An SSA configuration problem
                              has occurred. An SSA device cannot be configured.
                              Action: Refer to the Service Guide for the
                              unit containing the device.

7XXXX                         Description: An SSA disk drive is missing
                              from the expected configuration of the SSA loop.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk
                              drive.Note: In this SRN, an X represents a digit
                              0 through F.

D0000                         Description: The using system cannot
                              configure the disk drive module.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0100                         Description: Unable to clear a disk drive
                              module reservation.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0101                         Description: The disk drive module has
                              been reserved since the diagnostics started.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0200                         Description: The disk drive module timed
                              out while the diagnostics were running.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0300                         Description: The disk drive module failed
                              the diagnostic test.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0400                         Description: The disk drive module is not
                              ready while the diagnostics are running.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0450                         Description: The Format operation that
                              was started on this disk drive module has
                              not yet finished.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.

D0460                         Description: A Format operation has been degraded.
                              Action: Refer to the user's or service
                              guide for the unit containing the disk drive.
   
D4000                         Description: The diagnostics cannot
                              configure the SSA adapter.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.
 
D4100                         Description: The diagnostics cannot open
                              the SSA adapter.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

D4300                         Description: The diagnostics have
                              detected an SSA adapter POST failure.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

D44XX                         Description: The diagnostics have
                              detected that the SSA adapter has corrupted
                              the microcode, but cannot download a new
                              version of the microcode.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.                               
                              Note: In this SRN, an X represents a digit
                              0 through F.

DFFFF                         Description: A command or parameter that
                              has been sent or received is not valid.
                              This problem is caused either by the SSA
                              adapter, or by an error in the microcode.
                              Action: Refer to the SSA Adapters: User's
                              Guide and Maintenance Information.

101-000     A                 Description: The system hung while
                              attempting to configure a device.
                              Action: Use MAP 1540.

101-185     A                 Description: A checkstop occurred.
                              Action: Use MAP 1540 in the system unit
                              service guide to isolate the cause.

101-517     A                 Description: The system unit failed to IPL.
                              Action: Use MAP 1540.

101-518     A                 Description: CD-ROM read problems after boot.
                              Note:The boot record was read from the
                              CD-ROM disk. However, errors occurred when
                              trying to mount the CD-ROM file system.
                              This problem can be caused by SCSI device
                              addressing, SCSI terminator, open PTC, SCSI
                              cable, etc.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure"
                       
                              Description: The configuration manager
101-521     A                 detected an error.
   to                         Action: If you are running the diagnostics
101-538                       from a disk, try running the diagnostics
                              from a CD-ROM. If the diagnostics run
                              correctly from CD-ROM, the problem may be
                              damaged data on the disk. Contact your
                              software support facility. If a different
                              problem occurs when you run the diagnostics
                              from CD ROM, correct that problem. If you
                              were running from a CD ROM at first, or
                              have the same problem on CD ROM that you
                              had when running diagnostics from disk then
                              go to MAP 1540, in either the service guide
                              or the installation and service guide for
                              this system unit.
                   
                                 
101-544     A                Description: Disk read problems occurred after booting.
                             errors occurred when trying to open the
                             disk drive. This problem can be caused by
                             SCSI device addressing, SCSI terminator,
                             open PTC, SCSI cable, etc.
                             Action: Go to Chapter 7. "MAP 0050: SCSI
                             Problems Isolation Procedure"
                   
                               
101-551     A                Description: The system hung while
                             loading the software. This can be caused by
     to                      a hardware or software problem.
101-557                      Action: Run the diagnostics from CD-ROM.
                             Start at Chapter 4. "MAP 0020: Problem
                             Determination Procedure", Step 14. If the
                             diagnostics run correctly from CD-ROM, the
                             problem may be damaged disk data. Consider
                             having the customer contact Software
                             Support before reinstalling the operating
                             system on the disk. If you still get the
                             same SRN, go to MAP 1540 in either the
                             service guide or the installation and
                             service guide for this system unit.
                  
                             Description: There is not enough memory
101-558     A                to execute diagnostics.
                             Action: There must be a minimum of 16MB of
                             installed memory. If the system has 16MB or
                             more of memory installed, suspect a problem
                             with a memory card.
  
101-559     A                Description: The system halted while
                             software was loading. This problem may be
     to                      attributed to either hardware or software.
                             Action: Use the CD ROM based diagnostics if
101-599                      not yet used. If the same SRN is generated
                             from the CD ROM diagnostics, go to MAP 1540
                             in the system unit service guide for
                             problem isolation.
                             If the SRN is not generated when using the
                             CD ROM, suspect a problem with the system's software.

              
101-711    A        xxx     Description: The system hung while trying
                            to configure an unknown resource.
   to                       Action: Run diagnostics from CD-ROM. Start
101-726                     at Chapter 4. "MAP 0020: Problem
                            Determination Procedure", Step 14. If you
                            still get the same SRN, refer to "Failing
                            Function Code List" and find the FFC that
                            matches the last three digits of the SRN.
                            Suspect the device adapter or device
                            itself. If more than one adapter or device
                            is installed, isolate the failing resource
                            by removing the adapters or devices one at
                            a time and checking if the system stops
                            with the same value in the three-digit
                            display.Note: xxx corresponds to the last three
                            digits of the SRN.

                               
101-727     A               Description: The system hung while trying
                            to configure an asynchronous adapter.
                            Action: Use MAP 1540 in the installation
                            and service guide for this system unit.
                            Suspect a problem with one of the async adapters.

101-7C1     A       7C1     Description: The system unit halted while
                            configuring an audio subsystem.

101-888     A       210     Description: The system does not IPL.
                            Action: Use Chapter 16. "MAP 0260: System
                    227     Hangs During Resource Configuration".
                      
101-c32     D       E10     Description: The system hung while
                            indicating that a direct-attached display
                            was selected as the console.
                            Action: Go to MAP 1540 in either the
                            service guide or the installation and
                            service guide for this system unit. Suspect
                            the graphics adapter being used for the
                            display console first.

101-c33     D               Description: The system hung while
                            indicating that a TTY terminal is the
                            system console.
                            Action: Go to MAP 1540 in either the
                            service guide or the installation and
                            service guide for this system unit. Suspect
                            the graphics adapter being used for the
                            display console first.

101-xxx     A        xxx    Description: The system hung while
                            configuring a resource. The last three
                     227    digits identify the failing function code
                            for the resource being configured.
                            Action: Use Chapter 16. "MAP 0260: System
                            Hangs During Resource Configuration".

103-151     D       151     Description: The time-of-day battery failed.

103-202     H               Description: Unexpected interrupt.
   to                       Action: Go to MAP 1540 in either the
103-210                     service guide or the installation and
                            service guide for this system unit.

109-200     B               Description: The system crashed while
                            being run by the customer.
                            Action: Use Chapter 4. "MAP 0020: Problem
                            Determination Procedure", and get a new SRN.

110-101     C               Description: The diagnostics did not
                            detect an installed resource.
                            Action: If this SRN appeared when running
                            concurrent diagnostics, then run concurrent
                            using the diag -a command, otherwise use
                            Chapter 18. "MAP 0290: Missing Resource
                            Problem Resolution".

110-908     D      908      Description: The system halted while
                            diagnostics were executing.


110-921     D               Description: The system halted while
   to              xxx      diagnostics were executing.
110-926            812      Note: xxx corresponds to the last three
                            digits of the SRN.

110-935     D      935      Description: The system halted while
                            diagnostics were executing.
     
110-946     D      946      Description: The system halted while
                            diagnostics were executing.

110-xxx     D               Description: The system halted while
                   xxx      diagnostics were executing.
                   221      Note: xxx corresponds to the last three
                            digits of the SRN. If your 110 SRN is not
                            listed below, use the 110-xxx procedure.

111-259     B               Description: Cannot display readable
                            information on the terminal.
                            Action: Use Chapter 17. "MAP 0280: Boot
                            Problem Resolution" Entry 3.

111-725     B      725      Description: Cannot display readable
                            information on the display.
                            Note: Suspect the display adapter attached
                            to the console display.
                            Action: Use Chapter 17. "MAP 0280: Boot
                            Problem Resolution"

111-736     B     736      Description: The keyboard does not respond.
                  821      Action: Use Chapter 17. "MAP 0280: Boot
                           Problem Resolution" Entry 1.

111-78C     B   PCI adapter  Description: I/O bus problem.
                             Action: Use Chapter 12. "MAP 0210: General
                             Problem Resolution".
                    E10      Note: PCI adapter refers to the adapters
                             you made note of when using Chapter 11.
                             "MAP 0080 System Bus Problem Isolation".
  
111-82C     B               Description: Cannot display readable
                            information on the display.
                            Action: Go to Chapter 17. "MAP 0280: Boot
                            Problem Resolution" Entry 2.
  
111-922     B       922      Description: The keyboard does not respond.                      
111-923     B       923      Description: The keyboard does not respond.                      
111-947     B       221      Description: System beeper not functioning correctly.  
111-999     D       210      Description: System does not perform a soft reset.  
2E6-212     D       2E6      Description: FIFO empty bit set.                               
2E6-213     D       2E6      Description: FIFO empty bit clear.                               
2E6-214     D       2E6      Description: FIFO full bit set.                               
2E6-215     D       2E6      Description: FIFO full bit clear.                           
2E6-216     D       2E6      Description: FIFO data miscompare.            
2E6-217     D       2E6      Description: SCSI FIFO data miscompare.                               
2E6-218     D       2E6      Description: SCSI FIFO underflow.                       
2E6-219     D       2E6      Description: SCSI parity error.                             
2E6-220     D       2E6      Description: SCSI FIFO flags error.
                      
2E6-221     D       2E6      Description: Miss compare during the
                             write/read of the configuration register.
                      
2E6-222     D       2E6      Description: Error during the write/read
                             of the memory register.
                      
2E6-223     D       2E6      Description: Miss compare during the
                             write/read of the memory I/O register.
                     
2E6-224     D       2E6      Description: Error reading the PCI
                             configuration register.
 
2E6-225     D       2E6      Description: Adapter POST failed. 
2E6-230     D       D50      Description: Arbitration test failed. 
2E6-231     D       D50      Description: Function could not complete.                              
2E6-232     D       D50      Description: SCSI bus data miss compare.                               
2E6-240     D       2E6      Description: No terminal power.
                              
2E6-301     D       2E6      Description: Configuration open failed for
                             parent bus.  SOFTWARE

2E6-700     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. Software

2E6-701     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. Software
 
2E6-702     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. Software
 
2E6-703     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. Software
                    
2E6-704     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.  Software
                               
2E6-705     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.  Software
                    
2E6-800     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                               
2E6-802     G       2E6      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                               
2E7-212     D       2E7      Description: FIFO empty bit set.                               
2E7-213     D       2E7      Description: FIFO empty bit clear.                             
2E7-214     D       2E7      Description: FIFO full bit set.                               
2E7-215     D       2E7      Description: FIFO full bit clear.         
2E7-216     D       2E7      Description: FIFO data miscompare      
2E7-217     D       2E7      Description: SCSI FIFO data miscompare.                               
2E7-218     D       2E7      Description: SCSI FIFO underflow.                 
2E7-219     D       2E7      Description: SCSI parity error.                              
2E7-220     D       2E7      Description: SCSI FIFO flags error.
                             
2E7-221     D       2E7      Description: Miscompare during the
                             write/read of the configuration register.
                       
2E7-222     D       2E7      Description: Error during the write/read
                             of the memory register.
                       
2E7-223     D       2E7      Description: Miscompare during the
                             write/read of the memory I/O register.
                       
2E7-224     D       2E7      Description: Error reading the PCI
                             configuration register.
    
2E7-225     D       2E7      Description: Adapter POST failed.
2E7-230     D       D50      Description: Arbitration test failed.                               
2E7-231     D       D50      Description: Function could not complete.                             
2E7-232     D       D50      Description: SCSI bus data miscompare.                               
2E7-240     D       2E7      Description: No terminal power.
                              
2E7-301     D       2E7      Description: Configuration open failed for
                             parent bus.  software

2E7-700     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. software
                               
2E7-701     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.  software
                               
2E7-702     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. software
                               
2E7-703     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure.  software
                               
2E7-704     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. software

2E7-705     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter failure. software

2E7-800     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI adapter PTC failure.
                               
2E7-802     G       2E7      Description: Error log analysis indicates
                             a PCI SCSI bus failure.
                               
2EF-101     E       751      Description: Post indicates an adapter failure.
650-xxx     D       650      Description: Disk drive configuration failed.
651-140     D       165      Description: Operator panel display test failed
651-150     D       166      Description: Sensor indicates a fan has failed.
651-151     D       152      Description: Sensor indicates a voltage is
                             outside the normal range.

651-152     D       2E1      Description: Sensor indicates an
                             abnormally high internal temperature.
                             Action: Verify that:
                             1. The room ambient temperature is within
                                the system operating environment.
                             2. There is unrestricted air flow around
                                the system.
                             3. All system covers are closed.
                             4. There are no fan failures.
                             If none of these problems exist, then
                             proceed with Chapter 13. "MAP 0220 Hot Plug
                             FRU Problem Resolution".

651-153     D      152      Description: Sensor indicates a power
                            supply has failed.

651-159     D               Description: Sensor indicates a FRU has
                            failed.to replace the FRU(s) that are identified
                            on the diagnostics problem report screen.

651-160     D      166      Description: Sensor indicates a fan is
                            turning too slowly.

651-161     D      152      Description: Sensor indicates a voltage is
                            outside the normal range.

651-162     D      2E1      Description: Sensor indicates an
                            abnormally high internal temperature.
                            Action: Verify that:
                            1. The room ambient temperature is within
                            the system operating environment.
                            2. There is unrestricted air flow around
                            the system.
                            3. All system covers are closed.
                            4. There are no fan failures.
                            If none of these problems exist, then
                            proceed with Chapter 13. "MAP 0220 Hot Plug
                            FRU Problem Resolution".

651-163    D      152      Description: Sensor indicates a power
                           supply has failed.

651-169    D               Description: Sensor indicates a FRU has
                           failed the FRUs that are identified on the
                           diagnostics problem report screen.

651-170    D               Description: Sensor status not available.
                           Action: Contact your support person.

651-171    D               Description: Sensor status not available
                           Action: Contact your support person.

651-600    G               Description: Uncorrectable memory or
                           unsupported memory.
                           Action: Examine the memory modules and
                           determine if they are supported types. If
                           the modules are supported, then replace the
                           appropriate memory module(s).

651-601   G                Description: Missing or bad memory
                           Action: If the installed memory matches the
                           reported memory size, then replace the
                           memory: otherwise, add the missing memory.

651-602    G      2C5      Description: Bad or missing memory
651-603    G      2C6      Description: Bad or missing memory
651-608    G      D01      Description: Bad L2 Cache
651-609    G      D01      Description: Missing L2 Cache
651-610    G      210      Description: CPU internal error
651-611    G      210      Description: CPU internal cache error
651-612    G      D01      Description: L2 Cache parity or multi-bit ECC error
651-613    G      D01      Description: L2 cache ECC single-bit error
651-614    G      214      Description: Time-out error waiting for memory controller
651-615    G      292      Description: Time-out error waiting for I/O

651-619    G               Description: Error log analysis indicates
                           an error detected by the CPU. The error log
                           indicates the following physical FRU
                           location(s) as the probable cause(s).
                           Action: Use the physical location codes to
                           replace the FRUs that are identified on the
                           diagnostics problem report screen.

651-620    G     2C5       Description: ECC correctable error
                           Action: Use Chapter 14. "MAP 0240: Memory
                           Problem Resolution".

651-621    G     2C6       Description: ECC correctable error
651-622    G     2C5       Description: Correctable error threshold exceeded
651-623    G     2C6       Description: Correctable error threshold exceeded
651-624    G     214       Description: Memory controller internal error

651-625    G     214       Description: Memory Address (Bad address going to memory)
651-626    G     214       Description: Memory Data error (Bad data going to memory)
651-627    G     214       Description: Memory time-out error
651-628    G     210       Description: Processor time-out error

651-629    G               Description: Error log analysis indicates
                           and error detected by the memory
                           controller. The error log indicates the
                           following physical FRU location(s) as the
                           probable cause(s).
                           Action: Use the physical location codes to
                           replace the FRUs that are identified on the
                           diagnostics problem report screen.

651-630    G      307      Description: I/O Expansion Bus Parity Error.
651-631    G      307      Description: I/O Expansion Bus Time-out Error.
651-632    G      306      Description: Internal Device Error.

651-633    G      307      Description: I/O Expansion Unit not in an
                           operating state.

651-634    G      307      Description: Internal Device Error.

651-639    G               Description: Error log analysis indicates
                           an error detected by the I/O. The error log
                           indicates the following physical FRU
                           location(s) as the probable cause(s).
                           Action: Use the physical location codes to
                           replace the FRUs that are identified on the
                           diagnostics problem report screen.
                              
651-640   G        2D5      Description: I/O general bus error.
651-641   G        2D6      Description: Secondary I/O general bus error
651-642   G        2D3      Description: Internal Service Processor memory error

651-643   G        2D3      Description: Internal Service Processor
                            firmware error

651-644   G        2D3      Description: Other internal Service
                            Processor hardware error

651-650   G        E17      Description: ECC correctable error.
651-651   G        E18      Description: ECC correctable error.
651-652   G        300      Description: ECC correctable error.
651-653   G        301      Description: ECC correctable error. 
651-654   G        302      Description: ECC correctable error.
651-655   G        303      Description: ECC correctable error.
651-656   G        304      Description: ECC correctable error.
651-657   G        305      Description: ECC correctable error.
651-660   G        E17      Description: Correctable error threshold exceeded.
651-661   G        E18      Description: Correctable error threshold exceeded.
651-662   G        300      Description: Correctable error threshold exceeded.
651-663   G        301      Description: Correctable error threshold exceeded.
651-664   G        302      Description: Correctable error threshold exceeded.
651-665   G        303      Description: Correctable error threshold exceeded.
651-666   G        304      Description: Correctable error threshold exceeded.
651-667   G        305      Description: Correctable error threshold exceeded.
651-670   G        E17      Description: Bad or missing memory.
651-671   G        E18      Description: Bad or missing memory.
651-672   G        300      Description: Bad or missing memory.
651-673   G        301      Description: Bad or missing memory.
651-674   G        302      Description: Bad or missing memory.
651-675   G        303      Description: Bad or missing memory.
651-676   G        304      Description: Bad or missing memory.                               
651-677   G        305      Description: Bad or missing memory.
651-710   G        214      Description: Address/Data parity error on
                            Processor bus

651-711   G        214      Description: Address/Data parity error on
                            Processor bus

651-712   G        214      Description: Address/Data parity error on
                            Processor bus

651-713   G        214      Description: Transfer error on Processor bus
651-714   G        214      Description: Transfer error on Processor bus
651-715   G        214      Description: Transfer error on Processor bus
651-720   G        2C5      Description: Uncorrectable Memory Error
651-721   G        2C6      Description: Uncorrectable Memory Error                         
651-722   G        210      Description: Processor bus parity error  
651-723   G        210      Description: Processor bus parity error
651-724   G        292      Description: I/O Host Bridge time-out error
651-725   G        292      Description: I/O Host Bridge address/data parity error                      
651-730   G                 Description: I/O error on the ISA bus.

651-731   G       2C8      Description: Intermediate or System Bus
                           Address Parity Error.

651-732   G       2C8      Description: Intermediate or System Bus
                           Data Parity Error.
                    
651-733     G     214      Description: Intermediate or System Bus
                           Address Parity Error.

651-734     G     214      Description: Intermediate or System Bus
                           Data Parity Error.

651-735     G     2D2      Description: Intermediate or System Bus
                           Time-out Error.

651-736     G     2D2      Description: Intermediate or System Bus
                           Time-out Error.

651-740     G     2D3      Description: Time-out on communication
                           response from Service Processor

651-741     G     2D3      Description: Service Processor error
                           accessing special registers

651-742     G     2D3      Description: Service Processor reports
                           unknown communication error

651-743     G     2D7      Description: Service Processor error
                           accessing Vital Product Data EEPROM

651-744     G     165      Description: Service Processor error
                           accessing Operator Panel

651-745     G     2D9      Description: Service Processor error
                           accessing Power Controller

651-746     G     2E0      Description: Service Processor error
                           accessing Fan Sensor

651-747     G     2E1      Description: Service Processor error
                           accessing Thermal Sensor

651-748     G     2E2      Description: Service Processor error
                            accessing Voltage Sensor
                      
651-749     G     2E3      Description: Service Processor error
                           accessing Serial Port     2D4

651-750     G     814      Description: Service Processor error
                           accessing NVRAM          2D4

651-751     G     817      Description: Service Processor error
                           accessing Real-Time Clock/Time-of-Day Clock
                      
651-752     G     2E4      Description: Service Processor error
                           accessing JTAG/COP controller/hardware

651-753     G    151      Description: Service Processor detects
                          loss of voltage from the Time-of-Day Clock
                 2D4      backup battery

651-760    G    software    Description: Service Processor caused a
                            reboot of the system due to a surveillance
                 hardware   time-out.
                            Action: A surveillance time-out is caused
                            by lack of response from the operating
                            system. The most likely cause is a software
                            or operating system failure. Verify that
                            the problem is not related to hardware by
                            running diagnostics, in Problem
                            Determination Mode, on all resources which
                            have not already been run. Also, the system
                            administrator should look for other
                            symptoms that would indicate a software or
                            operating system problem. Contact the
                            software support structure for assistance
                            in needed.

651-770    G      2C8      Description: Intermediate or System Bus
                           Address Parity Error. 292  306

651-771   G       2C8      Description: Intermediate or System Bus
                           Data Parity Error.   292      306

651-772   G       2D2      Description: Intermediate or System Bus
                           Time-out Error.   292    306

651-773   G       227      Description: Intermediate or System Bus
                           Data Parity Error.

651-780   G       E17      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  2C7      Problem Resolution".  214

651-781   G       E18      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  2C7      Problem Resolution".     214

651-782   G       300      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-783   G       301      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-784   G       302      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-785   G       303      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-786   G       304      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-787   G       305      Description: Uncorrectable Memory Error.
                           Action: Use Chapter 14. "MAP 0240: Memory
                  214      Problem Resolution".

651-800   G       166      Description: Fan is turning slower than
                           expected       2E0
                               
651-801   G       166      Description: Over voltage condition was
                           detected 2E0      
                           Action: Verify the following:
                           * nothing is obstructing the fan rotation
                           * the fan power connection is tight
                           * the fan speed sensing cable is tight
                           If the fan still is not turning replace the
                           fan. If the fan is turning, replace the fan
                           sensor FRU.

651-810     G     152     Description: Over voltage condition was  detected
                  2E2     Action: Verify that all DC voltages are
                          within specifications. If all of the
                          voltages are within specifications, replace
                          the voltage sensor FRU, otherwise replace
                          the power supply FRU.

651-811     G     152     Description: Under voltage condition was detected
                  2E2     Action: Verify that all DC voltages are
                          within specifications. If all of the
                          voltages are within specifications, replace
                          the voltage sensor FRU, otherwise replace
                          the power supply FRU.

651-812    G     152      Description: System shutdown due to:
                          1. Loss of AC power
                          2. Power button was pushed without proper
                          system shutdown
                          3. Power supply failure
                          Action: If reasons 1 and 2 can be ruled out
                          than replace the power supply FRU.

651-813     G             Description: System shutdown due to loss
                          of AC Power to the site.
                          Action: System resumed normal operation, no
                          action required.

651-814    G     152      Description: CEC Rack shutdown due to one
                          of the following:
                          1. Loss of AC power to the CEC Rack
                          2. Open or disconnected SPCN cable
                          between racks
                          3. AC module, Bulk power, regulator or
                          SPCN card failure.
                          Action: If 1 and 2 can be ruled out and the
                          problem can be recreated, try the power
                          supply related FRUs one at a time to
                          isolate the problem.

651-815     G   287      Description: I/O Rack shutdown due to one
                         of the following: 
                289      1. Loss of AC power to the I/O Rack
                         2. Open or disconnected SPCN cable
                            between racks
                         3. Power supply failure
                          Action: If 1 and 2 can be ruled out, then
                          replace the power supply FRU.

651-816    G    287      Description: Power fault due to internal
                         power supply failure.

651-817    G    289      Description: Power fault due to internal
                         power supply failure.

651-818    G             Description: Power fault due to manual
                         activation of power-off request.
                         Action: Resume normal operation.

651-820    G    2E1      Description: An over temperature condition
                         was detected
                         Action: Verify the following:
                         * the room ambient temperature is within
                         the system operating environment
                         * there is unrestricted air flow around
                         the system
                         * all system covers are closed
                         If all conditions are met, then replace the
                         temperature sensor FRU.

651-821   G     2E1      Description: System shutdown due to an
                         over maximum temperature condition being reached.
                         Action: Verify the following:
                         * The room ambient temperature is within
                         the system operating environment.
                         * There is unrestricted air flow around
                         the system.
                         * All system covers are closed.
                         If all conditions are met, then replace the
                         temperature sensor FRU.

651-822   G     166      Description: System shutdown due to over
                         temperature condition and fan failure. Use
                2E1      the physical FRU location(s) as the
                         probable cause(s).
                         Action: Use the physical location codes to
                         replace the FRUs that are identified on the
                         diagnostics problem report screen.

651-830   G     166      Description: Sensor detected a fan failure.

                2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                         FRU Problem Resolution".

651-831   G     152      Description: Sensor detected a voltage
                         outside of the normal range.
                2E2      Action: Use MAP 1520.

651-832   G     2E1      Description: Sensor detected an abnormally
                         high internal temperature.
                         Action: Verify that:
                         1. The room ambient temperature is within
                            the system operating environment.
                         2. There is unrestricted air flow around
                            the system.
                         3. All system covers are closed.
                         4. There are no fan failures.
                           If none of these problems exist, then
                           proceed with Chapter 13. "MAP 0220 Hot Plug
                           FRU Problem Resolution".

651-833   G    152      Description: Sensor detected a power
                        supply failure.
               E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                        FRU Problem Resolution".

651-839   G             Description: Sensor detected a FRU that
                        has failed.
                        Action: Use the physical location code(s)
                        to replace the FRU(s) that are identified
                        on the diagnostics problem report screen.

651-840   G    166      Description: Sensor detected a fan failure.
               2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                        FRU Problem Resolution".

651-841   G    152      Description: Sensor detected a voltage
                        outside of the normal range.
               2E2      Action: Use MAP 1520.

651-842   G    2E1      Description: Sensor detected an abnormally
                        high internal temperature.
                        Action: Verify that:
                        1. The room ambient temperature is within
                        the system operating environment.
                        2. There is unrestricted air flow around
                        the system.
                        3. All system covers are closed.
                        4. There are no fan failures.
                        If none of these problems exist, then
                        proceed with Chapter 13. "MAP 0220 Hot Plug
                        FRU Problem Resolution".

651-843   G    152      Description: Sensor detected a power
                        supply failure.
               E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                        FRU Problem Resolution".

651-849   G             Description: Sensor detected a FRU that
                        has failed.
                        Action: Use the physical location code(s)
                        to replace the FRU(s) that are identified
                        on the diagnostics problem report screen.

651-88x   G             Description: The CEC or SPCN reported an error.
                        Action: If reference and location codes
                        were reported with this SRN, refer to this
                        system unit's system service guide with the
                        reference and location codes for the
                        necessary repair action. If the reference
                        and location codes were NOT reported, then
                        run Diagnostics in Problem Determination
                        mode and record and report the reference
                        and location codes for this SRN.

651-89x   G             Description: The CEC or SPCN reported an error.
                        Action: Refer to the this system unit's
                        system service guide, with the reference
                        and location codes, for the necessary
                        repair action. If the reference and
                        location codes were NOT reported, then run
                        Advanced Diagnostics in Problem
                        Determination mode and record and report
                        the reference and location codes for this SRN
                           

652-600   G             Description: A non-critical error has been
                        detected and corrected: Uncorrectable
                        memory or unsupported memory.
                        Action: Schedule deferred maintenance.
                        Examine the memory modules and determine if
                        they are supported types. If the modules
                        are supported, then replace the appropriate
                        memory module(s).

652-610  G    210      Description: A non-critical error has been
                       detected and corrected: CPU internal error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-611  G    210      Description: A non-critical error has been
                       detected and corrected: CPU internal cache  error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution"

652-612  G     D01      Description: A non-critical error has been
                        detected and corrected: L2 cache parity or
                        multi-bit ECC error.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-613   G    D01      Description: A non-critical error has been
                        detected and corrected: L2 cache ECC
                        single-bit error.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution"

652-622   G    2C5      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-623   G    2C6      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-630   G    307      Description: A non-critical error has been
                        detected and corrected: I/O Expansion Bus
                        Parity Error.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-631   G    307      Description: A non-critical error has been
                        detected and corrected: I/O Expansion Bus
                        Time-out Error.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-632   G    306      Description: A non-critical error has been
                        detected and corrected: I/O Expansion Bus
               307      Connection Failure.
                        Action: Schedule deferred maintenance. Use
               308      Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-633  G     307      Description: A non-critical error has been
                        detected and corrected: I/O Expansion Unit
               306      not in an operating state.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-634  G     307      Description: A non-critical error has been
                        detected and corrected: Internal Device Error.
                        Action: Schedule deferred maintenance. Use
                        Chapter 12. "MAP 0210: General Problem
                        Resolution".

652-660  G     E17      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-661  G     E18      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-662  G     300      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-663  G     301      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-664  G     302      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-665  G     303      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-666  G     304      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-667  G     305      Description: A non-critical error has been
                        detected and corrected: Correctable error
                        threshold exceeded.
                        Action: Schedule deferred maintenance. Use
                        Chapter 14. "MAP 0240: Memory Problem
                        Resolution".

652-731 G     2C8      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Address Parity Error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-732  G    2C8      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Data Parity Error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-733  G    214      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              2C8      System Bus Address Parity Error.
                       Action: Schedule deferred maintenance. Use
              292      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-734  G    214      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              2C8      System Bus Data Parity Error.
                       Action: Schedule deferred maintenance. Use
              292      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-735  G    2D2      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Time-out Error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-736  G    2D2      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Time-out Error.
                       Action: Schedule deferred maintenance. Use
              214      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-770  G    2C8      Description: A non-critical error has been
                       detected and corrected: Intermediate System
              292      Bus Address Parity Error.
                       Action: Schedule deferred maintenance. Use
              306      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-771  G    2C8      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Data Parity Error.
                       Action: Schedule deferred maintenance. Use
              306      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-772  G    2D2      Description: A non-critical error has been
                       detected and corrected: Intermediate or
              292      System Bus Time-out Error.
                       Action: Schedule deferred maintenance. Use
              306      Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-773  G    227      Description: A non-critical error has been
                       detected and corrected. Intermediate or
                       System Bus Data Parity Error.
                       Action: Schedule deferred maintenance. Use
                       Chapter 12. "MAP 0210: General Problem
                       Resolution".

652-810  G    152      Description: Non-critical power problem,
                       loss of redundant supply. Use the physical
                       FRU location(s) as the probable cause(s).
                       Action: Schedule maintenance. Use the
                       physical location codes to replace the FRUs
                       that are identified on the diagnostics
                       problem report screen.

652-820  G    166      Description: Non-critical cooling problem,
                       loss of redundant fan. Use the physical FRU
                       location(s) as the probable cause(s).
                       Action: Schedule maintenance. Use the
                       physical location codes to replace the FRUs
                       that are identified on the diagnostics
                       problem report screen.

652-830  G    166      Description: Sensor detected a redundant
                       fan failure.
              2E0      Action: Use Chapter 13. "MAP 0220 Hot Plug
                       FRU Problem Resolution".

652-833  G    152      Description: Sensor detected a redundant
                       power supply failure.
              E19      Action: Use Chapter 13. "MAP 0220 Hot Plug
                       FRU Problem Resolution".

652-839  G             Description: Sensor detected a redundant
                       FRU failure.
                       Action: Use the physical location code(s)
                       to replace the FRU(s) that are identified
                       on the diagnostics problem report screen.

652-88x  G             Description: The CEC or SPCN reported a
                       non-critical error.
                       Action: Schedule deferred maintenance. If
                       reference and location codes were reported
                       with this SRN, refer to this system unit's
                       system service guide with the reference and
                       location codes for the necessary repair
                       action. If the reference and location codes
                       were NOT reported, then run Diagnostics in
                       Problem Determination mode and record and
                       report the reference and location codes for
                       this SRN.

652-89x  G             Description: The CEC or SPCN reported a
                       non-critical error.
                       Action: Schedule deferred maintenance.
                       Refer to the this system unit's system
                       service guide, with the reference and
                       location codes, for the necessary repair
                       action. If the reference and location codes
                       were NOT reported, then run Advanced
                       Diagnostics in Problem Determination mode
                       and record and report the reference and
                       location codes for this SRN.

664-098  J    664      Description: IPLROS detected a problem
                       with the CD-ROM drive      B88
                     
664-099  J    664      Description: IPLROS detected a problem
                       with the CD-ROM drive

664-111   D   664      Description: Unable to reserve device.
664-112   D   664      Description: Unable to do configuration.
664-113   D   664      Description: Unable to open the device driver.
664-121   D   664      Description: The CD-ROM drive indicates an error.
664-122   D   664      Description: The CD-ROM drive indicates an error.
664-123   D   664      Description: The CD-ROM drive indicates an error.
664-125   D   664      Description: The CD-ROM drive indicates an error.
664-126   D   664      Description: The CD-ROM drive indicates an error.
664-127   D   664      Description: The CD-ROM drive indicates an error.
664-128   D   664      Description: The CD-ROM drive indicates an error.
664-129   D   664      Description: The CD-ROM drive indicates an error.
664-150   D  Media     Description: A media error was detected.
664-151   D   664      Description: A command timeout was detected.
664-152   D   664      Description: A command reservation
                       conflict was detected.

664-162   D   664      Description: The CD-ROM drive indicates an error.
664-171   D   664      Description: Unable to reserve device.
664-172   D   664      Description: Unable to do configuration.
664-173   D   664      Description: Unable to open device driver.
664-175   D   664      Description: The CD-ROM drive indicates an error.
664-198   D   664      Description: Undefined error detected.
664-199   D   664      Description: Undefined error detected.
664-211   D   664      Description: The LED test failed.
664-281   D   664      Description: No tone during audio test.
664-301   G   664      Description: Errors found during ELA.
664-302   G   664      Description: Errors found during ELA.
669-201   D   669      Description: Configuration register test failure
669-202   D   669      Description: I/O register test failure
669-203   D   669      Description: Adapter memory test failure
669-204   D   669      Description: Adapter initialization test failure
669-205   D   669      Description: Internal loopback test failure
669-206   D   669      Description: External loopback test failure
                      
669-701   G   669      Description: Error log analysis indicates
                       that this device failed to initialize
                       because it is not the IBM version of the
                       adapter. AIX cannot configure the non-IBM
                       version of this adapter
  
669-702   G   669      Description: Error Log Analysis indicates
                       that this device failed to initialize due
              221      to a problem with the EEPROM on the adapter.

669-703   G   669      Description: Error Log Analysis indicates
                       that this device has failed to initialize
              221      due to a self-test failure.

669-704   D   669      Description: Error Log Analysis indicates
                       that this device has failed to initialize
              221      due to firmware download error. The
                       microcode seems to be properly installed.

674-101   D   674      Description: Artic960 PCI Adapter Central
                       Processing Unit (CPU) test failure.
              C94      Action: Use MAP 0210.

674-102   D   674      Description: Artic960 PCI Adapter Timer test failure.
674-103   D   674      Description: Artic960 PCI Adapter Bus Interface test failure.

674-104   D   C94      Description: Artic960 PCI Adapter Dynamic
                       Random Access Memory (DRAM) test failure.

674-105   D   674      Description: Artic960 PCI Adapter Memory
                       Protection test failure.

674-106   D   674      Description: Artic960 PCI Adapter Debug
                       Port test failure.
  
674-107   D   C95      Description: Interface board wrap test failure.
  
674-110   D   C94      Description: Artic960 PCI Adapter Download
                       Diagnostics test failure.

674-123   D   C95      Description: Interface board non-wrap test failure.

674-150   D   674      Description: Device configuration failure.
                       software   Action: Use MAP 0210.

674-151   D   674      Description: Device driver indicates a
                       hardware failure. software   227
                               
674-152   D   674      Description: Failure and error in
                       determining which type of Artic960 PCI
                       Adapter.    Action: Use MAP 0210.
  
674-153   D   674      Description: Error log analysis indicates
                       a Artic960 PCI Adapter failure.
              227      Action: Use ERRPT command to check error
                       log.    C94 software

674-154   D   C94      Description: Artic960 PCI Adapter
                       initialization failure.
                      
674-155   D   674      Description: Artic960 PCI Adapter
                       initialization failure.

674-156   D   C95      Description: Artic960 PCI Adapter
                       initialization failure.

674-157   D   C98      Description: Cable wrap test failure.

675-101   D   675      Description: Artic960Hx Adapter Central
                       Processing Unit (CPU) test failure.

675-102   D   675      Description: Artic960Hx Adapter Timer test failure.

675-103   D   675      Description: Artic960Hx Adapter Bus
                       Interface test failure.

675-104   D   C94      Description: Artic960Hx Adapter Dynamic
                       Random Access Memory (DRAM) test failure.

675-105   D   675      Description: Artic960Hx Adapter Memory
                       Protection test failure.
  
675-106   D   675      Description: Artic960Hx Adapter Debug Port test failure.
  
675-107   D   C95      Description: Interface board wrap test failure.
          
675-110   D   C94      Description: Artic960Hx Adapter Download
                       Diagnostics test failure.

675-123   D   C95      Description: Interface board non-wrap test failure.
 
675-150   D   675      Description: Device configuration failure.
                       software   Action: Use MAP 0210.       227

675-151   D   675      Description: Device driver indicates a  hardware failure.
                       software   Action: Use MAP 0210. 227
                    
675-152   D   675      Description: Failure and error in
                       determining which type of Artic960Hx
                       Adapter.    Action: Use MAP 0210.
  
675-153   D   675      Description: Error log analysis indicates
                       a Artic960Hx Adapter failure.
              227      Action: Use ERRPT command to check error log.  C94software
                               
675-154   D   C94      Description: Artic960Hx Adapter
                       initialization failure.
                      
675-155   D   675      Description: Artic960Hx Adapter
                       initialization failure.

675-156   D   C95      Description: Artic960Hx Adapter
                       initialization failure.
  
675-157   D   C98      Description: Cable wrap test failure.
677-201   D   677      Description: Configuration Register test failure
677-202   D   677      Description: Reset test failure                  
677-203   D   677      Description: Register test failure                
677-204   D   677      Description: SRAM test failure             
677-205   D   677      Description: Interrupt test failure             
677-206   D   677      Description: PCI Loop Back test failure
677-207   D   677      Description: Internal Loop Back test failure 221
677-208   D   677      Description: External Loop Back test failure 221                               
677-209   D   677      Description: Hub Loop Back test failure xxx
677-301   D   677      Description: I/O Error on Read/Write Operation 221 Software
                              
677-401   F   C24      Description: Unisolated Loop Back test failure
              xxx      Action: Run diagnostics again utilizing the
                       wrap plug.     677      221

677-701   G   677      Description: Error log analysis indicates
                       that an error has occurred with the 221  adapter.

677-702   G  Microcode   Description: Error log analysis indicates
                         that an adapter microcode error has  677  occurred
                     
678-098   J   678     Description: Tape drive indicates an  error.
678-099   J   678     Description: Tape drive not found.    B88

678-101   D   678     Description: Timeout while attempting to
                      communicate with SCSI device.
                                                            
678-102   D   678      Description: The SCSI device indicates busy.
678-103   D   678      Description: The SCSI device indicates a
                       reservation conflict.
              
678-104   D   678      Description: The SCSI device indicates a
                       check condition.

678-105   D   678      Description: An error is detected in
                       request sense data.
              
678-107   D   678      Description: Sense data from the SCSI
                       drive has unexpected data.
              
678-110   D   678      Description: The Reserve command failed.
              
678-111   D   678      Description: Invalid condition from the
                       drive after a reserve.
              
678-112   D   678      Description: The write protect sensor test failed.
              
678-113   D   678      Description: Invalid condition from drive
                       after a request sense.
              
678-114   D   678      Description: Timeout while attempting to
                       communicate with the SCSI device.                       

678-120   D   678      Description: The Inquiry command failed.
678-130   D   678      Description: The Load command failed.media
678-134   D   B88      Description: The adapter failed to  configure. software
678-135   D   678      Description: The Unload command failed. media
678-140   D   678      Description: The Mode Select command failed.
678-150   D   678      Description: The Test Unit Ready command failed.  media
678-160   D   678      Description: The Send Diagnostic command failed.   media
678-161   D   678      Description: Invalid condition from the
                       drive after a reserve.   B88
              
678-163   D   678     Description: Invalid condition from the
                      drive after a request sense.  B88
              
678-164   D   678     Description: Timeout while attempting to
                      communicate with the SCSI device.  B88
                               
678-165   D   678      Description: Write, Read and Compare Test failed.  B88
678-166   D   678      Description: Unable to configure the device. B88 software
678-167   D   678      Description: An unexpected SCSI error occurred.  B88
678-168   D   B88      Description: The adapter failed to configure.  software
678-169   D   678      Description: The send diagnostic command failed.  media
678-170   D   678      Description: The Read, Write and Compare test failed.B88 media
678-180   D   678      Description: The Load command failed.  media
678-185   D   678      Description: The Unload command failed. media
678-190   D   678      Description: The Mode Select command  failed.
678-200   D   678      Description: The Test Unit Ready command failed.  media
678-201   G   678      Description: Error diagnosed from error log analysis.   B88
678-210   D   678      Description: The device configuration failed. B88
678-211   D   678      Description: The device open failed.
678-220   D   678      Description: The Release command failed.
678-230   D   678      Description: The Request Sense command failed.
678-240   D   678      Description: The Openx command failed.
678-260   D   678      Description: The device configuration  failed.
678-261   D   678      Description: The device open failed.
678-300   D   678      Description: The device configuration failed. software
678-310   D   B88      Description: SCSI adapter configuration failed. software
678-320   G   678      Description: Error log analysis indicates a failure. media
              
678-411   D       678      Description: A reservation conflict
     to   D       678      occurred.
678-423           B88      software
  
678-511   D       678      Description: The drive returned bad or
   to     D       678      non-extended sense data.
678-523           B88

678-611   D       678     Description: An adapter or bus I/O error
  to      D       678     occurred.
678-623           B88     software

678-711   D       678     Description: A device timeout error
  to      D       678     occurred.
678-723           B88     software

679-098   J       679   Description: The disk drive indicates an error.
679-099   J       679   Description: The disk drive not found.
679-102   D       679   Description: An unrecoverable media error occurred.
679-104   D       679   Description: The motor failed to restart.
679-105   D       679   Description: The drive did not become ready.
679-106   D       679   Description: The electronics card test failed.
679-108   D       679   Description: The bus test failed.
679-110   D       679   Description: The media format is corrupted.
679-112   D       679   Description: The diagnostic test failed.
679-114   D       679   Description: An unrecoverable hardware error.

679-116   D             Description: A protocol error.
                        Action: Check the levels of the device,
                        adapter, diagnostic software, and
                        application software to be sure they are
                        all compatible. If you do not find a
                        problem, call your support person.

679-117    D    679     Description: A write protect error occurred.
679-118    D    679     Description: A SCSI command time-out occurred. B88
679-120    D    679     Description: A SCSI busy or command error.
679-122    D    679     Description: A SCSI reservation conflict error.
679-124    D    679     Description: A SCSI check condition error occurred.
679-126    D    679     Description: A software error was caused a hardware failure.
                     
679-128    G    679     Description: The error log analysis
                        indicates a hardware failure.
              
679-129    G    D50    Description: Error log analysis indicates
                       a SCSI bus problem.  B88  software
                               
679-130    G    679    Description: Error log analysis indicates
                       a problem reported by the disk drive's self
                       monitoring function.
  
679-132    D    679     Description: A disk drive hardware error occurred.
679-134    D    B88     Description: The adapter failed to configure. software
679-135    D    679     Description: The device failed to configure. software
679-136    D    679     Description: The certify operation failed to save

679-137    D    679     Description: Unit attention condition has
                        occurred on the Send Diagnostic command.
                                
681-098   J     681    Description: The disk drive indicates an error.
681-099   J     681    Description: The disk drive not found.  B88
681-102   D     681    Description: An unrecoverable media error occurred.
681-104   D     681    Description: The motor failed to restart.
681-105   D     681    Description: The drive did not become ready.
681-106   D     681    Description: The electronics card test failed.
681-108   D     681    Description: The bus test failed.
681-110   D     681    Description: The media format is corrupted.
681-112   D     681    Description: The diagnostic test failed.
681-114   D     681    Description: An unrecoverable hardware error.

681-116   D            Description: A protocol error.
                       Action: Check the levels of the device,
                       adapter, diagnostic software, and
                       application software to be sure they are
                       all compatible. If you do not find a
                       problem, call your support person.

681-117   D    681      Description: A write protect error occurred.
681-118   D    681      Description: A SCSI command time-out occurred. B88
681-120   D    681      Description: A SCSI busy or command error.
681-122   D    681      Description: A SCSI reservation conflict error.
681-124   D    681      Description: A SCSI check condition error occurred.

681-126   D    681      Description: A software error was caused
                        by a hardware failure.     B88
                               
681-128   G    681      Description: The error log analysis
                        indicates a hardware failure.
  
681-129   G    D50      Description: Error log analysis indicates
                        a SCSI bus problem.  software
                               
681-130   G    681      Description: Error log analysis indicates
                        a problem reported by the disk drive's self
                        monitoring function.

681-132   D    681      Description: A disk drive hardware error occurred.
681-134   D    B88      Description: The adapter failed to configure.software
681-135   D    681      Description: The device failed to configure. software
681-136   D    681      Description: The certify operation failed.

681-137   D        681      Description: Unit attention condition has
                            occurred on the Send Diagnostic command.

682-098   J        682      Description: IPLROS detected a problem
                            with the CD-ROM drive B88    221

682-099   J        682      Description: IPLROS detected a problem
                            with the CD-ROM drive   B88

682-111   D        682      Description: Unable to reserve device. B88
682-112   D        682      Description: Unable to do configuration. B88
682-113   D        682      Description: Unable to open the device driver.    B88
682-121   D        682      Description: The CD-ROM drive indicates an error.
682-122   D        682      Description: The CD-ROM drive indicates an error.
682-123   D        682      Description: The CD-ROM drive indicates an error.
682-125   D        682      Description: The CD-ROM drive indicates an error.   B88
682-126   D        682      Description: The CD-ROM drive indicates an error.
682-127   D        682      Description: The CD-ROM drive indicates an error.
682-128   D        682      Description: The CD-ROM drive indicates an error.
682-129   D        682      Description: The CD-ROM drive indicates an error.
682-150   D       Media     Description: A media error was detected. 682
682-151   D        682      Description: A command timeout was detected. D88
682-152   D        682      Description: A command reservation conflict was detected.
682-162   D        682      Description: The CD-ROM drive indicates an error.
682-171   D        682      Description: Unable to reserve device.
682-172   D        682      Description: Unable to do configuration.
682-173   D        682      Description: Unable to open device driver.
682-175   D        682      Description: The CD-ROM drive indicates an error.
682-198   D        682      Description: Undefined error detected. B88
682-199   D        682      Description: Undefined error detected.
682-211   D        682      Description: The LED test failed.
682-281   D        682      Description: No tone during audio test.
682-301   G        682      Description: Errors found during ELA.
682-302   G        682      Description: Errors found during ELA.    B88
685-001   D        685      Description: RGB_SCREEN_USER_FAIL Monitor/cable
685-040   D        685      Description: STATUS_POLL_TIMEOUT_ERROR monitor/cable
685-041   D        685      Description: CRC_POLL_TIMEOUT_ERROR Monitor/cable
685-060   D     software    Description: SVC_AIDS_INPUT_ERROR 685
685-081   D     software    Description: LOOP_COUNT_WAS_ZERO  685
685-082   D     software    Description: INVALID_TU_NUMBER 685
685-0B0   D     software    Description: ROM test failed  685
685-0B1   D     software    Description: ROM test failed 685
685-0D0   D     software    Description: INTERNAL_ERROR_DATA_SIZE_0  685
685-0D1   D     software    Description: INTERNAL_ERROR_DATA_SIZE_1  685
685-0D2   D     software    Description: INTERNAL_ERROR_DATA_SIZE_2  685
685-0D3   D     software    Description: INTERNAL_ERROR_DATA_SIZE_3 685
685-0D5   D     software    Description: ODM INIT FAILED  685
685-0D6   D     software    Description: ODM_OBJECT_SEARCH_FAILED  685
685-0D8   D     software    Description: ODM_GET_OBJECT_FAILED   685
685-0D9   D     software    Description: ODM_TERM_FAILED  685
685-0DB   D     software    Description: ILLEGAL_RESOLUTION_SPECIFIED
685-0E5   D     software    Description: AIXGSC_MGA_START_INTERRUPT_FAILED     
685-0E6   D     software    Description: AIXGSC_MGA_STOP_INTERRUPT_FAILED 
685-0E7   D     software    Description: MDD_OPEN_BUS_FAILED                  
685-0E8   D     software    Description: MDD_IOCTL_ERROR 685
685-0E9   D     software    Description: OPEN_RCM_ERROR 685
685-0EA   D     software    Description: IOCTL_GSC_HANDLE_FAILED  685
685-0EB   D     software    Description: AIXGSC_MAKE_GP_FAILED 685
685-0EC   D     software    Description: AIXGSC_UNMAKE_GP_FAILED 685
685-0ED   D     software    Description: DEVICE_BUSY_ERROR 685
685-0EE   D     software    Description: AIXGSC_MGA_SET_DISPLAY_FAILED 685
685-100   D        685      Description: REG_32_BIT_PRTN_ERROR Monitor/cable
685-101   D        685      Description: REG_32_BIT_ADDR_UNIQ_ERROR Monitor/cable
685-102   D        685      Description: REG_8_BIT_PTRN_ERROR Monitor/cable
685-103   D        685      Description: REG_8_BIT_ADDR_UNIQ_ERROR Monitor/cable
685-104   D        685      Description: CRTC_REGS_PTRN_ERROR Monitor/cable
685-105   D        685      Description: CRTC_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-106   D        685      Description: CRTCEXT_REGS_PTRN_ERROR Monitor/cable
685-107   D        685      Description: CRTCEXT_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-108   D        685      Description: RAMDAC_REGS_PTRN_ERROR Monitor/cable
685-109   D        685      Description: RAMDAC_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-10A   D        685      Description: PALETTE_REGS_PTRN_ERROR Monitor/cable
685-10B   D        685      Description: PALETTE_REGS_ADDR_UNIQ_ERROR Monitor/cable
685-200   D        685      Description: ROM test failed    227
685-201   D        685      Description: ROM test failed    227
685-202   D        685      Description: ROM test failed   227
685-203   D        685      Description: ROM test failed   227
685-204   D        685      Description: ROM test failed  227
685-205   D        685      Description: ROM test failed    227
685-206   D        685      Description: ROM test failed  227
685-207   D        685      Description: ROM test failed   227
685-208   D        685      Description: ROM test failed   227
685-209   D        685      Description: ROM test failed   227
685-20B   D        685      Description: ROM test failed  227
685-400   D        685      Description: SGRAM_RED_SCREEN_ERROR Monitor/cable
685-401   D        685      Description: SGRAM_GREEN_SCREEN_ERROR Monitor/cable
685-402   D        685      Description: SGRAM_BLUE_SCREEN_ERROR Monitor/cable
685-403   D        685      Description: SGRAM_WHITE_SCREEN_ERROR Monitor/cable
685-404   D        685      Description: SGRAM_INCREMENTING_SCREEN_ERROR Monitor/cable
685-500   D        685      Description: BLIT_TEST_ERROR_640 x 480 Monitor/cable
685-501   D        685      Description: BLIT_TEST_ERROR_800 x 600 Monitor/cable
685-502   D        685      Description: BLIT_TEST_ERROR_1024 x 768 Monitor/cable
685-503   D        685      Description: BLIT_TEST_ERROR_1280 x 1024 Monitor/cable
685-504   D     software    Description: INTERNAL_ERROR_DATA_SIZE_4 685
685-600   D        685      Description: DRAW_TEST_ERROR_640 x 480_A Monitor/cable
685-601   D        685      Description: DRAW_TEST_ERROR_800 x 600_A Monitor/cable
685-602   D        685      Description: DRAW_TEST_ERROR_1024 x 768_A Monitor/cable
685-603   D        685      Description: DRAW_TEST_ERROR_1280 x 1024_A Monitor/cable
685-604   D     software    Description: INTERNAL_ERROR_DATA_SIZE_5  685
685-605   D        685      Description: DRAW_TEST_ERROR_640 x 480_B Monitor/ cable
685-606   D        685      Description: DRAW_TEST_ERROR_800 x 600_B Monitor/cable
685-607   D        685      Description: DRAW_TEST_ERROR_1024 x 768_B Monitor/cable
685-608   D        685      Description: DRAW_TEST_ERROR_1280 x 1024_B Monitor/cable
685-609   D     software    Description: INTERNAL_ERROR_DATA_SIZE_6  685
685-60A   D        685      Description: DRAW_TEST_ERROR_640 x 480_C Monitor/cable
685-60B   D        685      Description: DRAW_TEST_ERROR_800 x 600_C Monitor/cable
685-60C   D        685      Description: DRAW_TEST_ERROR_1024 x 768_C Monitor/cable
685-60D   D        685      Description: DRAW_TEST_ERROR_1280 x 1024_C Monitor/cable
685-60E   D     software    Description: INTERNAL_ERROR_DATA_SIZE_7  685
686-114   D        686      Description: The register verification test failed.
686-124   D        686      Description: The adapter RAM verification test failed.

686-152   D        686      Description: The data wrap communication test failed.
                            Note: The cable could be defective. The
                            cable FRU part number is listed along with
                            the adapter under FFC 686.

686-153   D        686      Description: The modem control line test failed.
686-252   D        686      Description: The data wrap communication test failed.
686-253   D        686      Description: The modem control line test failed.
686-501   D        686      Description: Adapter Reset failed
686-511   D        686      Description: Adapter to host memory test failed(byte tag)
686-512   D        686      Description: Adapter to host memory test failed (word tag)
686-513   D        686      Description: Adapter to host memory test failed (byte pattern)

686-514   D        686      Description: Adapter to host memory test
                            failed (word pattern test)

686-521   D        686      Description: Adapter BIOS POST CPU failed
686-522   D        686      Description: Adapter BIOS POST Checksum failed
686-523   D        686      Description: Adapter BIOS POST Timer failed
686-524   D        686      Description: Adapter BIOS POST RAM failed
686-526   D        686      Description: Adapter BIOS POST Async Ports failed
686-527   D        686      Description: Adapter BIOS Misc. failed
686-528   D        686      Description: Adapter BIOS Reset failed
686-529   D        686      Description: Adapter BIOS Download failed
686-531   D        686      Description: Adapter BIOS Command failed
686-533   D        686      Description: Adapter BIOS Timer test failed
686-534   D        686      Description: Adapter BIOS RAM test failed
686-541   D        686      Description: Port async internal loopback test failed (general)

686-542   D        686      Description: Port async internal loopback
                            test failed (no response from the port)

686-551   D        686      Description: Port async external loopback
                            test failed (general)

686-552   D        686      Description: Port async external loopback
                            test failed (data signals)

686-553   D        686      Description: Port async external loopback
                            test failed (control signals)

686-554   D        686      Description: Port async external loopback
                            test failed (modem signals)

686-555   D        686      Description: Port async external loopback
                            test failed (no response from port)

686-901   D     software    Description: An unexpected error occurred 
                            that can be attributed to software or hardware  686
   to                       Action: Run diagnostics from a source other
686-920                     than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 686; otherwise, suspect a software
                            problem.

686-921   D        686      Description: The adapter failed to
                            configure.    software

686-922   D     software    Description: An unexpected error occurred
                            that can be attributed to software or
   to             686       hardware.
                            Action: Run diagnostics from a source other
686-924                     than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 686; otherwise, suspect a software
                            problem.

686-925   D        686      Description: The adapter failed to
                            configure. software

686-926   D     software    Description: An unexpected error occurred
                            that can be attributed to software or
   to            686        hardware.
                            Action: Run diagnostics from a source other
686-950                     than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 686; otherwise, suspect a software
                            problem.

687-114   D        687      Description: The register verification test failed.
687-124   D        687      Description: The adapter RAM verification test failed.
687-152   D        687      Description: The data wrap communication test failed.
687-153   D        687      Description: The modem control line test failed.
687-252   D        687      Description: The data wrap communication test failed.
687-253   D        687      Description: The modem control line test failed.
687-144   D        687      Description: The sync line test failed.
687-244   D        687      Description: The sync line test failed.
687-501   D        687      Description: Adapter Reset failed
687-502   D        687      Description: Adapter Fuse failed
687-511   D        687      Description: Adapter to host memory test failed (byte tag)
687-512   D        687      Description: Adapter to host memory test
                            failed (word tag test)

687-513   D        687      Description: Adapter to host memory test
                            failed (byte pattern test)

687-514   D        687      Description: Adapter to host memory test
                            failed (word pattern test)

687-521   D        687      Description: Adapter BIOS POST CPU failed
687-522   D        687      Description: Adapter BIOS POST Checksum failed
687-523   D        687      Description: Adapter BIOS POST Timer failed
687-524   D        687      Description: Adapter BIOS POST RAM failed
687-525   D        687      Description: Adapter BIOS POST Sync Line failed
687-527   D        687      Description: Adapter BIOS Misc. failed
687-528   D        687      Description: Adapter BIOS Reset failed
687-529   D        687      Description: Adapter BIOS Download failed
687-531   D        687      Description: Adapter BIOS Command failed
687-533   D        687      Description: Adapter BIOS Timer test failed
687-534   D        687      Description: Adapter BIOS RAM test failed
687-541   D        687      Description: Port sync internal loopback test failed
687-551   D        687      Description: Port sync external loopback test failed
687-600   D        837      Description: 232RAN status test failed
687-700   D        684      Description: 422RAN status test failed

687-901   D     software    Description: An unexpected error occurred
                            that can be attributed to software or
    to             687      hardware.
                            Action: Run diagnostics from a source other
687-920                     than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 687; otherwise, suspect a software problem.

687-921   D     software    Description: The adapter failed to configure. 687

687-922   D     software    Description: An unexpected error occurred
   to                       that can be attributed to software or
687-924            687      hardware.
                            Action: Run diagnostics from a source other
                            than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 687; otherwise, suspect a software problem.

687-925   D        687      Description: The adapter failed to configure. software

687-926   D     software    Description: An unexpected error occurred
                            that can be attributed to software or
   to              687      hardware.
                            Action: Run diagnostics from a source other
687-950                     than from the disk or a network. If the
                            same error occurs or if the original SRN
                            was not obtained from disk or a network
                            based diagnostics, use Chapter 12. "MAP
                            0210: General Problem Resolution" with a
                            FFC of 687; otherwise, suspect a software
                            problem.

689-098    j      689      Description: The disk drive indicates an error. B88
689-099    J      689      Description: The disk drive not found. B88
689-102    D      689      Description: An unrecoverable media error occurred.
689-104    D      689      Description: The motor failed to restart.
689-105    D      689      Description: The drive did not become ready.
689-106    D      689      Description: The electronics card test failed.
689-108    D      689      Description: The bus test failed.
689-110    D      689      Description: The media format is corrupted.
689-112    D      689      Description: The diagnostic test failed.
689-114    D      689      Description: An unrecoverable hardware error.

689-116    D               Description: A protocol error.
                           Action: Check the levels of the device,
                           adapter, diagnostic software, and
                           application software to be sure they are
                           all compatible. If you do not find a
                           problem, call your support person.
 
689-117     D       689    Description: A write protect error occurred.
689-118     D       689    Description: A SCSI command time-out occurred.B88
689-120     D       689    Description: A SCSI busy or command  error.
689-122     D       689    Description: A SCSI reservation conflict error.
689-124     D       689    Description: A SCSI check condition error occurred.
689-126     D       689    Description: A software error was caused by a hardware failure.
689-128     G       689    Description: The error log analysis
                           indicates a hardware failure.
                             
689-129     G       D50    Description: Error log analysis indicates
                           a SCSI bus problem. 689   B88  software
                               
689-130     G       689    Description: Error log analysis indicates
                           a problem reported by the disk drive's self
                           monitoring function.

689-132     D        689   Description: A disk drive hardware error occurred.
689-134     D        B88   Description: The adapter failed to configure.software
689-135     D        689   Description: The device failed to configure. software
689-136     D        689   Description: The certify operation failed save

689-137     D        689   Description: Unit attention condition has
                           occurred on the Send Diagnostic command. B88  D50
                              
690-098     J       689   Description: The disk drive indicates an error. B88
690-099     J       690   Description: The disk drive not found.  B88
690-102     D       690   Description: An unrecoverable media error occurred.
690-104     D       690   Description: The motor failed to restart.
690-105     D       690   Description: The drive did not become ready.
690-106     D       690   Description: The electronics card test failed.
690-108     D       690   Description: The bus test failed.
690-110     D       690   Description: The media format is corrupted.
690-112     D       690   Description: The diagnostic test failed.
690-114     D       690   Description: An unrecoverable hardware error.

690-116     D             Description: A protocol error.
                          Action: Check the levels of the device,
                          adapter, diagnostic software, and
                          application software to be sure they are
                          all compatible. If you do not find a
                          problem, call your support person.
  
690-117     D       690    Description: A write protect error occurred.
690-118     D       690    Description: A SCSI command time-out occurred. B88
690-120     D       690    Description: A SCSI busy or command error.
690-122     D       690    Description: A SCSI reservation conflict error.
690-124     D       690    Description: A SCSI check condition error occurred.

690-126     D       690    Description: A software error was caused
                           by a hardware failure.  B88

690-128     G       690    Description: The error log analysis
                           indicates a hardware failure.
                            
690-129     G        D50   Description: Error log analysis indicates
                           a SCSI bus problem.690 B88 software
                               
690-130     G        690   Description: Error log analysis indicates
                           a problem reported by the disk drive's self
                           monitoring function.
  
690-132     D       690   Description: A disk drive hardware error occurred.
690-134     D       B88   Description: The adapter failed to configure.software
690-135     D       690   Description: The device failed to configure. software
690-136     D       690   Description: The certify operation failed.

690-137     D       690   Description: Unit attention condition has
                          occurred on the Send Diagnostic command.
                     
691-200     D        691      Description: The ATM 25Mbps Adapter open
                              test failed.

691-202     D        691      Description: The ATM 25Mbps Adapter
                              register test failed.

691-203     D        691      Description: The ATM 25Mbps Adapter memory
                              test failed.

691-204     D        691      Description: The ATM 25Mbps Adapter NVRAM
                              test failed.

691-205     D        691      Description: The ATM 25Mbps Adapter
                              interrupt test failed.

691-206     D        691      Description: The ATM 25Mbps Adapter wrap
                              test failed.

691-210     D        691      Description: The ATM 25Mbps Adapter close
                              test failed.

691-220     D        691      Description: The ATM 25Mbps Adapter was
                              not found.
                     227      Action: Re-install the ATM 25Mbps Adapter
                              and re-run the test. If the error
                              continues, use Chapter 12. "MAP 0210:
                              General Problem Resolution".

691-300     D     Wrap Plug   Description: The ATM 25Mbps Adapter wrap
                              test failed.
                      691     Action: Re-install the wrap plug and re-run
                              the test. If the error continues, use
                      227     Chapter 12. "MAP 0210: General Problem
                              Resolution".
 
691-700     G        691      Description: Error log analysis reported a hardware error.
692-110     D        692      Description: The Reserve command failed.
692-120     D        692      Description: The Inquiry command failed.
692-130     D        692      Description: The Load command failed. media
692-135     D        692      Description: The Unload command failed.media
692-140     D        692      Description: The Mode Select command failed.
692-150     D        692      Description: The Test Unit Ready command failed. media
692-160     D        692      Description: The Send Diagnostic command failed.media
692-169     D        692      Description: The send diagnostic command failed.media
692-170     D        692      Description: The Read, Write and Compare test failed.media
692-180     D        692      Description: The Load command failed.  media
692-185     D        692      Description: The Unload command failed. media
692-190     D        692      Description: The Mode Select command failed.
692-200     D        692      Description: The Test Unit Ready command failed.media
692-210     D        692      Description: The device configuration failed.  B88
692-220     D        692      Description: The Release command failed.
692-230     D        692      Description: The Request Sense command failed.
692-240     D        692      Description: The Openx command failed.
692-300     D        692      Description: The device configuration failed.software
692-310     D        B88      Description: SCSI adapter configuration failed.software
692-320     G        692      Description: Error log analysis indicates a failure. media
692-411     D        692      Description: A reservation conflict to occurred.
692-423              B88      software

692-511     D        692      Description: The drive returned bad or
     to                       non-extended sense data.
692-523              B88

692-611     D        692      Description: An adapter or bus I/O error
     to                       occurred.
692-623              B88      software

692-711     D        692      Description: A device timeout error
     to                       occurred.
692-723             B88       software

693-100     D        693      Description: Adapter open failed.   227
693-101     D        693      Description: Adapter config register test failed.
693-102     D        693      Description: Adapter reset failed. 227
693-103     D        693      Description: Adapter I/O register test failed.
693-104     D        693      Description: Adapter microcode download test failed.
693-105     D        693      Description: Adapter internal wrap test failed.227
693-106     D        693      Description: Adapter close failed.   227
697-100     D        697      Description: Charm memory write failure software
697-101     D        697      Description: Charm memory read failure software

697-102     D        697      Description: PCI configuration register
                              write failure software    227

697-103     D        697      Description: Charm software reset failure software
697-104     D        697      Description: Packet memory error software
697-105     D        697      Description: Control memory failure software 227
697-106     D        697      Description: Link-R detected bad parity
697-107     D        697      Description: Suni detected bad parity
697-108     D        697      Description: Suni initialization failure

697-109     D     Wrap Plug   Description: Loss of light detected in Link test
                      697     Action: Check wrap plug installation.

697-10B     D     Wrap Plug   Description: External Loopback failed
                              Action: Check wrap plug installation.
                      
697-10C     D        697      Description: Internal Loopback failed software 227
697-10D     D        697      Description: DMS failed software
697-1FF     D        697      Description: EPROM checksum failed software 227
697-200     D     software    Description: Klog error 697 227
697-201     D     software    Description: ASL error 697    227
697-202     D     software    Description: ODM Initialization error 697 227
697-203     D     software    Description: Diagnostic configuration failure 697 227
697-205     D     software    Description: Error in diag open 697   227
697-206     D     software    Description: Error in releasing adapter 697  227
698-100     D        698      Description: Charm memory write failure software227
698-101     D        698      Description: Charm memory read failure software 
698-102     D        698      Description: PCI configuration register write failure software
698-103     D        698      Description: Charm software reset failure software
698-104     D        698      Description: Packet memory error software 227
698-105     D        698      Description: Control memory failure software 227
698-106     D        698      Description: Link-R detected bad parity
698-107     D        698      Description: Suni detected bad parity
698-108     D        698      Description: Suni initialization failure

698-109     D     Wrap Plug   Description: Loss of light detected inLink test
                      698     Action: Check wrap plug installation.

698-10B     D     Wrap Plug   Description: External Loopback failed
                              Action: Check wrap plug installation. 698

698-10C     D        698      Description: Internal Loopback failed software   227
698-10D     D        698      Description: DMS failed 227   software
698-1FF     D        698      Description: EPROM checksum failed software 227
698-200     D     software    Description: Klog error  698    227
698-201     D     software    Description: ASL error  698   227
698-202     D     software    Description: ODM Initialization error 698 227
698-203     D     software    Description: Diagnostic configuration failure 698  227
698-205     D     software    Description: Error in diag open 698   227
698-206     D     software    Description: Error in releasing adapter
699-100     D        699      Description: An error was found on the adapter
 
699-110     G        699      Description: Error Log analysis indicates
                              a hardware error.

699-120     D        699      Description: Adapter hardware has caused a
                              software failure.

700-102     D        700      Description: 1.1GB single-ended disk drive
     to                       problem.
700-114

700-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

700-117     D        700      Description: A write protect error occurred.
700-118     D        700      Description: A SCSI command time-out.    B88

700-120     D        700      Description: A SCSI error.
     to
700-124
  
700-126     D        700      Description: A software error was caused by a hardware failure.

700-128     G        700      Description: The error log analysis
                              indicates a hardware failure.
  
700-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem. 700 B88  software

700-130     G        700      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

700-132     D        700      Description: A disk drive hardware error occurred.
700-134     D        B88      Description: The adapter failed to configure. software
700-135     D        700      Description: The device failed to configure.software
700-136     D        700      Description: The certify operation failed.

700-137     D        700      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
701-102     D        701      Description: 1.1GB 16-bit single-ended
     to                       disk drive problem.
701-114

701-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

701-117     D        701      Description: A write protect error occurred.
701-118     D        701      Description: A SCSI command time-out.

701-120     D        701      Description: A SCSI error.
     to
701-124
  
701-126     D        701      Description: A software error was caused
                              by a hardware failure.

701-128     G        701      Description: The error log analysis
                              indicates a hardware failure.

701-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.  701 B88  software
                               
701-130     G        701      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

701-132     D        701      Description: A disk drive hardware error occurred.
701-134     D        B88      Description: The adapter failed to configure. software
701-135     D        701      Description: The device failed to configure.software
701-136     D        701      Description: The certify operation failed.

701-137     D        701      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
702-102     D        702      Description: 1.1GB 16-bit differential
     to                       disk drive problem.
702-114

702-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

702-117     D        702      Description: A write protect error occurred.
702-118     D        702      Description: A SCSI command time-out.

702-120     D        702      Description: A SCSI error.
     to
702-124

702-126     D        702      Description: A software error was caused
                              by a hardware failure.

702-128     G        702      Description: The error log analysis
                              indicates a hardware failure.

702-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem. software

702-130     G        702      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

702-132     D        702      Description: A disk drive hardware error occurred.
 
702-134     D        B88      Description: The adapter failed to configure.software
702-135     D        702      Description: The device failed to configure. software
702-136     D        702      Description: The certify operation failed.

702-137     D        702      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
703-102     D        703      Description: 2.2GB single-ended disk drive
     to                       problem.
703-114
 
703-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

703-117     D        703      Description: A write protect error occurred.

703-118     D        703      Description: A SCSI command time-out.

703-120     D        703      Description: A SCSI error.
     to
703-124

703-126     D        703      Description: A software error was caused
                              by a hardware failure.

703-128     G        703      Description: The error log analysis
                              indicates a hardware failure.

703-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.  703 B88  software
                               
703-130     G        703      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

703-132     D        703      Description: A disk drive hardware error occurred.
703-134     D        B88      Description: The adapter failed to configure.Software
703-135     D        703      Description: The device failed to configure. software
703-136     D        703      Description: The certify operation failed.

703-137     D        703      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
704-102     D        704      Description: 2.2GB 16-bit single-ended
     to                       disk drive problem.
704-114

704-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

704-117     D        704      Description: A write protect error occurred.

704-118     D        704      Description: A SCSI command time-out.

704-120     D        704      Description: A SCSI error.
     to
704-124

704-126     D        704      Description: A software error was caused
                              by a hardware failure.

704-128     G        704      Description: The error log analysis
                              indicates a hardware failure.

704-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem. 704 B88 software

704-130     G        704      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

704-132     D        704      Description: A disk drive hardware error occurred.
704-134     D        B88      Description: The adapter failed to configure. software
704-135     D        704      Description: The device failed to configure. B88 software
704-136     D        704      Description: The certify operation failed.

704-137     D        704      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
705-102     D        705      Description: 2.2GB 16-bit differential
     to                       disk drive problem.
705-114

705-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

705-117     D        705      Description: A write protect error occurred.
705-118     D        705      Description: A SCSI command time-out.

705-120     D        705      Description: A SCSI error.
     to
705-124

705-126     D        705      Description: A software error was caused
                              by a hardware failure.

705-128     G        705      Description: The error log analysis
                              indicates a hardware failure.

705-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.

705-130     G        705      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

705-132     D        705      Description: A disk drive hardware error occurred.
705-134     D        B88      Description: The adapter failed to configure. software
705-135     D        705      Description: The device failed to configure.B88 software
705-136     D        705      Description: The certify operation failed.

705-137     D        705      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                     
706-102     D        706      Description: 4.5GB 16-bit single-ended
     to                       disk drive problem
706-114
  
706-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

706-117     D        706      Description: A write protect error occurred.
706-118     D        706      Description: A SCSI command time-out.

706-120     D        706      Description: A SCSI error.
     to
706-124

706-126     D        706      Description: A software error was caused
                              by a hardware failure.

706-128     G        706      Description: The error log analysis
                              indicates a hardware failure.

706-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem. 706  B88 software

706-130     G        706      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

706-132     D        706      Description: A disk drive hardware error occurred.
706-134     D        B88      Description: The adapter failed to configure.software
706-135     D        706      Description: The device failed to configure.B88 software
706-136     D        706      Description: The certify operation failed.

706-137     D        706      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.              

707-102     D        707      Description: Any of the following may have
     to                       occurred: an unrecoverable media error,
707-114                       motor failed to restart, the drive did not
                              become ready, electronics card test failed,
                              bus test failed, media format failed, or
                              diagnostic test failed.

707-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

707-117     D        707      Description: A write protect error occurred.
707-118     D        707      Description: A SCSI command time-out.

707-120     D        707      Description: A SCSI error.
     to
707-124

707-126     D        707      Description: A software error was caused
                              by a hardware failure.
 
707-128     G        707      Description: The error log analysis
                              indicates a hardware failure.

707-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.

707-130     G        707      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

707-132     D        707      Description: A disk drive hardware error occurred.
707-134     D        B88      Description: The adapter failed to configure.software
707-135     D        707      Description: The device failed to configure.B88software
707-136     D        707      Description: The certify operation failed.

707-137     D        707      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
709-101     D        709      Description: Cannot run the test because
                              the device driver detected a hardware error.

709-111     D        709      Description: Could not do the test because
                              the device driver detected a hardware error.
                               
709-112     D        709      Description: Unable to determine the type
                              of adapter from the VPD.

709-113     D        709      Description: The VPD verification test failed.
709-114     D        709      Description: The register verification test failed.
709-115     D        709      Description: The VPD verification test failed.
709-116     D        D57      Description: The 128-port controller line test failed.
709-117     D        684      Diagnostics: Remote Async Node test failed.
709-118     D        837      Description: Remote async node test failed.
709-119     F        709      Description: Sync line termination test failed.

709-151     D        837      Description: Could not perform because the
                              device driver detected a hardware error.

709-152     D        837      Description: The data wrap communication test failed.  
709-153     D        837      Description: The modem control line test failed.
  
709-154     D        684      Diagnostics: Cannot run the test because
                              the device driver detected a hardware error.

709-155     D        684      Diagnostics: The data wrap communications test failed.
                      
709-161     D        266      Description: Could not perform because the
                              device driver detected a hardware error.

709-162     D        266      Description: The data wrap communication test failed.
709-163     D        266      Description: The modem control line test failed.
709-164     D        D06      Description: The data wrap communicationtest failed.

709-171     D        259      Description: Could not perform because the
                              device driver detected a hardware error.

709-172     D        259      Description: The data wrap communication test failed.
709-173     D        259      Description: The modem control line test failed.

709-174     D        263      Description: Cannot run the test because
                              the device driver detected a hardware error.

709-175     D        263      Description: The data wrap communications test failed.

709-181     D        261      Description: Could not perform because the
                              device driver detected a hardware error.

709-182     D        261      Description: The data wrap communication test failed.
709-183     D        261      Description: The modem control line test failed.

709-251     D        709      Description: Could not perform because the
                              device driver detected a hardware error.
                      
709-252     D        709      Description: The data wrap communication test failed.
709-253     D        709      Description: The modem control line test failed.

709-254     D        709      Diagnostics: Cannot run the test because   
                              the device driver detected a hardware error while
                              running the Remote Async Node wrap test.

709-255     D        709      Diagnostics: The data wrap communications
                              test failed while running the Remote Async
                     684      Node wrap test.
                      
709-271     D        709      Description: Could not perform because the
                              device driver detected a hardware error.

709-272     D        709      Description: The data wrap communication test failed.
709-273     D        709      Description: The modem control line test failed.

709-274     D        709      Diagnostics: Cannot run the test because
                              the device driver detected a hardware error while
                              running the Printer/Terminal cable wrap  test.

709-275     D        709      Diagnostics: The data wrap communications
                              test failed while running the
                     684      Printer/Terminal cable wrap test.
                      
709-281     D        709      Description: Could not perform because the
                              device driver detected a hardware error.

709-282     D        709      Description: The data wrap communication test failed.
709-283     D        709      Description: The modem control line test failed.

709-481     D        D56      Description: Could not do the test because
                              the device driver detected a hardware error.

709-482     D        D56      Description: The data wrap communication test failed.
709-483     D        D56      Description: The modem control line test failed.

709-901     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to               709     hardware.
709-920                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 709; otherwise, suspect a software
                              problem.

709-921     D        709      Description: The adapter failed to configure software

709-922     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to               709     hardware.
709-924                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 709; otherwise, suspect a software problem.
  
709-925     D        709      Description: The adapter failed to configure software

709-926     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to              709      hardware.
709-943                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 709; otherwise, suspect a software problem.

721-102     D        721      Description: Unknown SCSI or device error.
     to
721-114

721-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

721-117     D        721      Description: A write protect error occurred.
721-118     D        721      Description: A SCSI command time-out.

721-120     D        721      Description: Unknown SCSI or device error.
     to
721-124
 
721-126     D        721      Description: A software error was caused
                              by a hardware failure.

721-128     G        721      Description: The error log analysis
                              indicates a hardware failure.

721-130     G        721      Description: The error log analysis
                              indicates a hardware failure.

721-132     D        721      Description: A disk drive hardware error occurred.
721-135     D        721      Description: The device failed to configure.B88software
722-xxx     D        722      Description: Unknown disk drive type is failing.
723-xxx     D        723      Description: Unknown CD-ROM type is failing.
724-xxx     D        724      Description: Unknown tape drive failure.

733-110     D        733      Description: The Reserve command failed,
     to                       or the Inquiry command failed.                             
733-120

733-130     D        733      Description: The Load command failed, or
      to                      the Unload command failed. media
733-135

733-140     D        733      Description: The Mode Select command failed.

733-150     D        733      Description: The Test Unit Ready command
     to                       failed, or the Send Diagnostic command
733-169             media     failed.

733-170     D        733      Description: The Read, Write and Compare
                              test failed. media
                   
733-180     D        733      Description: The Load command failed, or
   to                         the Unload command failed.  media
733-185

733-190     D        733      Description: The Mode Select command failed.

733-200     D        733      Description: The Test Unit Ready command media failed.
733-210     D        733      Description: The device configuration failed.
  
733-220     D        733      Description: 140GB 8mm tape drive failed.
     to
733-240

733-300     D        733      Description: The device configuration failed.software
733-310     D        B88      Description: SCSI adapter configuration failed.software
733-320     G        733      Description: Error log analysis indicates a failure.media

733-411     D        733      Description: A reservation conflict
     to                       occurred.
733-423              B88      software

733-511     D        733      Description: The drive returned bad or
     to                       non-extended sense data.
733-523              B88

733-611     D        733      Description: An adapter, device, or bus
     to                       I/O error occurred.
733-723              B88      software

734-111     D        734      Description: Unable to reserve device.                    
734-112     D        734      Description: Unable to do configuration.
734-113     D        734      Description: Unable to open the device driver.
734-121     D        734      Description: The CD-ROM drive indicates an error.
734-122     D        734      Description: The CD-ROM drive indicates an error.
734-123     D        734      Description: The CD-ROM drive indicates an error.
734-125     D        734      Description: The CD-ROM drive indicates an error.
734-126     D        734      Description: The CD-ROM drive indicates an error.
734-127     D        734      Description: The CD-ROM drive indicates an error.
734-128     D        734      Description: The CD-ROM drive indicates an error.
734-129     D        734      Description: The CD-ROM drive indicates an error.
734-150     D       Media     Description: A media error was detected.
734-151     D        734      Description: A command timeout was detected.
734-152     D        734      Description: A command reservation conflict was detected.
734-162     D        734      Description: The CD-ROM drive indicates an error.
734-171     D        734      Description: Unable to reserve device.
734-172     D        734      Description: Unable to do configuration.
734-173     D        734      Description: Unable to open device driver.
734-175     D        734      Description: The CD-ROM drive indicates an error.
734-198     D        734      Description: Undefined error detected.
734-199     D        734      Description: Undefined error detected.
734-211     D        734      Description: The LED test failed.
734-281     D        734      Description: No tone during audio test.
734-301     G        734      Description: Errors found during ELA.
734-302     G        734      Description: Errors found during ELA.
736-101     D        821      Description: An unexpected adapter error occurred.

736-102     D        736      Description: An unexpected device or
                              adapter error occurred.

736-103     D        736      Description: The keyboard reset failed.
736-104     D        736      Description: Unknown keyboard.
736-105     D        736      Description: The keyboard light on test failed.
736-106     D        736      Description: The keyboard light off test failed.
736-201     D        821      Description: An unexpected adapter error occurred.

736-202     D        736      Description: An unexpected device or
                              adapter error occurred.
                               
736-203     D        736      Description: The read keyboard ID test failed.
736-204     D        736      Description: The keyboard layout ID test failed.
736-205     D        736      Description: The keyboard echo test failed.
736-206     D        736      Description: The select scan code set test failed.
736-301     D        821      Description: An unexpected adapter error occurred.

736-302     D        736      Description: An unexpected device or
                              adapter error occurred.

736-303     D        736      Description: An error occurred in turning
                              on the lamps.

736-304     D        736      Description: An error occurred in turning
                              off the lamps.

736-401     D        821      Description: An unexpected adapter error occurred.

736-402     D        736      Description: An unexpected device or
                              adapter error occurred.

736-403     D        736      Description: Unable to recognize the keyboard.
736-404     D        736      Description: The keyboard is failing.
736-701     D        736      Description: Error configuring the device.

736-901     G        821      Description: The error log analysis
                              indicates an adapter failure.
  
736-902     G        736      Description: The error log analysis
                              indicates a device failure.

736-903     G        736      Description: The error log analysis
                              indicates an unknown failure.

741-102     D        741      Description: SCSI disk drive problems.
     to
741-114

741-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

741-117     D        741      Description: A write protect error occurred.
741-118     D        741      Description: A SCSI command timeout.

741-120     D        741      Description: SCSI disk drive problems.
     to
741-124

741-126     D        741      Description: A software error was caused
                              by a hardware failure.

741-128     G        741      Description: The error log analysis
                              indicates a hardware failure.

741-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem. software

741-130     G        741      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

741-132     D        741      Description: A disk drive hardware error occurred.
741-134     D        B88      Description: The adapter failed to configure.software
741-135     D        741      Description: The device failed to configure.B88software

741-137     D        741      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
742-101     D        742      Description: Configuration register test failed
742-102     D        742      Description: I/O register test failed
742-104     D        742      Description: Internal loopback test failed
742-105     D        742      Description: Internal loopback test failed
742-106     D        742      Description: External loopback test failed
742-121     D        D59      Description: Configuration register test failed
742-122     D        D59      Description: I/O register test failed
742-124     D        D59      Description: Internal loopback test failed
742-125     D        D59      Description: Internal loopback test failed
742-126     D        D59      Description: External loopback test failed
742-141     D        D60      Description: Configuration register test failed
742-142     D        D60      Description: I/O register test failed
742-144     D        D60      Description: Internal loopback test failed
742-145     D        D60      Description: Internal loopback test failed
742-160     D        B08      Description: 10Base-T transceiver test failed
742-161     D        B09      Description: 10Base-2 transceiver test failed
742-203     D        742      Description: Device configuration failed software
742-223     D        D59      Description: Device configuration failed software
742-224     D        B08      Description: 10 Base-T transceiver test failed
742-225     D        B09      Description: 10 Base-2 transceiver test failed
742-243     D        D60      Description: Device configuration failed software

742-700     G        742      Description: Error log analysis indicates
                              a hardware problem   software

742-720     G        D59      Description: Error log analysis indicates
                              a hardware problem   software
                               
742-740     G        D60      Description: Error log analysis indicates
                              a hardware problem    software
                               
745-100     D       media     Description: Recovered error.
                              Action: No action required.
                      
745-200     D       media     Description: Drive Not Ready.
                              Action: Install media, refer to the tape
                     745      autoloader service guide.

745-300     D      media     Description: 4mm Tape Auto Loader problem.
     to
745-350             745      Action: Replace media, clean drive, refer
                             to the tape autoloader service guide.

745-400     D        745      Description: General Hardware Failure.
                              Action: Replace media, clean drive, refer
                   magazine   to the tape autoloader service guide. media

745-410     D        745      Description: Internal Hardware Failure
     to                       Action: Replace drive, refer to the tape
745-435             media     autoloader service guide.

745-440     D        745      Description: SCSI Hardware Failure.
                              Action: Replace drive, refer to the tape
                     SCSI     autoloader service guide.  Adapter
                      
745-441     D        745      Description: 4mm Tape Auto Loader problem.
     to
745-443            media     Action: Replace drive, refer to the tape
                             autoloader service guide.

745-444     D        745      Description: Humidity too High
                              Action: Lower humidity, replace media,
                   environ-   refer to the tape autoloader service guide. media
                    
745-445     D       clean     Description: Drive Requires Cleaning
                              Action: Clean drive, replace media, refer
                    media     to the tape autoloader service guide. drive

745-460     D        745      Description: Magazine Movement Failure
     to                       Action: Check magazine and media, clean
745-465            magazine   rollers, refer to the tape autoloader
                              service guide.   media
                               
745-470     D        745      Description: Media Insert/Eject Failure
     to                       Action: Check clean magazine and media,
745-475            magazine   clean rollers, refer to the tape autoloader
                              service guide.   media
                              
745-480     D        745      Description: Drawer Open/Close Failure
     to                       Action: Check magazine and media, refer to
745-485            magazine   the tape autoloader service guide.   media

745-500     D        745      Description: Illegal request to drive
                              Action: Software conflict, refer to the
                    system    tape autoloader service guide.
                     
745-600     D        745      Description: Unit Attention
                              Action: Software conflict, media changed,
                    system    refer to the tape autoloader service guide.
                     
745-700     D        745      Description: Not Writeable
                              Action: Check media for write protect,
                    media     refer to the tape autoloader service guide.
                     
745-800     D        745      Description: Blank Media
                              Action: Check media, refer to the tape
                    media     autoloader service guide.
                     
745-B00     D        745      Description: SCSI Interface Failure
                              Action: Check SCSI interface, refer to the
                    SCSI      tape autoloader service guide. Adapter
                      
745-D00     D        745      Description: Tape Full
                              Action: Check replace media, refer to the
                    media     tape autoloader service guide.
                     
746-212     D        746      Description: FIFO empty bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-213     D        746      Description: FIFO empty bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-214     D        746      Description: FIFO full bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-215     D        746      Description: FIFO full bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-216     D        746      Description: FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-217     D        746      Description: SCSI FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-218     D        746      Description: SCSI FIFO underflow.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-219     D        746      Description: SCSI parity error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-220     D        746      Description: SCSI FIFO flags error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-221     D        746      Description: Miscompare during the
                              write/read of the configuration register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

746-222     D        746      Description: Error during the write/read
                              of the memory register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

746-223     D        746      Description: Miscompare during the
                              write/read of the memory I/O register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

746-224     D        746      Description: Error reading the PCI
                              configuration register.

746-225     D        746      Description: Adapter POST failed.

746-230     D        D50      Description: Arbitration test failed.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     746      Problems Isolation Procedure".
                      
746-231     D        D50      Description: Function could not complete.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     746      Problems Isolation Procedure".
                      
746-232     D        D50      Description: SCSI bus data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     746      Problems Isolation Procedure".

746-240     D        746      Description: No terminal power.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
746-301     D        746      Description: Configuration open failed for
                              parent bus. D50  software
                               
746-700     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
746-701     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure. software
                               
746-702     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
746-703     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
746-704     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
746-705     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
746-800     G        746      Description: Error log analysis indicates
                              a PCI SCSI adapter PTC failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

746-802     G        746      Description: Error log analysis indicates
                              a PCI SCSI bus failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

747-212     D        747      Description: FIFO empty bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
747-213     D        747      Description: FIFO empty bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-214     D        747      Description: FIFO full bit set.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".

747-215     D        747      Description: FIFO full bit clear.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
747-216     D        747      Description: FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-217     D        747      Description: SCSI FIFO data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-218     D        747      Description: SCSI FIFO underflow.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-219     D        747      Description: SCSI parity error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-220     D        747      Description: SCSI FIFO flags error.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                     
747-221     D        747      Description: Miscompare during the
                              write/read of the configuration register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

747-222     D        747      Description: Error during the write/read
                              of the memory register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

747-223     D        747      Description: Miscompare during the
                              write/read of the memory I/O register.
                     221      Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

747-224     D        747      Description: Error reading the PCI
                              configuration register.

747-225     D        747      Description: Adapter POST failed.

747-230     D        D50      Description: Arbitration test failed.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     747      Problems Isolation Procedure".
                     
747-231     D        D50      Description: Function could not complete.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     747      Problems Isolation Procedure".
                     
747-232     D        D50      Description: SCSI bus data miscompare.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     747      Problems Isolation Procedure".

747-240     D        747      Description: No terminal power.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                     221      Problems Isolation Procedure".
                      
747-301     D        747      Description: Configuration open failed 
                              for parent bus.software
                              
747-700     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.   software
                               
747-701     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.   software
                               
747-702     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
747-703     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
747-704     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure.  software
                               
747-705     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter failure. software
                               
747-800     G        747      Description: Error log analysis indicates
                              a PCI SCSI adapter PTC failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

747-802     G        747      Description: Error log analysis indicates
                              a PCI SCSI bus failure.
                              Action: Go to Chapter 7. "MAP 0050: SCSI
                              Problems Isolation Procedure".

749-xxx     D        749      Description: 7331 Model 205 Tape Library.
                              Refer to service documentation for this device.

750-100     D        750      Description: The adapter open test failed.
750-200     D        750      Description: Config register test failed.
750-201     D        750      Description: I/O register test failed.
750-202     D        750      Description: Adapter self-test failed.
750-300     D        256      Description: The connect test failed.
750-301     D        256      Description: Token-ring internal wrap test failure.
750-302     D        256      Description: Token-ring external wrap failure
750-303     D        256      Description: Token-ring initialization test failure
750-400     D        240      Description: The connect test failed.
750-401     D        240      Token-ring internal wrap test failure
750-402     D        240      Token-ring external wrap test failure
750-403     D        240      Token-ring initialization test failure
750-700     G        750      Description: Error Log analysis indicateda hardware failure. 
751-101     D        751      Description: The PCI wrap test failed
751-102     D        751      Description: The POST indicates an adapter failure.
751-103     D        751      Description: The POST indicates an adapter channel failure.
751-104     D       Cable     Description: The POST indicates a defective cable.

751-105     D    Backplane/   Description: The POST indicates a
                              defective backplane or external enclosure.
                    Ext.Encl  Action: If the disk devices are located in
                              an external enclosure, refer to the service
                              documentation for the external enclosure.

751-106     D       Disk      Description: The POST indicates a disk failure.
751-107     D        751      Description: The POST indicates a firmware failure.

751-108     D        751      Description: The NVRAM test indicates an
                              adapter firmware failure.

751-109     D        751      Description: The NVRAM test indicates an
                              adapter failure.

751-110     D       Disk      Description: The disk reported a
                              Predictive Failure Analysis error (PFA).

751-111     D       Disk      Description: The disk drive has been
                              failed by the adapter.

751-112     G       Disk      Description: ELA indicates that the disk
                              reported a irrecoverable equipment error.

751-113     G       Disk      Description: ELA indicates that the disk
                              reported a irrecoverable data error.

757-110     D        757      Description: The Reserve command failed.
757-120     D        757      Description: The Inquiry command failed.
757-130     D        757      Description: The Load command failed. media
757-135     D        757      Description: The Unload command failed.  media
757-140     D        757      Description: The Mode Select command failed.
757-150     D        757      Description: The Test Unit Ready command failed. media
757-160     D        757      Description: The Send Diagnostic command failed. media
757-169     D        757      Description: The send diagnostic command failed. media
757-170     D        757      Description: The Read, Write and Compare test failed. media
757-180     D        757      Description: The Load command failed.  media
757-185     D        757      Description: The Unload command failed.  media
757-190     D        757      Description: The Mode Select command   failed.
757-200     D        757      Description: The Test Unit Ready command failed.media
757-210     D        757      Description: The device configuration failed. 
757-220     D        757      Description: The Release command failed.
757-230     D        757      Description: The Request Sense command failed. 
757-240     D        757      Description: The Openx command failed.
757-300     D        757      Description: The device configuration failed.software
757-310     D        B88      Description: SCSI adapter configuration failed.software
757-320     D        757      Description: Error log analysis indicates a failure. media

757-411     D        757      Description: A reservation conflict
     to                       occurred.
757-423              B88      software

757-511     D        757      Description: The drive returned bad or
     to                       non-extended sense data.
757-523              B88

757-611     D        757      Description: An adapter or bus I/O error
     to                       occurred.
757-623              B88      software

757-711     D        757     Description: A device timeout error
     to                      occurred.
757-723              B88     software

772-098     J       772     Description: Disk drive indicates an error. B88
772-099     J       772     Description: Disk drive not found.
772-102     D       772     Description: An unrecoverable media error.
772-104     D       772     Description: The motor failed to restart.
772-105     D       772     Description: The drive did not become ready.
772-106     D       772     Description: The electronics card test failed.
772-108     D       772     Description: The bus test failed.
772-110     D       772     Description: The media format is corrupted.
772-112     D       772     Description: The diagnostic test failed.
772-114     D       772     Description: An unrecoverable hardware error.

772-116     D               Description: A protocol error.
                            Action: Check the levels of the device,
                            adapter, diagnostic software, and
                            application software to be sure they are
                            all compatible. If you do not find a
                            problem, call your support person.
 
772-117     D       772     Description: A write protect error occurred.
772-118     D       772     Description: A SCSI command time-out.
772-120     D       772     Description: A SCSI busy or command error.
772-122     D       772     Description: A SCSI reservation conflict error.
772-124     D       772     Description: A SCSI check condition error.

772-126     D       772      Description: A software error was caused
                             by a hardware failure.
                               
772-128     G       772       Description: The error log analysis
                              indicates a hardware failure.
                              
772-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.  772 B88 software
                               
772-130     G        772      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

772-132     D        772      Description: A disk drive hardware error occurred.
772-134     D        B88      Description: The adapter failed to configure.software
772-135     D        772      Description: The device failed to configure.software
772-136     D        772      Description: The certify operation failed.

772-137     D        772      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
773-098     J        773      Description: Disk drive indicates an error.
773-099     J        773      Description: Disk drive not found.
773-102     D        773      Description: An unrecoverable media error.
773-104     D        773      Description: The motor failed to restart.
773-105     D        773      Description: The drive did not become ready.
773-106     D        773      Description: The electronics card test failed.
773-108     D        773      Description: The bus test failed.
773-110     D        773      Description: The media format is corrupted.
773-112     D        773      Description: The diagnostic test failed.
773-114     D        773      Description: An unrecoverable hardware error.

773-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.
  
773-117     D        773     Description: A write protect error occurred.
773-118     D        773     Description: A SCSI command time-out.
773-120     D        773     Description: A SCSI busy or command error.
773-122     D        773     Description: A SCSI reservation conflict error.
773-124     D        773     Description: A SCSI check condition error.

773-126     D        773     Description: A software error was caused
                             by a hardware failure.

773-128     G        773     Description: The error log analysis
                             indicates a hardware failure.
                              
773-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.

773-130     G        773      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

773-132     D        773     Description: A disk drive hardware error occurred.
773-134     D        B88     Description: The adapter failed to configure. software
773-135     D        773     Description: The device failed to  configure.software
773-136     D        773     Description: The certify operation failed.

773-137     D        773      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                     
774-098     J        774      Description: Disk drive indicates an error. 
774-099     J        774      Description: Disk drive not found.
774-102     D        774      Description: An unrecoverable media error.
774-104     D        774      Description: The motor failed to restart.
774-105     D        774      Description: The drive did not become ready.
774-106     D        774      Description: The electronics card test failed.
774-108     D        774      Description: The bus test failed.
774-110     D        774      Description: The media format is corrupted.
774-112     D        774      Description: The diagnostic test failed.
774-114     D        774      Description: An unrecoverable hardware error.

774-116     D                  Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.
  
774-117     D       774       Description: A write protect error occurred.
774-118     D       774       Description: A SCSI command time-out. B88
774-120     D       774       Description: A SCSI busy or command error.
774-122     D       774       Description: A SCSI reservation conflict error.
774-124     D       774       Description: A SCSI check condition error.

774-126     D       774       Description: A software error was caused
                              by a hardware failure.
                      
774-128     G       774       Description: The error log analysis
                              indicates a hardware failure.
                               
774-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.774  B88  software
                               
774-130     G        774      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

774-132     D        774     Description: A disk drive hardware error occurred.
774-134     D        B88     Description: The adapter failed to configure.software
774-135     D        774     Description: The device failed to configure.software
774-136     D        774     Description: The certify operation failed.

774-137     D        774     Description: Unit attention condition has
                             occurred on the Send Diagnostic command.
                      
775-001     D        775      Description: "NO" to color panel Monitor
775-002     D        775      Description: "NO" to cursor panel Monitor
775-007     D     Info code   Description: The EMC_SCROLLING_17_H_TEST failed
775-009     D     Info code   Description: The EMC_SCROLLING_21_H_TEST failed
775-064     D        775      Description: TRIO64V+_TIMEOUT
775-101     D        775      Description: Color miscompare
775-102     D        775      Description: Clipping error
775-103     D        775      Description: Rectangle fill test failed
775-128     D     software    Description: MALLOC_ERROR
775-161     D     software    Description: Loop count value in rules file is zero
775-191     D        775      Description: Red screen error
775-193     D        775      Description: Green screen error
775-1FF     D        775      Description: Rectangle fill test failed
775-201     D        775      Description: Color miscompare
775-202     D        775      Description: Clipping error
775-203     D        775      Description: Image transfer across Plane Test failed  
775-211     D     software    Description: INTERNAL_ERROR_DATA_SIZE
775-212     D     software    Description: INTERNAL_ERROR_NO_ACCESS
775-215     D        775      Description: Black screen error
775-217     D        775      Description: 9 x 7 Cross hatch grid failed.
775-233     D     software    Description: OPEN_RCM_ERROR
775-234     D     software    Description: IOCTL_GSC_HANDLE_FAILED
775-235     D     software    Description: AIXGSC_MAKE_GP_FAILED
775-236     D     software    Description: AIXGSC_UNMAKE_GP_FAILED
775-237     D     software    Description: DEVICE_BUSY_ERROR
775-241     D     Info code   Description: The SCROLLING_17_H_TEST failed.
775-263     D     Info code   Description: The EMC_SCROLLING_21_H_TEST failed
775-2FF     D        775      Description: Image transfer across Plane Test failed
  
775-301     D        775      Description: A write of "0x00" to the
                              palette register failed

775-302     D        775      Description: A write of "0x15" to the
                              palette register failed

775-303     D        775      Description: A write of "0x2A" to the
                              palette register failed

775-304     D        775      Description: A write of "0x3F" to the
                              palette register failed

775-305     D        775      Description: The test of the palette
                              registers failed

775-3FF     D        775      Description: The test of the palette
                              registers failed
 
775-401     D        775      Description: Frame buffer base address inconsistent
775-402     D        775      Description: VRAM inaccessible
775-403     D        775      Description: Miscompare found in VRAM
775-404     D        775      Description: The test of the VRAM failed
775-447     D        775      Description: Green screen error
775-449     D        775      Description: Blue Screen error
775-471     D        775      Description: 9 x 7 Cross hatch grid failed.  
775-473     D        775      Description: 11 x 9 Cross hatch grid failed.
775-495     D     Info code   Description: The SCROLLING_17_H_TEST failed.
775-497     D     Info code   Description: The SCROLLING_21_H_TEST failed.
775-4FF     D        775      Description: The test of the VRAM failed
775-501     D        775      Description: Color miscompare
775-502     D        775      Description: Clipping error
775-503     D        775      Description: Direct Frame Buffer test failed
775-5FF     D        775      Description: Direct Frame Buffer test failed
775-601     D        775      Description: Video Stream Register test failed
775-602     D        775      Description: Video Stream hardware test failed
775-6FF     D        775      Description: Video Stream hardware test failed
775-701     D        775      Description: 0 Degree Short Stroke Draw failed
775-702     D        775      Description: 45 Degree Short Stroke Draw failed

775-703     D        775      Description: Blue Screen error, or 90
                              Degree Short Stroke Draw failed

775-704     D        775      Description: 135 Degree Short Stroke Draw failed

775-705     D        775      Description: White screen error, or 180
                              Degree Short Stroke Draw failed

775-706     D        775      Description: 225 Degree Short Stroke Draw failed
775-707     D        775      Description: 270 Degree Short Stroke Draw failed
775-708     D        775      Description: 315 Degree Short Stroke Draw failed
775-709     D        775      Description: Short Stroke Vector Function test failed
775-727     D        775      Description: 11 x 9 Cross hatch grid failed.
775-750     D     Info code   Description: The SCROLLING_21_H_TEST  failed.
775-753     D     Info code   Description: The EMC_SCROLLING_17_H_TEST failed
775-7FE     D        775      Description: Short Stroke Vector Function test failed
775-7FF     D     software    Description: Bad vector detected
775-801     D        775      Description: Color for PatBlt thru screen failed
775-802     D        775      Description: Clipping for PatBlt thru screen failed
775-803     D        775      Description: Color for PatBlt Across screen failed
775-804     D        775      Description: Clipping for PatBlt Across screen failed
775-805     D        775      Description: Pattern Fill Across the Plane test failed
775-8FF     D        775      Description: Pattern Fill Across the Plane test failed
775-901     D        775      Description: Color miscompare of white boxes detected
775-902     D        775      Description: Clipping error of white boxes detected
775-903     D        775      Description: Color miscompare of color bars detected
775-904     D        775      Description: Clipping error of white boxes detected
775-905     D        775      Description: Color miscompare of white boxes detected
775-906     D        775      Description: Clipping error of white boxes detected
775-907     D        775      Description: Color miscompare of white boxes detected
775-908     D        775      Description: Clipping miscompare of white  boxes detected                      
775-909     D        775      Description: The Area fill test (color bars) failed
775-9FF     D        775      Description: The Area fill test (color bars) failed
775-937     D        775      Description: Red screen error
775-959     D        775      Description: White screen error
775-961     D        775      Description: Black screen error
775-A01     D        775      Description: Color miscompare of horizontal top line      
775-A02     D        775      Description: Clipping error of horizontal top line                      
775-A03     D        775      Description: Color miscompare of vertical right line
775-A04     D        775      Description: Clipping error of vertical right line
775-A05     D        775      Description: Color miscompare of horizontal bottom line
775-A06     D        775      Description: Clipping error of horizontal bottom line
775-A07     D        775      Description: Color miscompare of vertical left line
775-A08     D        775      Description: Clipping error of vertical left line
775-A09     D        775      Description: Color miscompare of horizontal center line
775-A0A     D        775      Description: Clipping error of horizontal center line
775-A0B     D        775      Description: Color miscompare of vertical center line
775-A0C     D        775      Description: Clipping error of vertical center line
775-A0D     D        775      Description: Reserved
775-A0F     D        775      Description: Reserved
775-A10     D        775      Description: Color miscompare of textured top line
775-A11     D        775      Description: Clipping error of textured top line
775-A12     D        775      Description: Line Drawing Function test failed
775-AFF     D        775      Description: Line Drawing Function test failed
775-B01     D        775      Description: Rectangle Area Color miscompare detected
775-B02     D        775      Description: Rectangle Area Clip error detected
  
775-B03     D        775      Description: Clipped Area Horizontal color
                              miscompare (background line color wrong)

775-B04     D        775      Description: Clipped Area Horizontal clip
                              miscompare (clip of background line wrong)

775-B05     D        775      Description: Clipped Area Vertical color
                              miscompare (background line color wrong)

775-B06     D        775      Description: Clipped Area Vertical clip
                              error (clip of background line wrong)

775-B07     D        775      Description: The clipping function test failed.
775-BFF     D        775      Description: The clipping function test failed.
775-C01     D        775      Description: The BIOS read failed.
775-C02     D        775      Description: The BIOS function test failed.
775-CFF     D        775      Description: The BIOS function test failed.
775-D01     D        775      Description: The HW cursor function test failed.
775-DFF     D        775      Description: The HW cursor function test failed.
776-104     D        D46      Description: Connect Test Failure
776-105     D        D46      Description: Wrap Test Failure
776-106     D        D46      Description: Wrap Test Failure
776-201     D        776      Description: Configuration Register Test Failure  
776-202     D        776      Description: I/O Test Failure
776-203     D        776      Description: Adapter On-Card Test Failure
776-204     D        776      Description: Connect Test Failure
776-205     D        776      Description: Wrap Test Failure
776-206     D        776      Description: Wrap Test Failure
776-304     D        D46      Description: Connect Wrap Test Failure
776-305     D        D46      Description: Wrap Test Failure
776-306     D        D46      Description: Wrap Test Failure
776-404     D        240      Description: Connect Test Failure
776-405     D        240      Description: Wrap Test Failure
776-406     D        240      Description: Wrap Test Failure.

776-414     F        240      Description: Connect Test Failure. This
                              failure occurs if not connected to a
                     D46      functional Token-Ring network.
                              Action: Run advanced diagnostics for this
                     776      resource to obtain correct problem
                              isolation.
                      
776-415     F        240      Description: Wrap Test Failure. This
                              failure occurs if not connected to a
                     D46      functional Token-Ring network.
                              Action: Run advanced diagnostics for this
                     776      resource to obtain correct problem
                              isolation.

776-416     F        240      Description: Wrap Test Failure. This
                              failure occurs if not connected to a
                     D46      functional Token-Ring network.
                              Action: Run advanced diagnostics for this
                     776      resource to obtain correct problem
                              isolation.

776-702     G        776      Description: ELA indicates a Token-Ring
                              adapter check.

776-703     G        776      Description: ELA indicates that the
                              Token-Ring device driver has experienced a
                     221      DMA failure
                      
776-704     G        776      Description: ELA indicates that the
                              Token-Ring device driver has experienced a
                     221      PCI bus failure

776-705     G        776      Description: ELA indicates that the
                              Token-Ring device driver has seen a
                      221     Programmed I/O (PIO) failure.
                      
777-201     D        777      Description: Configuration Register Test Failure 221
777-202     D        777      Description: I/O Test Failure   221
777-203     D        777      Description: Adapter initialization test failure 221
777-204     D        777      Description: Internal wrap test failure  221
777-205     D        777      Description: Internal wrap test failure  221
777-206     D        777      Description: External wrap (10Mbps) testfailure 221
777-207     D        777      Description: Internal wrap test failure   221
777-208     D        777      Description: External wrap (100Mbps) test failure

777-701     G        777      Description: Error log analysis indicates
                              that the adapter is not responding to
                      221     initialization commands.

777-702     G        777      Description: Error Log Analysis indicates
                              that the device driver has detected a PIO
                     221      error which it was unable to correct.
                     
777-703     G        777      Description: Error log analysis indicates
                              that the adapter has been shut down due to
                     221      an unrecoverable error.
                     
777-704     G        777      Description: Error Log Analysis indicates
                              a problem with the EEPROM on the adapter  221
                               
780-101     D        780      Description: Adapter logic test failure  227
780-102     D        780      Description: Adapter logic test failure.
780-109     D        780      Description: Adapter channel Input/Output test failure.

780-113     D        780      Description: Adapter Serial Communication
                              Controller (SCC) test failure.

780-114     D        780      Description: Adapter logic test failure. 227

780-120     D        780      Description: Adapter could not be detected
                              or configured.     227 software
                              
780-140     D        271      Description: An error was found with the
                              X.21 interface adapter cable.   780
                               
780-150     D        272      Description: An error was found with the
                              X.24 interface adapter cable. 780
                               
780-160     D        273      Description: An error was found with the
                              X.35 interface adapter cable.   780
                               
780-170     D        780      Description: The adapter hardware failed.
780-180     D        780      Description: The adapter hardware failed.
780-190     D        780      Description: The adapter hardware failed.
780-210     D        780      Description: An error was found on the adapter.185
780-211     D        780      Description: The adapter card POST test failed. 227
780-230     D        780      Description: The adapter card hardware failed.
780-232     D        849      Description: The adapter card hardware failed.227
780-240     D        780      Description: The adapter card hardware failed.
780-250     D        185      Description: An error was found on the adapter.780
780-260     D        780      Description: The adapter card hardware failed.
780-270     D        780      Description: The adapter card hardware failed.
780-280     D        780      Description: The adapter card hardware failed.
780-290     D        780      Description: The adapter card hardware failed.

780-300     G        780      Description: An adapter error was found
                              during error log analysis.

780-310     G        780      Description: An adapter error was found
                              during error log analysis.    185

780-320     G        780      Description: An adapter error was found
                              during error log analysis.     227
                               
780-330     G        780      Description: Error log analysis indicates
                              a hardware problem.     227
                               
780-400     D        780      Description: A software error was caused
                              by a hardware failure.    227

780-700     D        780      Description: The adapter failed to configure.227 software
780-720     D        780      Description: Cable wrap test failed.
780-721     D        780      Description: Port wrap test failed.
780-722     D        780      Description: Cable wrap test failed.

781-101     D        781      Description: ROS POST adapter software
                              initialization error.    227

781-102     D        781      Description: Extended DRAM SIP test failed.
781-103     D        781      Description: ROS checksum test failed.
781-104     D        781      Adapter download diagnostics failed 227
781-105     D        781      Description: Memory size test failed. 227
781-106     D        781      Description: Interface ID test failed. 227
781-107     D        781      Description: EIB ID test failed.227
781-108     D        781      Description: ROS version test failed.  227
781-109     D        781      Description: DUSCC register test failed.
781-111     D        781      Description: DMA register test failed.
781-112     D        781      Description: X.21 PAL test failed.
781-113     D        781      Description: External wrap test failed.
781-114     D        781      Description: Twin tail logic test failed. 227
781-116     D        254      Description: The RS-232 cable wrap test failed.
781-117     D        253      Description: The RS-422A cable wrap test failed.
781-118     D        257      Description: The V.35 cable wrap test failed.
781-119     D        260      Description: The X.21 cable wrap test failed.
  
781-120     D        781      Description: The adapter was not detected
                              or could not be configured. test failed.
                     227      software
                     
781-121     D        781      Description: The 4-port jumper cable
                              assembly wrap test failed. 227 software

781-200     G        781      Description: The error log analysis
                              indicates the adapter failed.

781-221     G        781      Description: The error log analysis
                              indicates the adapter hardware failed.  227
                               
781-231     D        855      Description: No interface card detected. 227
781-501     D        B77      Description: The power-on self-test (POST)failed.B69 227
781-502     D        B77      Description: The memory module failed.
781-503     D        781      Description: Adapter hardware failure. 227
781-504     D        B69      Description: Adapter hardware failure.
781-505     D        B71      Description: Adapter hardware failure.  B69
781-506     D        B72      Description: Adapter hardware failure. B69
781-507     D        B73      Description: Adapter hardware failure. B69
781-508     D        B74      Description: Adapter hardware failure. B69
781-516     D        B77      Description: Adapter Test Failure    B69
781-517     D        B69      Description: Adapter Test Failure     B77
781-720     D        258      4-port multiprotocol cable   781
783-110     D        783      Description: The Reserve command failed.
783-120     D        783      Description: The Inquiry command failed.
783-130     D        783      Description: The Load command failed. media
783-135     D        783      Description: The Unload command failed. media
783-140     D        783      Description: The Mode Select command failed.
783-150     D        783      Description: The Test Unit Ready command failed.media
783-160     D        783      Description: The Send Diagnostic command failed.media
783-169     D        783      Description: The send diagnostic command failed.media
783-170     D        783      Description: The Read, Write and Compare test failed.media
783-180     D        783      Description: The Load command failed. media
783-185     D        783      Description: The Unload command failed. media
783-190     D        783      Description: The Mode Select command failed.
783-200     D        783      Description: The Test Unit Ready command failed.media
783-210     D        783      Description: The device configuration failed.     B88
783-220     D        783      Description: The Release command failed.
783-230     D        783      Description: The Request Sense command failed.
783-240     D        783      Description: The Openx command failed.
783-300     D        783      Description: The device configuration failed.software
783-310     D        B88      Description: SCSI adapter configuration failed.783 software
783-320     G        783      Description: Error log analysis indicates a failure. media

783-411     D        783      Description: A reservation conflict
     to                       occurred.
783-423              B88      software

783-511     D        783      Description: The drive returned bad or
     to                       non-extended sense data.
783-523              B88

783-611     D        783      Description: An adapter or bus I/O error
     to                       occurred.
783-623              B88      software

783-711     D        783      Description: A device timeout error
     to                       occurred.
783-723              B88      software

784-102     D        784      Description: An unrecoverable media error.
784-104     D        784      Description: The motor failed to restart.
784-105     D        784      Description: The drive did not become ready.
784-106     D        784      Description: The electronics card test failed.
784-108     D        784      Description: The bus test failed.
784-110     D        784      Description: The media format is corrupted.
784-112     D        784      Description: The diagnostic test failed.
784-114     D        784      Description: An unrecoverable hardware error.

784-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

784-117     D        784      Description: A write protect error occurred.
784-118     D        784      Description: A SCSI command time-out.   B88
784-120     D        784      Description: A SCSI busy or command error.
784-122     D        784      Description: A SCSI reservation conflict error.
784-124     D        784      Description: A SCSI check condition error.

784-126     D        784      Description: A software error was caused
                              by a hardware failure.    B88
                               
784-128     G        784      Description: The error log analysis
                              indicates a hardware failure.

784-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.  784 B88 software

784-130     G        784      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

784-132     D        784      Description: A disk drive hardware error occurred.
784-134     D        B88      Description: The adapter failed to configure.software
784-135     D        784      Description: The device failed to configure.software
784-136     D        784      Description: The certify operation failed.

784-137     D        784      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
785-111     D        785      Could not do the test because the device
                              driver detected a hardware error.

785-114     D        785      The register verification test failed.

785-121     D        785      Could not do the test because the device
                              driver detected a hardware error.

785-122     D        785      The data wrap communication test failed.
785-123     D        785      The modem control line test failed.
785-124     D        785      The memory test failed.

785-151     D        785      Could not do the test because the device
                              driver detected a hardware error.

785-152     D        785      The data wrap communication test failed.
785-153     D        785      The modem control line test failed.

785-171     D        259      Could not do the test because the device
                              driver detected a hardware error.

785-172     D        259      The data wrap communication test failed.
785-173     D        259      The modem control line test failed.

785-181     D        261      Could not do the test because the device
                              driver detected a hardware error.

785-182     D        261      The data wrap communication test failed.
785-183     D        261      The modem control line test failed.

785-251     D        785      Could not perform because the device
                              driver detected a hardware error.

785-252     D        785      The data wrap communication test failed.
785-253     D        785      The modem control line test failed.

785-271     D        785      Could not perform because the device
                              driver detected a hardware error.

785-272     D        785      The data wrap communication test failed.
785-273     D        785      The modem control line test failed.

785-281     D        785      Could not perform because the device
                              driver detected a hardware error.

785-282     D        785      The data wrap communication test failed.
785-283     D        785      The modem control line test failed.

785-481     D        D57      Could not do the test because the device
                              driver detected a hardware error.

785-482     D        D57      The data wrap communication test failed.
785-483     D        D57      The modem control line test failed.

785-901     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to              785      hardware.
785-920                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 785; otherwise, suspect a software
                              problem.

785-921     D        785      Description: The adapter failed to configure software

785-922     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to               785     hardware.
785-924                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 785; otherwise, suspect a software
                              problem.

785-925     D        785      Description: The adapter failed to configure software

785-926     D     software    Description: An unexpected error occurred
                              that can be attributed to software or
     to               785     hardware.
785-943                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 785; otherwise, suspect a software
                              problem.

786-200     D        786      Description: Initiation failed D96 
                              Note: You must determine which of the first
                              two FFCs is installed in the system unit.
                      
786-210     D        786      Description: The adapter test failed
786-211     D        D96      Description: The adapter test failed
786-220     D        786      Description: The display test failed Cable Monitor
786-221     D        D96      Description: The display test failed Cable Monitor
786-710     D        786      Description: The ELA indicates HW failure
786-711     D        D96      The ELA indicates HW failure
787-100     D        787      GXT500P Graphics Adapter
787-101     D        787      Description: GXT500P Graphics Adapter
787-1AA     D        787      Description: GXT500P Graphics Adapter RGB Cable Display
787-1xx     D        787      Description: GXT500P Graphics Adapter
787-200     D        D95      Description: GXT550P Graphics Adapter
787-201     D        D95      Description: GXT550P Graphics Adapter
787-2AA     D        D95      Description: GXT550P Graphics AdapterRGB Cable Display
787-2xx     D        D95      Description: GXT550P Graphics Adapter
788-001     D        788      Description: Adapter Error
788-002     D     software    Description: System Error
788-003     D     software    Description: System Error
788-004     D        788      Description: System Error  software
789-101     D        789      Description: Failed to release the device.
789-102     D        789      Description: Failed to reserve the device.
789-103     D        789      Description: The device motor failed to start.
789-104     D        789      Description: Failed to make the device ready.
789-105     D        789      Description: Failed to get the inquiry data.
789-106     D        789      Description: The Prevent Media Removal command failed.
789-107     D        789      Description: The Allow Media Removal command failed.

789-200     D        789      Description: The optical disk failed to load. 
                              Optical Disk Action: Change the media. 
                              Run diagnostics
                              on the changed media in System Verification
                              mode. If the error reoccurs use Chapter 12.
                              "MAP 0210: General Problem Resolution";
                              otherwise, replace the media.

789-201     D        789      Description: Failed to unload the optical
                              disk.   Optical Disk Action: Change the media. 
                              Run diagnostics
                              on the changed media in System Verification
                              mode. If the errors reoccur use Chapter 12.
                              "MAP 0210: General Problem Resolution";
                              otherwise, replace the media.
  
789-202     D        789      Description: The diagnostic test failed.
                              Action: Change the media. Run diagnostics
                              Optical Disk on the changed media in System Verification
                              mode. If errors do not reoccur, replace the
                              media; otherwise, run the drive cleaning
                              procedures if applicable and rerun the
                              diagnostics. If errors reoccur, or the
                              drive does not support the cleaning
                              procedures use Chapter 12. "MAP 0210:
                              General Problem Resolution".

789-204     D        789      Description: The device failed to configure.

789-205     D        789      Description: The Test Unit Ready command failed.
                              Optical Disk Action: Change the media. Run diagnostics
                              on the changed media in System Verification
                              mode. If the error reoccurs, use Chapter
                              12. "MAP 0210: General Problem Resolution";
                              otherwise, replace the media.

789-206     D        789      Description: The random write, read and
                              compare test failed.
                              Optical Disk Action: Change the media. Run diagnostics
                              on the changed media in System Verification
                              mode. If the errors do not reoccur, replace
                              the media; otherwise, run the drive
                              cleaning procedures if applicable, and
                              rerun diagnostics. If the errors reoccur,
                              or the drive does not support cleaning
                              procedures, use Chapter 12. "MAP 0210:
                              General Problem Resolution".

789-207     D        789      Description: A hardware error occurred.
                              Action: Change the media. Run diagnostics
                              Optical Disk on the changed media in System Verification
                              mode. If the errors do not reoccur, replace
                              the media; otherwise, run the drive
                              cleaning procedures if applicable, and
                              rerun diagnostics. If the errors reoccur,
                              or the drive does not support cleaning
                              procedures, use Chapter 12. "MAP 0210:
                              General Problem Resolution".

789-208     D        789     Description: The Mode Sense command failed.
                             Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".

789-209     D        789     Description: The Mode Select command failed.
                             Optical Disk Action: Change the media. Run diagnostics
                             on the changed media in System Verification
                             mode. If the errors do not reoccur, replace
                             the media; otherwise, run the drive
                             cleaning procedures if applicable, and
                             rerun diagnostics. If the errors reoccur,
                             or the drive does not support cleaning
                             procedures, use Chapter 12. "MAP 0210:
                             General Problem Resolution".

789-300     D        789      Description: A SCSI reservation conflict has occurred.software
789-400     D        789      Description: A SCSI command time out has occurred.Cables software
789-401     D   Optical Disk  Description: An unknown error has occurred.                      
789-402     D   Optical Disk  Description: Unit attention condition has occurred.software

789-600     G   Optical Disk  Description: ELA indicates that the spare
                              sectors on the disk are exhausted.
                              Action: Backup the media and replace it.
                              Note: Use the time when the error occurred
                              and the "Spare Sector Availability" service
                              aid to identify the disk that has the error.

789-700     G        789      Description: The ELA indicates an equipment error.
                              Optical Disk Action: Run diagnostics in System
                              Verification mode to isolate the problem.
                              If errors are reported, use Chapter 12.
                              "MAP 0210: General Problem Resolution";
                              otherwise, the error is due to faulty
                              media. Backup the media and then replace it.
                              Note: Use the time when the error occurred
                              to identify the faulty media.

789-701     G   Optical Disk  Description: ELA indicates an
                              irrecoverable data error.
                      789     Action: Run diagnostics in System
                              Verification mode to isolate the problem.
                              If errors are reported, use Chapter 12.
                              "MAP 0210: General Problem Resolution";
                              otherwise, the error is due to faulty
                              media. Backup the media and then replace it.
                              Note: Use the time when the error occurred
                              to identify the faulty media.

789-702     G        789      Description: ELA indicates that the
                              adapter detected an error.
                     B88      Action: Use the 7209 Installation and
                              Service Guide. If the unit checks out to be
                    Cables    good, use Chapter 12. "MAP 0210: General
                              Problem Resolution".

790-101     D        790      Description: Configuration Register Test failure
790-102     D        790      Description: I/O test failure
790-103     D        790      Description: Adapter initialization test failure
790-104     D        790      Description: Internal wrap test failure
790-105     D        790      Description: Internal wrap test failure
790-106     D        790      Description: External wrap (10Mbps) test failure
790-107     D        790      Description: Internal wrap test failure
790-108     D        790      Description: External wrap (100Mbps) test failure
790-109     D        790      Description: External wrap (10Mbps) test failure
790-121     D        790      Description: Configuration register test failure
790-122     D        790      Description: I/O register test failure
790-124     D        790      Description: Internal loopback test failure
790-125     D        790      Description: Internal loopback test failure
790-126     D        790      Description: External loopback test failure
790-150     D        B08      Description: 10Base-T transceiver test failure
790-151     D        B09      Description: 10Base-2 transceiver test failure
790-223     D        790      Description: Device configuration failure software
790-224     D        B08      Description: 10 Base-T transceiver test failure
790-225     D        B09      Description: 10 Base-2 transceiver test failure 790
790-250     D        B08      Description: 10 Base-T transceiver test failure
790-251     D        B09      Description: 10 Base-2 transceiver test failure

790-701     G        790      Description: Error Log Analysis indicates
                              that the adapter is not responding to
                              initialization commands.

790-702     G        790      Description: Error Log Analysis indicates
                              that the device driver has detected a PIO
                              error which it was unable to correct.

790-703     G        790      Description: Error Log Analysis indicates
                              that the adapter has been shutdown due to
                              an unrecoverable error.

790-704     G        790      Description: Error Log Analysis indicates
                              a problem with EEPROM on the adapter.

790-720     G        790      Description: Error log analysis indicates
                              a hardware problem    software
                               
791-098       J       791     Description: The disk drive indicates an error. B88
791-099       J       791     Description: The disk drive not found.                      
791-102       D       791     Description: An unrecoverable media error occurred.
791-104       D       791     Description: The motor failed to restart.
791-105       D       791     Description: The drive did not become ready.
791-106       D       791     Description: The electronics card test failed.
791-108       D       791     Description: The bus test failed.
791-110       D       791     Description: The media format is corrupted.
791-112       D       791     Description: The diagnostic test failed.
791-114       D       791     Description: An unrecoverable hardware error.

791-116       D               Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

791-117       D       791     Description: A write protect error occurred.
791-118       D       791     Description: A SCSI command time-out occurred.
791-120       D       791     Description: A SCSI busy or command error.
791-122       D       791     Description: A SCSI reservation conflict error.
791-124       D       791     Description: A SCSI check condition error occurred.

791-126       D       791     Description: A software error was caused
                              by a hardware failure.

791-128       G       791     Description: The error log analysis
                              indicates a hardware failure.
                               
791-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.

791-130     G        791      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

791-132     D        791      Description: A disk drive hardware error occurred.
791-134     D        B88      Description: The adapter failed to configure. software
791-135     D        791      Description: The device failed to configure. software
791-136     D        791      Description: The certify operation failed.

791-137     D        791      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
792-098     J        792     Description: The disk drive indicates an error.                    
792-099     J        792     Description: The disk drive not found.                   
792-102     D        792     Description: An unrecoverable media error occurred.
792-104     D        792     Description: The motor failed to restart.
792-105     D        792     Description: The drive did not become ready.
792-106     D        792     Description: The electronics card test failed.
792-108     D        792     Description: The bus test failed.
792-110     D        792     Description: The media format is corrupted.
792-112     D        792     Description: The diagnostic test failed.
792-114     D        792     Description: An unrecoverable hardware error.

792-116     D                Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
  
792-117      D       792     Description: A write protect error occurred.
792-118      D       792     Description: A SCSI command time-out occurred.
792-120      D       792     Description: A SCSI busy or command error.
792-122      D       792     Description: A SCSI reservation conflict error.
792-124      D       792     Description: A SCSI check condition error occurred.

792-126      D       792     Description: A software error was caused
                             by a hardware failure.

792-128      G       792     Description: The error log analysis
                             indicates a hardware failure.
                              
792-129      G        D50    Description: Error log analysis indicates
                             a SCSI bus problem.

792-130      G        792    Description: Error log analysis indicates
                             a problem reported by the disk drive's self
                             monitoring function.

792-132      D       792     Description: A disk drive hardware error occurred.
792-134      D       B88     Description: The adapter failed to configure.software
792-135      D       792     Description: The device failed to configure. software
792-136      D       792     Description: The certify operation failed.

792-137     D        792      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
793-098     J        793      Description: The disk drive indicates an error.
793-099     J        793      Description: The disk drive not found.
793-102     D        793      Description: An unrecoverable media error occurred.
793-104     D        793      Description: The motor failed to restart.
793-105     D        793      Description: The drive did not become ready.
793-106     D        793      Description: The electronics card test failed.
793-108     D        793      Description: The bus test failed.
793-110     D        793      Description: The media format is corrupted.
793-112     D        793      Description: The diagnostic test failed.
793-114     D        793      Description: An unrecoverable hardware error.

793-116     D                 Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.

793-117     D        793      Description: A write protect error occurred.
793-118     D        793      Description: A SCSI command time-out occurred.
793-120     D        793      Description: A SCSI busy or command error.
793-122     D        793      Description: A SCSI reservation conflict error.
793-124     D        793      Description: A SCSI check condition error occurred.
793-126     D        793      Description: A software error was caused by hardware failure.
                 
793-128     G        793      Description: The error log analysis
                              indicates a hardware failure.

793-129     G        D50      Description: Error log analysis indicates
                              a SCSI bus problem.

793-130     G        793      Description: Error log analysis indicates
                              a problem reported by the disk drive's self
                              monitoring function.

793-132      D       793      Description: A disk drive hardware error occurred.
793-134      D       B88      Description: The adapter failed to configure.software
793-135      D       793      Description: The device failed to configure.software
793-136      D       793      Description: The certify operation failed.

793-137      D       793      Description: Unit attention condition has
                              occurred on the Send Diagnostic command.
                      
795-201     D        795      Description: Config register test failure
795-202     D        795      Description: PROM check test failure
795-203     D        795      Description: Timer and IRQ test failure
795-204     D        795      Description: Adapter RAM check failure
795-205     D        795      Description: ASIC test failure
795-206     D        795      Description: High memory (ISA) test failure  
795-207     D        795      Description: RAM check via DMA test failure 
795-208     D        795      Description: FORMAC register test failure
795-209     D        795      Description: PLC1 test failure
795-210     D        795      Description: PLC2 test failure
795-211     D        795      Description: FORMAC Ring_Op test failure
795-212     D        795      Description: Send long frame test failure
795-213     D        795      Description: Restricted Token Monitor test failure
795-214     D        795      Description: Receive queue handling test failure
795-215     D        795      Description: FORMAC loopback test failure

795-216     D        795      Description: FORMAC loopback with master
                              access test failure

795-217     D        795      Description: DMA measurement test failure
795-218     D        795      Description: Special test failure
795-219     D        795      Description: Bypass test failure
795-301     D        795      Description: PLC1 FDDI external wrap failure
795-302     D        795      Description: PLC2 FDDI external wrap failure
795-303     D        795      Description: Send long frame FDDI external wrap failure
795-304     D        795      Description: FORMAC loopback external wrap failure

795-700     D        795      Description: Error log analysis indicates
                              hardware failure

799-101     D        2C3      Description: External wrap test failed on port 0
799-102     D        2C3      Description: External wrap test failed on port 1
799-201     D        799      Description: Internal adapter test failed
799-202     D        799      Description: External wrap test failed on port 0
799-203     D        799      Description: External wrap test failed on port 1
799-204     D        2C3      Description: External wrap test failed on port 0
799-205     D        2C3      Description: External wrap test failed on port 1
799-206     D        2C3      Description: External wrap test failed on port 0
799-207     D        2C3      Description: External wrap test failed on port 1
799-301     D        799      Description: Internal adapter test failed
799-302     D        799      Description: External wrap test failed on port 0
799-303     D        799      Description: External wrap test failed on port 1
799-304     D        2C3      Description: External wrap test failed on port 0
799-305     D        2C3      Description: External wrap test failed on port 1

799-700     D        799      Description: Error log analysis indicates
                              a hardware problem software

7C1-101     D        7C1      Description: Audio Subsystem failed software
7C1-102     D        7C1      Description: CS4232 Failed
7C1-103     D        7C1      Description: Clock control failed
7C1-107     D        7C1      Description: SoundBlaster interface failed
7C1-108     D        7C1      Description: Loop back failed
7C1-109     D        7C1      Description: CODEC ID invalid
7C1-117     D        D97      Description: Internal speaker failed

801-101     C                 Description: The diagnostics did not
                              detect an installed resource.
    to                        Action: Ensure supplemental diskettes have
                              been read, if applicable, then use Chapter
801-102                       18. "MAP 0290: Missing Resource Problem
                              Resolution".

802-787     C        787      Description: The diagnostics did not
                              detect an installed resource.

802-78C     C                 Description: A system bus problem exists.
                              Action: Use Chapter 11. "MAP 0080 System
                              Bus Problem Isolation".

802-xxx     C        xxx      Description: The diagnostics did not
                              detect an installed resource.
                              Note: To obtain the FFC substitute the last
                              three digits of the SRN for xxx. (The
                              substituted xxx is the FFC.)

803-xxx     D    Use the xxx  Description: An error occurred while
                              running the diagnostics.(See note number    
                              Action: Run nondisk-based diagnostics where
                              possible. If this SRN was generated from in Action                     
                              the nondisk-based diagnostic package, or it
                              is not possible to use the nondisk-based column.)                     
                              package, go to Chapter 15. "MAP 0250:
                              Unexpected System Halts During
                              Diagnostics". If the problem occurs only
                              from disk-or server-based diagnostics,
                              suspect a software problem.
                              Notes:
                              1. If your 803-xxx SRN is listed in
                                 this section, use the procedure
                                 for that SRN instead of this one.
                              2. If the xxx FFC is not listed in
                                 the FFC list, Use MAP 1540 to
                                 determine the failing FRU.

804-111     D        804      Description: Unable to reserve device.
804-112     D        804      Description: Unable to do configuration.
804-113     D        804      Description: Unable to open the device driver.  
804-121     D        804      Description: The CD-ROM drive indicates an error.
804-122     D        804      Description: The CD-ROM drive indicates an error.
804-123     D        804      Description: The CD-ROM drive indicates an error.
804-125     D        804      Description: The CD-ROM drive indicates an error.
804-126     D        804      Description: The CD-ROM drive indicates an error.
804-127     D        804      Description: The CD-ROM drive indicates an error.
804-128     D        804      Description: The CD-ROM drive indicates an error.
804-129     D        804      Description: The CD-ROM drive indicates an error.
804-150     D       Media     Description: A media error was detected.
804-151     D        804      Description: A command timeout was detected.
804-152     D        804      Description: A command reservation conflict was detected.
804-162     D        804      Description: The CD-ROM drive indicates an error.
804-171     D        804      Description: Unable to reserve device.
804-172     D        804      Description: Unable to do configuration.
804-173     D        804      Description: Unable to open device driver.
804-175     D        804      Description: The CD-ROM drive indicates an error.
804-198     D        804      Description: Undefined error detected.
804-199     D        804      Description: Undefined error detected.
804-211     D        804      Description: The LED test failed.
804-281     D        804      Description: No tone during audio test.
804-301     G        804      Description: Errors found during ELA.
804-302     G        804      Description: Errors found during ELA.

804-xxx     H      Use the    Description: An unexpected halt occurred
                              while running the diagnostics.
                      xxx     Note: If your 804-xxx SRN is listed in this number
                              section, use the procedure for that SRN
                              instead of this one.
                              Action: Use Chapter 15. "MAP 0250:
                              Unexpected System Halts During
                              Diagnostics".

805-110     G        D67      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-111     G        D83      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-120     G        D68      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-121     G        D84      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-130     G        D69      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-131     G        D85      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-140     G        D70      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-141     G        D86      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-150     G        E11      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-151     G        E14      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-210     G        D71      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-211     G        D87      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-220     G        D72      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory  error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-221     G        D88      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-230     G        D73      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory  error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-231     G        D89      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-240     G        D74      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-241     G        D90      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-250     G        E12      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-251     G        E15      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory  error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-310     G        D75      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-311     G        D91      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-320     G        D76      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-321     G        D92      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-331     G        D93      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-340     G        D78      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-341     G        D94      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-350     G        E13      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-351     G        E16      Description: Error log analysis indicates
                              a machine check due to uncorrectable memory error.
                              Action: Use Chapter 14. "MAP 0240: Memory
                              Problem Resolution".

805-600     G                 Description: Error log analysis indicates
                              a machine check due to uncorrectable memory
                              error or unsupported memory.
                              Action: Examine the memory modules and
                              determine if they are supported types. If
                              the modules are supported, then replace the
                              appropriate memory module(s). Use Chapter
                              14. "MAP 0240: Memory Problem Resolution".
                               
805-601     G        210      Description: Error log analysis indicates
                              a machine check due to CPU internal cache error.

805-602     G        214      Description: Error log analysis indicates
                              a machine check due to CPU address/data bus
                     D01      parity error.
                     
805-603     G        210      Description: Error log analysis indicates
                              a machine check due to CPU bus transfer error.
                              
805-604     G        210      Description: Error log analysis indicates
                              a machine check due to CPU address/data bus parity error.

805-605     G        210      Description: Error log analysis indicates
                              a machine check due to CPU bus transfererror.

805-606     G        214      Description: Error log analysis indicates
                              a machine check due to memory controller internal error.

805-607     G        210      Description: Error log analysis indicates
                              a machine check due to memory address error.
                               
805-608     G        214      Description: Error log analysis indicates
                              a machine check due to a Flash ROM error.

805-609     G        D01      Description: Error log analysis indicates
                              a machine check due to a L2 parity error.

805-610     G                 Description: Error log analysis indicates
                              a machine check due to ISA device error,
                              but the device could not be identified.
                              Action: Run diagnostics on the ISA devices.
                               
805-611     G                 Description: Error log analysis indicates
                              a machine check due to EISA/ISA bus time
                              out error, but the device could not be identified.
                              Action: Run diagnostics on the ISA devices.
                              If multiple devices fail, use FFC 295.

805-612     G        214      Description: Error log analysis indicates
                              a machine check due to an Illegal L2 copyback operation.

805-616     G     software    Description: Error log analysis indicates
                              a machine check due to software.

805-617     G                 Description: Error log analysis indicates
                              a machine check of unknown origin.
                              Action: If the problem is persistent, use
                              MAP 1540.

805-618     G                 Description: Error log analysis indicates
                              multiple instances of machine check of
                              unknown origin.
                              Action: If the problem is persistent, use
                              MAP 1540.

805-619     G        221      Description: Error log analysis indicates
                              a machine check due to an unidentified
                              source on the I/O subsystem. Action: Use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

805-621     G        292      Description: Error log analysis indicates
                              a machine check due to Integrated PCI
                              device does not respond.

805-622     G        293      Description: Error log analysis indicates
                              a machine check due to Integrated PCI
                              device does not respond.

805-623     G        294      Description: Error log analysis indicates
                              a machine check due to Integrated PCI
                              device does not respond.

805-624     G        295      Description: Error log analysis indicates
                              a machine check due to Integrated PCI
                              device does not respond.

805-625     G        868      Description: Error log analysis indicates
                              a machine check due to Integrated PCI
                              device does not respond.

805-631     G        292      Description: Error log analysis indicates
                              a machine check due to Internal error from
                              PCI device.

805-632     G        293      Description: Error log analysis indicates
                              a machine check due to Internal error from
                              PCI device.

805-633     G        294      Description: Error log analysis indicates
                              a machine check due to Internal error from
                              PCI device.

805-634     G        295      Description: Error log analysis indicates
                              a machine check due to Internal error from
                              PCI device.

805-635     G        868      Description: Error log analysis indicates
                              a machine check due to Internal error from
                              PCI device.

805-640     G        2E8      Description: Error log analysis indicates
                              a machine check due to a system bus error.

805-641     G        2E8      Description: Error log analysis indicates
                              a machine check due to a processor bus error.
                               
805-642     G        2E8      Description: Error log analysis indicates
                              a machine check due to a directory parity error.

805-643     G        2E8      Description: Error log analysis indicates
                              a machine check due to a cache paradox.

805-644     G        2E8      Description: Error log analysis indicates
                              a machine check due to an internal error.

805-645     G        2E8      Description: Error log analysis indicates
                              a machine check due to a detected L2 hit signal.

805-646     G        2E8      Description: Error log analysis indicates
                              a machine check due to an address/data bus parity error.
                               
805-649     G     software    Description: Error log analysis indicates
                              a machine check due to a disabled I/O address space.
                              Action: Run Standalone Diagnostics on all
                              devices. Use any SRN reported. If no other
                              SRN is reported, suspect a software problem.

805-801     G        166      Description: Slow fan or defective thermal sensor.
                     221      Action: 1) Check spacing around system
                              enclosure, 2) check for obstructions to
                              cooling air flow, 3) check that all fans
                              can rotate freely, and spin with power
                              applied. If reasons 1, 2 and 3 can be ruled
                              out, then replace the listed FRUs.

805-802     G        152      Description: Over/Under voltage condition.
                     210      Action: Check AC line voltage per the Power
                              MAP in your service guide. If the AC line
                              voltage is correct replace the listed FRUs.
                              
805-803     G        2E1      Description: System shutdown due to
                              non-critical over temperature condition.
                     210      Action: 1) check for obstructions to
                              cooling air flow, 2) check for accumulated
                              dust on the CPU and planar. If reasons 1
                              and 2 can be ruled out, then replace the listed FRUs.

805-804     G        166     Description: System shutdown due to
                             critical over temperature condition.
                     2E1     Action: Check to ensure fans are connected.
                             If fans are connected, then replace the listed FRUs.
                               
805-805     G        152      Description: System shutdown due to loss of AC power.
                               Action: Check the voltage range switch, if
                               present, on the power supply and ensure
                               that it is set to match the AC input
                               voltage. If the range switch is set
                               correctly or is not present refer to "MAP
                               1520: Power" in the Service Guide for your system.

805-807     G        166     Description: System shutdown due to an inoperative fan.
                             Action: Check to ensure fans are connected.
                             If fans are connected replace the listed FRU.

805-811     D        166     Description: Slow fan or defective thermal sensor.
                             Action:
                             1. Check spacing around system enclosure
                             2. Check for obstructions to cooling air flow
                             3. Check that all fans rotate freely, and
                               spin when power is applied.
                               If reasons 1, 2, and 3 can be ruled out,
                               then replace the listed FRUs.

805-812     D        152      Description: Over/Under voltage condition.
                     210      Action: Check the AC line voltage per the
                              Power MAP in your service guide. If the AC
                              line voltage is correct replace the listed FRUs.

805-813     D        2E1      Description: System shutdown due to
                              non-critical over temperature condition.
                     210      Action:
                              1. Check for obstructions to cooling air flow.
                              2. Check for accumulated dust on the CPU and planar.
                              If reasons 1 and 2 can be ruled out, then
                              replace the listed FRUs.

806-001     D        806      GXT800P Graphics Adapter
   thru
806-017

806-018     D        806      GXT800P Graphics Adapter Monitor/Display Cable
806-100     D        806      Description: GXT800P Graphics Adapter

806-505     D        806      Description: GXT800P Graphics Adapter
                              GXT800P Base Memory in slot 0, 1, 2, 3, or 4
                              
806-515     D        806      Description: GXT800P Graphics Adapter
                              GXT800P Base and Texture Memory in slot 0,
                              1, 2, 3, or 4
                              
806-619     G        221      Description: Error log analysis indicates
                              a machine check due to an unidentified
                              source on the I/O subsystem.

806-700     D        298      GXT800P Base Memory in slot 0
806-701     D        298      GXT800P Base Memory in slot 1
806-702     D        298      GXT800P Base Memory in slot 2
806-703     D        298      GXT800P Base Memory in slot 3
806-704     D        298      GXT800P Base Memory in slot 4
806-710     D        297      GXT800P Base and Texture Memory in slot 0
806-711     D        297      GXT800P Base and Texture Memory in slot 1
806-712     D        297      GXT800P Base and Texture Memory in slot 2
806-713     D        297      GXT800P Base and Texture Memory in slot 3
806-714     D        297      GXT800P Base and Texture Memory in slot 4
806-e00     D        298      GXT800P Base Memory in slot 0
806-e01     D        298      GXT800P Base Memory in slot 1
806-e02     D        298      GXT800P Base Memory in slot 2
806-e03     D        298      GXT800P Base Memory in slot 3
806-e04     D        298      GXT800P Base Memory in slot 4
806-e10     D        297      GXT800P Base and Texture Memory in slot 0
806-e11     D        297      GXT800P Base and Texture Memory in slot 1
806-e12     D        297      GXT800P Base and Texture Memory in slot 2
806-e13     D        297      GXT800P Base and Texture Memory in slot 3
806-e14     D        297      GXT800P Base and Texture Memory in slot 4
807-201     D        199      Description: Device configuration error                    
807-202     D        199      Description: Enclosure failed to open
807-203     D        199      Description: Enclosure failed to return inquiry data
807-204     D        152      Description: Redundant power supply or fan failure
807-205     D        152      Description: Redundant power supply or fan failure
814-112     D        814      Description: The NVRAM test failed.
814-113     D        221      Description: The VPD test failed.
814-114     D        814      Description: I/O Card NVRAM test failed.
815-100     D        815      Description: The floating-point processor test failed.
815-101     D        815      Description: Floating point processor failed.
815-102     D        815      Description: Floating point processor failed.
815-200     D        815      Description: Floating point processor failed.
816-140     D        165      Description: The four-digit display test failed.
817-123     D        817      Description: The I/O planar time-of-day clock test failed.
817-124     D        817      Description: Time of day RAM test failed.
817-210     D        817      Description: The time-of-day clock is at POR.
817-211     D        817      Description: Time of day POR test failed.
817-212     D        151      Description: The battery is low.
817-213     D        817      Description: The real-time clock is not running.
817-215     D        817      Description: Time of day clock not running test failed.
817-217     D        817      Description: Time of day clock not running.
821-111     D        821      Description: Unexpected results from the test.
821-220     D        B10      Description: Keyboard adapter fuse failed.
821-221     D        821      Description: The keyboard adapter test failed.
821-230     D        221      Description: Software error caused by hardware failure.

821-240     G        821      Description: The error log analysis
                              indicates hardware failure.

821-241     G        221      Description: The error log analysis
                              indicates hardware failure.

821-242     G        921      Description: The error log analysis
                              indicates hardware failure.

821-243     G        922      Description: The error log analysis
                              indicates hardware failure.

821-244     G        923      Description: The error log analysis
                              indicates hardware failure.

821-310     D        821      Description: Standard Keyboard Adapter
     to                       failed.
821-331

821-332     D        821      Description: Cannot open device.software

821-333     D        821      Description: Keyboard/tablet adapter failed.
     to
821-334

821-921     D        921      Description: The keyboard adapter control logic failed.
821-922     D        922      Description: The keyboard adapter control logic failed.
821-923     D        923      Description: The keyboard adapter control logic failed.

823-111     D        823      Description: Standard Mouse adapter failed.
    to               925
823-112

823-113     D        B10      Description: The mouse adapter fuse failed.
  
823-121     D        823      Description: Built-In mouse adapter problems.
    to
823-122

823-130     D        221      Description: Software error caused by
                              hardware failure.

823-131     D        823      Description: Unable to put mouse adapter
                              into nonblock mode.

823-132     D        823      Description: Built-In mouse adapter problem.
     to
823-133

823-134     D        823      Description: Cannot open device.  software

823-140     G        823      Description: The error log analysis
                              indicates hardware failure.

823-141     D        823      Description: Unable to place mouse adapter
                              in block mode.

823-142     D        823      Description: Unable to place mouse adapter
                              in block mode.

823-220     D        B10      Description: The mouse adapter fuse failed.
824-220     D        824      Description: The tablet adapter fuse failed.
824-331     D        824      Description: An unexpected error occurred.

824-332     D        824      Description: The enable/disable device test failed.
                     227      Note:Ensure that the wrap plug was not
                              attached when the test was run. If the wrap
                              plug was attached, remove it, and rerun the test.

824-333     D        824      Description: The internal wrap test failed.
824-334     D        B10      Description: The tablet adapter fuse failed.824
824-441     D        824      Description: An unexpected error occurred.
824-442     D        824      Description: The wrap test failed.
824-450     D        227      Description: Software error caused by hardware failure.

824-461     G        227      Description: The error log analysis
                              indicates a hardware failure.

824-511     D        824      Description: An unexpected error occurred.
824-512     D        824      Description: Tablet adapter reset test failed.
824-522     D        B10      Description: Adapter fuse failure.
824-523     D        824      Description: Device cannot be configured.
824-524     D        824      Description: Cannot open device. software

826-111     D        221      Description: Cannot run the test because
                              the device driver detected a hardware error.
  
826-112     D        221      Description: Unable to determine the type
                              of adapter from the VPD.

826-113     D        826      Description: The VPD verification test failed.

826-114     D        826      Description: The register verification test failed.

826-121     D        221      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-122     D        221      Description: The data-wrap communications test failed.

826-123     D        221      Description: The modem control line test failed.

826-131     D        221      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-132     D        221      Description: The data wrap communications test failed.

826-133     D        221      Description: The modem control line test failed.

826-161     D        252      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-162     D        252      Description: The data wrap communications test failed.

826-163     D        252      Description: The modem control line test failed.

826-171     D        259      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-172     D        259      Description: The data wrap communications
                              test failed.

826-173     D        259      Description: The modem control line test failed.

826-181     D        261      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-182     D        261      Description: The data wrap communications test failed.

826-183     D        261      Description: The modem control line test failed.

826-271     D        826      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-272     D        826      Description: The data wrap communications test failed.
826-273     D        826      Description: The modem control line test failed.

826-281     D        826      Description: Cannot run the test because
                              the device driver detected a hardware error.
                               
826-282     D        826      Description: The data wrap communications test failed.
826-283     D        826      Description: The modem control line test failed.

826-321     D        826      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-322     D        826      Description: The data wrap communications test failed.

826-323     D        826      Description: The modem control line test failed.

826-331     D        826      Description: Cannot run the test because
                              the device driver detected a hardware error.
 
826-332     D        826      Description: The data wrap communications test failed.
826-333     D        826      Description: The modem control line test failed.

826-371     D        826      Description: Cannot run the test because
                              the device driver detected a hardware error.

826-372     D        826      Description: The data wrap communications test failed.
826-373     D        826      Description: The modem control line test failed.

826-381     D        826      Description: Could not do the test because
                              the device driver detected a hardware  error.
 
826-382     D        826      Description: The data wrap communication test failed.
826-383     D        826      Description: The modem control line test failed.
 
826-481     D        D56      Description: Could not do the test because
                              the device driver detected a hardware error.

826-482     D        D56      Description: The data wrap communication test failed.
826-483     D        D56      Description: The modem control line test failed.

826-581     D        826      Description: Could not do the test because
                              the device driver detected a hardware error.

826-582     D        826      Description: The data wrap communication test failed.
826-583     D        826      Description: The modem control line test failed.

826-901     D     software    Description: An unexpected error occurred
   to                         that can be attributed to software or hardware.
826-920                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 826; otherwise, suspect a software problem.

826-921     D        826      Description: The adapter failed to configure software

826-922     D     software    Description: An unexpected error occurred
     to                       that can be attributed to software or hardware.
826-924                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 826; otherwise, suspect a software problem.

826-925     D        826      Description: The adapter failed to configure software

826-926     D     software    Description: An unexpected error occurred
   to                         that can be attributed to software or hardware.
826-943                       Action: Run diagnostics from a source other
                              than from the disk or a network. If the
                              same error occurs or if the original SRN
                              was not obtained from disk or a network
                              based diagnostics, use Chapter 12. "MAP
                              0210: General Problem Resolution" with a
                              FFC of 826; otherwise, suspect a software problem.

827-112     D        221      Description: The parallel port data
                              register write/read test failed.

827-121     D        827      Description: Cannot run the test because
                              the device driver detected a hardware error.

827-122     D        827      Description: The parallel port data
                              register write/read test failed.

827-123     D        827      Description: The parallel port control
                              register write/read test failed.

827-124     D        827      Description: The parallel port data
                              register read test failed.

827-125     D        827      Description: The parallel port control
                              register read test failed.

827-126     D        827      Description: The parallel port control
                              register read test failed.

827-131     D        827      Description: Cannot run the test because
                              the device driver detected a hardware  error.

827-132     D        827      Description: The control port register
                              direction bit (write) test with BIDI
                              enabled failed.

827-133     D        827      Description: The control port register
                              direction bit (read) test with BIDI enabled failed.
                              
827-141      D        827      Description: Cannot run the test because
                               the device driver detected a hardware error.
 
827-142      D        827      Description: The parallel port control
                               register write/read test with BIDI
                               enabled failed.

827-151      D        221      Description: Cannot run the test because
                               the device driver detected a hardware error.


827-152      D        827      Description: The parallel port status
                               register read test failed.

827-161      D        827      Description: Cannot run the test because
                               the device driver detected a hardware error.

827-162      D        221      Description: The parallel port interrupt
                               test failed.

827-163      D        221      Description: The parallel port interrupt
                               test failed.

827-201      D        827      Description: The extend control register
                               of the parallel port failed a read/write test.

827-202      D        827      Description: Input/output to the FIFO
                               (without interrupts) failed.

827-203      D        827      Description: Input/output to the FIFO
                               (with interrupts) failed.

827-204      D        827      Description: Direct memory access to the
                               FIFO failed.

828-501      D        828      Description: The diskette adapter test failed.
82C-102      D        82C      Description: Adapter test failed.
82C-104      D        82C      Description: Display test failed.

830-111      D        830      Description: Could not do the test
                               because the device driver detected a hardware error.
                               
830-114      D        830      Description: The register verification test failed.

830-121      D        830      Description: Could not do the test
                               because the device driver detected a
                       227     hardware problem.
                       
830-122      D        830      Description: The data wrap communication test failed.
830-123      D        830      Description: The modem control line test failed.
830-124      D        830      Description: The memory test failed.

830-151      D        B54      Description: Could not do the test
                               because the device driver detected a
                      830      hardware error.
                      
830-152      D        B54      Description: The data wrap communication test failed.
830-153      D        D54      Description: The modem control line test failed.

830-171      D        259      Description: Could not run the test
                               because the device driver detected a hardware error.

830-172      D        259      The data wrap communication test failed.
830-173      D        259      Description: The modem control line test failed.

830-181      D        261      Description: Could not do the test
                               because the device driver detected a
                               hardware error.

830-182      D        261      Description: The data wrap communication
                               test failed.

830-183      D        261      Description: Interposer Wrap test failed.

830-251      D        830      Description: Could not perform because
                               the device driver detected a hardware error.
                               
830-252      D        830      Description: The data wrap communication test failed.
830-253      D        830      Description: The modem control line test failed.

830-271      D        830      Description: Could not perform because
                               the device driver detected a hardware error.
                               
830-272      D        830      Description: The data wrap communication test failed.
830-273      D        830      Description: The modem control line test failed

830-281      D        830      Could not perform the test because the
                               device driver detected a hardware error.  

830-282      D        830      Description: The data wrap communication test failed.
830-283      D        830      Description: The modem control line test failed.

830-481      D        B54      Description: Could not do the test
                               because the device driver detected a
                               hardware error.

830-482      D        B54      Description: The data wrap communication test failed.

830-483      D        B54      Description: Async Cable Wrap Test failed.

830-901      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 830     software or hardware.
830-9 20                       Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 830; otherwise,
                               suspect a software problem.

830-921      D        830      Description: The adapter failed to
                               configure software
                               
830-922      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 830     software or hardware.
830-924                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 830; otherwise,
                               suspect a software problem.
  
830-925      D        830      Description: The adapter failed to
                               configure  software
                                 
830-926      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 830     software or hardware.
830-943                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 830; otherwise,
                               suspect a software problem.

831-111      D        221      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-112      D        221      Description: Unable to determine the
                               type of adapter from the VPD.

831-113      D        831      Description: The VPD verification test failed.
831-114      D        831      Description: The register verification test failed.
 
831-121      D        221      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-122      D        221      Description: The data wrap
                               communications test failed.

831-123      D        221      Description: The modem control line test failed.

831-131      D        221      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-132      D        221      Description: The data wrap
                               communications test failed.

831-133      D        221      Description: The modem control line test failed.

831-161      D        252      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-162      D        252      Description: The data wrap
                               communications test failed.

831-163      D        252      Description: The modem control line test failed.

831-164      D        221      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-165      D        221      Description: The data wrap
                               communications test failed.  
                                 
831-166      D        221      Description: The modem control line test failed.

831-171      D        259      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-172      D        259      Description: The data wrap
                               communications test failed.

831-173      D        259      Description: The modem control line test failed.

831-181      D        261      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-182      D        261      Description: The data wrap
                               communications test failed.

831-183      D        261      Description: The modem control line test failed.

831-271      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.
                               
831-272      D        831      Description: The data wrap communication test failed.
831-273      D        831      Description: The modem control line test failed.

831-281      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.
                               
831-282      D        831      Description: The data wrap communications test failed.
831-283      D        831      Description: The modem control line test failed.

831-321      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-322      D        831      Description: The data wrap
                               communications test failed.

831-323      D        831      Description: The modem control line test failed.

831-331      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-332      D        831      Description: The data wrap
                               communications test failed.

831-333      D        831      Description: The modem control line test failed.

831-371      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-372      D        831      Description: The data wrap
                               communications test failed.

831-373      D        831      Description: The modem control line test failed.

831-381      D        831      Description: Cannot run the test because
                               the device driver detected a hardware error.

831-382      D        831      Description: The data wrap
                               communications test failed.

831-383      D        831      Description: The modem control line test failed.

831-481      D        D56      Description: Could not do the test
                               because the device driver detected a
                               hardware error.

831-482      D        D56      Description: The data wrap communication test failed.
831-483      D        D56      Description: The modem control line test failed.

831-581      D        831      Description: Could not do the test
                               because the device driver detected a
                               hardware error.

831-582      D        831      Description: The data wrap communication
                               test failed.           
                               
831-583      D        831      Description: The modem control line test failed. 

831-901      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 831     software or hardware.
831-920                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 831; otherwise,
                               suspect a software problem.

831-921      D        831      Description: The adapter failed to configure software

831-922      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 831     software or hardware.
831-924                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 831; otherwise,
                               suspect a software problem.

831-925      D        831      Description: The adapter failed to configure software

831-926      D      software   Description: An unexpected error
                               occurred that can be attributed to
    to                 831     software or hardware.
831-943                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 831; otherwise,
                               suspect a software problem.

832-xxx      G        xxx      I/O Device Internal Error
                               Note: xxx represents the last 3 digits of
                               the SRN.

833-xxx      G        xxx      Description: PCI device address parity
                               error, PCI device data parity error, or
                      296      PCI device abort error. The diagnostics
                               screen indicates the actual error.
                               Note: xxx represents the last 3 digits of
                               the SRN.

836-101       D       836      Description: Cannot run the test
                               because the device driver detected a
                               hardware error.

836-111       D       836      Description: Cannot run test because
                               the device driver detected a hardware error.
                               
836-112       D       836      Description: Unable to determine the
                               type of adapter from the VPD. 
                               
836-113       D       836      Description: The VPD verification test failed.
836-114       D       836      Description: The register verification test failed.
836-115       D       836      Description: The VPD verification test failed.
836-116       D       B54      Description: The 128-port controller line test failed.
836-117       D       684      Description: Remote Async Node test failed.
836-118       D       837      Description: Remote async node test failed.
836-119       F       836      Description: Sync line termination test failed.

836-151       D       837      Description: Cannot run the test
                               because the device driver detected a hardware error.

836-152       D       837      Description: The data wrap communications test failed.
836-153       D       837      Description: The modem control line test failed.

836-154      D        684      Desciption: Cannot run the test because
                               the device driver detected a hardware error.
                               
836-155      D        684      Description: The data wrap communications test failed. 

836-161      D        C22      Description: Cannot run the test
                               because the device driver detected a hardware error.

836-162      D        C22      Description: The data wrap
                               communications test failed.

836-163      D        C22      Description: The modem control line test failed.

836-164      D        D06      Description: The data wrap
                               communication test failed.
                               
836-171      D        259      Description: Cannot run the test
                               because the device driver detected a hardware error.

836-172      D        259      Description: The data wrap
                               communications test failed.
                               
836-173      D        259      Description: The modem control line test failed.

836-174      D        263      Description: Cannot run the test because
                               the device driver detected a hardware
                               error while running the Printer/Terminal
                               cable wrap test.

836-175      D        263      Description: The data wrap
                               communications test failed while running
                               the Printer/Terminal cable wrap test.

836-181      D        261      Description: Cannot run the test
                               because the device driver detected a
                               hardware error.

836-182      D        261      Description: The data wrap
                               communications test failed.
                               
836-183      D        261      Description: The modem control line test failed.

836-251      D        836      Description: Cannot run the test
                               because the device driver detected a
                               hardware error.
                               
836-252      D        836      Description: The data wrap
                               communications test failed. 
                               
836-253      D        836      Description: The modem control line test failed.

836-254      D        836      Description: Cannot run the test because
                               the device driver detected a hardware
                               error while running the Remote Async Node
                               wrap test.

836-255      D        836      Description: The data wrap
                               communications test failed while running
                               the Remote Async Node wrap test.

836-271      D        836      Description: Cannot run the test
                               because the device driver detected a
                               hardware error.
                               
836-272      D        836      Description: The data wrap
                               communications test failed.
                               
836-273      D        836      Description: The modem control line test failed.

836-274      D        836      Description: Cannot run the test because
                               the device driver detected a hardware
                               error while running the Printer/Terminal
                               cable wrap test.

836-275      D        836      Description: The data wrap
                               communications test failed while running
                               the Printer/Terminal cable wrap test.
                               
836-281      D        836      Description: Cannot run the test
                               because the device driver detected a
                               hardware error.
                               
836-282      D        836      Description: The data wrap communication test failed.  
836-283      D        836      Description: The modem control line test failed.

836-481      D        D56      Description: Could not do the test
                               because the device driver detected a
                               hardware error.

836-482      D        D56      Description: The data wrap communication test failed.
836-483      D        D56      Description: The modem control line test failed.

836-901      D      software   Description: An unexpected error
    to                         occurred that can be attributed to
836-920               836      software or hardware.
                               Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 836; otherwise,
                               suspect a software problem.

836-921      D        836      Description: The adapter failed to configure software

836-922      D      software   Description: An unexpected error
   to                          occurred that can be attributed to
836-924               836      software or hardware.
                               Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 836; otherwise,
                               suspect a software problem.

836-925      D        836      Description: The adapter failed to configure software

836-926      D      software   Description: An unexpected error
     to                        occurred that can be attributed to
836-943                        software or hardware.
                               Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 836; otherwise,
                               suspect a software problem.

840-212      D        840      Description: FIFO empty bit set.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                      221      Problems Isolation Procedure".

840-213      D        840      Description: FIFO empty bit clear.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                      221      Problems Isolation Procedure".

840-214      D        840      Description: FIFO full bit set.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-215      D        840      Description: FIFO full bit clear.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                              
840-216      D        840      Description: FIFO data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                         
840-217      D        840      Description: SCSI FIFO data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure"
                              
840-218      D        840      Description: SCSI FIFO underflow.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                         
840-219      D        840      Description: SCSI parity error.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                         
840-220      D        840      Description: SCSI FIFO flags error.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                         
840-221      D        840      Description: Miscompare during the
                               write/read of the configuration register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-222      D        840      Description: Error during the write/read
                               of the memory register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-223      D        840      Description: Miscompare during the
                               write/read of the memory I/O register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-224      D        840      Description: Error reading the PCI configuration register.       
840-225      D        840      Description: Adapter POST failed.   

840-230      D        D50      Description: Arbitration test failed.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure"..
                               
840-231      D        D50      Description: Function could not complete.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-232      D        D50      Description: SCSI bus data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                             
840-240      D        840      Description: No terminal power.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                               
840-301      D        840      Description: Configuration open failed
                               for parent bus.  D50  software
                                 
840-700      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure.software
                               
840-701      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software
                               
840-702      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure.software
                               
840-703      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software
                               
840-704      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software
                               
840-705      G        840      Description: Error log analysis
                               indicates a PCI SCSI adapter failure.software
                               
840-800      G        746      Description: Error log analysis
                               indicates a PCI SCSI adapter PTC failure.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

840-802      G        840      Description: Error log analysis
                               indicates a PCI SCSI bus failure.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

844-XXX      D        844      Description: A 7135 controller problem series is indicated.
                               Action: Use 7135 documentation.

845-XXX      D        845      Description: A 7135 DASD drawer problem series
                               is indicated.  
                               Action: Use 7135 documentation.

846-XXX      D        846      Description: A 7135 DASD drawer problem series
                               is indicated.
                               Action: Use 7135 documentation.

868-110      D        221      Description: The adapter diagnostic
                               subcommand test failed.

868-130      D        279      Description: The adapter fuse test failed.
868-140      D        868      Description: The wrap test failed.
868-150      D        868      Description: The BCR registers write/read test failed.
868-160      D        868      Description: The POS registers write/read test failed.
868-170      D        868      Description: The internal/external reset test failed.

868-180      D        279      Description: The adapter command timed out. 868
                               Note: Check the fuse before replacing.
   
868-190      D        221      Description: A software error was caused
                               by a hardware failure.

868-191      G        868      Description: Analysis of the error log
                               indicates a problem with the hardware.

868-192      G        221      Description: Analysis of the error log
                               indicates a problem with the hardware.

868-193      G        279      Description: Analysis of the error log
                               indicates a problem with the hardware.

868-194      G        868      Description: Analysis of the error log
                               indicates a problem with the hardware.

868-200      D        868      Description: ROM CRC error.
868-201      D        868      Description: Adapter RAM error.
868-202      D        868      Description: The control logic failed.
868-203      D        868      Description: The control logic failed.
868-204      D        868      Description: The control logic failed.
868-205      D        868      Description: The control logic failed.
868-206      D        868      Description: Diagnostics completed with a previous error.

868-211      D        279      Description: The device failed to
                               configure. 868  software

868-212      D        221      Description: FIFO empty bit set.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-213      D        221      Description: FIFO empty bit clear.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-214      D        221      Description: FIFO full bit set.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-215      D        221      Description: FIFO full bit clear.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-216      D        221      Description: FIFO data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-217      D        221      Description: SCSI FIFO data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-218      D        221      Description: SCSI FIFO underflow.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-219      D        221      Description: SCSI parity error.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-220      D        221      Description: SCSI FIFO flags error.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-221      D        221      Description: Miscompare during the
                               write/read of the configuration register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-222      D        221      Description: Error during the write/read
                               of the memory register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-223      D        221      Description: Miscompare during the
                               write/read of the memory I/O register.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-224      D        221      Description: Error reading the PCI
                               configuration register.
                               Action: Use Chapter 12. "MAP 0210:
                               General Problem Resolution".

868-225      D        221      Description: POST failed.

868-230      D        D50      Description: Arbitration test failed.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                            
868-231      D        D50      Description: Function could not complete.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-232      D        D50      Description: SCSI bus data miscompare.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".
                               
868-240      D        221      Description: No terminal power.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-301      D        868      Description: Configuration open failed
                               for parent bus.      D50    software
                               
868-700      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software

868-701      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software

868-702      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software

868-703      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure.  software

868-704      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure. software

868-705      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter failure.software

868-800      G        868      Description: Error log analysis
                               indicates a PCI SCSI adapter PTC failure.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

868-802      G        868      Description: Error log analysis
                               indicates a PCI SCSI bus failure.
                               Action: Go to Chapter 7. "MAP 0050: SCSI
                               Problems Isolation Procedure".

887-101      D        887      Description: POS register test failed.
887-102      D        887      Description: I/O register test failed.
887-103      D        887      Description: Local RAM test failed.
887-104      D        887      Description: Vital Product Data (VPD)failed.
887-105      D        887      Description: LAN coprocessor internal tests failed.
887-106      D        887      Description: Internal loopback test failed.
887-107      D        887      Description: External loopback test failed.
887-108      D        887      Description: External loopback test failed.
887-109      D        887      Description: External loopback parity tests failed.
887-110      D        887      Description: External loopback fairness test failed.
887-111      D        887      Description: External loopback fairness and parity tests failed.
887-112      D        887      Description: External loopback (twisted pair) test failed.
887-113      D        887      Description: External loopback (twisted pair) parity test failed.
887-114      D        887      Description: Ethernet loopback (twisted pair) fairness test failed.
887-115      D        887      Description: External loopback (twisted pair) fairness and parity tests failed.
887-116      D        887      Description: Twisted pair wrap data failed ).
887-117      D        887      Description: Device configuration fails.software
887-118      D        887      Description: Device driver indicates a hardware problem.
887-120      D        887      Description: Device driver indicates a hardware problem.
887-121      D        B08      Description: Ethernet transceiver test failed.
887-122               B09      Description: Ethernet 10 Base-2 transceiver test failed.
887-123      D        887      Description: Internal loopback test failed.
887-124      G        887      Description: Error log indicates a hardware problem.software
887-125      G        887      Description: Fuse test failed.
887-202      D        887      Description: Vital product data test failed.
887-203      D        887      Description: Vital product data test failed.
887-209      D        887      Description: RJ-45 converter test failed.
887-304      D        887      Description: Coprocessor internal test failed.
887-305      D        887      Description: Internal loopback test failed.
887-306      D        887      Description: Internal loopback test failed.
887-307      D        887      Description: External loopback test failed.
   
887-319      D        887      Description: Device driver indicates a
                               hardware failure.  software

887-400      D        887      Description: Fuse test failed.
887-401      D        887      Description: Circuit breaker for Ethernet test failed.
887-402      D        B09      Description: Ethernet 10 Base-2 transceiver test failed.
887-403      D        B08      Description: Ethernet 10 Base-T transceiver test failed. 
887-404      D        C29      Description: RJ-45 converter test failed.

887-405      F      Ethernet   Description: Rerun diagnostics in
                               advanced mode for accurate problem
                    network    determination.  887

89c-111      D        89c      Description: Unable to reserve device.
89c-112      D        89c      Description: Unable to do configuration.
89c-113      D        89c      Description: Unable to open the device driver.   
89c-121      D        89c      Description: The CD-ROM drive indicates an error.
89c-122      D        89c      Description: The CD-ROM drive indicates an error.
89c-123      D        89c      Description: The CD-ROM drive indicates an error.
89c-125      D        89c      Description: The CD-ROM drive indicates an error.
89c-126      D        89c      Description: The CD-ROM drive indicates an error.
89c-127      D        89c      Description: The CD-ROM drive indicates an error.
89c-128      D        89c      Description: The CD-ROM drive indicates an error.
89c-129      D        89c      Description: The CD-ROM drive indicates an error.
89c-150      D       Media     Description: A media error was detected.
89c-151      D        89c      Description: A command timeout was detected.
89c-152      D        89c      Description: A command reservation conflict was detected.
89c-162      D        89c      Description: The CD-ROM drive indicates an error.
89c-171      D        89c      Description: Unable to reserve device.
89c-172      D        89c      Description: Unable to do configuration.
89c-173      D        89c      Description: Unable to open device driver.
89c-175      D        89c      Description: The CD-ROM drive indicates an error.
89c-198      D        89c      Description: Undefined error detected.
89c-199      D        89c      Description: Undefined error detected.
89c-211      D        89c      Description: The LED test failed.
89c-281      D        89c      Description: No tone during audio test.
89c-301      G        89c      Description: Errors found during ELA.
89c-302      G        89c      Description: Errors found during ELA.
900-001      D        900      Description: "NO" to color panel
900-002      D        900      Description: "NO" to cursor panel
900-007      D     Info code   Description: The EMC_SCROLLING_17_H_TEST failed 
900-009      D     Info code   Description: The EMC_SCROLLING_21_H_TEST failed
900-064      D        900      Description: TRIO64V+_TIMEOUT
900-101      D        900      Description: Color miscompare
900-102      D        900      Description: Clipping error
900-103      D        900      Description: Rectangle fill test failed
900-128      D      software   Description: MALLOC_ERROR
900-161      D      software   Description: Loop count value in rules file is zero   
900-191      D        900      Description: Red screen error
900-193      D        900      Description: Green screen error
900-1FF      D        900      Description: Rectangle fill test failed
900-201      D        900      Description: Color miscompare
900-202      D        900      Description: Clipping error
900-203      D        900      Description: Image transfer across Plane Test failed  
900-211      D      software   Description: INTERNAL_ERROR_DATA_SIZE
900-212      D      software   Description: INTERNAL_ERROR_NO_ACCESS
900-215      D        900      Description: Black screen error
900-217      D        900      Description: 9 x 7 Cross hatch grid failed.
900-233      D      software   Description: OPEN_RCM_ERROR
900-234      D      software   Description: IOCTL_GSC_HANDLE_FAILED
900-235      D      software   Description: AIXGSC_MAKE_GP_FAILED
900-236      D      software   Description: AIXGSC_UNMAKE_GP_FAILED
900-237      D      software   Description: DEVICE_BUSY_ERROR
900-241      D     Info code   Description: The SCROLLING_17_H_TEST failed.
900-263      D     Info code   Description: The EMC_SCROLLING_21_H_TEST failed
900-2FF      D        900      Description: Image transfer across Plane Test failed  
                    
900-301      D        900      Description: A write of "0x00" to the
                               palette register failed

900-302      D        900      Description: A write of "0x15" to the
                               palette register failed

900-303      D        900      Description: A write of "0x2A" to the
                               palette register failed

900-304      D        900      Description: A write of "0x3F" to the
                               palette register failed

900-305      D        900      Description: The test of the palette
                               registers failed

900-3FF      D        900      Description: The test of the palette
                               registers failed

900-401      D        900      Description: Frame buffer base address inconsistent
900-402      D        900      Description: VRAM inaccessible
900-403      D        900      Description: Miscompare found in VRAM
900-404      D        900      Description: The test of the VRAM failed
900-447      D        900      Description: Green screen error
900-449      D        900      Description: Blue Screen error
900-471      D        900      Description: 9 x 7 Cross hatch grid failed.
900-473      D        900      Description: 11 x 9 Cross hatch grid failed.
900-495      D     Info code   Description: The SCROLLING_17_H_TEST failed.
900-497      D     Info code   Description: The SCROLLING_21_H_TEST failed.
900-4FF      D        900      Description: The test of the VRAM failed
900-501      D        900      Description: Color miscompare
900-502      D        900      Description: Clipping error
900-503      D        900      Description: Direct Frame Buffer test failed 
900-5FF      D        900      Description: Direct Frame Buffer test failed
900-601      D        900      Description: Video Stream Register test failed
900-602      D        900      Description: Video Stream hardware test failed
900-6FF      D        900      Description: Video Stream hardware test failed
900-701      D        900      Description: 0 Degree Short Stroke Draw failed
900-702      D        900      Description: 45 Degree Short Stroke Draw failed
   
900-703      D        900      Description: Blue Screen error, or 90
                               Degree Short Stroke Draw failed

900-704      D        900      Description: 135 Degree Short Stroke
                               Draw failed

900-705      D        900      Description: White screen error, or 180
                               Degree Short Stroke Draw failed

900-706      D        900      Description: 225 Degree Short Stroke
                               Draw failed

900-707      D        900      Description: 270 Degree Short Stroke
                               Draw failed

900-708      D        900      Description: 315 Degree Short Stroke
                               Draw failed

900-709      D        900      Description: Short Stroke Vector
                               Function test failed

900-727      D        900      Description: 11 x 9 Cross hatch grid failed.
900-750      D     Info code   Description: The SCROLLING_21_H_TEST failed.
900-753      D     Info code   Description: The EMC_SCROLLING_17_H_TEST failed
900-7FE      D        900      Description: Short Stroke Vector Function test failed
900-7FF      D      software   Description: Bad vector detected 900 227
900-801      D        900      Description: Color for PatBlt thru screen failed      
900-802      D        900      Description: Clipping for PatBlt thru screen failed        
900-803      D        900      Description: Color for PatBlt Across screen failed
900-804      D        900      Description: Clipping for PatBlt Across screen failed    

900-805      D        900      Description: Pattern Fill Across the
                               Plane test failed 

900-8FF      D        900      Description: Pattern Fill Across the
                               Plane test failed 

900-901      D        900      Description: Color miscompare of white boxes detected
900-902      D        900      Description: Clipping error of white boxes detected
900-903      D        900      Description: Color miscompare of color bars detected
900-904      D        900      Description: Clipping error of white boxes detected
900-905      D        900      Description: Color miscompare of white boxes detected 
900-906      D        900      Description: Clipping error of white boxes detected 
900-907      D        900      Description: Color miscompare of white boxes detected
900-908      D        900      Description: Clipping miscompare of white boxes detected
900-909      D        900      Description: The Area fill test (color bars) failed 
900-9FF      D        900      Description: The Area fill test (color bars) failed
900-937      D        900      Description: Red screen error    
900-959      D        900      Description: White screen error  
900-961      D        900      Description: Black screen error  227

900-A01      D        900      Description: Color miscompare of
                               horizontal top line 227

900-A02      D        900      Description: Clipping error of
                               horizontal top line    

900-A03      D        900      Description: Color miscompare of
                               vertical right line    

900-A04      D        900      Description: Clipping error of vertical
                               right line     

900-A05      D        900      Description: Color miscompare of
                               horizontal bottom line  

900-A06      D        900      Description: Clipping error of
                               horizontal bottom line  

900-A07      D        900      Description: Color miscompare of
                               vertical left line  

900-A08      D        900      Description: Clipping error of vertical
                               left line      
                               
900-A09      D        900      Description: Color miscompare of
                               horizontal center line   

900-A0A      D        900      Description: Clipping error of
                               horizontal center line 

900-A0B      D        900      Description: Color miscompare of
                               vertical center line 

900-A0C      D        900      Description: Clipping error of vertical center line
900-A0D      D        900      Description: Reserved   
900-A0F      D        900      Description: Reserved   
900-A10      D        900      Description: Color miscompare of textured top line
900-A11      D        900      Description: Clipping error of textured top line
900-A12      D        900      Description: Line Drawing Function test failed
900-AFF      D        900      Description: Line Drawing Function test failed
900-B01      D        900      Description: Rectangle Area Color miscompare detected
900-B02      D        900      Description: Rectangle Area Clip error detected
       
900-B03      D        900      Description: Clipped Area Horizontal
                               color miscompare (background line color wrong)
                               
900-B04      D        900      Description: Clipped Area Horizontal
                               clip miscompare (clip of background line wrong)
                                 
900-B05      D        900      Description: Clipped Area Vertical color
                               miscompare (background line color wrong) 227

900-B06      D        900      Description: Clipped Area Vertical clip
                               error (clip of background line wrong)  227

900-B07      D        900      Description: The clipping function test failed.
900-BFF      D        900      Description: The clipping function test failed.
900-C01      D        900      Description: The BIOS read failed. 227
900-C02      D        900      Description: The BIOS function test failed.
900-CFF      D        900      Description: The BIOS function test failed.
900-D01      D        900      Description: The HW cursor function test failed.
900-DFF      D        900      Description: The HW cursor function test failed. 

901-xxx                        Description: Vendor SCSI device problem.
                               Refer to the service documentation for
                               this device.

902-xxx                        Description: Vendor display problem.
                               Refer to the service documentation for
                               this display.

903-xxx                        Description: Vendor Async device
                               problem. Refer to the service
                               documentation for this device.

904-xxx                        Description: Vendor Parallel device
                               problem. Refer to the service
                               documentation for this device.

905-xxx                        Description: Vendor device problem.
                               Refer to the service documentation for
                               this device.

908-001      D        908      Description: Invalid function request or
   to                 C33      bad parameters passed.
908-010               C48

908-016      D        908      Description: MCIC failed reading header.
    to
908-019

908-020      D        C33      Description: Error closing 7250 DD.
908-111      D        908      Description: Loader check sum error.
908-112      D        C33      Description: DMA failed to complete a transfer.
908-113      D        908      Description: Errors in loading ASCII registers.

908-114      D        C33      Description: Errors in loading ASCII
   to                 908      registers.
908-118               C36

908-120      D        908      Description: DMA transfer or PFCA data
   to                 C33      error.
908-150               C36


908-151      D        908      Description: SPAN board error.
   to
908-158
   
908-160      D        908      Description: 7250 is not available. C33 System  C36

908-200      D        C33      Description: GPSS board failure.
   to                 908
908-254               C36

908-255      D        C33     Description: CP NMI bus timeout
                      C34     interrupt error. 908   C48
                      
908-256      D        C33     Description: GPSS board failure.
   to                 908
908-454               C36

908-455      D        C33      Description: CP NMI bus timeout
                      908     interrupt error. C34   C48

908-456      D        C33      Description: GPSS board failure.
   to                 908
908-699               C36

908-700      D        C34      Description: BLT or RATTLER error.
   to                 C33
908-766               C48

908-767      D        C35      Description: VOO feature error.
   to                 C34
908-769               C44

908-770      D        C34      Description: RSS BIST failure.
   to                 C33
908-799               C48

908-800      D        C46      Description: Base 16M CHAP0 SIMM bad.
908-801      D        C45      Description: RSS base 12M CHAP0 SIMM bad
908-802      D        C46      Description: RSS AG 16M CHAP0 SIMM bad
908-803      D        C45      Description: RSS AG 12M CHAP0 SIMM bad
908-804      D        C47      Description: RSS TX 16M CHAP0 SIMM bad
908-805      D        C46      Description: Base 16M CHAP 1 SIMM bad
908-806      D        C45      Description: RSS base 12M CHAP1 SIMM bad
908-807      D        C46      Description: RSS AG 16M CHAP1 SIMM bad
908-808      D        C45      Description: RSS AG 12M CHAP1 SIMM bad
908-809      D        C47      Description: RSS TX 16M CHAP1 SIMM bad
908-810      D        C46      Description: RSS base 16M CHAP2 SIMM bad
908-811      D        C45      Description: RSS base 12M CHAP2 SIMM bad
908-812      D        C46      Description: RSS AG 16M CHAP2 SIMM bad
908-813      D        C45      Description: RSS AG 12M CHAP2 SIMM bad
908-814      D        C47      Description: RSS TX 16M CHAP2 SIMM bad
908-815      D        C46      Description: RSS base 16M CHAP3 SIMM bad
908-816      D        C45      Description: RSS base 12M CHAP3 SIMM bad
908-817      D        C46      Description: RSS AG 16M CHAP3 SIMM bad
908-818      D        C45      Description: RSS AG 12M CHAP3 SIMM bad
908-819      D        C47      Description: RSS TX 16M CHAP3 SIMM bad
908-820      D        C46      Description: RSS base 16M CHAP4 SIMM bad
908-821      D        C45      Description: RSS base 12M CHAP4 SIMM bad
908-822      D        C46      Description: RSS AG 16M CHAP4 SIMM bad
908-823      D        C45      Description: RSS AG 12M CHAP4 SIMM bad
908-824      D        C47      Description: RSS TX 16M CHAP4 SIMM bad
908-825      D        C34      Description: RSS error.

908-830      D        C34      Description: Multiple SIMMs failed.
    to
908-870

908-871      D        D66      Description: RSS error.
    to
908-899

908-900      D        D66      Description: RSS error.
   to                 C33
908-966               C48

908-967      D        C35      Description: VOO error.
   to                 D66
908-969               C48

908-970      D        D66      Description: RSS error.
   to                 C33
908-999               C48

912-102      D        912      Description: An unrecoverable media error.
912-104      D        912      Description: The motor failed to restart.
912-105      D        912      Description: The drive did not become ready.
912-106      D        912      Description: The electronics card test failed.
912-108      D        912      Description: The bus test failed.
912-110      D        912      Description: The media format is corrupted.
912-112      D        912      Description: The diagnostic test failed.
912-114      D        912      Description: An unrecoverable hardware error.

912-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

912-117      D        912      Description: A write protect error occurred.
912-118      D        912      Description: A SCSI command time-out.   B88
912-120      D        912      Description: A SCSI busy or command error.
912-122      D        912      Description: A SCSI reservation conflict error.
912-124      D        912      Description: A SCSI check condition error.

912-126      D        912      Description: A software error was caused
                               by a hardware failure.

912-128      G        912      Description: The error log analysis
                               indicates a hardware failure.

912-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.912 B88 software

912-130      G        912      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

912-132      D        912      Description: A disk drive hardware error occurred.
912-134      D        B88      Description: The adapter failed to configure.software
   
912-137      D        912      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.   
    
913-102      D        913      Description: An unrecoverable media error.
913-104      D        913      Description: The motor failed to restart.
913-105      D        913      Description: The drive did not become ready.
913-106      D        913      Description: The electronics card test failed.
913-108      D        913      Description: The bus test failed.
913-110      D        913      Description: The media format is corrupted.
913-112      D        913      Description: The diagnostic test failed.
913-114      D        913      Description: An unrecoverable hardware error.

913-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

913-117      D        913      Description: A write protect error occurred.
913-118      D        913      Description: A SCSI command time-out. B88
913-120      D        913      Description: A SCSI busy or command error.
913-122      D        913      Description: A SCSI reservation conflict error.
913-124      D        913      Description: A SCSI check condition error.

913-126      D        913      Description: A software error was caused
                               by a hardware failure. B88
                               
913-128      G        913      Description: The error log analysis
                               indicates a hardware failure.

913-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.  913

913-130      G        913      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

913-132      D        913      Description: A disk drive hardware error occurred.
913-134      D        B88      Description: The adapter failed to configure.software
   
913-137      D        913      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.  D50

914-110      D        914      Description: The Reserve command failed.
914-120      D        914      Description: The Inquiry command failed.
914-130      D        914      Description: The Load command failed. media
914-135      D        914      Description: The Unload command failed.media
914-140      D        914      Description: The Mode Select command failed.
914-150      D        914      Description: The Test Unit Ready command failed.media
914-160      D        914      Description: The Send Diagnostic command failed.media
914-170      D        914      Description: The Read, Write and Compare test failed.media
914-180      D        914      Description: The Load command failed. media
914-185      D        914      Description: The Unload command failed. media
914-190      D        914      Description: The Mode Select command failed.
914-200      D        914      Description: The Test Unit Ready command failed.media
914-210      D        914      Description: The device configuration failed.B88
914-220      D        914      Description: The Release command failed.
914-230      D        914      Description: The Request Sense command failed.
914-240      D        914      Description: The Openx command failed.
914-300      D        914      Description: The device configuration failed.software
914-310      D        B88      Description: SCSI adapter configuration failed.

914-320      G        914      Description: Error log analysis
                               indicates a failure.  media

914-411      D        914      Description: A reservation conflict
    to                         occurred.
914-423               B88      software

914-511      D        914      Description: The drive returned bad or
    to                         non-extended sense data.
914-523               B88

914-611      D        914      Description: An adapter or bus I/O error
   to                          occurred.
914-623               B88      software

914-711      D        914      Description: A device timeout error
    to                         occurred.
914-723               B88      software

915-110      D        915      Description: The Reserve command is corrupted.
915-120      D        915      Description: The Inquiry command failed.
915-130      D        915      Description: The Load command failed. media
915-135      D        915      Description: The Unload command failed. media
915-140      D        915      Description: The Mode Select command failed.
915-150      D        915      Description: The Test Unit Ready command failed.media
915-160      D        915      Description: The Send Diagnostic command failed.
915-169      D        915      Description: The send diagnostic command failed. media

915-170      D        915      Description: The Read, Write and Compare
                               test failed.  B88  media

915-180      D        915      Description: The Load command failed. media
915-185      D        915      Description: The Unload command failed.media
915-190      D        915      Description: The Mode Select command failed.

915-200      D        915      Description: The Test Unit Ready command failed. media
915-210      D        915      Description: The device configuration failed.
915-220      D        915      Description: The Replace command failed.
915-230      D        915      Description: The Request Sense command failed.
915-240      D        915      Description: The Openx command failed.
915-300      D        915      Description: The device configuration failed. software
915-310      D        B88      Description: SCSI adapter configuration failed.
915-320      G        915      Description: Error log analysis indicates a failure. 

915-411      D        915      Description: A reservation conflict
   to                          occurred.
915-423               B88      software

915-511      D        915      Description: The drive returned bad or
    to                         non-extended sense data.
915-523               B88

915-611      D        915      Description: An adapter or bus I/O error
    to                         occurred.
915-623               B88      software

915-711      D        915      Description: A device timeout error
    to                         occurred.
915-723               B88      software

917-102      D        917      Description: An unrecoverable media error.
917-104      D        917      Description: The motor failed to restart. 
917-105      D        917      Description: The drive did not become ready.
917-106      D        917      Description: The electronics card test failed.
917-108      D        917      Description: The bus test failed.
917-110      D        917      Description: The media format is corrupted.
917-112      D        917      Description: The diagnostic test failed.
917-114      D        917      Description: An unrecoverable hardware error.

917-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

917-117      D        917      Description: A write protect error occurred.
917-118      D        917      Description: A SCSI command time-out.  B88
917-120      D        917      Description: A SCSI busy or command error.
917-122      D        917      Description: A SCSI reservation conflict error.
917-124      D        917      Description: A SCSI check condition error.

917-126      D        917      Description: A software error was caused
                               by a hardware failure. B88
                               
917-128      G        917      Description: The error log analysis
                               indicates a hardware failure.

917-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.  software
                               
917-130      G        917      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

917-132      D        917      Description: A disk drive hardware error occurred. 
917-134      D        B88      Description: The adapter failed to configure.software 
917-135      D        917      Description: The device failed to configure.B88 software
917-136      D        917      Description: The certify operation failed.

917-137      D        917      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.

918-102      D        918      Description: An unrecoverable media error.
918-104      D        918      Description: The motor failed to restart.
918-105      D        918      Description: The drive did not become ready.
918-106      D        918      Description: The electronics card test failed.
918-108      D        918      Description: The bus test failed.
918-110      D        918      Description: The media format is corrupted.
918-112      D        918      Description: The diagnostic test failed.
918-114      D        918      Description: An unrecoverable hardware error.

918-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

918-117      D        918      Description: A write protect error occurred.
918-118      D        918      Description: A SCSI command time-out.B88
918-120      D        918      Description: A SCSI busy or command error.
918-122      D        918      Description: A SCSI reservation conflict error.
918-124      D        918      Description: A SCSI check condition error.

918-126      D        918      Description: A software error was caused
                               by a hardware failure.        B88

918-128      G        918      Description: The error log analysis
                               indicates a hardware failure.

918-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.  918 software
                               
918-130      G        918      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

918-132      D        918      Description: A disk drive hardware error occurred.
918-134      D        B88      Description: The adapter failed to configure.software
918-135      D        918      Description: The device failed to configure.
918-136      D        918      Description: The certify operation failed.

918-137      D        918      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.
                                                     
921-101      D        821      Description: An unexpected adapter error occurred.

921-102      D        921      Description: An unexpected device or
                               adapter error occurred. 821
                              
921-103      D        921      Description: The keyboard reset failed.
921-104      D        921      Description: Unknown keyboard.
921-105      D        921      Description: The keyboard light on test failed.
921-106      D        921      Description: The keyboard light off test failed.
921-201      D        821      Description: An unexpected adapter error occurred.

921-202      D        921      Description: An unexpected device or
                                 adapter error occurred.  821
921-203      D        921      Description: The read keyboard ID test failed.
921-204      D        921      Description: The keyboard layout ID test failed.
921-205      D        921      Description: The keyboard echo test failed.
921-206      D        921      Description: The select scan code set test failed.
921-301      D        821      Description: An unexpected adapter error occurred.

921-302      D        921      Description: An unexpected device or
                               adapter error occurred.

921-303      D        921      Description: An error occurred in
                               turning on the lamps.

921-304      D        921      Description: An error occurred in
                               turning off the lamps.

921-401      D        821      Description: An unexpected adapter error occurred.

921-402      D        921      Description: An unexpected device or
                               adapter error occurred.     821
                               
921-403      D        921      Description: Unable to recognize the keyboard.
921-404      D        921      Description: The keyboard is failing. 821
921-501      D        821      Description: An unexpected adapter error occurred.

921-502      D        921      Description: An unexpected device or
                               adapter error occurred.            821
                                 
921-503      D        921      Description: The auto-click cannot be disabled.
921-504      D        921      Description: The auto-click cannot be enabled.
921-505      D        921      Description: Unable to recognize the keyboard.
921-601      D        821      Description: An unexpected adapter error occurred.
921-602      D        921      Description: An unexpected device or adapter error occurred.
921-603      D        921      Description: The speaker test failed.
921-701      D        921      Description: Error configuring the device. 821

921-901      G        821      Description: The error log analysis
                               indicates an adapter failure.

921-902      G        921      Description: The error log analysis
                               indicates a device failure.    821

921-903      G        921      Description: The error log analysis
                               indicates an unknown failure.   821
                                 
922-101      D        821      Description: An unexpected adapter error occurred.

922-102      D        922      Description: An unexpected device 
                               or adapter error occurred.  821

922-103      D        922      Description: The keyboard reset failed.821
922-104      D        922      Description: Unknown keyboard.
922-105      D        922      Description: The keyboard light on test failed.
922-106      D        922      Description: The keyboard light off test failed.
922-201      D        821      Description: An unexpected adapter error occurred.

922-202      D        922      Description: An unexpected device or adapter error occurred.
922-203      D        922      Description: The read keyboard id test failed.
922-204      D        922      Description: The keyboard layout id test failed.
922-205      D        922      Description: The keyboard echo test failed.
922-206      D        922      Description: The select scan code set test failed.
922-301      D        821      Description: An unexpected adapter error occurred.

922-302      D        922      Description: An unexpected device or
                               adapter error occurred.  821

922-303      D        922      Description: An error occurred in
                               turning on the lamps.

922-304      D        922      Description: An error occurred in
                               turning off the lamps.

922-401      D        821      Description: An unexpected adapter error occurred.

922-402      D        922      Description: An unexpected device or
                               adapter error occurred.      821

922-403      D        922      Description: The keyboard is failing.
922-404      D        922      Description: Unable to recognize the keyboard.
922-501      D        821      Description: An unexpected adapter error occurred.

922-502      D        922      Description: An unexpected device or
                               adapter error occurred.        

922-503      D        921      Description: The auto-click cannot be disabled.
922-504      D        922      Description: The auto-click cannot be enabled.
922-505      D        922      Description: Unable to recognize the keyboard.
922-601      D        821      Description: An unexpected adapter error occurred.
  
922-602      D        922      Description: An unexpected device or
                               adapter error occurred. 821

922-603      D        922      Description: The speaker test failed.
922-701      D        922      Description: Error configuring the device.
922-901      G        821      Description: The error log indicates an adapter failed.
922-902      G        922      Description: The error log indicates a device failed. 

922-903      G        922      Description: The error log analysis
                               indicates an unknown failure.  821

923-101      D        821      Description: An unexpected adapter error occurred.

923-102      D        923      Description: An unexpected device or
                               adapter error occurred.  821
                                 
923-103      D        923      Description: The keyboard reset failed. 821
923-104      D        923      Description: Unknown keyboard.
923-105      D        923      Description: The keyboard light on test failed.
923-106      D        923      Description: The keyboard light off test failed.
923-201      D        821      Description: An unexpected adapter error occurred.

923-202      D        923      Description: An unexpected device or
                               adapter error occurred.    821
                               
923-203      D        923      Description: The read keyboard id test failed. 
923-204      D        923      Description: The keyboard layout id test failed.
923-205      D        923      Description: The keyboard echo test failed. 821
923-206      D        923      Description: The select scan code set  test failed.
923-301      D        821      Description: An unexpected adapter error occurred.

923-302      D        923      Description: An unexpected device or
                               adapter error occurred.     821
                                 
923-303      D        923      Description: An error occurred in
                               turning on the lamps.

923-304      D        923      Description: An error occurred in
                               turning off the lamps.

923-401      D        821      Description: An unexpected adapter error occurred.

923-402      D        923      Description: An unexpected device or
                               adapter error occurred.    

923-403      D        923      Description: The keyboard is failing.
923-404      D        923      Description: Unable to recognize the keyboard.
923-501      D        821      Description: An unexpected adapter error occurred.

923-502      D        923      Description: An unexpected device or
                               adapter error occurred.    821
923-503      D        923      Description: The auto-click cannot be disabled.

923-504      D        923      Description: The auto-click cannot be enabled.
923-505      D        923      Description: Unable to recognize the keyboard.
923-601      D        821      Description: An unexpected adapter error occurred.

923-602      D        923      Description: An unexpected device or
                               adapter error occurred.  821

923-603      D        923      Description: The speaker test failed.
922-701      D        923      Description: Error configuring the device.
923-901      G        821      Description: The error log indicates an adapter failed.

923-902      G        923      Description: The error log analysis
                               indicates a device failure.     821
                                 
923-903      G        923      Description: The error log analysis
                               indicates an unknown failure.     821

925-111      D        925      Description: An unexpected device error occurred. 
925-112      D        925      Description: The device disable test failed.
925-113      D        925      Description: Could not reset the device.
925-114      D        925      Description: The read status command failed.  
925-115      D        925      Description: The device test failed.
925-116      D        925      Description: Unknown Mouse type.
925-117      D        925      Description: Mouse wrap mode failed.  823
925-118      D        925      Description: Error setting mouse parameters. 

925-121      D        925      Description: The device test failed.
    to
925-171
   
925-200      D        925      Description: A software error was caused
                               by a hardware failure.      
                               
925-300      G        925      Description: The error log analysis
                               indicates a hardware failure.

925-301      G        925      Description: The error log analysis
                               indicates a hardware failure. 823

926-104      D        926      Description: Input device cable is not
                               attached.  159
                                
926-111      D        824      Description: Adapter error.

926-112      D        926      Description: Device, adapter or tablet
   to                          reset failed. 824
926-115                       

926-116      D        159      Description: The input device cable is not attached.
926-119      D        188      Description: The input device cable is not attached.
926-121      D        824      Description: Adapter error.
926-131      D        824      Description: Adapter error.926

926-132      D        926      Description: Device or adapter error.
    to
926-135
   
926-141      D        824      Description: Adapter error. 926

926-142      D        926      Description: Device or adapter error.
   to
926-161
   
926-162      D        159      Description: Device or adapter error.926
926-163      D        159      Description: Error in turning off input device LED.
926-164      D        159      Description: Error in turning off input device LED.
926-165      D        159      Description: The input device cable is not attached.
926-166      D        188      Description: Device or adapter error. 926
926-167      D        188      Description: Error in turning off input device LED.
926-168      D        188      Description: Error in turning on input device LED.
926-169      D        188      Description: The input device cable is not attached.
926-172      D        159      Description: Device or adapter error.  926
926-173      D        159      Description: Error in turning off input device switch.
926-174      D        159      Description: Error in turning on input device switch. 
926-175      D        159      Description: The input device cable is not attached.
926-176      D        188      Description: Device or adapter error.   926
926-177      D        188      Description: Error in turning off input device switch. 
926-178      D        188      Description: Error in turning on input device switch.
926-179      D        188      Description: The input device cable is not attached.
926-181      D        824      Description: Adapter error.   926
926-182      D        159      Description: Device or adapter error.  926
926-183      D        159      Description: Error in incremental data mode test.
926-184      D        159      Description: The input device cable is not attached.
926-186      D        188      Description: Device or adapter error.  926
926-187      D        188      Description: The incremental data mode test failed.
926-188      D        188      Description: The input device cable is not attached.
926-203      D        926      Description: Error in disabling tablet. 824
926-204      D        926      Description: Error in enabling tablet. 824>
926-207      D        926      Description: Enabled/disabled test failed.
926-208      D        926      Description: Enabled/disabled test failed.
926-221      D        824      Description: Adapter error.
926-222      D        926      Description: Device or adapter error.824
926-225      D        159      Description: The input device cable is not attached.   
926-229      D        188      Description: The input device cable is not attached.
926-271      D        926      Description: Adapter error.
926-272      D        159      Description: Device or adapter error.
926-273      D        159      Description: Error in input device switch test.
926-274      D        159      Description: The input device cable is not attached.
926-276      D        188      Description: Device or adapter error. 926
926-277      D        188      Description: Error in input device switch test.
926-278      D        188      Description: Input device cable is not attached.
926-281      D        824      Description: Adapter error.  926
926-282      D        159      Description: Device or adapter error.  926
926-283      D        159      Description: Error in incremental data mode test.
926-284      D        159      Description: The input device cable is not attached.
926-286      D        188      Description: Device or adapter error.   926
926-287      D        188      Description: Error in incremental data mode test.
926-288      D        188      Description: The input device cable is not attached.
927-104      D        927      Description: The input device cable is not attached.
927-111      D        824      Description: Adapter error.
927-112      D        927      Description: Device or adapter error.824
927-113      D        927      Description: Tablet reset failed.  824
927-114      D        927      Description: The read configuration test failed.824
927-115      D        927      Description: The read status test failed.  824
927-116      D        159      Description: The input device cable is not attached.
927-119      D        188      Description: The input device cable is not attached.
927-121      D        824      Description: Adapter error.
927-122      D        927      Description: Device or adapter error.   824
927-125      D        927      Description: The input device cable is not attached.
927-131      D        824      Description: Adapter error.   927
927-132      D        927      Description: Device or adapter error.
927-133      D        927      Description: The set conversion mode test failed.
927-134      D        927      Description: The set resolution test failed.
927-135      D        927      Description: The read status test failed.
927-141      D        824      Description: Adapter error.    927
927-142      D        927      Description: Device or adapter error.
927-143      D        927      Description: Error in tablet indicator.
927-161      D        927      Description: Adapter error.
927-162      D        159      Description: Device or adapter error.  927
927-163      D        159      Description: Error in turning off input device LED.927
927-164      D        159      Description: Error in turning on input device LED. 927
927-165      D        159      Description: The input device cable is not attached.
927-166      D        188      Description: Device or adapter error.   927
927-167      D        188      Description: Error in turning off input device LED.
927-168      D        188      Description: Error in turning on input device LED.   
927-169      D        188      Description: The input device cable is not attached.
927-171      D        927      Description: Adapter error.
927-172      D        159      Description: Device or adapter error.   927
927-173      D        159      Description: Error in turning off input device switch.  
927-174      D        159      Description: Error in turning on input device switch.
927-175      D        159      Description: The input device cable is not attached.
927-176      D        188      Description: Device or adapter error. 927
927-177      D        188      Description: Error in turning off input device switch.
927-178      D        188      Description: Error in turning on input device switch.
927-179      D        188      Description: The input device cable is not attached.
927-181      D        824      Description: Adapter error.  927
927-182      D        159      Description: Device or adapter error.  927
927-183      D        159      Description: Error in incremental data mode test. 
927-184      D        159      Description: The input device cable is not attached.
927-186      D        188      Description: Device or adapter error.  927
927-187      D        188      Description: Error in incremental data mode test.
927-188      D        188      Description: The input device cable is not attached.
927-203      D        927      Description: Error in disabling tablet. 824
927-204      D        927      Description: Error in enabling tablet.  824
927-221      D        824      Description: Adapter error.
927-222      D        927      Description: Device or adapter error.  824
927-225      D        159      Description: The input device cable is not attached.
927-229      D        188      Description: The input device cable is not attached.
927-271      D        927      Description: Adapter error.
927-272      D        159      Description: Device or adapter error. 927
927-273      D        159      Description: Error in input device switch test.
927-274      D        159      Description: The input device cable is not attached.
927-276      D        188      Description: Device or adapter error.  927
927-277      D        188      Description: Error in input device switch test. 
927-278      D        188      Description: The input device cable is not attached.
927-281      D        824      Description: Adapter error. 927
927-282      D        159      Description: Device or adapter error.  
927-283      D        159      Description: Error in incremental data mode test.
927-284      D        159      Description: The input device cable is not attached.
927-286      D        188      Description: Device or adapter error.  927
927-287      D        188      Description: Error in incremental data mode test.
927-288      D        188      Description: The input device cable is not attached.
929-201      D        929      Description: Failed to register input ring
929-202      D        929      Description: Unable to read event from the device
929-203      D        929      Description: Unable to communicate with the device.
929-204      D        929      Description: Cannot set the device granularity
929-210      D        929      Description: Device or adapter failure
929-212      D        929      Description: Cannot set the device to HIGH granularity
929-213      D        929      Description: Cannot set the device to LOW granularity
929-299      D       software  Description: Error unconfiguring the device  929
929-301      D       software  Description: Error configuring the device 929
930-201      D        930      Description: Device or adapter failure
930-210      G        930      Description: Unable to turn the lights on
930-220      G        930      Description: Unable to turn the lights off hardware failure.
930-230      D        930      Description: Unable to turn the lights off
930-241      D        930      Description: Unable to turn a single light on
930-242      D        930      Description: Device or adapter failure
930-243      D        930      Description: Device or adapter failure
930-261      D        930      Description: Cable test failed
930-262      D        930      Description: Cable test failed
930-299      D    software     Description: Error unconfiguring the device
930-301      D    software     Description: Error configuring the device0

935-101      D        935      Description: The diskette-drive select
   to                          or deselect test failed.
935-102

935-103      D        935      Description: The diskette failed.
    to
935-107            

935-108      D        935      Description: The diskette read test failed.

935-109      D        935      Description: The read/write on the
  to                           diskette drive failed.
935-110

935-111      D        935      Description: A diskette drive test
     to                        failed.
935-114

935-115      D        935      Description: The diskette drive test
    to                         failed.
935-121               

935-122      G        935     Description: The error log analysis
                              indicates a hardware failure.  828
                              
935-123      G        935      Description: The error log analysis
                               indicates a hardware failure.

935-124      D        935      Description: Unable to configure the
                               device.  software
                               
945-102      D        990      Description: 1GB 16-bit SCSI
    to                         differential disk drive problem.
945-114

945-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

945-117      D        990      Description: A write protect error occurred.
945-118      D        990      Description: A SCSI command time-out.B88
   
945-120      D        990      Description: 1GB 16-bit SCSI
    to                         differential disk drive problem.
945-124

945-126      D        990      Description: A software error was caused
                               by a hardware failure. B88

945-128      G        990      Description: The error log analysis
                               indicates a hardware failure.

945-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.945 B88 software

945-130      G        945      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

945-132      D        990      Description: A disk drive hardware error occurred.
945-134      D        B88      Description: The adapter failed to configure. software
945-136      D        990      Description: The certify operation failed.

945-137      D        945      Description: Unit attention condition
                               has occurred on the Send Diagnostic
                               command.D50

946-111      D       946      Description: Cannot run the test
                              because the device driver detected a
                              hardware error.
                              
946-114      D       946      Description: The register verification test failed.

946-121      D       946      Description: Cannot run the test
                              because the device driver detected a
                              hardware error.
                              
946-122      D       946      Description: The data wrap communications test failed. 
946-123      D       946      Description: The modem control line test failed.       

946-131      D       946      Description: Cannot run the test
                              because the device driver detected a
                              hardware error.

946-132      D       946      Description: The data wrap communications test failed.
946-133      D       946      Description: The modem control line test failed.

946-161      D       252      Description: Could not do the test
                              because the device driver detected a
                              hardware error.

946-162      D      252       Description: The data wrap communication test failed.
946-163      D      252       Description: The modem control line test failed.

946-171      D      259       Description: Cannot run the test
                              because the device driver detected a
                              hardware error.

946-172      D      259      Description: The data wrap communications test failed.
946-173      D      259      Description: The modem control line test failed.

946-181      D      261      Description: Cannot run the test
                             because the device driver detected a
                             hardware error.

946-182      D     261       Description: The data wrap communications test failed.
946-183      D     261       Description: The modem control line test failed.

946-271      D     946       Description: Cannot run the test because the device 
                             driver detected a hardware error.
                             
946-272      D     946       Description: The data wrap communication test failed.
946-273      D     946       Description: The modem control line test failed.

946-281      D     946       Description: Cannot run the test
                             because the device driver detected a hardware error.
                             
946-282      D     946        Description: The data wrap communications test failed. 
946-283      D     946        Description: The modem control line test failed.

946-321      D     946        Description: Cannot run the test
                              because the device driver detected a  hardware error.

946-322      D     946        Description: The data wrap communications test failed.
946-323      D     946        Description: The modem control line test failed.

946-331      D     946        Description: Cannot run the test because the 
                              device driver detected a hardware error.

946-332      D     946        Description: The data wrap communications test failed.
946-333      D     946        Description: The modem control line test failed.
946-371      D     946        Description: Cannot run the test
                              because the device driver detected a hardware error.

946-372      D     946        Description: The data wrap communications test failed.
946-373      D     946        Description: The modem control line test failed.

946-381      D     946        Description: Cannot run the test
                              because the device driver detected a hardware error.

946-382      D     946        Description: The data wrap communications test failed.
946-383      D     946        Description: The modem control line test failed.

946-481      D     D56        Description: Could not do the test
                              because the device driver detected a hardware error.

946-482      D     D56        Description: The data wrap communication test failed.
946-483      D     D56        Description: The modem control line test failed.

946-581      D     946        Description: Could not do the test
                              because the device driver detected a hardware error.
                              
946-582      D     946        Description: The data wrap communication test failed.  
946-583      D     946        Description: The modem control line test failed.

946-901      D      software   Description: An unexpected error
   to                          occurred that can be attributed to software or hardware.
946-920                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 946; otherwise,
                               suspect a software problem.

946-921      D        946      Description: The adapter failed to configure software

946-922      D      software   Description: An unexpected error
   to                          occurred that can be attributed to software or hardware.
946-924                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 946; otherwise,
                               suspect a software problem.

946-925      D        946      Description: The adapter failed to configure software

946-926      D      software   Description: An unexpected error
    to                         occurred that can be attributed to software or hardware.
946-943                        Action: Run diagnostics from a source
                               other than from the disk or a network. If
                               the same error occurs or if the original
                               SRN was not obtained from disk or a
                               network based diagnostics, use Chapter
                               12. "MAP 0210: General Problem
                               Resolution" with a FFC of 946; otherwise,
                               suspect a software problem.

950-100      C        192      Description: Power supply problem.
                               Action: Use the service documentation for
                               the portable disk.

950-101      F        2C9      Description: PCI bus was not found.
                               Action: Rerun diagnostics in Advanced
                               Mode for additional problem isolation.
                               
950-102      C        2C9      Description: PCI bus was not found.
950-103      C        2C9      Description: Multiple adapters on bus were not found.
950-105      C        2C9      Description: PCI bus was not found. 221
950-106      C        2C9      Description: PCI bus was not found.

950-107      C        153     Description: The device is not  responding
                      165     Action: For devices located in
                              drawer/deskside units, use the service
                              documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-108      C        201     Description: The device is not
                              responding. Action: For devices located
                      199     in drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      153     unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                      165     Resolution".

950-200      C        203      Description: Power supply problem.
                               Action: Use the service documentation for
                               the external device.
  
950-201      C      SCSI Bus   Description: SCSI bus problem.
                               Action: Refer to MAP 2010 in the 7134
                               High Density SCSI Disk Subsystem
                               Installation and Service Guide.

950-400      C        153      Description: Power supply problem.
                               Action: Use the service documentation for
                               the drawer/tower containing the failing
                               power supply. If the drawer/deskside unit
                               service documentation does not isolate
                               the problem, go to MAP 1520 in the system
                               unit installation and service guide.

950-500      C        152      Description: Power supply problem.
                               Action: Use the service documentation for
                               either the system unit, rack or
                               drawer/deskside unit the missing device
                               is located in.

950-679      C        679     Description: The SCSI Disk Drive is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      190     documentation for the drawer/deskside
                              unit. For all other locations, use
                      199     Chapter 12. "MAP 0210: General Problem
                              Resolution".      152
                              
950-700      C        700     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-701      C        701     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-702      C        702     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-703      C        703     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-704      C        704     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-705      C        705     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-706      C        706     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-707      C        707     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-721      C        721     Description: An unknown drive type is not responding.

950-722      C        722     Description: The device is not  responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-723      C        723     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-724      C        724     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-734      C        734     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-741      C         741     Description: Device does not respond.
                               Action: For devices located in
                       B88     drawer/deskside units, use the service
                               documentation for the drawer/deskside
                       152     units. For all other locations, use
                               Chapter 12. "MAP 0210: General Problem
                               Resolution".

950-772      C        772     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      199     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                      152     Resolution".
                      
950-773      C        773     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-789      C        789     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-792      C        792     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-793      C        793     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-804      C        804     Description: The device is not responding.
                      B88     Action: For devices located in
                              drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
                              unit. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-912      C        912     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-914      C        914     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-915      C        915     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-917      C        917     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-918     C        918     Description: Device does not respond.
                             Action: For devices located in
                     B88     drawer/deskside units, use the service
                             documentation for the drawer/deskside
                     152     units. For all other locations, use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".
                                 
950-935      C        935      Description: Device does not respond.828 52 199   
950-936      C        936      Description: Device does not respond. 828 152

950-951      C        951      Description: Device does not respond.
                               Action: For devices located in
                      B88      drawer/deskside units, use the service
                               documentation for the drawer/deskside
                      152      units. For all other locations, use
                               Chapter 12. "MAP 0210: General Problem
                               Resolution".

950-952      C        952   Description: Device does not respond.
                            Action: For devices located in
                      B88   drawer/deskside units, use the service
                            documentation for the drawer/deskside
                      152   units. For all other locations, use
                            Chapter 12. "MAP 0210: General Problem
                            Resolution".

950-953      C        953   Description: Device does not respond.
                            Action: For devices located in
                      B88   drawer/deskside units, use the service
                            documentation for the drawer/deskside
                      152   units. For all other locations, use
                            Chapter 12. "MAP 0210: General Problem
                            Resolution".

950-954      C        954   Description: Device does not respond.
                             Action: For devices located in
                      B88    drawer/deskside units, use the service
                             documentation for the drawer/deskside
                      152    units. For all other locations, use
                             Chapter 12. "MAP 0210: General Problem
                             Resolution".

950-955      C        955   Description: Device does not respond.
                            Action: For devices located in
                      B88   drawer/deskside units, use the service
                            documentation for the drawer/deskside
                      141   units. For all other locations, use
                            Chapter 12. "MAP 0210: General Problem
                      152   Resolution". If the drawer/deskside unit
                            service documentation does not isolate
                            the problem, go to Chapter 12. "MAP 0210:
                            General Problem Resolution".

950-956      C        956   Description: Device does not respond.
                            Action: For devices located in
                      B88   drawer/deskside units, use the service
                            documentation for the drawer/deskside
                      152   units. For all other locations, use
                            Chapter 12. "MAP 0210: General Problem
                            Resolution".

950-959      C        959   Description: Device does not respond.
                            Action: For devices located in
                      B88   drawer/deskside units, use the service
                            documentation for the drawer/deskside
                      152   units. For all other locations, use
                            Chapter 12. "MAP 0210: General Problem
                            Resolution".

950-960      C        960    Description: Device does not respond. B88 152 
950-968      C        968    Description: Device does not respond. B88 152

950-970      C        970     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-971      C        971     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-972      C        972     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-974      C        974     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-981      C        981     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. Refer to "Drawer/Deskside Unit
                              Documentation" under Service Hints in
                              Chapter 1. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-984      C        984     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-986      C        986     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
  
950-987      C        974     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
   
950-989      C        989     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-990      C        990     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
   
950-991      C        991    Description: Device does not respond.
                     
950-994      C        994     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-995      C        995     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-998      C        998     Description: Device does not respond.
                              Action: For devices located in
                      B88     drawer/deskside units, use the service
                              documentation for the drawer/deskside
                      152     units. For all other locations, use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".

950-xxx      C        xxx     Description: The device does not respond.
  (See note           B88     Action: For devices located in
    in the                    drawer/deskside units, use the service
                      152     documentation for the drawer/deskside
    Action                    units. Refer to "Drawer/Deskside Unit
    col.)                     Documentation" under Service Hints in
                              Chapter 1. For all other locations use
                              Chapter 12. "MAP 0210: General Problem
                              Resolution".
                              Note: If your 950-xxx SRN is listed in
                              this section, use the procedure for that
                              SRN instead of this one. Otherwise, to
                              obtain the FFC substitute the last three
                              digits of the SRN for xxx. (The
                              substituted three digit number is the FFC.)

951-098       J      951     Description: Disk drive indicates an error
951-099       J      951     Description: Disk drive not found.
951-102       D      951     Description: An unrecoverable media error.
951-104       D      951     Description: The motor failed to restart.
951-105       D      951     Description: The drive did not become ready.
951-106       D      951     Description: The electronics card test failed.
951-108       D      951     Description: The bus test failed.
951-110       D      951     Description: The media format is corrupted.
951-112       D      951     Description: The diagnostic test failed.
951-114       D      951     Description: An unrecoverable hardware error.

951-116       D              Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to ensure they are
                             all compatible. If you do not find a
                             problem, call your support person.

951-117       D      951     Description: A write protect error occurred.
951-118       D      951     Description: A SCSI command timeout.
951-120       D      951     Description: A SCSI busy or command error.
951-122       D      951     Description: A SCSI reservation conflict error.
951-124       D      951     Description: A SCSI check condition error.
951-126       D      951     Description: A software error was caused by a hardware failure.
951-128       G      951     Description: The error log analysis indicates a hardware failure.

951-129       G      D50     Description: Error log analysis
                             indicates a SCSI bus problem.951 B88 software

951-130       G      951     Description: Error log analysis
                             indicates a problem reported by the disk
                             drive's self monitoring function.
   
951-132       D      951     Description: A disk drive hardware error occurred.
951-134       D      B88     Description: The adapter failed to configure. software
951-135       D      951     Description: The device failed to configure.software
951-136       D      951     Description: The certify operation failed.

951-137       D      951     Description: Unit attention condition
                             has occurred on the Send Diagnostic command. 

952-098       J      952     Description: Disk drive indicates an error.
952-099       J      952     Description: Disk drive not found.
952-102       D      952     Description: An unrecoverable media error.
952-104       D      952     Description: The motor failed to restart.
952-105       D      952     Description: The drive did not become ready.
952-106       D      952     Description: The electronics card test failed.
952-108       D      952     Description: The bus test failed.
952-110       D      952     Description: The media format is corrupted.
952-112       D      952     Description: The diagnostic test failed.
952-114       D      952     Description: An unrecoverable hardware error.

952-116       D              Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
   
952-117       D      952     Description: A write protect error occurred.
952-118       D      952     Description: A SCSI command timeout.
952-120       D      952     Description: A SCSI busy or command error.
952-122       D      952     Description: A SCSI reservation conflict error.
952-124       D      952     Description: A SCSI check condition error.

952-126       D      952     Description: A software error was
                             caused by a hardware failure.  

952-128       G      952     Description: The error log analysis
                             indicates a hardware failure.
                             
952-129       G      D50     Description: Error log analysis
                             indicates a SCSI bus problem. 952 b88  software
                             
952-130       G      952     Description: Error log analysis
                             indicates a problem reported by the disk
                             drive's self monitoring function.
  
952-132       D      952     Description: A disk drive hardware error occurred.
952-134       D      B88     Description: The adapter failed to configure.software
952-135       D      952     Description: The device failed to configure.Software
952-136       D      952     Description: The certify operation failed.

952-137      D        952    Description: Unit attention condition
                             has occurred on the Send Diagnostic command. D50
                             
953-098      J        953    Description: Disk drive indicates an error.
953-099      J        953    Description: Disk drive not found.
953-102      D        953    Description: An unrecoverable media error.
953-104      D        953    Description: The motor failed to restart.
953-105      D        953    Description: The disk drive did not become ready.
953-106      D        953    Description: The electronics card test failed.
953-108      D        953    Description: The bus test failed.
953-110      D        953    Description: The media format is corrupted.
953-112      D        953    Description: The diagnostic test failed.
953-114      D        953    Description: An unrecoverable hardware  error.

953-116      D               Description: A protocol error.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software to be sure they are
                             all compatible. If you do not find a
                             problem, call your support person.
   
953-117      D       953     Description: A write protect error.
953-118      D       953     Description: A SCSI command timeout.
953-120      D       953     Description: A SCSI busy or command error.
953-122      D       953     Description: A SCSI reservation conflict error.
953-124      D       953     Description: A SCSI check condition error.

953-126      D       953     Description: A software error was
                             caused by a hardware failure. B88
                             
953-128      G       953     Description: The error log analysis
                             indicates a hardware failure.
                             
953-129      G       D50     Description: Error log analysis
                             indicates a SCSI bus problem. 953 B88 software
                             
953-130      G        953    Description: Error log analysis
                             indicates a problem reported by the disk
                             drive's self monitoring function.

953-132      D        953    Description: A disk drive hardware error occurred.
953-134      D        B88    Description: The adapter failed to configure. software
953-135      D        953    Description: The device failed to configure.B88 software
953-136      D        953    Description: The certify operation failed.

953-137      D        953    Description: Unit attention condition
                             has occurred on the Send Diagnostic command.

954-098      J        954    Description: Disk drive indicates an error.
954-099      J        954    Description: Disk drive not found.
954-102      D        954    Description: An unrecoverable media error.
954-104      D        954    Description: Motor failed to restart.
954-105      D        954    Description: The disk drive did not become ready.
954-106      D        954    Description: Electronics card failure.
954-108      D        954    Description: Bus failure.
954-110      D        954    Description: The media format is corrupted.
954-112      D        954    Description: Diagnostic failure.
954-114      D        954    Description: An unrecoverable hardware error.

954-116      D               Description: A protocol error was detected.
                             Action: Check the levels of the device,
                             adapter, diagnostic software, and
                             application software, ensure that they
                             are all compatible. If you do not find a
                             problem, call your support person.

954-117      D        954    Description: Write protect error.
954-118      D        954    Description: SCSI command timeout.
954-120      D        954    Description: SCSI busy/command error.
954-122      D        954    Description: SCSI reservation conflict  error.
954-124      D        954    Description: SCSI check condition error.
954-126      D        954    Description: Software error caused by hardware failure.
954-128      G        954    Description: Error log analysis indicates hardware failure.

954-129      G        D50    Description: Error log analysis
                             indicates a SCSI bus problem.954 B88 software
                             
954-130      G        954    Description: Error log analysis
                             indicates a problem reported by the disk
                             drive's self monitoring function.
    
954-132      D        954    Description: A disk drive hardware error occurred.
954-134      D        B88    Description: The adapter failed to configure.software
954-135      D        954    Description: The device failed to configure. software
954-136      D        954    Description: The certify operation failed.

954-137      D        954    Description: Unit attention condition
                             has occurred on the Send Diagnostic command. D50
                             
955-098      J        955    Description: Disk drive indicates an error.
955-099      J        955    Description: Disk drive not found.
955-102      D        955    Description: A media error was encountered.141

955-104      D        955    Description: The motor failed to restart.
                      141    Action: For devices installed in a
                             drawer/deskside unit, use the
                             drawer/deskside unit documentation. Refer
                             to "Drawer/Deskside Unit Documentation"
                             under Hints in Chapter 1. For other
                             locations, go to MAP 0210. If the
                             electronics card has been exchanged,
                             exchange the adapter first. If the
                             drawer/deskside unit documentation does
                             not isolate the problem, go to MAP 0210.
                                
955-105         D     955     Description: The disk drive did not become ready.
955-106         D     955     Description: The electronics card failed. 141
955-108         D     955     Description: The bus test failed.
955-110         D     955     Description: The media format is corrupted.141
955-112         D     955     Description: The diagnostic test failed. 141
955-114         D     955     Description: An unrecoverable hardware error. 141

955-116         D             Description: A protocol error.
                              Action: Check the levels of the device,
                              adapter, diagnostic software, and
                              application software to be sure they are
                              all compatible. If you do not find a
                              problem, call your support person.
   
955-118      D        955     Description: A SCSI command timeout. B88
955-120      D        955     Description: A SCSI busy or command error.  B88
955-122      D        955     Description: A SCSI reservation conflict error.
955-124      D        955     Description: A SCSI check condition error. B88

955-126      D        955     Description: A software error was
                              caused by a hardware failure.  B88
                
955-128      G        955     Description: The error log analysis
                              indicates a hardware failure.  141

955-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem. 955 B88 software

955-130      G        955      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.
   
955-132      D       955      Description: A disk drive hardware error occurred.
                
955-134      D       B88       Description: The adapter failed to
                               configure.  software
                
955-135      D       955       Description: The device failed to
                               configure. software
                
955-136      D        955      Description: The certify operation failed. 141

955-137      D        955      Description: Unit attention condition
                               has occurred on the Send Diagnostic command. D50
                                 
956-102      D        956      Description: An unrecoverable media error.
956-104      D        956      Description: The motor failed to restart. 
956-105      D        956      Description: The drive did not become   ready.
956-106      D        956      Description: The electronics card test failed.  
956-108      D        956      Description: The bus test failed.
956-110      D        956      Description: The media format is corrupted.
  
956-112      D        956      Description: The diagnostic test failed.
956-114      D        956      Description: An unrecoverable hardware error.
   
956-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.
    
956-117      D        956      Description: A write protect error occurred.
956-118      D        956      Description: A SCSI command time-out.   
956-120      D        956      Description: A SCSI busy or command error.  
956-122      D        956      Description: A SCSI reservation conflict error.
956-124      D        956      Description: A SCSI check condition error.
  
956-126      D        956      Description: A software error was caused
                               by a hardware failure.

956-128         G        956   Description: The error log analysis
                               indicates a hardware failure.
 
956-130         G        956   Description: The error log analysis
                               indicates a hardware failure.

956-132         D        956   Description: A disk drive hardware error occurred.

956-134         D        B88   Description: The adapter failed to configure.software
956-136         D        956   Description: The certify operation failed.
959-098         J        959   Description: Disk drive indicates an error.
959-099         j        959   Description: Disk drive not found.
959-102         D        959   Description: Non-recoverable medium error.
959-104         D        959   Description: Motor failed to restart.
959-105         D        959   Description: The drive did not become ready.
959-106         D        959   Description: Electronics card failure.
959-108         D        959   Description: Bus failure.
959-110         D        959   Description: The media format is corrupted.
959-112         D        959   Description: Diagnostic failure.
959-114         D        959   Description: Non-recoverable hardware error.

959-116         D              Description: A protocol error was
                               detected.
                               Action: Check the levels of the device,
                               adapter, diagnostic and application
                               software, and ensure they are all
                               compatible. If you do not find a problem,
                               call your support person.

959-117      D       959       Description: Write protect error.
959-118      D        959      Description: SCSI command timeout.
959-120      D        959      Description: SCSI busy/command error.
959-122      D        959      Description: SCSI reservation conflict error.
959-124      D        959      Description: SCSI check condition error.

959-126      D        959      Description: Software error caused by
                               hardware failure.

959-128      G        959      Description: Error log analysis
                               indicates hardware failure.

959-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem. 959  B88 software

959-130      G        959      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.
                                 
959-134      D        B88      Description: The adapter failed to configure.software
959-135      D        959      Description: The device failed to configure.B88 software
959-136      D        959      Description: The certify operation failed.

959-137      D        959      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.
                                 
960-102      D        960      Description: An unrecoverable media error.
960-104      D        960      Description: The motor failed to restart.
960-105      D        960      Description: The drive did not become ready.
960-106      D        960      Description: The electronics card test failed.
960-108      D        960      Description: The bus test failed.
960-110      D        960      Description: The media format is corrupted.
960-112      D        960      Description: The diagnostic test failed.
960-114      D        960      Description: An unrecoverable hardware error.

960-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

960-117      D        960      Description: A write protect error occurred.
960-118      D        960      Description: A SCSI command time-out.
960-120      D        960      Description: A SCSI busy or command error.
960-122      D        960      Description: A SCSI reservation conflict error.
960-124      D        960      Description: A SCSI check condition error.

960-126      D        960      Description: A software error was caused
                               by a hardware failure.       

960-128      G        960      Description: The error log analysis
                               indicates a hardware failure.

960-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.960 B88 software

960-130      G        960      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

960-132      D        960      Description: A disk drive hardware error occurred.
960-134      D        B88      Description: The adapter failed to configure. software
960-135      D        960      Description: The device failed to configure.software
960-136      D        960      Description: The certify operation failed.
  
960-137      D        960      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.
                         
964-098      J        964    Description: Tape drive indicates an error.

964-099      J        964    Description: Tape drive not found.

964-101      D        964    Description: Timeout while attempting
                             to communicate with SCSI device.
                              
964-102      D        964    Description: The SCSI device indicates busy.
   
964-103      D        964    Description: The SCSI device indicates
                             a reservation conflict.
                
964-104      D        964    Description: The SCSI device indicates
                             a check condition.
                
964-105      D        964    Description: An error is detected in
                             request sense data.
                
964-107      D        964    Description: Sense data from the SCSI
                             drive has unexpected data.

964-110      D        964    Description: The Reserve command failed.

964-111      D        964    Description: Invalid condition from the
                             drive after a reserve.
                
964-112      D        964    Description: The write protect sensor test failed.

964-113      D        964    Description: Invalid condition from
                             drive after a request sense.

964-114      D        964    Description: Timeout while attempting to
                             communicate with the SCSI device.

964-120      D        964    Description: The Inquiry command failed.
964-130      D        964    Description: The Load command failed. media
964-134      D        B88    Description: The adapter failed to configure.software
964-135      D        964    Description: The Unload command failed. media
964-140      D        964    Description: The Mode Select command failed.
                
964-150      D        964    Description: The Test Unit Ready
                             command failed. media

964-160      D        964    Description: The Send Diagnostic
                             command failed. media
                             
964-161      D        964    Description: Invalid condition from the
                             drive after a reserve.   B88

964-163      D        964    Description: Invalid condition from the
                             drive after a request sense.   B88

964-164      D        964    Description: Timeout while attempting
                             to communicate with the SCSI device. B88

964-165      D        964    Description: Write, Read and Compare Test failed.
964-166      D        964    Description: Unable to configure the device.software
964-167      D        964    Description: An unexpected SCSI error occurred.   
964-168      D        964    Description: The adapter failed to configure.   software
964-169      D        964    Description: The send diagnostic command failed.media
964-170      D        964    Description: The Read, Write and Compare test failed.media
964-180      D        964    Description: The Load command failed. media
964-185      D        964    Description: The Unload command failed. media
964-190      D        964    Description: The Mode Select command failed.
964-200      D        964    Description: The Test Unit Ready command failed. media
964-201      G        964    Description: Error diagnosed from error log analysis.
964-210      D        964    Description: The device configuration failed. B88
964-211      D        964    Description: The device open failed. B88
964-220      D        964    Description: The Release command failed.
964-230      D        964    Description: The Request Sense command failed.
964-240      D        964    Description: The Openx command failed.
964-260      D        964    Description: The device configuration
964-261      D        964    Description: The device open failed.
964-300      D        964    Description: The device configuration failed. software
964-310      D        B88    Description: SCSI adapter configuration failed.software

964-320      G        964    Description: Error log analysis
                             indicates a failure.  media
                
964-411      D        964    Description: A reservation conflict
    to                       occurred. software
964-423               

964-511      D        964    Description: The drive returned bad or
    to                       non-extended sense data.
964-523               

964-611      D        964     Description: An adapter or bus I/O
    to                        error occurred. software
964-623                      

964-711      D        964     Description: A device timeout error
    to                        occurred.  software
964-723                
   
966-101      D        966      Error in non-interactive tests.
966-103      D        966      The test pattern failed.
966-201      D        966      Description: Error in non-interactive tests on card
966-203      D        996      Description: The test pattern failed.
966-205      D        966      Description: Test pattern failed
966-207      D        966      Description: Test pattern failed
966-208      D        190      Description: Error in non-interactive test on card
966-209      D                 Description: Test pattern failed
966-211      D                 Test pattern failed
966-213      D                 Test pattern failed
966-304      D        E22      Video error in interactive test
966-306      D        E23      Audio error in interactive test
966-310      D        E22      Video error in interactive test
966-312      D        E23      Audio error in interactive test
966-400      D        152      Error in non-interactive tests
966-402      D        190      Test pattern failed
968-102      D        968      Description: An unrecoverable media error.
968-104      D        968      Description: The motor failed to restart.
968-105      D        968      Description: The drive did not become ready.
968-106      D        968      Description: The electronics card test failed.
968-108      D        968      Description: The bus test failed.
968-110      D        968      Description: The media format is corrupted.
968-112      D        968      Description: The diagnostic test failed.
968-114      D        968      Description: An unrecoverable hardware error.

968-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

968-117      D        968      Description: A write protect error occurred.
968-118      D        968      Description: A SCSI command time-out.
968-120      D        968      Description: A SCSI busy or command error.
968-122      D        968      Description: A SCSI reservation conflict error.
968-124      D        968      Description: A SCSI check condition error.

968-126      D        968      Description: A software error was caused
                               by a hardware failure.    

968-128      G        968      Description: The error log analysis
                               indicates a hardware failure.

968-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem. 968 B88 software

968-130      G        968      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

968-132      D        968      Description: A disk drive hardware error occurred.
968-134      D        B88      Description: The adapter failed to configure.software
968-135      D        968      Description: The device failed to configure.software
968-136      D        968      Description: The certify operation failed.
   
968-137      D        968      Description: Unit attention condition
                               has occurred on the Send Diagnostic command
                         
969-110      G        D67      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-111      G        D83      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-120      G        D68      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-121      G        D84      Description: Residual Data Analysis
                               indicates memory error.
                                 .
969-130      G        D69      Description: Residual Data Analysis
                               indicates memory error.
                               
969-131      G        D85      Description: Residual Data Analysis
                               indicates memory error.
                             
969-140      G        D70      Description: Residual Data Analysis
                               indicates memory error.
                                
969-141      G        D86      Description: Residual Data Analysis
                               indicates memory error.
                                
969-150      G        E11      Description: Residual Data Analysis
                               indicates memory error.
                         
969-151      G        E14      Description: Residual Data Analysis
                               indicates memory error.
                               
969-206      G        D72      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-208      G        D73      Description: Residual Data Analysis
                               indicates memory error.
                                
969-210      G        D71      Description: Residual Data Analysis
                               indicates memory error.
                             
969-211      G        D87      Description: Residual Data Analysis
                               indicates memory error.
                                
969-212      G        E12      Description: Residual Data Analysis
                               indicates memory error.

969-220      G        D72      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-221      G        D88      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-230      G        D73      Description: Residual Data Analysis
                               indicates memory error.
                                
969-231      G        D89      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-240      G        D74      Description: Residual Data Analysis
                               indicates memory error.
                                
969-241      G        D90      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-250      G        E12      Description: Residual Data Analysis
                               indicates memory error.
                               
969-251      G        E15      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-310      G        D75      Description: Residual Data Analysis
                               indicates memory error.
                                
969-311      G        D91      Description: Residual Data Analysis
                               indicates memory error.
                             
969-320      G        D76      Description: Residual Data Analysis
                               indicates memory error.
                              
969-321      G        D92      Description: Residual Data Analysis
                               indicates memory error.
                               
969-330      G        D77      Description: Residual Data Analysis
                               indicates memory error.
                                
969-331      G        D93      Description: Residual Data Analysis
                               indicates memory error.
                               
969-340      G        D78      Description: Residual Data Analysis
                               indicates memory error.
                                
969-341      G        D94      Description: Residual Data Analysis
                               indicates memory error.
                                   
969-350      G        E13      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-351      G        E16      Description: Residual Data Analysis
                               indicates memory error.
                                 
969-600      G                 Description: Residual Data Analysis
                               indicates memory error or unsupported memory.
                               Action: Examine the memory modules and
                               determine if they are supported types. If
                               the modules are supported, then replace
                               the appropriate memory module(s). Use
                               Chapter 14. "MAP 0240: Memory Problem
                               Resolution".

969-701      D        814      Description: NVRAM test failed
969-702      D        151      Description: Time of Day Battery test failed
969-703      D        817      Description: Time of Day Chip test failed

969-800      G        221      Description: Memory problems indicate
                               System Planar failure
 
969-900      G        D01      Description: L2 cache test failed
970-098      J        970      Description: Tape drive indicates an error. 
970-099      J        970      Description: Tape drive not found.

970-101      D        970      Description: Timeout while attempting to
                               communicate with SCSI device.

970-102      D        970      Description: The SCSI device indicates busy.

970-103      D        970      Description: The SCSI device indicates a
                               reservation conflict.

970-104      D        970      Description: The SCSI device indicates a
                               check condition.

970-105      D        970      Description: An error is detected in
                               request sense data.

970-107      D        970      Description: Sense data from the SCSI
                               drive has unexpected data.

970-110      D        970      Description: The Reserve command failed.

970-111      D        970      Description: Invalid condition from the
                               drive after a reserve.

970-112      D        970      Description: The write protect sensor test failed.

970-113      D        970      Description: Invalid condition from
                               drive after a request sense.

970-114      D        970      Description: Timeout while attempting to
                               communicate with the SCSI device.

970-120      D        970      Description: The Inquiry command failed.
970-130      D        970      Description: The Load command failed.  media
970-134      D        B88      Description: The adapter failed to configure.software
970-135      D        970      Description: The Unload command failed. media
970-140      D        970      Description: The Mode Select command failed.
970-150      D        970      Description: The Test Unit Ready command failed.media
970-160      D        970      Description: The Send Diagnostic command failed.media

970-161      D        970      Description: Invalid condition from the
                               drive after a reserve.

970-163      D        970      Description: Invalid condition from the
                               drive after a request sense.

970-164      D        970      Description: Timeout while attempting to
                               communicate with the SCSI device.
                         
970-165      D        970      Description: Write, Read and Compare Test failed.
970-166      D        970      Description: Unable to configure the device.software
970-167      D        970      Description: An unexpected SCSI error occurred. 
970-168      D        B88      Description: The adapter failed to configure. software
970-169      D        970      Description: The send diagnostic command failed. media
970-170      D        970      Description: The Read, Write and Compare test failed.                         
970-180      D        970      Description: The Load command failed.   media
970-185      D        970      Description: The Unload command failed.  media
970-190      D        970      Description: The Mode Select command failed.
970-200      D        970      Description: The Test Unit Ready command failed. media
970-201      G        970      Description: Error diagnosed from error log analysis.
970-210      D        970      Description: The device configuration failed.
970-211      D        970      Description: The device open failed.
970-220      D        970      Description: The Release command failed.
970-230      D        970      Description: The Request Sense command failed.
970-240      D        970      Description: The Openx command failed.
970-260      D        970      Description: The device configuration failed.
970-261      D        970      Description: The device open failed.
970-300      D        970      Description: The device configuration failed.software
970-310      D        B88      Description: SCSI adapter configuration failed.software
970-320      G        970      Description: Error log analysis indicates a failure. media

970-411      D        970      Description: A reservation conflict  occurred.
   to                 B88
970-423               software

970-511      D        970      Description: The drive returned bad or
     to                        non-extended sense data.
970-523

970-611      D        970      Description: An adapter or bus I/O error occurred.
    to                B88
970-623            software

970-711      D        970      Description: A device timeout error occurred.
     to               B88
970-723               software

971-098      J        971      Description: Tape drive indicates an error.
971-099      J        971      Description: Tape drive not found.   B88

971-101      D        971      Description: Timeout while attempting to
                               communicate with SCSI device.

971-102      D        971      Description: The SCSI device indicates busy.

971-103      D        971      Description: The SCSI device is
                               indicating a reservation conflict.

971-104      D        971      Description: The SCSI device indicates a
                               check condition.

971-105      D        971      Description: Sense data from the SCSI
                               device shows an error.

971-107      D        971      Description: The SCSI drive returned
                               unexpected sense data.

971-110      D        971      Description: The Reserve command failed.

971-111      D        971      Description: Invalid condition from the
                               drive after a reserve.

971-112      D        971      Description: The write protect sensor test failed.

971-113      D        971      Description: Invalid condition from the
                               drive after a request sense.

971-114      D        971      Description: Timeout while attempting to
                               communicate with the SCSI device.

971-120      D        971      Description: The Inquiry command failed.
971-130      D        971      Description: The Load command failed. media
971-135      D        971      Description: The Unload command failed. media
971-140      D        971      Description: The Mode Select command failed.
971-150      D        971      Description: The Test Unit Ready command failed.media
971-160      D        971      Description: The Send Diagnostic command failed.media
971-161      D        971      Description: Invalid condition from the
                               drive after a reserve.

971-163      D        971      Description: Invalid condition from the
                               drive after a request sense.       B88

971-164      D        971      Description: Timeout while attempting to
                               communicate with the SCSI device.    B88

971-165      D        971      Description: Write, Read and Compare Test failed.
971-166      D        971      Description: Unable to configure the device.software
971-167      D        971      Description: An unexpected SCSI error occurred.   
971-168      D        B88      Description: The adapter failed to configure.software
971-169      D        971      Description: The Send Diagnostic command failed.media
971-170      D        971      Description: The Read, Write and Compare test failed.media
971-180      D        971      Description: The Load command failed. media
971-185      D        971      Description: The Unload command failed.  media
971-190      D        971      Description: The Mode Select command failed.
971-200      D        971      Description: The Test Unit Ready command failed.
971-201      G        971      Description: An error is diagnosed from the error log analysis. 
971-210      D        971      Description: The device configuration failed.
971-211      D        971      Description: The device open test failed.
971-220      D        971      Description: The Release command failed.
971-230      D        971      Description: The Request Sense command failed.
971-240      D        971      Description: The Openx command failed.
971-260      D        971      Description: The device configuration failed.
971-261      D        971      Description: The device open test failed.
971-300      D        971      Description: The device configuration failed. software
971-310      D        B88      Description: SCSI adapter configuration failed.software
                                 
971-320      G        971      Description: Error log analysis
                               indicates a failure.media

971-411      D        971      Description: A reservation conflict occurred.
    to                B88      software
971-423                        

971-511      D        971      Description: The drive returned bad or
      to                       non-extended sense data.
971-523

971-611      D        971      Description: An adapter or bus I/O error
      to                       occurred.
971-623                        software

971-711      D        971      Description: A device timeout error
    to                         occurred.      B88
971-723                        software

972-101      D        972      Description: Timeout while attempting to
                               communicate with SCSI device.

972-102      D        972      Description: The SCSI device indicates busy.

972-103      D        972      Description: The SCSI device indicates a
                               reservation conflict.

972-104      D        972      Description: The SCSI device indicates a
                               check condition.

972-105      D        972      Description: An error is detected in
                               request sense data.

972-107      D        972      Description: The drive has returned
                               unexpected sense data.

972-110      D        972      Description: The Reserve command failed.

972-111      D        972      Description: Invalid condition from the
                               drive after a reserve.

972-112      D        972      Description: The write protect sensor
                               test failed.

972-113      D        972      Description: Invalid condition from the
                               drive after a request sense.

972-114      D        972      Description: Timeout while attempting to
                               communicate with the SCSI device.

972-120      D        972      Description: The Inquiry command failed.
972-130      D        972      Description: The Load command failed. media
972-135      D        972      Description: The Unload command failed. media
972-140      D        972      Description: The Mode Select command failed.
972-150      D        972      Description: The Test Unit Ready command failed.media
972-160      D        972      Description: The Send Diagnostic command failed.media

972-161      D        972      Description: Invalid condition from the
                               drive after a reserve.      B88

972-163      D        972      Description: Invalid condition from the
                               drive after a request sense.        B88

972-164      D        972      Description: Timeout while attempting
                               communication with SCSI device. B88   276

972-165      D        972      Description: Write, Read and Compare Test failed. 
972-166      D        972      Description: Unable to configure the device.software
972-167      D        972      Description: An unexpected SCSI error occurred.
972-168      D        B88      Description: The adapter failed to configure.software
972-169      D        972      Description: The send diagnostic command failed.media
972-170      D        972      Description: The Read, Write and Compare test failed.media
972-180      D        972      Description: The Load command failed.  media
972-185      D        972      Description: The Unload command failed. media
972-190      D        972      Description: The Mode Select command failed.
972-200      D        972      Description: The Test Unit Ready command failed.media
972-201      G        972      Description: An error is diagnosed from the error log analysis. 
972-210      D        972      Description: The device configuration failed.    
972-211      D        972      Description: The device open test failed.              
972-220      D        972      Description: The Release command failed.
972-230      D        972      Description: The Request Sense command failed.
972-240      D        972      Description: The Openx command failed.
972-260      D        972      Description: The device configuration test failed.
972-261      D        972      Description: The device open test failed.
972-300      D        972      Description: The device configuration failed.software
972-310      D        B88      Description: SCSI adapter configuration failed.software
972-320      G        972      Description: Error log analysis indicates a failure. media

972-411      D        972     Description: A reservation conflict
    to                        occurred.
972-423               B88     software

972-511      D        972      Description: The drive returned bad or
     to                        non-extended sense data.
972-523               B88
   
972-611      D        972     Description: An adapter or bus I/O error
     to                       occurred.
972-623               B88     software

972-711      D        972     Description: A device timeout error
      to                      occurred.
972-723               B88     software
   
973-110      D        973      Description: The Reserve command failed.
973-120      D        973      Description: The Inquiry command failed.
973-130      D        973      Description: The Load command failed.   media
973-135      D        973      Description: The Unload command failed. media
973-140      D        973      Description: The Mode Select command failed.
973-150      D        973      Description: The Test Unit Ready command failed. media
973-160      D        973      Description: The Send Diagnostic command failed.media
973-169      D        973      Description: The send diagnostic command failed. media
973-170      D        973      Description: The Read, Write and Compare test failed.
973-180      D        973      Description: The Load command failed.   media
973-185      D        973      Description: The Unload command failed.  media
973-190      D        973      Description: The Mode Select command failed.
973-200      D        973      Description: The Test Unit Ready command failed.media
973-210      D        973      Description: The device configuration failed.
973-220      D        973      Description: The Release command failed.
973-230      D        973      Description: The Request Sense command failed.
973-240      D        973      Description: The Openx command failed.
973-300      D        973      Description: The device configuration failed.software
973-310      D        B88    Description: SCSI adapter configuration failed.software

973-320      G        973    Description: Error log analysis
                             indicates a failure.    media

973-411      D        973    Description: A reservation conflict
      to                     occurred.
973-423               B88    software

973-511      D        973    Description: The drive returned bad or
      to                     non-extended sense data.
973-523               B88

973-611      D        973     Description: An adapter or bus I/O error
      to                      occurred.
973-623               B88     software

973-711      D        973     Description: A device timeout error
      to                      occurred.
973-723               B88     software

974-111      D        974      Description: Unable to reserve device. B88
974-112      D        974      Description: Unable to do configuration.
974-113      D        974      Description: Unable to open the device driver.  B88
974-121      D        974      Description: The CD-ROM drive indicates an error.
974-122      D        974      Description: The CD-ROM drive indicates an error.
974-123      D        974      Description: The CD-ROM drive indicates an error.
974-125      D        974      Description: The CD-ROM drive indicates an error.
974-126      D        974      Description: The CD-ROM drive indicates an error.
974-127      D        974      Description: The CD-ROM drive indicates an error.
974-128      D        974      Description: The CD-ROM drive indicates an error.
974-129      D        974      Description: The CD-ROM drive indicates an error.
974-150      D       Media     Description: A media error was detected.
974-151      D        974      Description: A command timeout was detected.

974-152      D        974      Description: A command reservation
                               conflict was detected.

974-162      D        974      Description: The CD-ROM drive indicates an error.
974-171      D        974      Description: Unable to reserve device.
974-172      D        974      Description: Unable to do configuration.
974-173      D        974      Description: Unable to open device driver.

974-175      D        974      Description: The CD-ROM drive indicates an error.
974-198      D        974      Description: Undefined error detected.    B88
974-199      D        974      Description: Undefined error detected.
974-211      D        974      Description: The LED test failed.
974-281      D        974      Description: No tone during audio test.
974-301      G        974      Description: Errors found during ELA.

974-302      G        974      Description: Errors log analysis
                               indicates hardware failure.     B88
                                 
981-102      D       981       Description: An unrecoverable media  error.
981-104      D       981       Description: The motor failed to restart.
981-105      D       981       Description: The drive did not become ready.
981-106      D       981       Description: The electronics card test failed.
981-108      D       981       Description: The bus test failed.
981-110      D       981       Description: The media format is corrupted.
981-112      D       981       Description: The diagnostic test failed.
981-114      D       981       Description: An unrecoverable hardware error.

981-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.
   
981-117      D        981      Description: A write protect error  occurred.
981-118      D        981      Description: A SCSI command time-out.
981-120      D        981      Description: A SCSI busy or command error.
981-122      D        981      Description: A SCSI reservation conflict error.
981-124      D        981      Description: A SCSI check condition error.
                
981-126      D        981      Description: A software error was
                               caused by a hardware failure.    

981-128      G        981      Description: The error log analysis
                               indicates a hardware failure.

981-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem. 981 B88 software

981-130      G        981      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

981-132      D        981      Description: A disk drive hardware  error occurred.
981-134      D        B88      Description: The adapter failed to configure.software
981-136      D        981      Description: The certify operation failed.
                
981-137      D        981      Description: Unit attention condition
                               has occurred on the Send Diagnostic command 

984-102      D        984      Description: An unrecoverable media error.
984-104      D        984      Description: The motor failed to restart.
984-105      D        984      Description: The drive did not become ready.
984-106      D        984      Description: The electronics card test failed.
984-108      D        984      Description: The bus test failed.
984-110      D        984      Description: The media format is corrupted.
984-112      D        984      Description: The diagnostic test failed.
984-114      D        984      Description: An unrecoverable hardware error.

984-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

984-117      D        984      Description: A write protect error occurred.
984-118      D        984      Description: A SCSI command time-out. B88
984-120      D        984      Description: A SCSI busy or command error.
984-122      D        984      Description: A SCSI reservation conflict error.
984-124      D        984      Description: A SCSI check condition  error.

984-126      D        984      Description: A software error was caused
                               by a hardware failure.  B88

984-128      G        984      Description: The error log analysis
                               indicates a hardware failure.

984-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.

984-130      G        984      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

984-132      D        984      Description: A disk drive hardware error occurred.
984-134      D        B88      Description: The adapter failed to configure.  software

984-137      D        984      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.  

986-102      D        986      Description: An unrecoverable media error.
986-104      D        986      Description: The motor failed to restart.
986-105      D        986      Description: The drive did not become ready.
986-106      D        986      Description: The electronics card test  failed.
986-108      D        986      Description: The bus test failed.
986-110      D        986      Description: The media format is corrupted.
986-112      D        986      Description: The diagnostic test failed.
986-114      D        986      Description: An unrecoverable hardware error.
 
986-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.
 
986-117      D        986      Description: A write protect error occurred. 
986-118      D        986      Description: A SCSI command time-out.
986-120      D        986      Description: A SCSI busy or command  error. 
986-122      D        986      Description: A SCSI reservation conflict error. 
986-124      D        986      Description: A SCSI check condition error.
 
986-126      D        986      Description: A software error was caused
                               by a hardware failure.

986-128      G        986      Description: The error log analysis
                               indicates a hardware failure.

986-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem. 986  B88  software

986-130      G        986      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

986-132      D        986      Description: A disk drive hardware error occurred.
986-134      D        B88      Description: The adapter failed to configure. software
986-136      D        986      Description: The certify operation failed.

986-137      D        986      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.

987-111      D        987      Description: Unable to reserve device.
987-112      D        987      Description: Unable to do configuration.
987-113      D        987      Description: Unable to open the device driver.   
987-121      D        987      Description: The CD-ROM drive indicates an error.   
987-122      D        987      Description: The CD-ROM drive indicates an error.   
987-123      D        987      Description: The CD-ROM drive indicates an error.
987-125      D        987      Description: The CD-ROM drive indicates an error.
987-126      D        987      Description: The CD-ROM drive indicates an error.   
987-127      D        987      Description: The CD-ROM drive indicates an error.   
987-128      D        987      Description: The CD-ROM drive indicates an error.   
987-129      D        987      Description: The CD-ROM drive indicates an error.   
987-150      D       Media     Description: A media error was detected.
987-151      D        987      Description: A command timeout was detected.  
987-152      D        987      Description: A command reservation conflict was detected.   
987-162      D        987      Description: The CD-ROM drive indicates an error.   
987-171      D        987      Description: Unable to reserve device.
987-172      D        987      Description: Unable to do configuration.
987-173      D        987      Description: Unable to open device driver.  
987-175      D        987      Description: The CD-ROM drive indicates an error.  
987-198      D        987      Description: Undefined error detected.
987-199      D        987      Description: Undefined error detected.
987-211      D        987      Description: The LED test failed.
987-281      D        987      Description: No tone during audio test.
987-301      G        987      Description: Errors found during ELA.
987-302      G        987      Description: Errors found during ELA.
989-102      D        989      Description: An unrecoverable media error  
989-104      D        989      Description: The motor failed to restart.   
989-105      D        989      Description: The drive did not become ready.   
989-106      D        989      Description: The electronics card test failed.   
989-108      D        989      Description: The bus test failed.
989-110      D        989      Description: The media format is corrupted.   
989-112      D        989      Description: The diagnostic test failed.
989-114      D        989      Description: A non-recoverable hardware error
   
989-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.
   
989-117      D        989      Description: A write protect error occurred.   
989-118      D        989      Description: A SCSI command time-out.
989-120      D        989      Description: A SCSI busy or command error.    
989-122      D        989      Description: A SCSI reservation conflict error
989-124      D        989      Description: A SCSI check condition error

989-126      D        989      Description: A software error was caused
                               by a hardware failure.

989-128      G        989      Description: The error log analysis
                               indicates a hardware failure.

989-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.software
                                 
989-130      G        989      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

989-132      D        989      Description: A disk drive hardware error occurred.
989-134      D        B88      Description: The adapter failed to configure.software
989-135      D        989      Description: The device failed to configure.software
989-136      D        989      Description: The certify operation failed.
989-137      D        989      Description: Unit attention condition
                               has occurred on the Send Diagnostic command.

990-102      D        990      Description: An unrecoverable media error.
990-104      D        990      Description: The motor failed to  restart.
990-105      D        990      Description: The drive did not become ready.
990-106      D        990      Description: The electronics card test failed.
990-108      D        990      Description: The bus test failed.
990-110      D        990      Description: The media format is corrupted.
990-112      D        990      Description: The diagnostic test failed.
990-114      D        990      Description: An unrecoverable hardware error.

990-116      D                 Description: A protocol error.
                               Action: Check the levels of the device,
                               adapter, diagnostic software, and
                               application software to be sure they are
                               all compatible. If you do not find a
                               problem, call your support person.

990-117      D        990      Description: A write protect error occurred.
990-118      D        990      Description: A SCSI command time-out.
990-120      D        990      Description: A SCSI busy or command error.
990-122      D        990      Description: A SCSI reservation conflict error.
990-124      D        990      Description: A SCSI check condition error.

990-126      D        990      Description: A software error was caused
                               by a hardware failure.

990-128      G        990      Description: The error log analysis
                               indicates a hardware failure.

990-129      G        D50      Description: Error log analysis
                               indicates a SCSI bus problem.  software

990-130      G        990      Description: Error log analysis
                               indicates a problem reported by the disk
                               drive's self monitoring function.

990-132      D        990      Description: A disk drive hardware error occurred.
990-134      D        B88      Description: The adapter failed to configure.software
990-136      D        990      Description: The certify operation failed.

990-137      D        990      Description: Unit attention condition
                               has occurred on the Send Diagnostic
                      B88      command.      D50

991-101      D        991      Description: Timeout while attempting to
                               communicate with SCSI device.

991-102      D        991      Description: The SCSI device indicates busy.

991-103      D        991      Description: The SCSI device is
                               indicating a reservation conflict.

991-104      D        991      Description: The SCSI device indicates a
                               check condition.

991-105      D        991      Description: Sense data from the SCSI
                               device shows an error.

991-107      D        991      Description: The SCSI drive returned
                               unexpected sense data.

991-110      D        991      Description: The Reserve command failed.
991-111      D        991      Description: Invalid condition from the
                               drive after a reserve.

991-112      D        991      Description: The write protect sensor
                               test failed.

991-113      D        991      Description: Invalid condition from the
                               drive after a request sense.

991-114      D        991      Description: Timeout while attempting to
                               communicate with the SCSI device.

991-120      D        991      Description: The Inquiry command failed.
991-130      D        991      Description: The Load command failed. media
991-135      D        991      Description: The Unload command failed. media
991-140      D        991      Description: The Mode Select command failed.
991-150      D        991      Description: The Test Unit Ready command failed. media
991-160      D        991      Description: The Send Diagnostic command failed.media

991-161      D        991      Description: Invalid condition from the
                               drive after a reserve.   B88

991-163      D        991      Description: Invalid condition from the
                               drive after a request sense.    B88
                                 
991-164      D        991      Description: Timeout while attempting to
                               communicate with the SCSI device. B88

991-165      D        991      Description: Write, Read and Compare Test failed.
991-166      D        991      Description: The device failed to configure.software
991-167      D        991      Description: An unexpected SCSI error occurred.
991-168      D        B88      Description: The adapter failed to configure.software
991-169      D        991      Description: The send diagnostic command failed.
991-170      D        991      Description: The Read, Write and Compare test failed.media
991-180      D        991      Description: The Load command failed.   media
991-185      D        991      Description: The Unload command failed.  media
991-190      D        991      Description: The Mode Select command failed.
991-200      D        991      Description: The Test Unit Ready command failed. media

991-201      G        991      Description: An error is diagnosed from
                               the error log analysis.         B88

991-210      D        991      Description: The device configuration failed.
991-211      D        991      Description: The device open test failed.
991-220      D        991      Description: The Release command failed.
991-230      D        991      Description: The Request Sense command failed.
991-240      D        991      Description: The Openx command failed.
991-260      D        991      Description: The device configuration failed.
991-261      D        991      Description: The device open test failed.
991-300      D        991      Description: The device configuration failed.software
991-310      D        B88      Description: SCSI adapter configuration failed.software
                                 
991-320      G        991      Description: Error log analysis
                               indicates a failure.media

991-411      D        991      Description: A reservation conflict
      to                       occurred.
991-423               B88      software

991-511      D        991      Description: The drive returned bad or
      to                       non-extended sense data.
991-523               B88
   
991-611      D        991      Description: An adapter or bus I/O error
      to                       occurred.
991-623               B88      software

991-711      D        991      Description: A device timeout error
      to                       occurred.
991-723               B88      software

994-110      D        994      Description: The Reserve command failed.
994-120      D        994      Description: The Inquiry command failed.
994-130      D        994      Description: The Load command failed.  media
994-135      D        994      Description: The Unload command failed. media
994-140      D        994      Description: The Mode Select command failed.
994-150      D        994      Description: The Test Unit Ready command failed.media
994-160      D        994      Description: The Send Diagnostic command failed.media
994-169      D        994      Description: The send diagnostic command failed.media
994-170      D        994      Description: The Read, Write and Compare test failed.
994-180      D        994      Description: The Load command failed. media
994-185      D        994      Description: The Unload command failed.  media
994-190      D        994      Description: The Mode Select command failed.
994-200      D        994      Description: The Test Unit Ready command failed.media
994-210      D        994      Description: The device configuration failed.   
994-220      D        994      Description: The Release command failed.
994-230      D        994      Description: The Request Sense command failed.
994-240      D        994      Description: The Openx command failed.
994-300      D        994      Description: The device configuration failed.software
994-310      D        B88      Description: SCSI adapter configuration failed.software
994-320      G        994      Description: Error log analysis indicates a failure.media

994-411      D        994      Description: A reservation conflict
      to                       occurred.
994-423               B88      software
   
994-511      D        994      Description: The drive returned bad or
      to                        non-extended sense data.
994-523               B88

994-611      D        994      Description: An adapter or bus I/O error
      to                       occurred.
994-623               B88      software

994-711      D        994      Description: A device timeout error
      to              B88      occurred.
994-723                        software

995-110      D        995      Description: The Reserve command failed.
995-120      D        995      Description: The Inquiry command failed.
995-130      D        995      Description: The Load command failed. media
995-135      D        995      Description: The Unload command failed. media
995-140      D        995      Description: The Mode Select command failed.
995-150      D        995      Description: The Test Unit Ready command failed.media
995-160      D        995      Description: The Send Diagnostic command failed.media
995-169      D        995      Description: The send diagnostic command failed.media
995-170      D        995      Description: The Read, Write and Compare test failed.media
995-180      D        995      Description: The Load command failed. media
995-185      D        995      Description: The Unload command failed. media
995-190      D        995      Description: The Mode Select command failed.
995-200      D        995      Description: The Test Unit Ready command failed. media
995-210      D        995      Description: The device configuration failed. B88
995-220      D        995      Description: The Release command failed.
995-230      D        995      Description: The Request Sense command failed.
995-240      D        995      Description: The Openx command failed.
995-300      D        995      Description: The device configuration failed.software
995-310      D        B88      Description: SCSI adapter configuration failed.software
995-320      G        995      Description: Error log analysis indicates a failure.media

995-411      D        995      Description: A reservation conflict
      to                       occurred.
995-423               B88      software

995-511      D        995      Description: The drive returned bad or
      to                       non-extended sense data.
995-523               B88

995-611      D        995      Description: An adapter or bus I/O error
      to                       occurred.
995-623               B88      software

995-711      D        995      Description: A device timeout error
      to                       occurred.
995-723               B88      software

998-110      D        998      Description: The Reserve command failed.
998-120      D        998      Description: The Inquiry command failed.
998-130      D        998      Description: The Load command failed. media
998-135      D        998      Description: The Unload command failed. media
998-140      D        998      Description: The Mode Select command failed.
998-150      D        998      Description: The Test Unit Ready command failed.media
998-160      D        998      Description: The Send Diagnostic command failed.media
998-169      D        998      Description: The send diagnostic command failed.media
998-170      D        998      Description: The Read, Write and Compare test failed.media
998-180      D        998      Description: The Load command failed. media
998-185      D        998      Description: The Unload command failed. media
998-190      D        998      Description: The Mode Select command failed.
998-200      D        998      Description: The Test Unit Ready command failed.media
998-210      D        998      Description: The device configuration failed.  
998-220      D        998      Description: The Release command failed.
998-230      D        998      Description: The Request Sense command failed.  
998-240      D        995      Description: The Openx command failed.
998-300      D        995      Description: The device configuration failed.software
998-310      D        B88      Description: SCSI adapter configuration failed.software
998-320      G        995      Description: Error log analysis  indicates a failure.media

998-411      D        998      Description: A reservation conflict
      to                       occurred.
998-423               B88      software

998-511      D        998      Description: The drive returned bad or
      to                       non-extended sense data.
998-523               B88

998-611      D        998   Description: An adapter or bus I/O error
      to                    occurred.
998-623               B88   software

998-711      D        998     Description: A device timeout error
      to                      occurred.
998-723               B88     software

999-xxx      D        999      Description: A 7137 or 3514 disk array series
                               subsystem problem is indicated.
                               Action: Use 7137 or 3514 documentation.

9CC-1xx      G                 Description: I/O Error on PCI bus.
                               Note: xx represents the last 2 digits of
                               the SRN.

9CC-xxx      G        xxx      Description: I/O Bus Data, Address
                               Parity Error, or Time-out error.
                               Note: xxx represents the last 3 digits of
                               the SRN.
 
xxxxxxxx     G        none     Description: Refer to the Error Code to
                               FRU Index in the system unit's service
                               guide.
                               Action: Use the "Error Code to FRU Index"
                               in the service guide.

Common Error Codes

E1F1 on LED front of the box

   Likely that there was one of three things that could be causing he problem...

1) There is media loaded that contains a faulty BLV 
2) The bootlist does contain the device that contains a BLV
3) The BLV is corrupt and will have to be rebuilt
4) Hardware failure on the correct boot device


Machine boots up with a 4b2b2405

This error code is a service processor error code dictating that there 
is a problem with the wire test that occurs at IPL with the
500Mhz 2-way proc.  Call   IBM SERV.


f1e
Additional Information on where to check first.

The PowerPC 604e processor has 32KB of instruction and data cache plus an additional
1MB of L2 cache to provide even greater power. 
The cache is on the 604e proc

I would try the instruction and data cache
The proc or the removable cache that is on the proc There is a fixed 32kb cache 
and then a removable (1mb old) 2mb cache chip
This is probably what is bad on this machine based on f1e….